Loading...
HomeMy WebLinkAboutFile Documents.185 Forge Rd.0051.2018 (10).ARBKmr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com 43-20 34th Street,Long Island City,NY 11101 TEL:800 76 STEAM FAX:718 472 3256 /9410 S.La Cienega Blvd.Inglewood CA 90301 TEL:800 72 STEAM FAX:310 216 2944 141/2" (368) 21/2" (64) 51/8"(130) 13/4" (45) 63/4"(171) 13/4" (45) 5"(127) 63/8" (162) 17/8"(48) 51/8" (130) 81/4" (210) 143/4" (375) 117/8" (302) Water Inlet Control &Acces- sory Connections Steam Outlet Safety Valve Manual Drain Valve Mr.Steam Standard Features •Stainless steel tank •Industrial,large diameter, serviceable heating element •Modular Plug and Play connections •Electronic water-levelcontrol system •Full-port drain valve. •Limited lifetime steam generator parts warranty Safety Features •Built-in,low-voltage 24-volt control •ASME safety valve Locating and Installing the Steam Generator Unit •Select a location as near as prac- tical to the steam room,within 60 feet.Typical locations in- clude:closet,vanity cabinet, heated attic or basement •Do not install steambath genera- tor inside the steam room. •Do not install steambath generator outdoors or wherever environmental conditions may affect the safety and/or perform- ance of the generator •Do not install steambath generator or plumbing lines in unheated attic or any locations where water could freeze Required Plumbing Steam Outlet (1/2"NPT)Safety Valve (3/4"NPT) Drain (1/2"NPT)Steam Head (1/2"NPT) Water Supply (3/8"NPT) Electrical All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code. Power Wiring 1.Check power voltage.Use 240V rated unit when supply matches rating of unit before installation. 2.Use minimum 90˚C/300V rated insulated copper conductors only,type THHN or equal sized in accordance with National Electrical Code and local electrical code for the Amps in Ampere Chart. If allowed by code,NM cable may require a larger wire size than as listed on the chart. 3.Connect suitably sized equipment grounding wire to ground terminal provided. 4.Install a separate circuit breaker between supply and unit.Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position. A M P E R E C H A R T MAX ROOM VOLTS WIRE SIZE MODEL NO.VOL.CU.FT.KW 1 PH AMPS (AWG) MS 90E 100 5.0 208 24 10 240 21 10 MODEL VOLTAGE*PHASE OPTIONS PROJECT INFORMATION MS90E B=208 1-Single Phase Express C=240 3-Three Phase Steam *Contact Mr. Steam for other voltages Notes: Location: Architect: Engineer: Contractor: Submitted By: Date: Required Equipment:iSteam, iTempoPlus or iTempo Control Optional Equipment:iGenie, AudioWizard, ChromaSteam, HomeWizard, Recessed Light, MS Light, MS Wallseat, AutoFlush, Drip Pan, AromaSteam, Chlorine Filter, FORM Shower Systems • Do not install steambath generator near flammable or corrosive materi- als or chemicals or in areas having a high concentration of chlorine • Install steambath generator on a solid and level surface or securely mounted to a wall using the key- hole slots provided. • Install steambath generator in an upright position only • Provide a minimum of (12) inches at both ends and top of the steam gen- erator or as required for servicing • Provide unions as required to facili- tate installation and disconnection of the steam generator. FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit. TS0041-90E REV 5.14 mr.steam® Technical Specifications______________________________________________________ Model MS 90E Serial Number 9000000 and higher • 60-minute electronic countdown shutdown with 75-minute limiting safety back-up Optional AutoFlush mr.steam®Technical Specifications AutoFlush® mr.steam® Sussman-Automatic Corp® hello@mrsteam.com www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944 AutoFlush Shown Fully Assembled Drain Valve DO NOT TURN OR REMOVE THE DRAIN VALVE (shown in the correct open position) Steam Generator Nipple Plumb to Drain Line AutoFlush Valve Box Contents • AutoFlush Valve with Cord • Installation instructions Operation The optional AutoFlush System fea- ture automatically drains the Mr.Steam®system following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation. Note: If the Express Steam®option has been installed, the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre-heat cycle. Our exclusive AutoFlush® automatically and electronically drains the system, providing CleanSteam... Every Time®and introduces fresh water. TS0011 REV 5.14mr.steam® Sussman-Automatic Corp® hello@mrsteam.com www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944 MODEL PROJECT INFORMATION MS 81500E Notes: Location: Architect: Engineer: Contractor: Submitted By: Date: FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit. mr.steam® T E C H N I C A L S P E C I F I C A T I O N S i TEMPO™CONTROLS iTempo™controls flush mount in the steam/shower enclosure through a 2 5⁄8”wide x 3 7⁄8”high hole.iTempo controls can also be surface mounted. iTempo™Controls Feature: •Solid brass decorative cover with choice of square or round styles in designer finishes •Digital display •Programmable temperature •AromaSteam steamhead in matching finish and shape •Compatibility with iGenie® •Soft touch keypad •Low voltage operation The iTempo controls are designed to be installed inside or outside the steam room but is primarily installed inside the steam room.If the control is installed inside the steam room the control must be located: •4-5 feet above the floor •in a location representative of the desired steam bathing temperatures.Do not locate the control above or near the steam head or direct steam emissions. •on a vertical wall The control cable length is 30 feet.Insure that the control and/or steam generator are located accordingly. An optional 60 ft.cable is available if required,PN 103990-60. If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS must be installed inside the steam room. 21/2” 41/2” 1/4” 3/8” 3/4” 1” 5” 5” 33/4” 12”long pigtail TS0006 Rev 5.14mr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com 43-20 34th Street,Long Island City,NY 11101 tel:1 800 76 STEAM fax:718 472 3256 9410 S.La Cienega Blvd.Inglewood CA 90301 tel:1 800 72 STEAM fax:310 216 2944 BOX CONTENTS: •iTempo™•Tube of Silicone Sealant •Steamhead •Owner’s Manual •Control Cable (30 ft.) MODEL SHAPE FINISH PROJECT INFORMATION MS iTempo RD Round BB - Brushed Bronze SQ Square BN - Brushed Nickel ORB - Oil Rubbed Bronze PB - Polished Brass PC - Polished Chrome PN - Polished Nickel RAW - Custom Plating Notes: Location: Architect: Engineer: Contractor: Submitted By: Date: Dimensional Information for the round and square controls: FOR ILLUSTRATIVE PURPOSES ONLY. IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit. 3” 23/4” 31/2” 3” 1” 0 3” 7/8” •Even distribution of steam while remaining cool to the touch •No field assembly required •No moving parts •Integrated aromatherapy oil well for in shower use Installing the Round &Square Steamhead STEAMHEAD INSTALLATION (1⁄2"NPT) IMPORTANT:Do not disassemble steamhead.Mr.Steam’s steam head is shipped fully assembled and requires no additional assembly. Because the steamhead and direct steam emissions are very hot,locate the steamhead where incidental contact by bather with the steamhead or direct steam emission cannot occur. NOTE:A 1.5”clearance hole around the steam pipe is needed to mount the steamhead. Locate steamhead 6-12 inches above floor,except for: •Tub/shower enclosures,install 6 inches above tub top edge. •For enclosures with acrylic or other non-heat resistant flooring install Acrylic Shield Part Number 103938 /10398SQ IMPORTANT NOTE:To preserve steam head finish,do not use wrench or other tools to tighten.DO NOT use abrasive cleansers or chemicals.Use only water with mild soap and a non-abrasive sponge. !C A U T I O N mr.steam®Technical Specifications AromaSteam Steamhead ROUND 103937 /SQUARE 104040 /ISTEAM104104 TS0010 REV 5.14mr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com 43-20 34th Street,Long Island City,NY 11101 tel:1 800 76 STEAM fax:718 472 3256 9410 S.La Cienega Blvd.Inglewood CA 90301 tel:1 800 72 STEAM fax:310 216 2944 Steam Supply Pipe End of pipe to be recessed 1/4"(without Acrylic Shield) 1/8"(with Acrylic Shield) 1/8"minimum clearance required when Acrylic Shield is used.See installation instructions provided with the Acrylic Shield. Apply with silicone or equal sealant as required for moisture seal. Use Teflon®or equal sealant on pipe threads MODEL FINISH PROJECT INFORMATION 103937-Round BB Brushed Bronze 104040-Square BN Brushed Nickel 104104-iSteam* ORB Oil Rubbed Bronze PB Polished Brass PC Polished Chrome PN Polished Nickel RAW Custom Plating BLK Black** WH White** Location: Architect: Engineer: Contractor: Submitted By: Date: Notes: *iSteam steamhead is only available in black and white ** Black and white finish are only available with iSteam steamhead Consult with supplier of acrylic, fiberglass and other non-heat resistant enclosures for recommended steamhead location. Use Acrylic Shield PN 103938/ 103938SQ. See instructions provided with steam shield. (An acrylic shield is not available for the iSteam steamhead.) !C A U T I O N FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit.