HomeMy WebLinkAboutFile Documents.185 Forge Rd.0051.2018 (10).ARBKmr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com
43-20 34th Street,Long Island City,NY 11101 TEL:800 76 STEAM FAX:718 472 3256 /9410 S.La Cienega Blvd.Inglewood CA 90301 TEL:800 72 STEAM FAX:310 216 2944
141/2"
(368)
21/2"
(64)
51/8"(130)
13/4"
(45)
63/4"(171)
13/4"
(45)
5"(127)
63/8"
(162)
17/8"(48)
51/8"
(130)
81/4"
(210)
143/4"
(375)
117/8"
(302)
Water Inlet
Control &Acces-
sory Connections
Steam Outlet
Safety Valve
Manual Drain Valve
Mr.Steam Standard Features
•Stainless steel tank
•Industrial,large diameter,
serviceable heating element
•Modular Plug and Play connections
•Electronic water-levelcontrol system
•Full-port drain valve.
•Limited lifetime steam generator
parts warranty
Safety Features
•Built-in,low-voltage 24-volt control
•ASME safety valve
Locating and Installing the Steam Generator Unit
•Select a location as near as prac-
tical to the steam room,within
60 feet.Typical locations in-
clude:closet,vanity cabinet,
heated attic or basement
•Do not install steambath genera-
tor inside the steam room.
•Do not install steambath
generator outdoors or wherever
environmental conditions may
affect the safety and/or perform-
ance of the generator
•Do not install steambath
generator or plumbing lines in
unheated attic or any locations
where water could freeze
Required Plumbing
Steam Outlet (1/2"NPT)Safety Valve (3/4"NPT)
Drain (1/2"NPT)Steam Head (1/2"NPT)
Water Supply (3/8"NPT)
Electrical
All electrical wiring to be installed by a qualified
licensed electrician in accordance with National
Electrical Code and local electrical code.
Power Wiring
1.Check power voltage.Use 240V rated unit when
supply matches rating of unit before installation.
2.Use minimum 90˚C/300V rated insulated copper
conductors only,type THHN or equal sized in
accordance with National Electrical Code and local
electrical code for the Amps in Ampere Chart.
If allowed by code,NM cable may require a larger
wire size than as listed on the chart.
3.Connect suitably sized equipment grounding wire to
ground terminal provided.
4.Install a separate circuit breaker between supply and
unit.Provide a power supply disconnect within
sight of the steam generator or one that is capable
of being locked in the open position.
A M P E R E C H A R T
MAX ROOM VOLTS WIRE SIZE
MODEL NO.VOL.CU.FT.KW 1 PH AMPS (AWG)
MS 90E 100 5.0 208 24 10
240 21 10
MODEL VOLTAGE*PHASE OPTIONS PROJECT INFORMATION
MS90E B=208 1-Single Phase Express
C=240 3-Three Phase Steam
*Contact Mr. Steam for other voltages
Notes:
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Required Equipment:iSteam,
iTempoPlus or iTempo Control
Optional Equipment:iGenie, AudioWizard, ChromaSteam, HomeWizard, Recessed Light, MS
Light, MS Wallseat, AutoFlush, Drip Pan, AromaSteam, Chlorine Filter, FORM Shower Systems
• Do not install steambath generator
near flammable or corrosive materi-
als or chemicals or in areas having
a high concentration of chlorine
• Install steambath generator on a
solid and level surface or securely
mounted to a wall using the key-
hole slots provided.
• Install steambath generator in an
upright position only
• Provide a minimum of (12) inches at
both ends and top of the steam gen-
erator or as required for servicing
• Provide unions as required to facili-
tate installation and disconnection
of the steam generator.
FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance
Manual or refer to the manual provided with the unit.
TS0041-90E REV 5.14
mr.steam®
Technical Specifications______________________________________________________
Model MS 90E
Serial Number 9000000 and higher
• 60-minute electronic countdown
shutdown with 75-minute limiting
safety back-up
Optional
AutoFlush
mr.steam®Technical Specifications
AutoFlush®
mr.steam® Sussman-Automatic Corp® hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
AutoFlush Shown Fully Assembled
Drain Valve
DO NOT TURN OR REMOVE THE DRAIN VALVE
(shown in the correct open position)
Steam Generator
Nipple
Plumb to
Drain Line
AutoFlush Valve
Box Contents
• AutoFlush Valve with Cord
• Installation instructions
Operation
The optional AutoFlush System fea-
ture automatically drains the
Mr.Steam®system following each use.
A time delay allows the water to cool
down (about two hours) before it
drains by gravity for a safe and gentle
operation.
Note: If the Express Steam®option
has been installed, the AutoFlush will
drain for ten minutes then refill with
fresh water to begin the pre-heat
cycle.
Our exclusive AutoFlush® automatically and electronically drains the system,
providing CleanSteam... Every Time®and introduces fresh water.
TS0011 REV 5.14mr.steam® Sussman-Automatic Corp® hello@mrsteam.com www.mrsteam.com
43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256
9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944
MODEL PROJECT INFORMATION
MS 81500E
Notes:
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and
Maintenance Manual or refer to the manual provided with the unit.
mr.steam®
T E C H N I C A L S P E C I F I C A T I O N S
i TEMPO™CONTROLS
iTempo™controls flush mount in the steam/shower enclosure through a
2 5⁄8”wide x 3 7⁄8”high hole.iTempo controls can also be surface mounted.
iTempo™Controls Feature:
•Solid brass decorative cover with choice of square or
round styles in designer finishes
•Digital display
•Programmable temperature
•AromaSteam steamhead in matching finish and shape
•Compatibility with iGenie®
•Soft touch keypad
•Low voltage operation
The iTempo controls are designed to be installed inside or outside
the steam room but is primarily installed inside the steam room.If the
control is installed inside the steam room the control must be located:
•4-5 feet above the floor
•in a location representative of the desired steam bathing
temperatures.Do not locate the control above or near the
steam head or direct steam emissions.
•on a vertical wall
The control cable length is 30 feet.Insure that the control and/or
steam generator are located accordingly.
An optional 60 ft.cable is available if required,PN 103990-60.
If the control is installed outside the steam room a Remote Temperature
Probe Part Number MSTS must be installed inside the steam room.
21/2”
41/2”
1/4”
3/8”
3/4”
1”
5”
5”
33/4”
12”long
pigtail
TS0006 Rev 5.14mr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com
43-20 34th Street,Long Island City,NY 11101 tel:1 800 76 STEAM fax:718 472 3256
9410 S.La Cienega Blvd.Inglewood CA 90301 tel:1 800 72 STEAM fax:310 216 2944
BOX CONTENTS:
•iTempo™•Tube of Silicone Sealant
•Steamhead •Owner’s Manual
•Control Cable (30 ft.)
MODEL SHAPE FINISH PROJECT INFORMATION
MS iTempo RD Round BB - Brushed Bronze SQ Square BN - Brushed Nickel ORB - Oil Rubbed Bronze PB - Polished Brass PC - Polished Chrome PN - Polished Nickel RAW - Custom Plating
Notes:
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Dimensional
Information for the
round and square
controls:
FOR ILLUSTRATIVE PURPOSES ONLY.
IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download
the Installation, Operation and Maintenance Manual or refer to the
manual provided with the unit.
3”
23/4”
31/2”
3”
1”
0 3”
7/8”
•Even distribution of steam while
remaining cool to the touch
•No field assembly required
•No moving parts
•Integrated aromatherapy oil
well for in shower use
Installing the Round &Square Steamhead
STEAMHEAD INSTALLATION (1⁄2"NPT)
IMPORTANT:Do not disassemble steamhead.Mr.Steam’s steam
head is shipped fully assembled and requires no additional assembly.
Because the steamhead and direct steam emissions
are very hot,locate the steamhead where incidental contact by
bather with the steamhead or direct steam emission cannot occur.
NOTE:A 1.5”clearance hole around the steam pipe is needed
to mount the steamhead.
Locate steamhead 6-12 inches above floor,except for:
•Tub/shower enclosures,install 6 inches above tub top edge.
•For enclosures with acrylic or other non-heat resistant flooring
install Acrylic Shield Part Number 103938 /10398SQ
IMPORTANT NOTE:To preserve steam head finish,do not
use wrench or other tools to tighten.DO NOT use abrasive
cleansers or chemicals.Use only water with mild soap and a
non-abrasive sponge.
!C A U T I O N
mr.steam®Technical Specifications
AromaSteam Steamhead ROUND 103937 /SQUARE 104040 /ISTEAM104104
TS0010 REV 5.14mr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com
43-20 34th Street,Long Island City,NY 11101 tel:1 800 76 STEAM fax:718 472 3256
9410 S.La Cienega Blvd.Inglewood CA 90301 tel:1 800 72 STEAM fax:310 216 2944
Steam
Supply Pipe
End of pipe to be recessed
1/4"(without Acrylic Shield)
1/8"(with Acrylic Shield)
1/8"minimum clearance
required when Acrylic Shield
is used.See installation
instructions provided with the
Acrylic Shield.
Apply with silicone
or equal sealant as
required for
moisture seal.
Use Teflon®or
equal sealant on
pipe threads
MODEL FINISH PROJECT INFORMATION 103937-Round BB Brushed Bronze 104040-Square BN Brushed Nickel 104104-iSteam* ORB Oil Rubbed Bronze PB Polished Brass PC Polished Chrome PN Polished Nickel RAW Custom Plating BLK Black** WH White**
Location:
Architect:
Engineer:
Contractor:
Submitted By:
Date:
Notes:
*iSteam steamhead is only available in black and white ** Black and white finish are only available with iSteam steamhead
Consult with supplier of acrylic, fiberglass
and other non-heat resistant enclosures for recommended
steamhead location. Use Acrylic Shield PN 103938/
103938SQ. See instructions provided with steam shield. (An
acrylic shield is not available for the iSteam steamhead.)
!C A U T I O N
FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION
visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and
Maintenance Manual or refer to the manual provided with the unit.