Loading...
HomeMy WebLinkAboutFile Documents.185 Forge Rd.0051.2018 (15).ARBKmr.steam® Technical Specifications iSteam®3 iSteam controls flush mount in the steam/shower enclosure through a 5-1/4” wide x 3-9/16” high hole. iSteam controls can also be surface mounted. They are suitable for use with SteamLinx™mobile app control. iSteam controls are suitable for use inside or outside the steam/shower enclosure, featuring: • Full color LCD touch screen • Programmable temperature • Programmable time • Eight user presets • AromaSteam, ChromaSteam3 and AudioSteam3 controls TS0073 REV 7.17mr.steam® Sussman-Automatic Corp® hello@mrsteam.com www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 tel: 1 800 76 STEAM fax: 718 472 3256 9410 S. La Cienega Blvd. Inglewood CA 90301 tel: 1 800 72 STEAM fax: 310 216 2944 Box Contents: • iSteam3 • Owner’s Manual • Control Cable (30 ft.) • Rough-In Box • Steamhead • Optional Surface • Tube of Silicone Sealant Mount Gasket 10:06 AM ACCESSORIES SETTINGS START F 12:16 PM START 97 6 1⁄8” 41⁄2” 13⁄8” Wall location for flush mount Wall location for optional surface mount Pigtail (81⁄2”) Dimensional Information The iSteam controls are designed to be installed inside or outside the steam room but is primarily installed in- side the steam room. If the control is installed inside the steam room the control must be located: • 4-5 feet above the floor • In a location representative of the desired steam bathing temperatures near the bather seating area. Do not locate the control above or near the steam- head or direct steam emissions. • On a vertical wall The control cable length is 30 feet. Insure that the con- trol and/ or steam generator are located accordingly. An optional 60 ft. cable is available if required, PN 104117-60. If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS must be installed inside the steam room. • Passcode to prevent uninten- tional use of steam bath • Includes AromaSteam Steam- head in white or black • Compatible with SteamLinx • Low voltage operation MODEL FINISH PROJECT INFORMATION iSteam3 Black White Notes: Location: Architect: Engineer: Contractor: Submitted By: Date: FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit. 03/06/2018 17" (432) 21/2" (64) 47/8" (124) 2" (51) 77/8" (200) 71/4" (184) 97/8" (251) 151/2" (394) 183/4" (476) 11/4" (32) 6" (152) 63/8" (162) 21/4" (57) Water Inlet Control & Acces- sory Connections Steam Outlet Safety Valve Manual Drain Valve Optional AutoFlush mr.steam®Sussman-Automatic Corp®hello@mrsteam.com www.mrsteam.com 43-20 34th Street, Long Island City, NY 11101 TEL:800 76 STEAM FAX:718 472 3256 /9410 S. La Cienega Blvd. Inglewood CA 90301 TEL: 800 72 STEAM FAX:310 216 2944 Mr.Steam Standard Features • Stainless steel tank • Industrial, large diameter, serviceable heating element • Modular Plug and Play connections • Electronic water-levelcontrol system • Full-port drain valve. • Limited lifetime steam generator parts warranty Safety Features • Built-in, low-voltage 24-volt control • ASME safety valve Locating and Installing the Steam Generator Unit • Select a location as near as practical to the steam room, within 60 feet. Typical locations include: closet, van- ity cabinet, heated attic or basement • Do not install steambath generator inside the steam room. • Do not install steambath generator outdoors or wherever environmental conditions may affect the safety and/ or performance of the generator • Do not install steambath generator or plumbing lines in unheated attic or any locations where water could freeze • Do not install steambath generator near flammable or corrosive materials Required Plumbing Steam Outlet (1/2" NPT)Safety Valve (3/4" NPT) Drain (1/2" NPT)Steam Head (1/2" NPT) Water Supply (3/8" NPT) Electrical All electrical wiring to be installed by a qualified licensed electrician in accordance with National Electrical Code and local electrical code. Power Wiring 1.Check power voltage. Use 240V rated unit when supply matches rating of unit before installation. 2. Use minimum 90˚ C/300V rated insulated copper conductors only, type THHN or equal sized in accordance with National Electrical Code and local electrical code for the Amps in Ampere Chart. If allowed by code, NM cable may require a larger wire size than as listed on the chart. 3. Connect suitably sized equipment grounding wire to ground terminal provided. 4.Install a separate circuit breaker between supply and unit. Provide a power supply disconnect within sight of the steam generator or one that is capable of being locked in the open position. A M P E R E C H A R T MAX ROOM VOLTS WIRE SIZE MODEL NO.VOL. CU.FT.KW 1 PH AMPS (AWG) MS Super1E 475 10.0 208 49 6 240 42 8 MODEL VOLTAGE*PHASE OPTIONS PROJECT INFORMATION MSSuper1E B=208 1-Single Phase Express C=240 3-Three Phase Steam *Contact Mr. Steam for other voltages Notes: Location: Architect: Engineer: Contractor: Submitted By: Date: Required Equipment:iSteam, or iTempoPlus Control Optional Equipment:iGenie, AudioWizard, ChromaSteam, HomeWizard, Recessed Light, MS Light, MS Wallseat, AutoFlush, Drip Pan, AromaSteam, Chlorine Filter, FORM Shower Systems or chemicals or in areas having a high concentration of chlorine • Install steambath generator on a solid and level surface or securely mounted to a wall using the keyhole slots provided. • Install steambath generator in an upright position only • Provide a minimum of 12 inches inches at both ends and top of the steam generator or as required for servicing. Alternately provide unions to facilitate installation and disconnection of the steam generator. • The minimum clearance from com- bustible surfaces is zero all around. FOR ILLUSTRATIVE PURPOSES ONLY.IMPORTANT NOTE: FOR SAFE AND TROUBLE FREE INSTALLATION visit mrsteam.com or scan the QR code before installation to download the Installation, Operation and Maintenance Manual or refer to the manual provided with the unit. TS0041-S1E REV 8.15 mr.steam® Technical Specifications______________________________________________________ Model MS Super1E Serial Number 9000000 and higher • 60-minute electronic countdown shutdown with 75-minute limiting safety back-up 03/06/2018