Loading...
HomeMy WebLinkAboutFile Documents.301 E Hopkins Ave.0037.2018 (7).ACBK Response We will need to investigate, but it is our belief that there is a Slab under the Planter. If Roof assembly needs to be replaced and reasonable cost we will proceed. If not, we will leave the planter existing to remain. If the planter removal proceeds we will provide applicable roof assembly and all transition details. This has been discussed between Rob Ittner and Justin Hahn. 05/07/2018 We are now proposing not to make any Changes to the existing Lights that are in place. Other than Dimmers Switches that work with LED light bulbs. This is the Existing lighting in the Space Note- The Dotted Lines are not correct but the Switches are color coded. 05/07/2018 Comment on Grease Trap Grease Trap Spec for Dish Washer Attached 1.16 Gal cycle Requires the Smallest Trap Mad We will Size a 20-30 Gal Grease trap Spec for Dish Washer Attached We will have a trap door under the Floor Exact location TBD in field 05/07/2018 Sink Hight For Accessibility Note that it is a wait station Sink not for public Use Question about ANSI Accessibility Counter Hight to be at 36” This is a wait station not Public Use Comments on Hood Note this is for Venting Dishwasher Not Cooking Vent would vent out back window Two possible Options Included Spec Sheet included See Below \ This is a new Layout for the area around plumbing 05/07/2018 05/07/2018 Nothing Needed here because we are going with Existing Lighting 05/07/2018 Hood Specs Option 1 05/07/2018 Hood Specs Option 2 05/07/2018 Grease Trap Specs 05/07/2018 Dish Washer Specs 05/07/2018 Dish Washer Specs Page 2 05/07/2018