Loading...
HomeMy WebLinkAboutFile Documents.433 W Bleeker St.0170.2017 (2).ARBK0170.2017.ARBK_Zoning_2 Page: [4] Z-102 FLOOR AREA CALCULATIONS Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf Revise after wall calculations have been revised 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf (9) Page: [4] Z-102 FLOOR AREA CALCULATIONS Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf The height of these Subgrade walls do not match the height of the walls shown in your sections. Please match each wall with its structure above to arrive at a wall height. Recalculate sub-grade FA Page: [7] A-001 SITE PLAN Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf Please show that these meet the rules for Projections into setbacks. Page: [11] A-104 ROOF PLAN Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf You do not need to measure to the bottom of a window well unless the window well is more than 100 sq ft. Neither of these wells are, therefore please revise your measurement to grade. Page: [11] A-104 ROOF PLAN Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf You transposed the 9 & 7 Page: [11] A-104 ROOF PLAN Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf These points should be identical in elevation because they are both sides of an equilateral triangle - revise. Page: [14] A-301 SECTIONS Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf 10'-8 3/8" 480.38 SQ. FT.(15.33 SQ. FT. + 465.05 SQ. FT.) 486 SQ. FT.(2340 SQ. FT. x 15%) 0.00 147.77 SQ. FT. 2024.64 SQ. FT. 117.94 SQ. FT. 1191.38 SQ. FT. 0.00 3481.74 SQ. FT. 3490.00 SQ. FT.(3240 SQ. FT. + 250 SQ. FT. TDR PROPOSED Revise after wall calculations have been revised FLOOR AREA CALCULATIONS PROPOSED LOWER LEVEL EXPOSED WALL AREA CALCULATIONS WALL LABEL WALL AREA EXPOSED WALL AREA (SQ. FT.) 1 241.56 SQ. FT.02300.65 SQ. FT.47.34 SQ. FT.3 39.97 SQ. FT.0 4 434.46 SQ. FT.20.78 SQ. FT. 1 1 A B E D F G H C 2 300.65 SQ. FT. 8.69 SQ. FT.30.85 SQ. FT.152.93 SQ. FT.105.14 SQ. FT.160.32 SQ. FT. 64.30 SQ. FT.128.60 SQ. FT.300.65 SQ. FT. 47.34 SQ. FT.20.78 SQ. FT. 47.34 SQ. FT. 23'-2"28'-10" 6'-10" 4'-2"41'-8" 3'-0" 10"15'-1 1/2"2'-11 1/2"11'-1"14'-8"10'-1"15'-4 1/2" 6'-2"12'-4"28'-10"6'-10" 10'-5 1 / 8 " 20.78 SQ. FT. 6'-11 1 / 8 " 115.57 SQ. FT.157.71 SQ. FT. 434.46 SQ. FT.39.97 SQ. FT.6'-11 1/8"6'-11 1 / 8 "6'-11 1/8"3'-6"3'-0"3'-6" 6'-10"3'-6" 3'-0"3'-6"241.56 SQ. FT. 10'-5 1 / 8 " 10'-5 1/ 8 " 431 5 6 7 8 9 10 11 12 13 14 EXPOSED WALL AREACOVERED WALL AREA KEY: 1 A B LOWER LEVELEXPOSED WALL AREA CALCS. 1/8" = 1'-0" 4Z-102 The height of theseSubgrade walls donot match the heightof the walls shown inyour sections. Please match eachwall with its structureabove to arrive at awall height. Recalculatesub-grade FA 7912#4 REBARDISTURBED T.O. FINISH T.O. CONC EL. = 100' 1-3/4"10'-0"5'-0" WINDOW WELL & ESCAPE LADDER AIR HANDLING UNITS/ GAS METER LOCATION 5'-0"COM 5' SID Please show that these meet the rules for Projections into setbacks. ELEVATION #GRADE ELEVATION 7910.92' 02 03 04 05 06 07 01 (EXISTING) ROOF HEIGHT OVER TOPOGRAPHY GRADE ELEVATION(PROPOSED)MOST ROOF HEIGHTOVER TOPO ACTUALOVER MOST RESTRICTIVEHEIGHTRESTRICTIVE 18' 6"7903.21' 7910' PROPOSED 7921.71' PROPOSED 23' 6"7926.71' PROPOSED 15' 4-17/32"7925.38' SURVEYORVERIFICATION 08 09 10 7911.79' 7910.12' 7910' 7910.66' 7911.04' 7911.43' 7911.60' 9710.89' 7910.64' 7903.21' 7910.5'EXISTING 23' 1-3/8"7933.11' 7911'EXISTING 24' 10-13/16"7935.56' 7911'PROPOSED 24' 6-3/16"7935.52' 7911'PROPOSED 23' 8-21/32"7934.72' 7911'PROPOSED 23' 8-21/32"7934.72' N/A EXISTING 23' 11-15/16"7934.85' N/A EXISTING 24' 10-7/16"7935.51' 3 4 5 6 25'-0 1/2"15'-10"4'-1 1/2"80'-0" 2A302 8:12 8:12 DOWNSPOUT/GUTTERS SNOW FENCERDRAIL MINAFF 06 07 RIDGE SNOWFENCESLOPED ROOF ASCLASS 'A' ASSEMBLY08 ROOF GENE 1. 2. ROOF MATE ALL DIMENS You do not need tomeasure to thebottom of a windowwell unless thewindow well is morethan 100 sq ft. Neither of these wellsare, therefore pleaserevise yourmeasurement tograde. 02 03 04 05 06 07 791 08 09 10 7911.79' 7910.12' 7910' 7910.66' 7911.04' 7911.43' 7911.60' 9710.89' 7910.64' 790 791 791 791 791 791 N/A N/A 3 4 25'-0 1/2" 80'-0" You transposed the 9 & 7 7910' PROPOSED 23' 6"7926.71' PROPOSED 15' 4-17/32"7925.38' 79' 12' ' 66' 04' 43' 60' 89' 64' 7903.21' 7910.5'EXISTING 23' 1-3/8"7933.11' 7911'EXISTING 24' 10-13/16"7935.56' 7911'PROPOSED 24' 6-3/16"7935.52' 7911'PROPOSED 23' 8-21/32"7934.72' 7911'PROPOSED 23' 8-21/32"7934.72' N/A EXISTING 23' 11-15/16"7934.85' N/A EXISTING 24' 10-7/16"7935.51' 4 5 6 15'-10"4'-1 1/2" 2A302 07 These points should be identical in elevation because they are both sides of an equilateral triangle - revise. MEDIA 00711'-5 1/4"A501 10'-2 1/4"10'-8 3/8"WALL CALCULATIONS HAVE BEEN REVISED. SEE SHEET Z-102 WALL CALCULATIONS HAVE BEEN REVISED. HEIGHTS HAVE BEEN UPDATED TO MATCH STRUCTURE. SEE SHEET Z-102 AIR HANDELING UNITS HAVE BEEN REMOVED FROM SETBACK. SEE SHEET A-001 MEASUREMENTS AT POINTS 01 & 02 HAVE BEEN REVISED. NOTE HAS ALSO BEEN ADDED TO "ROOF HEIGHT OVER TOPO." CHART. SEE SHEETS: A-104, A-201, A-202 TYPO HAS BEEN FIXED. CORRECT EXISTING GRADE ELEVATION FOR POINT #09 HAS BEEN UPDATED SEE SHEET A-104 TYPO HAS BEEN FIXED. CORRECT ROOF HEIGHT OVER TOPO UPDATED. SEE SHEET A-104 STRUCTURE TO STRUCTURE HEIGHT BELOW GARAGE HAS BEEN UPDATED TO BE 9'-10 3/4" SEE SHEET Z-101 & A-301 04/03/2018 Page: [14] A-301 SECTIONS Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf 9'-7 27/32" Page: [15] A-302 SECTIONS Checkmark: Unchecked Author: jimp File Name: 16029.00_433 W. BLEEKER_PERMIT ARCH_COMMENT RESPONSE_2018.01.16.pdf 10'-4 29/32" Page: M201 MAIN LEVEL MECHANICAL PI Checkmark: Unchecked Author: jimp File Name: 16095-Permit Drawings-062717.pdf For this unit to remain within the rear setback, it must be no taller than 30" above finished grade. Please provide cut sheets and details to show that this unit is code compliant, or move it out of the setback. 16095-Permit Drawings-062717.pdf (1) Page: [4] C3 GRADING AND UTILITIES Checkmark: Unchecked Author: jimp File Name: 2018.01.10.433Bleeker.CommentResponsesCivilS et.pdf As per 26.575.020.E.5.m), Allowed Projections into Setbacks, Fire pits are not allowed in front yards. Please remove this feature. If the owner wants a fire pit on this patio it needs to be a self contained unit without any permanent connections. 2018.01.10.433Bleeker.CommentResponsesCivilSet.pdf (1) Page: S.2.01 Foundation Plan Checkmark: Unchecked Author: jimp File Name: bleeker permit REV 1-16-2018 stamped.pdf bleeker permit REV 1-16-2018 stamped.pdf (2) Page: S.2.01 Foundation Plan Checkmark: Unchecked Author: jimp File Name: bleeker permit REV 1-16-2018 stamped.pdf MEDIA 007 EGRESS WINDOW @ WELL. *<44" A.F.F CLEAR OPENING 3'-6"9'-7 27/32"BEDROOM 3 011TH 3 09 EVEL WALLS N 11'-6"A501 10'-4 29/32"For this unit to remain within the rear setback, it must be no taller than 30" above finished grade. Please provide cut sheets and details to show that this unit is code compliant, or move it out of the setback. As per 26.575.020.E.5.m),Allowed Projections into Setbacks, Fire pits are not allowed in front yards. Pleaseremove this feature. If theowner wants a fire pit on this patio it needs to be a self contained unit without anypermanent connections.3'-4 1/8"3'-8" This feature is within a setback. Reduce to no more than 3'x3' to match architecturals 3'-4 1/32"3'-8" This feature is within a setback. Reduce to no more than 3'x3' to match architecturals STRUCTURE TO STRUCTURE HEIGHT BELOW GARAGE HAS BEEN UPDATED TO BE 9'-10 3/4" SEE SHEET Z-101 & A-301 STRUCTURE TO STRUCTURE HEIGHT BELOW GARAGE HAS BEEN UPDATED TO BE 9'-10 3/4" SEE SHEET Z-101 & A-301 NOTES & DIMENSIONS HAVE BEEN ADDED TO LOWER LEVEL FLOOR PLAN. WHEN FINISHED WINDOW WELL MUST BE EXACTLY 3'x3' SEE SHEET A-103 NOTES & DIMENSIONS HAVE BEEN ADDED TO LOWER LEVEL FLOOR PLAN. WHEN FINISHED WINDOW WELL MUST BE EXACTLY 3'x3' SEE SHEET A-103 NO FIREPLACE, SEE ARCH. and LANDSCAPE 04/03/2018