HomeMy WebLinkAboutFile Documents.520 E Hyman Ave.0051.2018 (3).ACBKREScheck Software Version 4.6.5
Compliance Certificate
Project Penthouse Remodel
Energy Code:2015 IECC
Location:Aspen, Colorado
Construction Type:Multi-family
Project Type:Alteration
Climate Zone:7 (9922 HDD)
Permit Date:
Construction Site:
520 E Hyman, Unit 3AB
Aspen, CO 81611
Owner/Agent:
Salt Parks West LLC
520 E Hyman Ave
Aspen, CO 81611
Designer/Contractor:
Bryan May
rowland+broughton
520 E Hyman
Aspen, CO 81611
970-544-9006
bmay@rowlandbroughton.com
Permit Number:
Compliance: Passes using prescriptive requirements for alteration projects
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
R2 Assembly - Grids 1-3: Flat Ceiling or Scissor Truss 1,635 13.6 25.0 0.025 40
Skylight 1: Wood Frame:Double Pane with Low-E 9 0.550 5
Skylight 2: Wood Frame:Double Pane with Low-E 9 0.550 5
Skylight 3: Wood Frame:Double Pane with Low-E 9 0.550 5
R5 Assembly - Grids D-H, 3-5: Flat Ceiling or Scissor Truss 985 6.8 30.0 0.026 26
R6 Assembly - Grids H-K, 3.7-5: Flat Ceiling or Scissor Truss 157 6.8 30.0 0.026 4
R7 - Existing Sloped Roof: Cathedral Ceiling
Exemption: Framing cavity filled with insulation
---------------
Skylight 4: Wood Frame:Double Pane with Low-E 12 0.550 7
Skylight 4 copy 1: Wood Frame:Double Pane with Low-E 12 0.550 7
Skylight 4 copy 1: Wood Frame:Double Pane with Low-E 12 0.550 7
Skylight 4 copy 2: Wood Frame:Double Pane with Low-E 12 0.550 7
Project Title: Penthouse Remodel
Data filename: P:\Proj-2017\21713.00_Kagan\02_Project Info\04_Building Permit\02_REScheck\Kagan.rck Page 1 of 2
05/11/18Report date:
5: Wood Framed Double Pane with Low-E
6: Wood Framed Double Pane with Low-E
7: Wood Framed Double Pane with Low-E
05/11/2018
05/16/2018
justinh
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: Penthouse Remodel
Data filename: P:\Proj-2017\21713.00_Kagan\02_Project Info\04_Building Permit\02_REScheck\Kagan.rck Page 2 of 2
05/11/18Report date:
05/11/2018Bryan May, Architect, Rowland+Broughton
05/11/2018
05/16/2018
justinh