HomeMy WebLinkAboutFile Documents.63 Smuggler Grove Rd.0049.2018 (2).ARBKHOUSING TRIM & ACCESSORIES MATERIAL IN.
A1 4" RECESSED ADJUSTABLE
DOWNLIGHT, 40-DEG TILT,
5.4" DEPTH IC RATED,
TRIMLESS SQUARE BEVEL
LF
ILLUMINATION
HVS-1BA-S-
015MR16X-AD-TT-1-IC
9062-MW WHITE (1) 7W 12V MR16, 450
LUMENS, (VERIFY
CCT),
EXPERTCOLOR BY
PHILIPS
HIGH-EFFICACY:
LED < 15W
61 LPW @ 7W
INTEGRAL 12V
MAGNETIC LOW
VOLTAGE
DIMMING
TRANSFORMER
MLV DIM RECESSED
FLANGELESS
GYP ≤ 1"
A2 4X8" RECESSED ADJUSTABLE
DOWNLIGHT WITH 2 HEADS,
40-DEG TILT, 5.5" DEPTH IC
RATED, TRIMLESS SQUARE
BEVEL
LF
ILLUMINATION
HVS-2BA-S-
015MR16X-AD-TT-1-IC
9604-MW WHITE (2) 7W 12V MR16, 450
LUMENS, (VERIFY
CCT),
EXPERTCOLOR BY
PHILIPS
HIGH-EFFICACY:
LED < 15W
122 LPW @ 14W
INTEGRAL 12V
MAGNETIC LOW
VOLTAGE
DIMMING
TRANSFORMER
MLV DIM RECESSED
FLANGELESS
GYP ≤ 1"
C (BY INTERIOR
DESIGNER)
CEILING MOUNT CLOSET FIXTURE BY INTERIOR DESIGNER - - - NON-EFFICIENT - - - - -
L1 SURFACE MOUNTED LED
STRIP IN LENSED ALUMINUM
CHANNEL, 1/2" HEIGHT, 5/8"
WIDTH
PARADIGM LED PL-AMC-1612;
PL-OLC-1612;
PL-EC-1612;
PL-ECL-1612
PL-FLEXSR590-
(VERIFY CCT)-INT-24
ALUMINUM
(HIDDEN)
LED, 4.5W/FT 24V,
420 LM/FT, (VERFY
CCT), +90 CRI
HIGH-EFFICACY:
LED < 15W
93 LPW @ 4.5W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SURFACE
MOUNT
- -
L2
(WET)
SURFACE MOUNTED LED
STRIP IN LENSED ALUMINUM
CHANNEL, 1/2" HEIGHT, 5/8"
WIDTH; SILICONE ENDCAPS
FOR WET RATING
PARADIGM LED PL-AMC-1612;
PL-OLC-1612;
PL-EC-1612;
PL-ECL-1612
SILICONE FOR WET
RATING
PL-FLEXSR590-
(VERIFY CCT)-INT-24
ALUMINUM
(HIDDEN)
LED, 4.5W/FT 24V,
420 LM/FT, (VERFY
CCT), +90 CRI
HIGH-EFFICACY:
LED < 15W
93 LPW @ 4.5W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SURFACE
MOUNT
- - *APPLY SILICONE PER MFR
RECOMMENDATIONS FOR WET
RATING
*CONSULT MFR REGARDING PRE-
MADE LENGTHS
L3
(HIGH
OUTPUT)
SURFACE MOUNTED HIGH-
OUTPUT LED STRIP IN
LENSED CHANNEL, 1" WIDTH,
5/8" HEIGHT
PARADIGM LED PL-AMC-2415;
PL-OLC-2415;
PL-EC-2415;
PL-ECL-2415
PL-FLEXDR590-
(VERIFY CCT)-INT-24
ALUMINUM
(HIDDEN)
LED, 9W/FT 24V, 850
LM/FT, (VERFY CCT),
+90 CRI
HIGH-EFFICACY:
LED < 15W
94 LPW @ 9W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SURFACE
MOUNT
- -
L4 SURFACE MOUNTED LED
STRIP IN ANGLED, LENSED
ALUMINUM CHANNEL, 5/8"
PROFILE
PARADIGM LED PL-AMC-1616;
PL-OLC-1616;
PL-EC-1616;
PL-ECL-1616
PL-FLEXDR590-
(VERIFY CCT)-INT-24
ALUMINUM
(HIDDEN)
LED, 4.5W/FT 24V,
420 LM/FT, (VERFY
CCT), +90 CRI
HIGH-EFFICACY:
LED < 15W
93 LPW @ 4.5W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SURFACE
MOUNT
- -
L5
(CLOSET)
SURFACE MOUNTED LED
STRIP IN LENSED ALUMINUM
CHANNEL - CHANNEL SHAPE
TBD PER CLOSET DETAIL;
FACTORY ASSEMBLES TO
LENGTH WITH CLOSET
RATED STICKER
PARADIGM LED PL-CL-(VERIFY CCT)-
24-DIM-(SHAPE)-
(LENGTH)
PL-CL-EC-(SHAPE)
PL-CL-ECL-(SHAPE)
ALUMINUM
(HIDDEN)
LED, 4.5W/FT 24V,
420 LM/FT, (VERFY
CCT), +90 CRI
HIGH-EFFICACY:
LED < 15W
93 LPW @ 4.5W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SURFACE
MOUNT
- -
L6
(STAIRS)
SURFACE MOUNTED LED
STRIP IN LENSED ALUMINUM
CHANNEL, 1/2" HEIGHT, 5/8"
WIDTH; BLACK FINISH - LIGER
LENS
PARADIGM LED
+ KLUS LED
17031 - LIGER LENS
B1718_K(LENGTH) -
BLACK EXTRUSION
PDS4
PL-FLEXSR590-
(VERIFY CCT)-INT-24
BLACK LED, 4.5W/FT 24V,
420 LM/FT, (VERFY
CCT), +90 CRI
HIGH-EFFICACY:
LED < 15W
93 LPW @ 4.5W
REMOTE 24V
MAGNETIC LOW
VOLTAGE
DIMMING DRIVER
MLV DIM SEE ARCH.
STAIR DETAIL
- -
P (BY INTERIOR
DESIGNER)
SUSPENDED DECORATIVE PENDANT BY INTERIOR DESIGNER - - NON-EFFICIENT - - - - -
S1 4" RECESSED ADJUSTABLE
DOWNLIGHT, 40-DEG TILT,
5.4" DEPTH IC RATED,
TRIMLESS SQUARE BEVEL
WITH SHOWER RATING
LF
ILLUMINATION
HVS-1BA-S-
015MR16X-AD-TT-1-IC
9062-MW-SHCL WHITE (1) 7W 12V MR16, 450
LUMENS, VERIFY
CCT, EXPERTCOLOR
BY PHILIPS
HIGH-EFFICACY:
LED < 15W
61 LPW @ 7W
INTEGRAL 12V
MAGNETIC LOW
VOLTAGE
DIMMING
TRANSFORMER
MLV DIM RECESSED
FLANGELESS
GYP ≤ 1"
ENERGY EFFICIENCY
ENERGY COMPLIANCE:
ALL RECESSED LIGHTING IC-RATED
98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT | 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT SOURCES
2018-02-06
DESCRIPTION MANUFACTURER FINISH LAMP NOTESINSTALLATION
ARCHITECTURAL LIGHTING FIXTURE SCHEDULE
CATALOG NUMBER
POWER SUPPLY CONTROLFIXTURE TYPE IMAGE
MOUNTING
SMUGGER GROVE
3/1/18
• FIXTURE SCHEDULE MUST BE USED TOGETHER WITH LIGHTING FIXTURE CUTSHEETS FOR COMPLETE SPECIFICATION PACKAGE.
• DISCREPANCIES IN SPECIFICATIONS AND CUTSHEETS SHALL BE BROUGHT TO THE ATTENTION OF 186 FOR SPECIFICATION CONFIRMATION PRIOR TO ORDER.
• FIXTURE SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186.
• ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS; ALTERNATE LAMPS MUST BE APPROVED IN WRITING BY 186:
• LOW VOLTAGE HALOGEN FIXTURES TO BE LAMPED WITH LED MR16 LAMPS SPECIFIED BY 186 WHERE NECESSARY TO MEET ENERGY CODE.
• 186 WILL PROVIDE BEAMSPREAD PLAN DENOTING BEAMSPREAD OPTIC TYPE AND SPECIFIC LOCATIONS FOR ALL APPLICABLE LIGHTS.
E.C. VERIFICATION PRIOR TO ORDER
• E.C. TO VERIFY THE FOLLOWING PRIOR TO ORDER:
• VERIFY RECESSED HOUSING TYPES (IC, NON-IC, AIRTIGHT, REMODEL) ARE APPROPRIATE FOR EACH MOUNTING LOCATION.
• VERIFY INDICATED FINISHES; TO BE CONFIRMED WITH 186, ARCHITECT OR INTERIOR DESIGNER.
• VERIFY FINISHED CEILING THICKNESS COMPATIBILITY WITH RECESSED HOUSINGS AND TRIMS.
• VERIFY ALL TRANSFORMER SIZES.
• E.C. RESPONSIBLE FOR VERIFICATION OF ALL FIXTURE QUANTITIES AND LENGTHS PRIOR TO ORDER.
• E.C. TO REQUEST BEAMSPREAD PLAN FROM 186 PRIOR TO ORDER OF LAMPS IF NOT ALREADY PROVIDED.
GENERAL FIXTURE SCHEDULE NOTES:
TRANSFORMER AND DRIVER REQUIREMENTS
• E.C. TO VERIFY ALL TRANSFORMER SIZES PRIOR TO ORDER.
• MAGNETIC XFMRS SHALL BE TOROIDAL.
• ELECTRONIC XFMRS FOR MR16 HALOGEN/LED FIXTURES MUST BE "NO-LOAD" TO ACCOMMODATE EITHER TYPE OF LAMPING.
• LOW VOLTAGE HOMERUN WIRES MUST BE SIZED APPROPRIATELY:
• SIZE WIRE TO MINIMIZE VOLTAGE DROP TO FIXTURES.
• SIZE WIRE TO ACCOMMODATE HIGH-AMPERAGE APPLICATIONS SUCH AS 12V MONORAIL, CABLE AND LANDSCAPE LIGHTING.
• STRANDED WIRE IS RECOMMENDED IN THESE APPLICATIONS.
• ALL XFMRS & DRIVERS MUST BE MOUNTED IN AN ACCESSIBLE LOCATION REMOVED FROM THE ROOM'S AIRSPACE SUCH AS A CRAWL SPACE, OR MECHANICAL ROOM.
INSTALLATION OF FIXTURES
• ALL WHITE TRIM RINGS TO BE PAINTED TO MATCH CEILING.
• ELECTRICAL CONTRACTOR TO REMOVE ALL SHIPPING SCREWS FROM RECESSED FIXTURES PRIOR TO SHEETROCK.
• ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS.
• ELECTRICAL CONTRACTOR TO PROVIDE OVER VOLTAGE PROTECTION FOR ALL LED FIXTURES SUCH THAT THERE IS NOT POSSIBILITY TO EXCEED RATED VOLTAGE.
• IF LED TAPE LIGHT THAT HAS BEEN AFFIXED TO A SURFACE IS REMOVED, NEW TAPE LIGHT MUST BE USED IF THE TAPE HAS BEEN ELECTRICALLY COMPROMISED.
• ALL LED TAPE LIGHT SHALL BE MOUNTED TO A HEAT SINK APPROVED BY 186 (ALUMINUM CHANNEL, ALUMINUM HEAT SINK TAPE, ETC.) UNLESS SPECIFICALLY DIRECTED OTHERWISE.
3/1/18