HomeMy WebLinkAboutFile Documents.63 Smuggler Grove Rd.0049.2018 (2).ARBKHOUSING TRIM & ACCESSORIES MATERIAL IN. A1 4" RECESSED ADJUSTABLE DOWNLIGHT, 40-DEG TILT, 5.4" DEPTH IC RATED, TRIMLESS SQUARE BEVEL LF ILLUMINATION HVS-1BA-S- 015MR16X-AD-TT-1-IC 9062-MW WHITE (1) 7W 12V MR16, 450 LUMENS, (VERIFY CCT), EXPERTCOLOR BY PHILIPS HIGH-EFFICACY: LED < 15W 61 LPW @ 7W INTEGRAL 12V MAGNETIC LOW VOLTAGE DIMMING TRANSFORMER MLV DIM RECESSED FLANGELESS GYP ≤ 1" A2 4X8" RECESSED ADJUSTABLE DOWNLIGHT WITH 2 HEADS, 40-DEG TILT, 5.5" DEPTH IC RATED, TRIMLESS SQUARE BEVEL LF ILLUMINATION HVS-2BA-S- 015MR16X-AD-TT-1-IC 9604-MW WHITE (2) 7W 12V MR16, 450 LUMENS, (VERIFY CCT), EXPERTCOLOR BY PHILIPS HIGH-EFFICACY: LED < 15W 122 LPW @ 14W INTEGRAL 12V MAGNETIC LOW VOLTAGE DIMMING TRANSFORMER MLV DIM RECESSED FLANGELESS GYP ≤ 1" C (BY INTERIOR DESIGNER) CEILING MOUNT CLOSET FIXTURE BY INTERIOR DESIGNER - - - NON-EFFICIENT - - - - - L1 SURFACE MOUNTED LED STRIP IN LENSED ALUMINUM CHANNEL, 1/2" HEIGHT, 5/8" WIDTH PARADIGM LED PL-AMC-1612; PL-OLC-1612; PL-EC-1612; PL-ECL-1612 PL-FLEXSR590- (VERIFY CCT)-INT-24 ALUMINUM (HIDDEN) LED, 4.5W/FT 24V, 420 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 93 LPW @ 4.5W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SURFACE MOUNT - - L2 (WET) SURFACE MOUNTED LED STRIP IN LENSED ALUMINUM CHANNEL, 1/2" HEIGHT, 5/8" WIDTH; SILICONE ENDCAPS FOR WET RATING PARADIGM LED PL-AMC-1612; PL-OLC-1612; PL-EC-1612; PL-ECL-1612 SILICONE FOR WET RATING PL-FLEXSR590- (VERIFY CCT)-INT-24 ALUMINUM (HIDDEN) LED, 4.5W/FT 24V, 420 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 93 LPW @ 4.5W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SURFACE MOUNT - - *APPLY SILICONE PER MFR RECOMMENDATIONS FOR WET RATING *CONSULT MFR REGARDING PRE- MADE LENGTHS L3 (HIGH OUTPUT) SURFACE MOUNTED HIGH- OUTPUT LED STRIP IN LENSED CHANNEL, 1" WIDTH, 5/8" HEIGHT PARADIGM LED PL-AMC-2415; PL-OLC-2415; PL-EC-2415; PL-ECL-2415 PL-FLEXDR590- (VERIFY CCT)-INT-24 ALUMINUM (HIDDEN) LED, 9W/FT 24V, 850 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 94 LPW @ 9W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SURFACE MOUNT - - L4 SURFACE MOUNTED LED STRIP IN ANGLED, LENSED ALUMINUM CHANNEL, 5/8" PROFILE PARADIGM LED PL-AMC-1616; PL-OLC-1616; PL-EC-1616; PL-ECL-1616 PL-FLEXDR590- (VERIFY CCT)-INT-24 ALUMINUM (HIDDEN) LED, 4.5W/FT 24V, 420 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 93 LPW @ 4.5W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SURFACE MOUNT - - L5 (CLOSET) SURFACE MOUNTED LED STRIP IN LENSED ALUMINUM CHANNEL - CHANNEL SHAPE TBD PER CLOSET DETAIL; FACTORY ASSEMBLES TO LENGTH WITH CLOSET RATED STICKER PARADIGM LED PL-CL-(VERIFY CCT)- 24-DIM-(SHAPE)- (LENGTH) PL-CL-EC-(SHAPE) PL-CL-ECL-(SHAPE) ALUMINUM (HIDDEN) LED, 4.5W/FT 24V, 420 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 93 LPW @ 4.5W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SURFACE MOUNT - - L6 (STAIRS) SURFACE MOUNTED LED STRIP IN LENSED ALUMINUM CHANNEL, 1/2" HEIGHT, 5/8" WIDTH; BLACK FINISH - LIGER LENS PARADIGM LED + KLUS LED 17031 - LIGER LENS B1718_K(LENGTH) - BLACK EXTRUSION PDS4 PL-FLEXSR590- (VERIFY CCT)-INT-24 BLACK LED, 4.5W/FT 24V, 420 LM/FT, (VERFY CCT), +90 CRI HIGH-EFFICACY: LED < 15W 93 LPW @ 4.5W REMOTE 24V MAGNETIC LOW VOLTAGE DIMMING DRIVER MLV DIM SEE ARCH. STAIR DETAIL - - P (BY INTERIOR DESIGNER) SUSPENDED DECORATIVE PENDANT BY INTERIOR DESIGNER - - NON-EFFICIENT - - - - - S1 4" RECESSED ADJUSTABLE DOWNLIGHT, 40-DEG TILT, 5.4" DEPTH IC RATED, TRIMLESS SQUARE BEVEL WITH SHOWER RATING LF ILLUMINATION HVS-1BA-S- 015MR16X-AD-TT-1-IC 9062-MW-SHCL WHITE (1) 7W 12V MR16, 450 LUMENS, VERIFY CCT, EXPERTCOLOR BY PHILIPS HIGH-EFFICACY: LED < 15W 61 LPW @ 7W INTEGRAL 12V MAGNETIC LOW VOLTAGE DIMMING TRANSFORMER MLV DIM RECESSED FLANGELESS GYP ≤ 1" ENERGY EFFICIENCY ENERGY COMPLIANCE: ALL RECESSED LIGHTING IC-RATED 98.4% OF ALL FIXTURES AND LIGHT BULBS ARE EFFICIENT | 126 EFFICIENT FIXTURES, 2 NON-EFFICIENT SOURCES 2018-02-06 DESCRIPTION MANUFACTURER FINISH LAMP NOTESINSTALLATION ARCHITECTURAL LIGHTING FIXTURE SCHEDULE CATALOG NUMBER POWER SUPPLY CONTROLFIXTURE TYPE IMAGE MOUNTING SMUGGER GROVE 3/1/18 • FIXTURE SCHEDULE MUST BE USED TOGETHER WITH LIGHTING FIXTURE CUTSHEETS FOR COMPLETE SPECIFICATION PACKAGE. • DISCREPANCIES IN SPECIFICATIONS AND CUTSHEETS SHALL BE BROUGHT TO THE ATTENTION OF 186 FOR SPECIFICATION CONFIRMATION PRIOR TO ORDER. • FIXTURE SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186. • ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS; ALTERNATE LAMPS MUST BE APPROVED IN WRITING BY 186: • LOW VOLTAGE HALOGEN FIXTURES TO BE LAMPED WITH LED MR16 LAMPS SPECIFIED BY 186 WHERE NECESSARY TO MEET ENERGY CODE. • 186 WILL PROVIDE BEAMSPREAD PLAN DENOTING BEAMSPREAD OPTIC TYPE AND SPECIFIC LOCATIONS FOR ALL APPLICABLE LIGHTS. E.C. VERIFICATION PRIOR TO ORDER • E.C. TO VERIFY THE FOLLOWING PRIOR TO ORDER: • VERIFY RECESSED HOUSING TYPES (IC, NON-IC, AIRTIGHT, REMODEL) ARE APPROPRIATE FOR EACH MOUNTING LOCATION. • VERIFY INDICATED FINISHES; TO BE CONFIRMED WITH 186, ARCHITECT OR INTERIOR DESIGNER. • VERIFY FINISHED CEILING THICKNESS COMPATIBILITY WITH RECESSED HOUSINGS AND TRIMS. • VERIFY ALL TRANSFORMER SIZES. • E.C. RESPONSIBLE FOR VERIFICATION OF ALL FIXTURE QUANTITIES AND LENGTHS PRIOR TO ORDER. • E.C. TO REQUEST BEAMSPREAD PLAN FROM 186 PRIOR TO ORDER OF LAMPS IF NOT ALREADY PROVIDED. GENERAL FIXTURE SCHEDULE NOTES: TRANSFORMER AND DRIVER REQUIREMENTS • E.C. TO VERIFY ALL TRANSFORMER SIZES PRIOR TO ORDER. • MAGNETIC XFMRS SHALL BE TOROIDAL. • ELECTRONIC XFMRS FOR MR16 HALOGEN/LED FIXTURES MUST BE "NO-LOAD" TO ACCOMMODATE EITHER TYPE OF LAMPING. • LOW VOLTAGE HOMERUN WIRES MUST BE SIZED APPROPRIATELY: • SIZE WIRE TO MINIMIZE VOLTAGE DROP TO FIXTURES. • SIZE WIRE TO ACCOMMODATE HIGH-AMPERAGE APPLICATIONS SUCH AS 12V MONORAIL, CABLE AND LANDSCAPE LIGHTING. • STRANDED WIRE IS RECOMMENDED IN THESE APPLICATIONS. • ALL XFMRS & DRIVERS MUST BE MOUNTED IN AN ACCESSIBLE LOCATION REMOVED FROM THE ROOM'S AIRSPACE SUCH AS A CRAWL SPACE, OR MECHANICAL ROOM. INSTALLATION OF FIXTURES • ALL WHITE TRIM RINGS TO BE PAINTED TO MATCH CEILING. • ELECTRICAL CONTRACTOR TO REMOVE ALL SHIPPING SCREWS FROM RECESSED FIXTURES PRIOR TO SHEETROCK. • ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS. • ELECTRICAL CONTRACTOR TO PROVIDE OVER VOLTAGE PROTECTION FOR ALL LED FIXTURES SUCH THAT THERE IS NOT POSSIBILITY TO EXCEED RATED VOLTAGE. • IF LED TAPE LIGHT THAT HAS BEEN AFFIXED TO A SURFACE IS REMOVED, NEW TAPE LIGHT MUST BE USED IF THE TAPE HAS BEEN ELECTRICALLY COMPROMISED. • ALL LED TAPE LIGHT SHALL BE MOUNTED TO A HEAT SINK APPROVED BY 186 (ALUMINUM CHANNEL, ALUMINUM HEAT SINK TAPE, ETC.) UNLESS SPECIFICALLY DIRECTED OTHERWISE. 3/1/18