Loading...
HomeMy WebLinkAboutFile Documents.100 E Main St.0006.2019 (19).ACBKSilver Town Structures 307N AABC Aspen, CO 81611 Nov 16, 2018 RE: Dr Kadison Medical Office 100 Main St. Aspen, CO 81611 James Guest And Aspen Building Department: Thank you for choosing Brutsaert Engineering. I am writing this letter to confirm my involvement with this project as a structural engineer. I reviewed the proposed remodel onsite with yourself as a representative of Rutgers Construction on Nov 12, 2018. I also reviewed existing structural drawings by Brutsaert Engineering dated 5/27/16. The structure is two story steel and masonry construction. The roof is primarily a wood structure as are the upper level partition walls. The main floor is slab on grade with a partial basement. The upper floor is a mix of steel beams with wood joists. There are C.M.U partition walls throughout the lower level. The proposed floor plan includes removal and replacement of several partition walls at the main level office suite. The new partition walls will be constructed of wood. Based on my observations of the existing structure, the proposed changes do not interfere with or alter the existing gravity load path. The partition walls are part of the lateral load resisting system and can not be removed entirely. The proposal to replace them with wood framing is feasible in most case. Walls must be constructed with a double top plate that is attached to the upper floor framing with a minimum of (3) – 10d nails per foot. Sheathing shall be attached with 8d nails @ 6” along panel edges and at 12” O.C. in the field. Replaced partition walls that run perpendicular to the exterior brick walls must be constructed per the attached detail. I have identified a column along Grid 5 that bears on an existing C.M.U. wall. This wall is identified in the plans I reviewed as one that will be replaced. James guest of Rutgers Construction has assured me by telephone that this wall will not be removed without further engineering consultation. The structural integrity of this building will not be affected by the proposed changes. Any framing conditions uncovered during demolition that do not conform with the reviewed drawings shall be brought to the attention of the engineer. I have agreed to make myself available for consult when new information regarding the structure allows for a better assessment. Any structural modifications necessary will be provided at that time. Sincerely, Hein Brutsaert P.E. 11-16-18 1 TREATED WOOD PLATE w/ 1/4" Titen HD SCREWS @ 24" O.C.EXISTING EXTERIOR BRICK WALL Dr Kadison 2x FRAMING @ 16" O.C. w/ 1/2" TYPE X GYPSUM SHEATHING ON BOTH SIDES. TREATED PLATE w/ 1/2" EPOXY OR WEDGE ANCHORS @ 32" O.C. (3" EMBEDMENT) EXISTING SLAB AND FOUNDATION WALL