HomeMy WebLinkAboutFile Documents.100 N 8th St.0243.2017 (4).ARBKResidential Design Standards
Exemption Form
Exemption Applies Notes
Remodel of a structure where the alterations proposed
change the exterior of the building, but are not addressed
by any of the Residential Design Standards
Residential unit within a mixed-use building
Designated historic resource listed on the Aspen
Inventory of Historic Landmark Sites and Structures
Has already received a board design approval
Disclaimer: This exemption is only valid for the attached scope of work. If the project scope ex-
pands to include work subject to Residential Design Standards, the applicant shall be required
to apply for an Administrative Compliance Review.
Address:
Parcel ID:
Zone District/PD:
Representative:
Email:
Phone:
Scope of Work:
Reviewed by:
(Project plans/elevations attached)
7'-0"15'-3"EXISTING DECK 121
SQ. FT.
NEW SLIDING DOOR TO
REPLACE WINDOWS
4'-2"11'-6"ADJACENT UNITADJACENT DECKLOCATION OF
BIKE RACKS
EXISTING PINE TREES
TO REMAIN
EXISTING ASPEN TREE
TO REMAIN
DN
NEW SLIDING DOOR TO
REPLACE WINDOWS
6"
PROPOSED DECK
167 SQ. FT.
INSULATE EXISTING DOOR
CAVITY TO MEET R-21
INSULATION REQUIREMENTS
4'-2"11'-6"ADJACENT UNITADJACENT DECKLOCATION OF
BIKE RACKS
EXISTING PINE TREES
NEW SHRUBS AND
PINE TREES7'-8"20'-0 1/4"
EXISTING TREE TO
REMAIN6"3'-6"PROJECT
SCALE
EXIST/PROPOSED
MAIN LEVEL
FLOOR PLAN
1/4" = 1'-0"
16032.00
A-101
NEXISTING
MAIN LEVEL FLOOR PLAN
1/4" = 1'-0"
1
A-102
0 2 4 8
Scale: 1/4" = 1'-0"
PROPOSED
MAIN LEVEL FLOOR PLAN
1/4" = 1'-0"
2
A-102
COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID #273512313010VILLAS OF ASPEN-UNIT 21C THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
4/11/2017 HOA DESIGN PACKAGE
ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR
WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH.
OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH.
PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP.
PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER
AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE
DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE.
FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL
HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES,
PORTLANT CEMENT OR EQ.
1.
2.
3.
4.
5.
FLOOR PLAN
GENERAL NOTES
PROJECT
SCALE
EXISTING/
PROPOSED
VIEWS
17002.00
A-201
COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID #273512313010VILLAS OF ASPEN-UNIT 21C THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS
300 S. SPRING ST. SUITE 201
ASPEN, CO 81611
(970) 710-2938
DATE
4/11/2017 HOA DESIGN PACKAGE
PROPOSED
VIEW FROM NORTH4
A-201
PROPOSED
VIEW FROM WEST5
A-201
PROPOSED
SITE PLAN6
A-201
EXISTING
VIEW FROM NORTH1
A-201
EXISTING
VIEW FROM WEST2
A-201
EXISTING
SITE PLAN3
A-201