Loading...
HomeMy WebLinkAboutFile Documents.100 N 8th St.0243.2017 (4).ARBKResidential Design Standards Exemption Form Exemption Applies Notes Remodel of a structure where the alterations proposed change the exterior of the building, but are not addressed by any of the Residential Design Standards Residential unit within a mixed-use building Designated historic resource listed on the Aspen Inventory of Historic Landmark Sites and Structures Has already received a board design approval Disclaimer: This exemption is only valid for the attached scope of work. If the project scope ex- pands to include work subject to Residential Design Standards, the applicant shall be required to apply for an Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Scope of Work: Reviewed by: (Project plans/elevations attached) 7'-0"15'-3"EXISTING DECK 121 SQ. FT. NEW SLIDING DOOR TO REPLACE WINDOWS 4'-2"11'-6"ADJACENT UNITADJACENT DECKLOCATION OF BIKE RACKS EXISTING PINE TREES TO REMAIN EXISTING ASPEN TREE TO REMAIN DN NEW SLIDING DOOR TO REPLACE WINDOWS 6" PROPOSED DECK 167 SQ. FT. INSULATE EXISTING DOOR CAVITY TO MEET R-21 INSULATION REQUIREMENTS 4'-2"11'-6"ADJACENT UNITADJACENT DECKLOCATION OF BIKE RACKS EXISTING PINE TREES NEW SHRUBS AND PINE TREES7'-8"20'-0 1/4" EXISTING TREE TO REMAIN6"3'-6"PROJECT SCALE EXIST/PROPOSED MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 16032.00 A-101 NEXISTING MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 1 A-102 0 2 4 8 Scale: 1/4" = 1'-0" PROPOSED MAIN LEVEL FLOOR PLAN 1/4" = 1'-0" 2 A-102 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID #273512313010VILLAS OF ASPEN-UNIT 21C THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 4/11/2017 HOA DESIGN PACKAGE ALL WALLS WITH SHEAR PLYWOOD SHALL HAVE A CONTINUOUS FLUSH FINISH. FURR WALLS OR CONTINUE PLYWOOD TO MAINTAIN THE REQUIRED FLUSH FINISH. OFFSET STUDS WHERE REQUIRED SO THAT FINISH WALL SURFACES WILL BE FLUSH. PROVIDE BLOCKING FOR ALL ARTWORK, TOWEL BARS AND TISSUE HOLDERS, TYP. PROVIDE WATER RESISTANT GYPSUM BOARD BEHIND ALL PLUMBING FIXTURES, UNDER AND AROUND TUB AND SHOWER ENCLOSURES TO A HEIGHT OF 70" MIN. ABOVE THE DRAIN INLET. , OR APPROVED BACKER BOARD UNDER TILE. FINISH MATERIALS FOR ALL BATHS, SHOWERS, WALLS AT SHOWER ENCLOSURES SHALL HAVE A SMOOTH, HARD, NON-ABSORBANT SURFACE SUCH AS TILES/CERAMIC TILES, PORTLANT CEMENT OR EQ. 1. 2. 3. 4. 5. FLOOR PLAN GENERAL NOTES PROJECT SCALE EXISTING/ PROPOSED VIEWS 17002.00 A-201 COPYRIGHT 2015 THUNDERBOWL ARCHITECTS ASPEN, COLORADOPARCEL ID #273512313010VILLAS OF ASPEN-UNIT 21C THUNDERBOWLARCHITECTSTHUNDERBOWL ARCHITECTS 300 S. SPRING ST. SUITE 201 ASPEN, CO 81611 (970) 710-2938 DATE 4/11/2017 HOA DESIGN PACKAGE PROPOSED VIEW FROM NORTH4 A-201 PROPOSED VIEW FROM WEST5 A-201 PROPOSED SITE PLAN6 A-201 EXISTING VIEW FROM NORTH1 A-201 EXISTING VIEW FROM WEST2 A-201 EXISTING SITE PLAN3 A-201