Loading...
HomeMy WebLinkAboutFile Documents.108 Maple Ln.0035.2017 (8).ARBK11FOR THE MOST COMPLETE AND CURRENT INFORMATION VISIT RENEWAIRE.COM EV-SERIES & GRSpecifications may be subject to change without notice. INDOOR UNIT EV 300 SPECIFICATIONS Ventilation Type: Static plate, heat and humidity transfer Typical Airflow Range: 150-300 CFM Standard Features: Painted cabinet Line-cord power supply Low-voltage circuit for controls Unit may be mounted in any orientation Controls: On board 24 VAC transformer/relay package with switched dry contacts Filters: Total qty. 2, MERV 8, spun-polyester media: 10 1/2" x 21 3/4" x 1" Unit Dimensions & Weight: 33 3/4" L x 24" W x 20" H 72 lbs. Max. Shipping Dimensions & Weight (on pallet): 34" L x 44" W x 34" H 115 lbs. Motor(s): Qty. 1, Double-shaft standard motor Accessories: Backdraft damper 8" Wall cap 8" - taupe plastic, galvanized, paintable galvanneal Louver with 8" round duct connection - 12" (W) x 8" (H) Percentage timer control (PTL) Push-button point-of-use controls (PBL), PTL req'd. Percentage timer control with furnace interlock (FM) Electric duct heater - EK series (1–60 kW) ELECTRICAL DATA HP Volts HZ Phase Input Watts FLA 0.2 120 60 Single 315 @ 297 CFM 3.3 UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H20 Temp EFF%Total EFF% Winter/Summer* 170 1.0 78 73/59 191 0.9 77 71/57 215 0.8 75 69/55 256 0.7 73 66/51 277 0.6 71 65/49 295 0.5 70 63/47 311 0.4 69 62/46 5 1/2" 9 1/8" 5 3/8" 9 1/4" OA EA RA FA 34" Line Cord 9 3/4"Typ. 28 3/4" Case 33 5/8" Overall 2 1/2" Typ. 24" Overall(with HangingBracket)10"Typ.18 5/8"Case 5/8" Typ. 2 3/8" 21 3/4" Overall(with Hanging Bracket)To Fit 8" Duct Typ.20"Overall 23 7/8" Case 22 1/4" MinimumService Area (Door can beRemoved from Hinges.)18 1/2"MinimumService AreaDoor Swing 24V AC Control Terminal LEFT VIEW FRONT VIEW RIGHT VIEW TOP VIEW Model: EV300Drawing Type: Unit DimensionVersion: MAR16 ABBREVIATIONSEA: Exhaust Air to outsideOA: Outside Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside INSTALLATION ORIENTATIONUnit may be installed in any orientation. NOTE1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE ROUNDED TO THENEAREST EIGHTH OF AN INCH. 2.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. UNIT DIMENSIONS EV-SERIES & GRAIRFLOW CONFIGURATION Available as shown in dimension drawing. UNIT MOUNTING & APPLICATION Can be mounted in any orientation. RA/EA airstream can be switched with OA/FA airstream. STANDARD * See HVI certification ratings on page 135 of RenewAire’s Full Line Volume XVI Catalog.