Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.100 E Main St.0040.2016 (8).ACBK
Brian A. Clark, R.A. Ballina Design Group, LLC Architectural & Engineering Services 1610 Adams Avenue Dunmore, Pa 18509 ph. 570.207.0195 fax. 570.207.0198 info@ballinagroup.com Bonnie Muhigirwa 5-December-2016 Plans Examiner City of Aspen Community Development RE: 100 East Main Street Building Plan Review Response Items Dear Bonnie, Enclosed in this letter, please find our official responses to items as detailed on your Building Plan Review Markup Summary send to Ballina on November 25th, 2016. Item One: Provide Cut Sheets for light fixtures that includes maximum wattage Response: Cut Sheets Attached. Item Two: One-hour rated fire resistant floor ceiling to be provided/maintained. Provide detail for assembly and indicate whether lighting, ventilation, etc. is to be part of a drop ceiling or how these penetrations are to be protected. Response: One hour rated floor/ceiling shall be provided per UL #263 as noted on Drawing A-2, Reflected Ceiling Plan throughout entire space. Drop Ceilings shall be located below rated ceiling. All light fixtures recessed in Gypsum Board shall be rated per lighting fixture schedule. All additional lighting shall be located in drop ceiling beneath rated gypsum board ceiling. All exhaust fan and ductwork shall be installed below existing gypsum board ceiling to maintain rating per Keyed Note 4 on drawing M-2. Item Three: Toilet Room 117, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door size reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Brian A. Clark, R.A. Ballina Design Group, LLC Architectural & Engineering Services 1610 Adams Avenue Dunmore, Pa 18509 ph. 570.207.0195 fax. 570.207.0198 info@ballinagroup.com Item Four: Surgery Rooms 111 & 116, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door sizes reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Item Five: Lab119, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door sizes reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Item Six: Accessible sale/service counter to be provided. Response: Accessible sale/service counter provided. Please see clarifications on A-1 and A-3. Item Seven: Each individually enclosed area is required to have at least one manual control for the lighting serving that area. Each area with a manual control shall allow the occupant to reduce the lighting load by at least 50%. Provide additional plan notes to illustrate how you comply with these two provisions. Response: This requirement does not apply given exceptions per COM Check, please see updated COM Check attached. 0 I L_ I n A-3 Y FLOOR PLAN SCALE: 11/a"= I'-0" BC D E F 0 OF CO Brian A. Clark 404258 ll' -9 t � 9'-5"• 8'-6" 8'-6" 8'-6" 8'-6" 7'= Il'_m"• 4'-35q"t /� f ✓ 620-16 FT NOTE: ALL DRAWINGS CONTAINED IN THIS PACKAGE ARE BASED ON THE EQUIPMENT AND EQUIPMENT DETAILS CONTAINED ON THE CENTER POINT DESIGN / BENCO DENTAL DRAWINGS INCLUDED AT THE END OF THIS PACKAGE. IF EQUIPMENT OTHER THAN WHAT IS SPECIFIED ON THESE DRAWINGS IS PURCHASED, THE INSTALLATION, UTILITY CONNECTIONS AND SPACE REQUIREMENTS MAY BE DIFFERENT AND IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND HIS/HER CONTRACTORS TO MAKE THE NECESSARY MODIFICATIONS IN THE FIELD TO ACCOMMODATE THIS EQUIPMENT. S. TMENT ROOM n2NT ROOM ROOM #I 10 109 108 101 106 ❑ r CI 104 m O O O O ffl � 104 0 0 0 0 4 ' I y a 0_ � 0 0I os 3 : 3 N� EQUAL 5'-0" EQUAL A-3 EXISTING COLUMNS TO LH REMAIN- COORDINATE FINAL 3 DIMENSIONS IN FIELD - ADJUST THICKNESS OF WALL TO CONCEAL COLUMNS lyn-3 2 Urt-3 O IS O IS O 15 O 15 15 m m 00 m i la A-3 2 2,_5„ 2'-O„ 2_g14�, 2' S�, 112'-0" 2' S,. 2,_l}„: I'-5}' 2_g„ / -NOTE: - TOP OF LOW WALL TO MATCH 6,1-34 aO S SILL HEIGHT OF EXTERIOR EXISTING MECH NICAL WINDOWS 2 CHASE TO REMAIN 105 11 �� Wr-I Il p_$R” I1 2 16 Wr- WT -3 MQ O O 9 14 Ill IB II9 1 I]0 I I IDI S 0 n i s CHECK-IN 1\ Aa 121 A-3 ILIZATI lyr- 120 �� - 102 -SEE NOTE, FOR ENLARGED 1 �� 1 \\ RECEPTION DESK PLAN 1 E -`moi/ 13 • 3 6 p NOTE: SOLID WALLS DEPICT EXISTING FIRE RA ED EXISTING TENANT DEMISING WALL/CHASE TO REMAIN- TENANT SPACE TOILET R.M. GENERAL CONTRACTOR RESPONSIBLE FOR NOT IN SCOPE COORDINATING THE INSTALLATION OF 51/5" FIRE RATED GYPSUM BOARD ON TENANT SID OF EXISTING WALL TO COMPLETE I HR RATED ASSEMBLY LOBBY WITH DEVELOPER UNDER SEPARATE CONTRACT.NOT IN SCOPE o _ _ _ n . 4 NOTE: ALL ARCHITECTURAL DRAWINGS SHALL BE CONSIDERED AN EXTEN51ON OF, AND USED IN COORDINATION AND CONJUNCTION WITH, ALL BENCO / CENTER POINT DESIGN DRAWINGS CONTAINED IN THIS DRAWING PACKAGE (0-6ERIES DRAWINGS) NOTE: GENERAL CONSTRUCTION NOTES: ALL EXISTING EXTERIOR WALLS 70 HAVE ALL FINISH MATERIAL REMOVED 45 PART OF DEMOLITION. GENERAL CONTRACTOR TO PROVIDE AND INSTALL 111/2" FURRING S RIPS AND Na" GYPSUM BOARD ON ALL EXTERIOR WALLS UNLESS OTHERWISE NOTED - TYPICAL ALL EXTERIOR WALLS OF TENANT SPACE- GYPSUM BOARD PROVIDED AND INSTALLED UNDER SEPARATE CONTRACT WI7H DEVELOPER. INSULATION FULL HEIGHT- SEE WALL TYPE. PARTITION LEGEND GENERAL CONSTRUCTION NOTES: Ip GENERAL PARTITION NOTES: I. WHILE FRAMING PARTITIONS AND HANGING DRYWALL, COORDINATE WITH BENGO/CENTER POINT DETAIL 08/02.2 AND GENERALLY LOCATED PER FLOOR I. TOILET ROOMS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS MECHANICAL CONTRACTOR FOR DUCT LAYOUT, DUCT PENETRATIONS AND RANSFER FULL HEIGHT. GRILL LOCATIONS THRU WALLS ABOVE CEILINGS. OPENINGS SHALL BEPROVIDED PROVIDE FRAMING AND GYPSUM BOARD TO COMPLETE GYPSUM BOARD 2. INFILL STUD CAVITIES SURROUNDING TOILET ROOM WITH 311/2" OR 511/2" SOUND BATT IN WALLS ABOVE CEILINGS TO FACILITATE RETURN AIR MOVEMENT BACK To UNITS- INSULATION FULL HEIGHT- SEE WALL TYPE. COORDINATE WITH MECHANICAL DRAWINGS AND CONTRACTOR. THESE OPENINGS BACKING PER BENCO/CENTER POINT DETAIL 12/02.2 AND LOCATED PER FLOOR Is SHALL BE FRAMED WITH GYPSUM BOARD OR OTHER NON-COMBUSTIBLE M TERIAL 3. ALL WOOD SILL PLATES IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE TO COVER WOOD STUDS. BOARD, GENERAL CONTRACTOR RESPONSIBLE FOR PROVIDING LEVEL TREATED. PROVIDE BLOCKING IN WALL FOR WALL X-RAY/PAN CONTROL NAILER PER SURFACES TO MEET EXISTING WALL THICKNESS. 2. ALL INSULATION AND FACING TO MEET IBC REQUIREMENTS FOR FLAME SPREAD BENCO/CENTER POINT DETAIL 01/022 AND LOCATED PER FLOOR PLAN Q21 4. WHERE WALLS RUN GREATER THAN 10' AFF., PROVIDE 2X4 OR 2X6 HORIZONTAL INDEX (NOT MORE THAN 25) AND SMOKE -DEVELOPED INDEX (NOT MORE THAN 450), WOOD STUDS ON THE FLAT FOR FIRE BLOCKING AT MIDPOINT 3, IN EXISTING BUILDING (FIRST AND SECOND FLOOR) GENERAL CONTRACTOR EXISTING INTERIOR WALL TO HAVE ALL FINISH MATERIAL REMOVED DOWN TO wr-I 43." THICK NON -RATED / SOUND RATED PARTITION RESPONSIBLE OR REPAIRING/PATCHING AND SKIM COATING EXISTING WAL S TO ONE LAYER OF 51/•" GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AT 16" O.C. REMAIN AND PREPARING SURFACES FOR NEW WALL FINISHES. COORDINATE LOCATIONS AND LENGTHS WITH ENLARGED PLAN AND DETAILS. RUN STUDS AND GYPSUM BOARD FROM FINISH FLOOR TO BOTTOM OF ROOF FRAMING. CONTRACTOR TO PROVIDE AND INSTALL METAL FURRING STRIPS AND 51/5" INFILL STUD CAVITY WITH 311/2" SOUND BATT INSULATION FULL HEIGHT. INFILL ALL INSULATION NOTES: GYPSUM BOARD ON ALL INTERIOR SURFACES OF WALL. PROVIDE SOUND BATT GAPS IN GYPSUM BOARD WITH SOUND SEALANT. PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED EXIT SIGN. REFER TO 2/A-4 INSULATION IN TOILET ROOM 117. I. VERIFY ALL EXTERIOR CAVITY WALLS TO RECEIVE 5'1/2" THK. BATT INSULATION (MIN. 0 431/," THICK NON -RATED / NON -SOUND RATED PARTITION R-19) FULL HEIGHT OF WALLS. VERIFY EXISTING INSTALLATION UNDER SEPA ATE ONE LAYER OF 5/5" GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AT 16" O.C. PERMIT AND CONTRACT- COORDINATE WITH BUILDING DEVELOPER BENCO/CENTER POINT DETAIL 09/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1. RUN STUDS FROM FINISH FLOOR TO BOTTOM OF ROOF FRAMING. GYPSUM BOARD TO 2. ALL SOUND ATTENUATION BATT INSULATION TO BE UNFACED 311/2" THICK UNLESS re RUN FROM FINISHED FLOOR TO BOTTOM OF ROOF FRAMING. OTHERWISE NOTED. 'K'- wr-3 43/4" THICK NON -RATED / NON -SOUND RATED LOW WALL PER BENCO/CENTER POINT DETAIL 1O/Q22 AND LOCATED PER FLOOR BACKINPLAN u ONE LAYER OF 11/2" GYPSUM BOARD ON EACH SIDE OF 351/5" METAL STUDS (22 GA.) AT CONSTRUCTION KEY NOTES: QG 16" O.C. RUN STUDS AND GYPSUM BOARD FROM FINISHED FLOOR TO 42" A.FF. UNLESS CABINET. OTHERWISE NOTED. BOTTOM PLATE TO BE FLEX TRACK TO ACHIEVE DEISRED 0 PROVIDE UP TO FOUR (4) ROWS OF 2X6 WOOD BLOCKING BETWEEN 5TU 5 FOR RADIUS. (SEE DETAILS A/3). COORDINATE FINAL HEIGHTS WITH ALL ARCHITECTURAL MILLWORK- BASE AND/OR OVERHEAD CABINETS- (EITHER BY GC, BENG OR DETAILS AND INTERIOR ELEVATIONS. OTHERS) COORDINATE EXACT HEIGHTS AND LENGTHS OF BLOCKING WIT MILLWORK DRAWINGS (GENERALLY BLOCKING TO BE CENTERED AT 5", 36", 56" AND 54" A,FF1 <E�43q" ONE HOUR RATED (UL' U305) / SOUND RATED PARTITION SEE BENCO/CENTER POINT DETAILS 01, 02, 03 1 04 /02.2 FOR GENERAL DETAIL ONE LAYER OF 5/e" FIRE RATED GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AND COORDINATE LOCATION PER PLAN Q21, AT 16" O.0 (WITH TOP AND BOTTOM WOOD PLATE). RUN STUDS AND GYPSUM BOARD 0 PROVIDE BLOCKING WALL FOR WALL MOUNTED PAN/CEPH. UNIT PER FROM FINISHED FLOOR TO UNDERSIDE OF FRAMING ABOVE. FIRE CAULK TOP AND BENCO/CENTER POINT DETAIL 05/02.2 AND LOCATED PER FLOOR PLAN 02.1 BOTTOM OF GYPSUM BOARD WITH NELSON FIRE STOP CAULK SILICONE SEALANT. ALL EXTEND MORE THAN 4" OFF FACE OF WALL). PENETRATIONS THROUGH THIS WALL MUST BE FIRE STOPPED. INFILL ALL STUD 3 0 PROVIDE BLOCKING WALL FOR WALL MOUNTED X-RAY UNIT PER BENCO CENTER CAVITIES WITH 311/2" SOUND BATT INSULATION FULL HEIGHT. POINT DETAIL 06/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1 O PROVIDE BLOCKING WALL FOR WALL MOUNTED TV/MONITOR. COORDINAE T FINAL LOCATION IN FIELD WITH OWNER PRIOR TO INSTALLATION. AT MASONRY IALL Q LOCATIONS, PROVIDE PROPER ANCHORING- SEE MANUFACTURES INSTAL ATION FOR TYPES AND LOCATIONS. SPECIFICATIONS, EXISTING TOILET RM. NOT IN SCOPE O PROVIDE BLOCKING IN CEILING FOR CEILING MOUNTED LIGHT PER Ip PROvIDE BLOCKING IN WALL FOR HANDICAPPED ACCESSIBLE TOILET ROOM BENGO/CENTER POINT DETAIL 08/02.2 AND GENERALLY LOCATED PER FLOOR SINK/VANITY TO P INSTALLATION. COORDINATE BLOCKING WITH DETAIL 12/A-3, PLAN Q2.1. 15 PROVIDE FRAMING AND GYPSUM BOARD TO COMPLETE GYPSUM BOARD O PROVIDE BLOCKING FOR CEILING MOUNTED COMPUTER / MONITOR SUPPORT OPENING- MATCH WALL THICKNESS AND PROVIDE SMOOTH, LEVEL SURFACES. �Cwtt% BACKING PER BENCO/CENTER POINT DETAIL 12/02.2 AND LOCATED PER FLOOR Is PREP SURFACE OF NEW WALL OPENING WITH MIN. 11/2" FURRING AND 11/2" GYPSUM O PLAN 02.1. BOARD, GENERAL CONTRACTOR RESPONSIBLE FOR PROVIDING LEVEL O PROVIDE BLOCKING IN WALL FOR WALL X-RAY/PAN CONTROL NAILER PER SURFACES TO MEET EXISTING WALL THICKNESS. BENCO/CENTER POINT DETAIL 01/022 AND LOCATED PER FLOOR PLAN Q21 n EXISTING INTERIOR WALL TO HAVE ALL FINISH MATERIAL REMOVED DOWN TO O PROVIDE BLOCKING IN WALL FOR COUNTERTOP SUPPORT ATTACHMENT. STRUCTURAL /FRAMING COMPONENTS UNDER DEMOLITION PHASE. GENERAL ZOLIL COORDINATE LOCATIONS AND LENGTHS WITH ENLARGED PLAN AND DETAILS. X CONTRACTOR TO PROVIDE AND INSTALL METAL FURRING STRIPS AND 51/5" I� GYPSUM BOARD ON ALL INTERIOR SURFACES OF WALL. PROVIDE SOUND BATT O PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED EXIT SIGN. REFER TO 2/A-4 INSULATION IN TOILET ROOM 117. Q FOR DETAILS. l5 PROVIDE BLOCKING IN WALL FOR WALL MED-GAS/CYLINDER BACKING PER Im PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED TOILET ROOM SIGN. REFER cn BENCO/CENTER POINT DETAIL 09/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1. O TO 2/A-4 FOR DETAILS. re PROVIDE BLOCKING IN WALL FOR WALL ANALGESIA/VAC/NITROGEN OUTLET 'K'- PER BENCO/CENTER POINT DETAIL 1O/Q22 AND LOCATED PER FLOOR BACKINPLAN u PROVIDE CLASS RATED 101b. FIRE EXTINGUISHER- TO BE LOCATED IN BASE QG :3 CABINET. 12 PROVIDE FIRE EXTINGUISHER AND CABINET. CABINET TO BE LARSEN, CAMEO U SERIES MODEL • C -2409-R, STEEL TRIM AND DOOR, RECESSED, 5/16" TRIM LnULu, PROJECTION, CLEAR BUBBLE WITH BLACK LETTERS. EXTINGUISHER TO BE ABC lL MPIO WITH APPROPRIATE BRACKET FOR UNIT AND CABINET. TO COMPLY WITH ADA INSTALLATION GUIDELINES, INSTALL SO TOP OF EXTINGUISHER HANDLE AT Z 48" MAXIMUM ABOVE FINISH FLOOR CABINET (INCLUDING BUBBLE) CANNOT oW EXTEND MORE THAN 4" OFF FACE OF WALL). 3 NO, 13 PROVIDE BLOCKING IN WALL TO MOUNT ADA GRAB BARS (MEETING ICC/ANSI AII11 SECTION 609.5 FOR STRUCTURAL STRENGTH- 250 Ibs VERT. < HORIZ. FORCE) REQUIREMENTS AND OTHER TOILET ROOM ACCESSORIES. COORDINATE WITH 1/A-1 Q FOR TYPES AND LOCATIONS. C_4 001 U cp LLI ryJ, �N 00 lL 1W� �Cwtt% O N O V N V O Z ZOLIL O X I� w n� v/ Q � Q cn O W w �4 > :3 5� <r U LnULu, Q lL Z oW 3 NO, 0 Q U cp LLI Ii 1� lL 01 �Cwtt% N O V N V W Z ZOLIL O X w n� v/ Q � Q W w �4 > :3 <r U LnULu, Q lL Z Q 3 NO, 1 15" W DRAWER/FILE – BASE CABINET- TYP 11/2" THK. TRANSACTION ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND COUNTER TOP SURFACE EQUAL EQUAL EQUAL 3 ® 3'-8" APF.: TRANSACTION SHELF: 1'/2" THK COUNTER 21/2"9 GROMMETS IN a -x CONTINUOUS LEDGER BOARD FOR COUNTER WORK SURFACE TOP SUPPORT PMD Pm COUNTER- TYP. RECEPTION 11/2" THK., 25" D. 15" WIDE DRAWER BASE DESK TRANSACTION COUNTER ° THK. SLOPING BRACKET TOP SURFACE ® 2'-6" AFF.: \ o 0/2" THK SLOPING SUPPORT \� 15" W. BASE CABINET: PANEL AS NECESSARY FOR 4" H. BASE PmD Pm COUNTER TOP SUPPORT / d 3 W DCA LE LOW WALL BASE CABINET-INET-TYP. z E ° RADIUS: 5'-4" a 21i2"4 GROMMETS IN A-3 A-3 WORK SURFACE POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 COUNTER- TYP. `" 1112" THK. TRANSACTION _ \ R=13" COUNTER TOP SURFACE % ® 3'-8" APF.: x / o Q I''2" THK., 25" D. A -x \ TRANSACTION COUNTER TOP – 4' H. BASE SURFACE ® 2'-6" AFF.: 0 0l ENLARGED PLAN AT REI A–� SCALE: ._0.. NOTE: I MAINTAIN II'2" OVERHANG AT ALL COUNTER TOP SURFACES 3 u MAINTAIN 1✓2" OVERHANG AT Ott YINIOM VKRWIN= YVK ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND ELEVATION EQUAL EQUAL EQUAL Iii," THK, x 12" D. 1 0 TRANSACTION SHELF: 1'/2" THK COUNTER AT —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT PMD Pm THK. x 25" D. WORK RECEPTION 3 RECEPTION 15" WIDE DRAWER BASE DESK WITH LOCKING DRAWERS Ye -3 SCALE: THK. SLOPING BRACKET EPTH FOR COUNTER TOP �2" BAND SUPPORT AS NEEDED N 15" W. BASE CABINET: 1 N 4" H. BASE PmD Pm —WOOD VENEER d 3 SPACED m I6" OC � N – I'�2" THK, 25" D e POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 = `" 4" H. BASE ^ –� SCALE: BV' I'-0" 1 Q W NOTE: I MAINTAIN II'2" OVERHANG AT ALL COUNTER TOP SURFACES 3 u MAINTAIN 1✓2" OVERHANG AT Ott YINIOM VKRWIN= YVK ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND ELEVATION EQUAL EQUAL EQUAL Iii," THK, x 12" D. WOOD VENEER TRANSACTION SHELF: 1'/2" THK COUNTER AT —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT w WOOD VENEER Q THK. x 25" D. WORK RECEPTION 3 RECEPTION 15" WIDE DRAWER BASE DESK WITH LOCKING DRAWERS Ye -3 SCALE: THK. SLOPING BRACKET PAINTED GYPSUM BOARD ELEVATION AT s RECEPTION DESK A–� SCALE: 3/e"=1' -O" SOFFIT- SEE CEILING PLAN 2" ACCENT BAND FOR RADIUS EQUAL EQUAL EQUAL Iii," THK, x 12" D. WOOD VENEER TRANSACTION SHELF: 1'/2" THK COUNTER 4"H. BACKSPLASH: —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT w WOOD VENEER Q THK. x 25" D. WORK SURFACE: 3 RECEPTION 15" WIDE DRAWER BASE - WITH LOCKING DRAWERS ACCENT THK. SLOPING BRACKET EPTH FOR COUNTER TOP �2" BAND SUPPORT AS NEEDED N 15" W. BASE CABINET: 1 N 4" H. BASE ELEVATION AT s RECEPTION DESK A–� SCALE: 3/e"=1' -O" ADJ. SHELVES TYPICAL) P SCRIBE 6 WALL (TYPICAL) 4" WIRE PULLS- TYP. 2" H. VALANCE 4"H. BACKSPLASH 111/2" THK, 25" D. COUNTERTOP SURFACE CONT. 2X4 LEDGER BOARD WITH PLAM FINISH FOR COUNTERTOP SUPPORT LOCKABLE (3) DRAWER BASE CABINETS- TYP. 4" H. BASE ELEVATION AT PRIVATE 8 OFFICE '4 -3 SCALE: %"=1'-0" RUN COUNTERTOP BEHIND WALL INTO PERPENDICULAR WALL BEYOND - WRAP BACKSPLASH- SEE PLAN 4"H. BACKSPLASH 25" D. COUNTERTOP f]_'LA8NA'ETAINLES8 STEEL 0 PULL AS MRYD BY IKEA : ("601381.59)- TYP. `4 ADJ. SHELF MINI -FRIDGE WITH GLA55 DOOR I -22 ° 1'-11'= 4" H. BASE 3' NOTES: -64"t I. PRIOR TO FABRICATION, VERIFY EXISTING COLUMN LOCATION IN FIELD. MILLWORK SIZES AND DIMENSION TO BE DICTATED BY FINAL LOCATION. 2. PRIOR TO FABRICATION, VERIFY REFRIGERATOR SIZE TO BE SUPPLIED BY OWNER AS THIS MAY AFFECT OVERALL HEIGHT AND CABINET WIDTH. 3. UNDER COUNTER REFRIGERATOR MUST MEET ADA REQUIREMENTS / SPECIFICATIONS. ELEVATION AT '3 BEVERAGE STATION SCALE: 3b" - 1 -ID" A-3 AM I''2" THK TRANSACTION SURFACE WOOD 2x4 TOP PLATE PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS PARTITION WALL BEYOND 1''/2" THK. x 12" W. TRANSACTION SHELF ® 3'-8" AFP. 11/2 - THK. x 25" D. COUNTERTOP SURFACE a 2'-6" AFF. CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND -- 2" ACCENT BAND 2" ACCENT BAND a EQUAL EQUAL EQUAL WOOD VENEER J w 1'/2" THK COUNTER 8 N —2" ACCENT BAND N TOP SURFACE "' w WOOD VENEER Q N Z WOOD VENEER 3 RECEPTION - OUNTERTOr7; ACCENT A–J SCALE: 3ie =1,_O, EPTH � �2" BAND N 1 N W PmD Pm —WOOD VENEER d 3 SPACED m I6" OC s – I'�2" THK, 25" D 0 POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 = `" 4" H. BASE ^ –� SCALE: BV' I'-0" ADJ. SHELVES TYPICAL) P SCRIBE 6 WALL (TYPICAL) 4" WIRE PULLS- TYP. 2" H. VALANCE 4"H. BACKSPLASH 111/2" THK, 25" D. COUNTERTOP SURFACE CONT. 2X4 LEDGER BOARD WITH PLAM FINISH FOR COUNTERTOP SUPPORT LOCKABLE (3) DRAWER BASE CABINETS- TYP. 4" H. BASE ELEVATION AT PRIVATE 8 OFFICE '4 -3 SCALE: %"=1'-0" RUN COUNTERTOP BEHIND WALL INTO PERPENDICULAR WALL BEYOND - WRAP BACKSPLASH- SEE PLAN 4"H. BACKSPLASH 25" D. COUNTERTOP f]_'LA8NA'ETAINLES8 STEEL 0 PULL AS MRYD BY IKEA : ("601381.59)- TYP. `4 ADJ. SHELF MINI -FRIDGE WITH GLA55 DOOR I -22 ° 1'-11'= 4" H. BASE 3' NOTES: -64"t I. PRIOR TO FABRICATION, VERIFY EXISTING COLUMN LOCATION IN FIELD. MILLWORK SIZES AND DIMENSION TO BE DICTATED BY FINAL LOCATION. 2. PRIOR TO FABRICATION, VERIFY REFRIGERATOR SIZE TO BE SUPPLIED BY OWNER AS THIS MAY AFFECT OVERALL HEIGHT AND CABINET WIDTH. 3. UNDER COUNTER REFRIGERATOR MUST MEET ADA REQUIREMENTS / SPECIFICATIONS. ELEVATION AT '3 BEVERAGE STATION SCALE: 3b" - 1 -ID" A-3 AM I''2" THK TRANSACTION SURFACE WOOD 2x4 TOP PLATE PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS PARTITION WALL BEYOND 1''/2" THK. x 12" W. TRANSACTION SHELF ® 3'-8" AFP. 11/2 - THK. x 25" D. COUNTERTOP SURFACE a 2'-6" AFF. CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND sxa" GYPSUM BOARD ON INSIDE FACE- PAINTED P.T. 2x4 SILL PLATE SECTION AT BUSINESS DESK Y1/-3 SCALE: Ii2 1,_1,-0,l -- 2" ACCENT BAND 2" ACCENT BAND a WOOD 2x4 LEDGER BOARD WOOD VENEER J w 1'/2" THK COUNTER —2" ACCENT BAND N TOP SURFACE "' w WOOD VENEER Q N Z WOOD VENEER 3 RECEPTION - OUNTERTOr7; ACCENT A–J SCALE: 3ie =1,_O, EPTH � �2" BAND N W 2 x 4 WOOD STUDS —WOOD VENEER d 3 SPACED m I6" OC —4" H. BASE F1 sxa" GYPSUM BOARD ON INSIDE FACE- PAINTED P.T. 2x4 SILL PLATE SECTION AT BUSINESS DESK Y1/-3 SCALE: Ii2 1,_1,-0,l EQUAL I. EQUAL SCALE: 3b" = I'-0" 2"0 STEEL POE FOR COUNTER TOP SUPPORT NOTE: – " NOTE: v -- 2" ACCENT BAND MAINTAIN 1''/2" OVERHANG AT SEE FINISH DRAWINGS FOR 0 ELEVATION 8 –WOOD VENEER AT RTO "' –2" ACCENT BAND N .I WOOD VENEER 3 RECEPTION - DESK A–J SCALE: 3ie =1,_O, EQUAL I. EQUAL SCALE: 3b" = I'-0" 2"0 STEEL POE FOR COUNTER TOP SUPPORT NOTE: – " NOTE: v -- 2" ACCENT BAND MAINTAIN 1''/2" OVERHANG AT SEE FINISH DRAWINGS FOR ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION ELEVATION 8 –WOOD VENEER AT RTO "' –2" ACCENT BAND N WOOD VENEER 3 RECEPTION - DESK A–J SCALE: 3ie =1,_O, WOOD 2x4 TOP PLATE WOOD 2x4 LEDGER BOARD 0/2" THK COUNTER TOP SURFACE 2 x 4 WOOD STUDS SPACED 9 16" O.C. e/e" GYPSUM BOARD ON INSIDE FACE- PAINTED e/e" GYPSUM BOARD — P.T. 2x4 SILL PLATE 4" H. BASE SECTION AT BUSINESS DESK A–� SCALE: /2"=1'-O" PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT BEYOND II12" THK x 25" D. COUNTERTOP SURFACE 0 2'-6" AFP. BEYOND Ilii" THK x 25" D. COUNTERTOP SURFACE s 2'-6" AFP, 1112" THK x 12" W. TRANSACTION SHELF 6 3'-8" AFF. WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND I Rw R= ELEVATION SCALE: 31e"=1' -0" –1" SCRIBE O WALL- TYPICAL –ADJ. SHELVES -- 2" ACCENT BAND w 2'-10" 2'-0" 2'-6" NOTE: COORD. WITH SINK I" SCRIBE sWALL- 2x4 BLOCKING FOR SUPPLIED BY P.C. TYPICAL COUNTER ATTACHMENT PROVIDE ADJ. SHELVES AS NEEDED BLOCKING IN (TYPICAL) Iii " THK MARINE 2'-1" WALL AS 2 - NEEDED GRADE PART. BD. W/ 8 –WOOD VENEER - 9 RTO "' –2" ACCENT BAND N WOOD VENEER PLASTIC LAMINATE FINISH- TYP. FOR - O _ r1 4" H. BASE SECTION AT BUSINESS DESK A–� SCALE: /2"=1'-O" PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT BEYOND II12" THK x 25" D. COUNTERTOP SURFACE 0 2'-6" AFP. BEYOND Ilii" THK x 25" D. COUNTERTOP SURFACE s 2'-6" AFP, 1112" THK x 12" W. TRANSACTION SHELF 6 3'-8" AFF. WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND I Rw R= ELEVATION SCALE: 31e"=1' -0" –1" SCRIBE O WALL- TYPICAL –ADJ. SHELVES W 2'-10" 2'-0" 2'-6" NOTE: COORD. WITH SINK I" SCRIBE sWALL- 2x4 BLOCKING FOR SUPPLIED BY P.C. TYPICAL COUNTER ATTACHMENT PROVIDE ADJ. SHELVES AS NEEDED BLOCKING IN (TYPICAL) Iii " THK MARINE 2'-1" WALL AS 2 - NEEDED GRADE PART. BD. W/ 8 9 - N (TYPICAL) "' PLASTIC LAMINATE FINISH- TYP. FOR –4" WIRE PULLS- TYP. – 2" H. VALANCE –4" H. BACKSPLASH - _ r1 � 4" WIRE PULLS- TTP. ENTIRE COUNTER 2" H. VALANCE PL -4 M – 4" H. BACKSPLASH ACCESS PANEL - NOTE: 0 PANEL FINISH: 11/2" THK., 25" D. PL -I N �p W� – I'�2" THK, 25" D 0 COUNTERTOP SINK SECTION SURFACE: SS -I I2 COUNTERTOP SURFACE: 55-I `" 4" H. BASE ^ –� SCALE: BV' I'-0" 1 Q W – 4' H. BASE ELEVATION AT >> STAFF LOUNGE 114 SCALE: 3ie" = 1'-0" A-3 ALUMINUM FRAME -LESS GLASS ATTACHMENT AS SUPPLIED BY 'C.R. LAURENCE COMPANY CO., INC.' (OR EQUAL) �/4" CLEAR TEMPERED GLASS PANELS LEAVE GAP BETWEEN WINDOW AND GLASS PANELS- V.IF. ALUMINUM FRAME -LESS GLASS ATTACHMENT AS SUPPLIED BY 'CR. LAURENCE COMPANY CO., INC.' (OR EQUAL) 1x8 WOOD CAP- MIN. 3/4" OVERHANG ALL SIDES 214" WOOD APRON PAINTED GYPSUM BOARD 4" BASE 1112" THK x 25" D. COUNTERTOP SURFACE 2'-6" AFP. 4" H. BACKSPLASH 3"0 STEEL POST FOR COUNTERTOP SUPPORT NOTE: ELEVATION SIMILAR OTHER SIDE. AT PRIVATE 1 0 wri W e O _ r1 � N W� LU I� 1 Q W ti 0L 0 W 4 N p Q ~ � Z Q U cp LU � l i W v' ry N l� d) V w Z O X LL —w wz 0 LLI 4 � Q q U d w _ 0 SHEET NO, TOILET ROOM IIT ENLARGED TOILET ROOM PLANS A—F SCALE: I SIGN SPECIFICATIONS CODE- ADA COMPLIANT SIGNAGE MANUF. BY- SETON STYLE - TOILET ROOM -ECONOMY BRAILLE SIGNS- RESTROOMS DOOR EXIT- STANDARD BRAILLE SIGNS- EXIT SIZE- TOILET ROOM- 6x9, EXIT- 8x2 NOTE, SUBMIT ROOM IDENTIFICATION SHOP DRAWINGS FOR REVIEW AND COMMENT PRIOR TO ORDERING - �. )OR ryl 81i © IEjI`° TYP. °1-111 LAV. FRONT ELEV. SCALE: I DASHED LINE INDICATES "H" CLEARANCE PROVIDE ADA COMPLIA PIPE INSULATION AT ALL EXPOSED PIPING UNDER HANDICAPPED SINKS. TYP.1111 S r11 TOILET FRONT ELEVATION SCALE: 1i4"=I'-O" ,H" IF TYP. 111-111 LAY. SIDE ELEV. SCALE: I/4"=1' -O" TYP. 111411 TOILET SIDE ELEVATION SCALE: NOTE: ELEVATIONS ARE TO SHOW MOUNTING HEIGHTS OF TOILET FIXTURES ONLY. FOR LOCATIONS OF ACCESSORIES SEE ENLARGED PLANS ABOVE AND FURNISH TO OWNER FOR APPROVAL. GENERAL CONTRACTOR TO SUBMIT UP TO (4) FOUR MASTER KEYS TO OWNER -KNOCKDOWN FRAMES WILL NOT PERMITTED ON THIS PROJECT. DOOR NOTES I. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR / FRAME SIZES, DIMENSIONS, DOOR SWINGS, DOOR / FRAME MATERIALS, DOOR / FRAME TYPES, FRAME WIDTH AND DEPTH, THROAT DEPTH AND FRAME HEAD HEIGHT. 2. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR QUANTITIES PRIOR TO ORDERING. 3. INTERIOR GLAZING IN DOORS TO BE 1/4" THICK CLEAR, TEMPERED GLASS. 4. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DOOR HARDWARE REQUIREMENTS FOR ALL FRAMES INDICATED. ALL SUBMITTALS ISSUED TO THE ARCHITECT SHALL REFLECT THIS FIELD vERIFIED COORDINATION, B. ALL FRAMES SHALL BE SHIMMED / CAULKED IN ACCORDANCE WITH ACCEPTED PRACTICES 6. REFER TO PLANS FOR PROPER DOOR SWINGS T. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR UNDERCUT AND LOUVER LOCATIONS WITH MECHANICAL DRAWINGS 8. VERIFY ALL DOOR STYLES WITH OWNER DOOR TYI=ES: 3'-4" • R.O.- V.IF. ON LATCH SIDE d O O OF DOOR MANUF. / MODEL NO. z pj TACTILE CHARACTERS BRAILLE SHALL v W m 9HALL BE 48" MIN. AFF. TO BE 48" MIN. AFF. I HR. RATED DOOR N BASELINE OF LOWEST TO 60" MAX, CHARACTER 4 60" MAX. APF. TO SEf 5CHED E AFF. TO SAME. !ANSI BASELINE OF 'YPII'-DI O INDICATED AND FURNISH TO OWNER FOR APPROVAL. GENERAL CONTRACTOR TO SUBMIT UP TO (4) FOUR MASTER KEYS TO OWNER -KNOCKDOWN FRAMES WILL NOT PERMITTED ON THIS PROJECT. DOOR NOTES I. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR / FRAME SIZES, DIMENSIONS, DOOR SWINGS, DOOR / FRAME MATERIALS, DOOR / FRAME TYPES, FRAME WIDTH AND DEPTH, THROAT DEPTH AND FRAME HEAD HEIGHT. 2. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR QUANTITIES PRIOR TO ORDERING. 3. INTERIOR GLAZING IN DOORS TO BE 1/4" THICK CLEAR, TEMPERED GLASS. 4. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DOOR HARDWARE REQUIREMENTS FOR ALL FRAMES INDICATED. ALL SUBMITTALS ISSUED TO THE ARCHITECT SHALL REFLECT THIS FIELD vERIFIED COORDINATION, B. ALL FRAMES SHALL BE SHIMMED / CAULKED IN ACCORDANCE WITH ACCEPTED PRACTICES 6. REFER TO PLANS FOR PROPER DOOR SWINGS T. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR UNDERCUT AND LOUVER LOCATIONS WITH MECHANICAL DRAWINGS 8. VERIFY ALL DOOR STYLES WITH OWNER DOOR TYI=ES: R.O.- 3'-0" O 3'-4" • R.O.- V.IF. TAG DESCRIPTION MANUF. / MODEL NO. REMARKS A COAT AND BUMPER HOOK CONFIRM WITH OWNER MOUNT 48" AFF. TO CENTERLINE 0 I HR. RATED DOOR CONFIRM WITH OWNER MOUNT 48" AFF. TO BOTTOM 5402 BRADLEY ASSEMBLY WHERE SEf 5CHED E S SCHED LE CONFIRM WITH OMER MOUNT 40" AFP. MAX TO BOTTOM O INDICATED CONFIRM WITH OWNER MOUNT 42" APF, TO USABLE LEVERS - GRAB BARS 36" LONG (PEENED: P THK, FIRE RATED,HOLLOW MOUNT 34" AFF. TO CENTERLINE SOLID CORE GRAB BARS 42" LONG (PEENED)812-001-42-2 BRADLEY MOUNT 34" AFF, TO CENTERLINE CLEAR TEMPERED GRAB BARS I8" LONG (PEENED) WOOD DOOR / METAL TOILET ACCESSORY SCHEDULE NOTES : GLASS. GLASS SPEC PROVIDE REQUIRED BLOCKING FOR ALL 4, HANDICAPPED FIXTURE MOUNTING HEIGHTS: DOOR WATER CLOSET- IT" MIN. TO 19: MAX, AFF. / ETCHED ON GLA55- TO TOP OF SEAT HOLLOW METAL / IHR RATED �., 9 TENSILE STRESSES SHALL ALSO MEET THE 250 Ib. POINT LOAD WHERE INDICATED DOOR FRAME - 0i2" MAX BOWL DEPTH DOOR ALL ACCESSORIES TO BE INSTALLED PER CURRENT A.D.A. 5. INSTALL INSULATION ON PLUMBING PIPING REQUIREMENTS. UNDER LAv'S AS REQUIRED BY A.D.A. 3, ASSEMBLY r. SOLID CORE WOOD ACCESSORY SURFACES IN CONTACT WITH WALL HOLLOW DOOR METAL DOOR \ \ FRAME N \ A NOTES: O B O O I. NO WIRE MESH IN GLAZING WILL BE PERMITTED 2. SEE SCHEDULE FOR FIRE RATING LOCATIONS R.O.- 3'-0" O FRAME TYPES: SCALE: Ilii"=1'-0" II GYP. BD, OR 5/6P.R GYP. BD. 3 m II 3 2x4 WOOD STUDS CONT. CAULK — (TYP. EA. SIDE) L INTEL TYf=ES SCALE: 11/2"=I' -O" s/e" GYP, BD. OR s/g" RR. GYP. BD. (2) 2x4 WOOD STUD — W/ PLYWOOD SPACER 1i4" THK, CLEAR TEMPERED GLASS. GLASS SPEC ETCHE ON GLASS- WHERE INDICATED SOLID CORE WOOD DOOR H.M. FRAME 4 3/4" ANCHORS (3 MINIMUM PER JAMB) ANCHORS (3 MINIMUM PER JAMB) EXISTING CONSTRUCTION V.IF. s HOLLOW METAL FRAME HOLLOW METAL FRAME PRIMED AND PAINTED (TYP.)PRIMED AND PAINTED (TYP.) 8 SEALANT BOTH SIDES EXISTING CON - HOLLOW METAL FRAME PRIMED AND PAINTED 53/4. (TYP.) HOLLOW METAL FRAME PRIMED AND PAINTED L-2 (TYP.) OF Brian A. Clark 404258 0 1WU `-4 Q 0 ti 00 111111 O l -1-r Hardware: I�IWO Product Specified Manufacturer Equivalent Manufacturer O ¢� 1(1n W 1 Hinges McKinney Sommer, Hager F - Cylindrical Locks Corbin Russwin CL3300 series Yale 540011-N, Sargent 10 line W r --F O CylindersCorbin Russwin Yale, Sargent z Exit Devices Corbin Russwin ED5000 series Yale 7000, Sargent 80 Door Closers Corbin Russwin DC6000 series Norton 8501, Yale 3501 O U0 Protection Plates Rockwood Hiawatha, Trimco Door Stops Rockwood Hiawatha, Trimco Overhead Stops Rixson Sargent, Glynn Johnson Threshold / Gasket Pemko Reese, Zero Q I� ~ NOTE: Use Specified Manufacturers or Listed Acceptable Manufacturers Only. W (Y Z Other Products Implied on shop drawings will be rejected without prior approval. O U U LU (j) Manufacturer's Abbreviations Q 1. MK - McKinney 2. RO - Rockwood 3. RU - Corbin Russwin (� 4. RF - Rixson 5. PE - Pemko 6. AD -Adams Rite Hardware Schedule cp L Set: 1.0 U 6f CO Doors: 101 0) 3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D MK nr�' 1 1 Exit Device (rim, classroom) ED5200 PR955 6P MK 630 RU lL r 1 1 Closer (surface) DC621OAl2 689 RU 1 Kick Plate K1050 10" high 4BE CSK US32D RO N 1 Threshold 273x224AFGT x LAR MSES25SS PE O z 1Sweep 3452CNB x LAR PE r— ,n�/, to Set: 2.0 Doors: 104, 105, 112, 114 LU Z �' 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK L" 0 X 1 Cylindrical Lock (passage) CL3310 PZD 626 RU z 1 Door Stop 409 US32D RO U- 3 Silencer 608 RO z Set: 1 Q Doors: 113 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (storeroom) CL3357 PZD MK 626 RU Z dl 1 Surface Overhead Stop 10-X36 630 RF W 3 Silencer 608 RO Set: 4.0 Doors: 117, 12013 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK z U <rW 1 Cylindrical Lock (office) CL3351 PZD MK 626 RU LU 1 Door Stop 409 US32D RO lL 3Silencer 608 RO = rr Q l TL Set: 1 Doors: 111, 116,119 \11 Q 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (privacy) CL3320 PZD 626 RU 1 Door Stop 409 US32D RO 3Silencer 608 RO 3 NO, I TOILET ACCESSOR'I SCHEDULE TAG DESCRIPTION MANUF. / MODEL NO. REMARKS A COAT AND BUMPER HOOK CONFIRM WITH OWNER MOUNT 48" AFF. TO CENTERLINE 0 PAPER TOWEL DISPENSER TOILET TISSUE DISPENSER CONFIRM WITH OWNER MOUNT 48" AFF. TO BOTTOM 5402 BRADLEY MOUNT 28" AFF. TO CENTERLINE P MIRROR CONFIRM WITH OMER MOUNT 40" AFP. MAX TO BOTTOM O SOAP DISPENSER CONFIRM WITH OWNER MOUNT 42" APF, TO USABLE LEVERS 0 GRAB BARS 36" LONG (PEENED: 812-001-36-2 BRADLEY MOUNT 34" AFF. TO CENTERLINE O GRAB BARS 42" LONG (PEENED)812-001-42-2 BRADLEY MOUNT 34" AFF, TO CENTERLINE H GRAB BARS I8" LONG (PEENED) 812-001-I6-2 BRADLEY MOUNT 3S" APF. TO BOTTOM TOILET ACCESSORY SCHEDULE NOTES : I. PROVIDE REQUIRED BLOCKING FOR ALL 4, HANDICAPPED FIXTURE MOUNTING HEIGHTS: ACCESSORIES SUPPLIED BY THE OWNER OR CONTRACTOR WATER CLOSET- IT" MIN. TO 19: MAX, AFF. REINFORCING IN WALLS FOR GRAB BARS SHALL BE CAPABLE TO TOP OF SEAT SUPPORTING AT LEAST A 250 Ib. POINT LOAD, THE SHEAR AND LAVATORY- 21" MIN. TO BOTTOM OF RIM TENSILE STRESSES SHALL ALSO MEET THE 250 Ib. POINT LOAD - 34" MAX TO TOP OF RIM REQUIREMENT. - 0i2" MAX BOWL DEPTH 2. ALL ACCESSORIES TO BE INSTALLED PER CURRENT A.D.A. 5. INSTALL INSULATION ON PLUMBING PIPING REQUIREMENTS. UNDER LAv'S AS REQUIRED BY A.D.A. 3, "H" INDICATES HANDICAPPED ACCESSIBLE FIXTURES. 6, SILICONE SEAL AROUND ALL TOILET ROOM ACCESSORY SURFACES IN CONTACT WITH WALL SURFACE TO AVOID ANY MOISTURE GETTING BEHIND THE ACCESSORY AND INTO THE WALL FRAME TYPES: SCALE: Ilii"=1'-0" II GYP. BD, OR 5/6P.R GYP. BD. 3 m II 3 2x4 WOOD STUDS CONT. CAULK — (TYP. EA. SIDE) L INTEL TYf=ES SCALE: 11/2"=I' -O" s/e" GYP, BD. OR s/g" RR. GYP. BD. (2) 2x4 WOOD STUD — W/ PLYWOOD SPACER 1i4" THK, CLEAR TEMPERED GLASS. GLASS SPEC ETCHE ON GLASS- WHERE INDICATED SOLID CORE WOOD DOOR H.M. FRAME 4 3/4" ANCHORS (3 MINIMUM PER JAMB) ANCHORS (3 MINIMUM PER JAMB) EXISTING CONSTRUCTION V.IF. s HOLLOW METAL FRAME HOLLOW METAL FRAME PRIMED AND PAINTED (TYP.)PRIMED AND PAINTED (TYP.) 8 SEALANT BOTH SIDES EXISTING CON - HOLLOW METAL FRAME PRIMED AND PAINTED 53/4. (TYP.) HOLLOW METAL FRAME PRIMED AND PAINTED L-2 (TYP.) OF Brian A. Clark 404258 0 1WU `-4 Q 0 ti 00 111111 O l -1-r Hardware: I�IWO Product Specified Manufacturer Equivalent Manufacturer O ¢� 1(1n W 1 Hinges McKinney Sommer, Hager F - Cylindrical Locks Corbin Russwin CL3300 series Yale 540011-N, Sargent 10 line W r --F O CylindersCorbin Russwin Yale, Sargent z Exit Devices Corbin Russwin ED5000 series Yale 7000, Sargent 80 Door Closers Corbin Russwin DC6000 series Norton 8501, Yale 3501 O U0 Protection Plates Rockwood Hiawatha, Trimco Door Stops Rockwood Hiawatha, Trimco Overhead Stops Rixson Sargent, Glynn Johnson Threshold / Gasket Pemko Reese, Zero Q I� ~ NOTE: Use Specified Manufacturers or Listed Acceptable Manufacturers Only. W (Y Z Other Products Implied on shop drawings will be rejected without prior approval. O U U LU (j) Manufacturer's Abbreviations Q 1. MK - McKinney 2. RO - Rockwood 3. RU - Corbin Russwin (� 4. RF - Rixson 5. PE - Pemko 6. AD -Adams Rite Hardware Schedule cp L Set: 1.0 U 6f CO Doors: 101 0) 3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D MK nr�' 1 1 Exit Device (rim, classroom) ED5200 PR955 6P MK 630 RU lL r 1 1 Closer (surface) DC621OAl2 689 RU 1 Kick Plate K1050 10" high 4BE CSK US32D RO N 1 Threshold 273x224AFGT x LAR MSES25SS PE O z 1Sweep 3452CNB x LAR PE r— ,n�/, to Set: 2.0 Doors: 104, 105, 112, 114 LU Z �' 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK L" 0 X 1 Cylindrical Lock (passage) CL3310 PZD 626 RU z 1 Door Stop 409 US32D RO U- 3 Silencer 608 RO z Set: 1 Q Doors: 113 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (storeroom) CL3357 PZD MK 626 RU Z dl 1 Surface Overhead Stop 10-X36 630 RF W 3 Silencer 608 RO Set: 4.0 Doors: 117, 12013 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK z U <rW 1 Cylindrical Lock (office) CL3351 PZD MK 626 RU LU 1 Door Stop 409 US32D RO lL 3Silencer 608 RO = rr Q l TL Set: 1 Doors: 111, 116,119 \11 Q 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (privacy) CL3320 PZD 626 RU 1 Door Stop 409 US32D RO 3Silencer 608 RO 3 NO, I a COMcheck Software Version 4.0.2.9 Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 20091ECC Project Title: Dr. John Miller Project Type: Alteration Construction Site: Owner/Agent: 100 East Main Street Dr. John Miller Aspen, CO 81611 Section 2: Interior Lighting and Power Calculation A Area Category Section 3: Interior Lighting Fixture Schedule Designer/Contractor: Christopher Russell Greenman Pedersen Inc 50 Glenmaum National Blvd Sorenson, PA 18505 c D res, Allowed Allowad Watts Walls Itt2 (Bx C) Total Allowed Walls= 2140 A B C D E FixturelD: Description l Lamp l Wattage Per Lamp l Ballast Lamps/ #of Fixture (Cx D) Fixture Fixtures, Waft. Offics(2140 sq It) A LED Other Fixture Unit 28W: 1 25 28.5 712.5 B: LED Panel 55W: 1 4 56.1 224.4 C: LED Other Fixture Unit 28W: 1 5 28.7 143.5 D: LED PAR 17W: 1 25 17.1 427.5 F. LED Panel 36W: 1 1 35 35 G: LED PAR 13W: 1 4 13 52 Total Proposed Wafts = 1595 Section 4: Requirements Checklist Lighting Wattage: 5a 1. Total proposed watts must be less than or equal to total slowed watts. Allowed Watts Proposed Watts Complies 2140 1595 Passes Controls, Switching, and Wiring: Nj 2. Daylight zones under skylights more than 15 feet tram the perimeter have lighting controls separate from daylight zones adjacent to N vedical fenestration. 1.3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exreph'ons: ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partilions and containing two or fewer light fixtures ma not required to have a separate switch for general area lighting. Project TNIe: Dr. John Miter Report date: 08/09/16 Data filename: XaSCR-2016231.00 Miller Dental Aspen CoEledLighting12016-08-09 Comcheck@016-08-09.cck Pagel of 2 11/29/2016