Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.100 E Main St.0040.2016 (15).ACBK
Brian A. Clark, R.A. Ballina Design Group, LLC Architectural & Engineering Services 1610 Adams Avenue Dunmore, Pa 18509 ph. 570.207.0195 fax. 570.207.0198 info@ballinagroup.com Bonnie Muhigirwa 5-December-2016 Plans Examiner City of Aspen Community Development RE: 100 East Main Street Building Plan Review Response Items Dear Bonnie, Enclosed in this letter, please find our official responses to items as detailed on your Building Plan Review Markup Summary send to Ballina on November 25th, 2016. Item One: Provide Cut Sheets for light fixtures that includes maximum wattage Response: Cut Sheets Attached. Item Two: One-hour rated fire resistant floor ceiling to be provided/maintained. Provide detail for assembly and indicate whether lighting, ventilation, etc. is to be part of a drop ceiling or how these penetrations are to be protected. Response: One hour rated floor/ceiling shall be provided per UL #263 as noted on Drawing A-2, Reflected Ceiling Plan throughout entire space. Drop Ceilings shall be located below rated ceiling. All light fixtures recessed in Gypsum Board shall be rated per lighting fixture schedule. All additional lighting shall be located in drop ceiling beneath rated gypsum board ceiling. All exhaust fan and ductwork shall be installed below existing gypsum board ceiling to maintain rating per Keyed Note 4 on drawing M-2. Item Three: Toilet Room 117, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door size reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Brian A. Clark, R.A. Ballina Design Group, LLC Architectural & Engineering Services 1610 Adams Avenue Dunmore, Pa 18509 ph. 570.207.0195 fax. 570.207.0198 info@ballinagroup.com Item Four: Surgery Rooms 111 & 116, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door sizes reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Item Five: Lab119, front approach, pull side of door requires 18” min. maneuvering clearance. Response: Door sizes reduced to 32” minimum. Clearance provided. Please see dimension on attached A-1 and Revised Door schedule A-4. Item Six: Accessible sale/service counter to be provided. Response: Accessible sale/service counter provided. Please see clarifications on A-1 and A-3. Item Seven: Each individually enclosed area is required to have at least one manual control for the lighting serving that area. Each area with a manual control shall allow the occupant to reduce the lighting load by at least 50%. Provide additional plan notes to illustrate how you comply with these two provisions. Response: This requirement does not apply given exceptions per COM Check, please see updated COM Check attached. Markup Summary 100 East Main Subject: Note Page: 2 Page Index: 2 Checkmark: Checked Author: claude Date: 9/6/2016 4:36:18 PM Creation Date: 9/6/2016 4:16:43 PM Color: Unit: Count Measurement: 1 File Name: 100 E Main St Unit 2 Drawing Set.pdf Zoning Comment #2: Sheet CD-1: Please Provide existing and proposed Net Leasable calculations. Existing net leasable for this area has been 2,150 square feet. Section 26.575.020 (I) Measurement of Net Leasable Area and Net Livable Area. I.Measurement of Net Leasable Area and Net Livable Area. The calculation of net leasable area and net livable area shall include all interior space of a building measured from interior wall to interior wall, including interior partitions. Net leasable area and net livable area shall be attributed to the lot or parcel upon which it is developed. Net leasable area includes all interior areas which can be leased to an individual tenant with the exceptions noted below. Net livable area includes those areas of a building that are used or intended to be used for habitation with the exceptions noted below. Garages and carports are exempt from net leasable area and net livable area calculations. claude (5)Measurement: 10 Subject: Note Page: 1 Page Index: 1 Checkmark: Checked Author: claude Date: 9/6/2016 4:57:36 PM Creation Date: 9/6/2016 4:47:48 PM Color: Unit: Count Measurement: 1 File Name: 100 E Main St Unit 2 Drawing Set.pdf Zoning Comment #4: Existing net leasable for this building lists 3 units in the basement as: "commercial Storage". What is the size and location of the mechanical in the basement specific to the dentist office? Identify the space in the basement and Provide detailed mechanical plan for the basement. Subject: Note Page: 1 Page Index: 1 Checkmark: Checked Author: claude Date: 9/6/2016 4:47:36 PM Creation Date: 9/6/2016 4:44:29 PM Color: Unit: Count Measurement: 1 File Name: 100 E Main St Unit 2 Drawing Set.pdf Zoning Comment #3: On Site Plan provide outdoor lighting information. Out door fixtures shall be fully shielded. see section 26.575.150(E).Nonresidential lighting standards. The following lighting standards shall be applicable to all nonresidential properties including mixed uses: a.Outdoor lighting used to illuminate parking spaces, driveways, maneuvering areas or buildings shall conform to the definition for "fully shielded light fixtures" and be designed, arranged and screened so that the point light source shall not be visible from adjoining lots or streets. No portion of the bulb or direct lamp image may be visible beyond a distance equal to or greater than twice the mounting height of the fixture. For example, for a fixture with a mounting height of twelve (12) feet, no portion of the bulb or direct lamp image may be visible from twenty-four (24) feet away in any direction. The light level shall not exceed ten (10) foot-candles as measured three (3) feet above finished grade. Exemptions may be requested for areas with high commercial, pedestrian or vehicular activity up to a maximum of twenty (20) foot-candles. net leasable has not changed outdoor lighting has not changed See NET1 & NET2 See NET1 & NET2 Subject: Note Page: 1 Page Index: 1 Checkmark: Checked Author: claude Date: 9/6/2016 5:00:08 PM Creation Date: 9/2/2016 11:37:55 AM Color: Unit: Count Measurement: 1 File Name: 100 E Main St Unit 2 Drawing Set.pdf Zoning Comment #1: Please provide a site plan with information about the mechanical proposed for the East elevation of the building. What are the dimensions of the mechanical equipment, height in particular? Is the mechanical in the setback? The mechanical shall comply with section 26.575.020(E)(5) Allowed Projections into Setbacks. See Part 500 and find the section under Chapter 26.575 Miscellaneous Supplemental Regulations. http://www.aspenpitkin.com/Portals/0/docs/City/cle rk/municode/coaspent26-500.pdf Subject: Highlight Page: 1 Page Index: 1 Checkmark: Checked Author: claude Date: 9/6/2016 4:46:46 PM Creation Date: 9/6/2016 4:46:46 PM Color: Unit: Count Measurement: 1 File Name: 100 E Main St Unit 2 Drawing Set.pdf SEE A1.1 EXITMECHANICAL - UPPER LEVEL FLOOR PLANM1-1DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW M1-2MECHANICAL - MAIN LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW EXITM1-3MECHANICAL - LOWER LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW M1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW1. SCOPE OF WORKA. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED.B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE ADOPTED INTERNATIONAL MECHANICAL CODE, ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK OF THIS NATURE.C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS.D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT.2. PERMITSA. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES.3. SHOP DRAWINGSA. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ACHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED.4. FLEXIBLE DUCT WORKA. FLEXIBLE TYPE DUCT SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION COMPOSED OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND COATED FABRIC WITH A MINERIAL BASE. FLEXIBLE DUCT CONNECTORS SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50.B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE THAN 8 LINEAR FEET PER RUN.C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR COLLAPSE FLEXIBLE DUCT.5. REFRIGERENTA. PIPING CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH THE MANUFACTURER'S REC0MMENDATIONS AND IN SUCH A WAY AS TO BE INCONSPICIOUS AND FREE FROM ANY POSSIBLE CONDENSATION.B. INSULATE REFRIGERANT LINES WITH ARMOUR-FLEX TYPE INSULATION, SHALL BE TYPE "K" COPPER TUBING, WITH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER.6. DUCTWORKA. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS.B. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED OTHERWISE.C. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK WHICH PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS OTHERWISE SHOWN ON DRAWINGS.D. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS, SMOOTH TURN RADIUS DUCTWORK OR TURNING VANES SHALL BE USED THROUGHOUT WHERE FLOW EXCEEDS 150 CFM.E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH "SMACNA" STANDARDS AND ACCEPTED GOOD PRACTICE.F. ALL DUCT DIMENSIONS SHOWN ARE NET INSIDE VALUES.DIMENSIONS MAY BE CHANGED SO LONG AS THE NET FREE FACE AREA IS MAINTAINED.G. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1-1/2" FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING.H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM OF THE HVAC UNIT SHALL BE INTERNALLY LINED WITH A 1/2" ACOUSTICAL DUCT LINER.7. DRAINAGE PIPINGA. (CONDENSATE) SHALL BE SCHEDULE 40 PVC PIPE WITH SOLVENT JOINTS. PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS SHALL BE ROUTED TO FLOOR DRAIN OR INDIRECT WASTE DRAIN.8. HYDRONIC PIPING - CHILLED & HEATINGA.TYPE "L" COPPER OR SCHEDULE 40 STEEL.B.PIPE INSULATION AS FOLLOWS: HOT WATER PIPE <1.5" 1-1/2" INSULATION>1.5" 2"INSULATIONCHILLED WATER PIPE ALL 1-1/2" INSULATION9. HVAC CONTROLSA. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING AND THERMOSTATS AS REQUIRED.10. ELECTRICALA. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR A. FOR LOCATION OF WIRING FOR EACH HVAC UNIT.11. PIPE SUPPORTSA. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAP TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC PIPING TO BE SUPPORTED EVERY 4 FEET.12. GAS PIPINGA. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS.13. MISCELLANEOUSA. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND SEALED WITH A SEALANT OF HIGH QUALITY AND LONG LIFE, TO PREVENT INFILTRATION OF OUTSIDE AIR INTO CONDITIONED SPACE. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION.B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS.C. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE.D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT.E. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE SPACE.14. TESTING AND BALANCINGA. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED BY AN INDEPENDENT AGENCY, UNDER THE SUPER- VISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. THIS SHALL OCCUR PRIOR TOFINAL INSPECTION AND SHALL INCLUDE HYDRONICS FOR BOILER SYSTEM.15. GUARANTEEA. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE.B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM.16.BOILERA. STATE OF COLORADO BOILER INSPECTION REQUIRED FOR NEW BOILERS, PROVIDE DOCUMENTATION AT FINAL INSPECTION.FAN COIL SCHEDULEEQUIPMENT NO.SERVICESUPPLYAIR(CFM)OUTSIDEAIR(CFM)SUPPLYAIRE.S.P.(IN. W.G.)COOLINGHOT WATER HEATING COILFILTERSSUPPLYFAN(HP)ELECTRICALUNITWEIGHT(LBS.)MANUFACTURER & MODELOPTIONS/ACCESSORIESNOM.(TONS)OUTPUT(MBH)FLOW(GPM)EWT(°F) (MBH)V./PH./HZ.MCAMOCPFC-1UPPER LEVEL BEDROOMS975-0.834931802" TA1/2115/1/601015175MAGIC AIRE HBB-12FC-2UPPER LEVEL KITCHEN/LIVING900-0.834931802" TA1/2115/1/601015175MAGIC AIRE HBB-12 NOTES: 1. PROVIDE WITH MIXING SECTION, FILTERS AND RACK, DX COOLING COIL, 2 ROW HOT WATER HEATING COIL, AND CONTROLLER.AIR COOLED CONDENSING UNIT SCHEDULEEQUIPMENTNO.SERVICENOMINAL COOLING CAPACITY (TON)REFRIG. PIPINGELECTRICMANUFACTURER & MODELOPTIONS/ACESSORIESLIQUIDVAPORV/PH/HZMOP (A)MCA (A)CU-1FC-123/8"3/4"230/1/602515.7LENNOX - #XC16-024SEE NOTES 1, 2, 3CU-2FC-223/8"3/4"230/1/602515.7LENNOX - #XC16-024SEE NOTES 1, 2, 3CU-3AC-1,223/8"5/8"230/1/603018MITSUBISHI - #PUY-A24NHA4SEE NOTES 1, 2, 3 NOTES:1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER.2. OUTDOOR CONDITIONS OF 85 F.3. INDOOR CONDTIONS OF 79 F DB/61 F WB. EXHAUST FAN SCHEDULEEQUIPMENT NO.SERVICELOCATIONCFMEXTERNAL STATIC PRESS (IN.W.G.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESWATTSHPRPMVOLT/PH/HZEF-1RESTROOMSCEILING750.541-1456120/1/60COOK - #GC-140SEE NOTE 1 NOTES:1. SOLID STATE SPEED CONTROL, BACKDRAFT DAMPER, AND VIBRATION ISOLATORS.MAKE UP AIR SYSTEM SCHEDULEEQUIPMENT NO.SERVICESUPPLYAIR (CFM)OUTSIDEAIR (CFM)SUPPLY AIRE.S.P. (IN.W.G.)ELECTRIC HEATERSUPPLY FANUNITSHIPPINGWEIGHT(LBS.)MANUFACTURER & MODELOPTIONS /ACCESSORIESMODELMAX OUTPUTV./PH./HZ.FLADUCTCONNECTIONV./PH./HZ.POWER(W)MCAMOCPMS-1KITCHEN MAKE UP AIR6006000.5MUAH 10/1010 Kw240/1/604210"Ø120/1/60146215151FANTECH #MUAS-650SEE NOTE 1 THRU 3NOTES:1. PROVIDE OPTIONAL ELECTRICAL HEATING ELEMENT AS SPECIFIED ABOVE. PROVIDE A DEDICATED ELECTRICAL CIRCUIT FOR THE ELECTRIC HEATER.2. PROVIDE WITH FMAC CONTROLLER.3. INSTALLER TO INSULATE ENTIRE LENGTH OF THE MAKEUP AIR SYSTEM AND ALL DUCTWORK CONNECTED TO THE SYSTEM.GRILLE-REGISTER-DIFFUSER SCHEDULEEQUIPMENT NO.CONNECTION SIZETYPEMANUFACTURERMODELFINISHOPTIONS/ACCESSORIESSR-13" x 1'-6"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1SR-23" x 2'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1SR-34" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1SR-44" x 3'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1RG-14" x 2'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-25" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-31'-0" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-44" x 2'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1TR-16" x 1'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1NOTES:1. COORDINATE ALL MOUNTING TYPES WITH CEILING, SOFFIT, WALL, OR FLOOR STRUCTURE.HEAT RECOVERY VENTILATOR (HRV) SCHEDULEEQUIPMENT NO.SERVICELOCATIONCFMEXTERNAL STATIC PRESS (IN.W.G.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESWATTSHPRPMVOLT/PH/HZHRV-1VENTILATIONHUNG FROM STRUCTURE5000.75660-VARIABLE120/1/60FANTECH #SHR-6904 NOTES:1.DUCTLESS SPLIT AIR CONDITIONING SYSTEM SCHEDULEEQUIPMENT NO.SERVICECOOLING CAPACITY (MBH)PEAKAIRFLOWCFMSEER (EFFICIENCY)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESMCA (A)MOCP (A)V./PH./HZ.AC-1OFFICE 412,00042515.2--208/1/60MITSUBISHI, #PKA-A12HA4SEE NOTE 1AC-2OFFICE 412,00042515.2--208/1/60MITSUBISHI, #PKA-A12HA4SEE NOTE 1 NOTES:1. THROUGH TWINNING, BOTH AC-1 AND AC-2 ARE CONNECTED TO ONE OUTDOOR UNIT (CU-3).2. PROVIDE ONE HARD WIRED, WALL MOUNTED PAR-31MAA REMOTE CONTROLLER. CONTROL TO SIMULTANEOUSLY CONTROL BOTH INDOOR UNITS.3. PROVIDE MSDD-50TR-E DISTRIBUTION PIPE KIT (REQUIRED FOR COMBING INDOOR UNITS).4. INDOOR UNITS AC-1 & AC-2 TO BE POWERED BY OUTDOOR UNIT (CU-3). M1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWSPLIT SYSTEM DETAILHYDRONIC BASEBOARD SCHEDULEEQUIPMENT NO.LENGTHHEIGHTTHICKNESSNOMINAL HEATOUTPUT(BTU/HR)FLUID FLOWRATE GPMEWT (°F)LWT (°F)MANUFACTURER & MODELFINISHOPTIONS/ACCESSORIESBB-12'-0"10"3.5"1,6001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-24'-0"10"3.5"3,2001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-36'-0"10"3.5"4,8001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-48'-0"10"3.5"6,4001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1NOTES:1. PROVIDE WITH H-3 ELEMENT TYPE.CABINET UNIT HEATER SCHEDULEEQUIPMENT NO.SERVICESUPPLY AIR (CFM)HOT WATER HEATING HEATINGELECTRICALMANUFACTURER & MODELOPTIONS/ ACCESSORIESOUTPUT(MBH)FLOW(GPM)EWT(°F)V./PH./HZ.MOTOR HPCH-1LOBBY23014.11.64180115/1/601/15BEACON MORRIS #RW-1120-02SEE NOTE 1NOTES:1. PROVIDE WITH HOT WATER COIL, PSC MOTOR, WALL SEAL, AND RETURN AIR TEMPERATURE CONTROL.ELECTRIC WATER HEATER SCHEDULEEQUIPMENT NO.CAPACITY(GAL)RECOVERY @ 90DEG. F. RISE (GPH)WATER CONN.HEATINGELEMENTPOWER (KW)V/PH/HZMANUFACTURER & MODELOPTIONS/ACCESSORIESWH-150213/4"9 (TWO 4.5COILS)240/1/60RHEEM, PRO. CLASSIC #PROE50-T2-RH95SEE NOTE 1NOTES:1. PROVIDE WITH OVER TEMPERATURE PROTECTOR, AUTOMATIC THERMOSTAT, TEMPERATURE & PRESSURE RELIEF VALVE.INDIRECT WATER HEATER SCHEDULEEQUIPMENT NOCAPACITY(GAL)RECOVERY (GPH)@115°F DHWNOMINAL MBHINPUT.BOILERCONNECTIONDOMESTIC WATERCONNECTIONMANUFACTURER & MODELOPTIONS/ACCESSORIESWH-153.13781901"3/4"WEIL-MCLAIN: AQUAPLUS 55SEE NOTE 1NOTES:1. PROVIDE WITH 150 PSI PRESSURE RELIEF VALVE. DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWM1-6AIR COOLED CONDENSING UNIT SCHEDULE (ALTERNATE COOLING FOR MAIN LEVEL)EQUIPMENTNO.SERVICENOMINAL COOLING CAPACITY (BTU/HR)REFRIG. PIPINGELECTRICMANUFACTURER & MODELOPTIONS/ACESSORIESLIQUIDVAPORV/PH/HZMOP (A)MCA (A)CU-4HEAT PUMPS168,0007/8"1-1/8"208/3/6011068MITSUBISHI #PURY-P168SEE NOTES 1 THRU 5NOTES:1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER.2. PROVIDE SNOW/HAIL GUARDS.3. PROVIDE 12" QUICK SLING MOUNTAIN RAILS AND BASE PAN HEATERS.4. OUTDOOR CONDITIONS OF 85 F.5. INDOOR CONDTIONS OF 79 F DB/61 F WB.HEAT PUMP SCHEDULE (ALTERNATE COOLING FOR MAIN LEVEL)EQUIPMENT NO.SERVICETYPECOOLING CYCLEHEATING CYCLEPEAKAIRFLOWCFMREFRIG. PIPINGELECTRICMANUFACTURERMODEL #OPTIONS/ACCESSORIESNOMINAL COOLINGCAPACITY (BTU/HR)AIR TEMPERATURESNOMINAL HEATINGCAPACITY (BTU/HR)AIR TEMPERATURESLIQUIDVAPORV./PH/HZMCA (A)MOCP (A)INDOOR DB/WB (°F)OUTDOOR DB/WB (°F)INDOOR DB (°F)OUTDOOR DB (°F)HP-1OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-2OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-3OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-4OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-5OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-6OFFICE #1WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-7OFFICE #1WALL MTD.18,00079/618520,0007204241/4"1/2"208/1/60115MITSUBISHIPKFY-P18SEE NOTE 1HP-8OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-9OFFICE #1WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-10OFFICE #1WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-11OFFICE #1WALL MTD.15,00079/618517,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P15SEE NOTE 1HP-12OFFICE #3WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-13OFFICE #3WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-14OFFICE #3WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-15OFFICE #2WALL MTD.18,00079/618520,0007204241/4"1/2"208/1/60115MITSUBISHIPKFY-P18SEE NOTE 1HP-16OFFICE #2WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-17OFFICE #2WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-18OFFICE #2WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-19LOBBYWALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-20LOBBYWALL MTD.30,00079/618534,0007209183/8"5/8"208/1/60115MITSUBISHIPKFY-P30SEE NOTE 1NOTES:1. PROVIDE WITH THERMOSTATS, REFRIGERANT LINE SETS AS RECOMMENDED BY MANUFACTURER, CONDENSATE PUMP, AND FILTER.BRANCH CIRCUIT CONTROLLER SCHEDULE (FOR ALTERNATE COOLING SYSTEM)EQUIPMENTNO.SYSTEM NO.TYPENUMBER OFPORTSLOCATIONELECTRICALDIMENSIONS LxWxHMANUFACTURE & MODELOPTIONS/ACCESSORIESMCAMOCPV./PH./HZ.BC-11MAIN13ABOVE CEILING1.1208/1/6017" x 44" x 12"MITSUBISHI #CMB-P1013NU-GA1SEE NOTE 1BC-1A1SUB8ABOVE CEILING1208/1/6017" x 26" x 12"MITSUBISHI #CMB-P108NU-GB1SEE NOTE 1NOTES:1. PROVIDE WITH CONDENSATE PUMP. PROVIDE BALL VALVES FOR EVERY PORT ON THE BRANCH CIRCUIT CONTROLLER.VRF SYSTEM PIPING/ELECTRICAL SCHEMATIC EXITMECHANICAL PIPING - UPPER LEVEL FLOOR PLANMP1-1DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW MP1-2MECHANICAL PIPING - MAIN LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW EXITMP1-3MECHANICAL PIPING - LOWER LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW MP1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBOILER SCHEDULEEQUIPMENT NO.SERVICEINPUTCAPACITY(MBH)OUTPUTCAPACITY (MBH)BOILER VOLUME (GALLONS)FLUE/COMB. AIRSIZE (INCHES)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESAMPSV./PH./HZ.BL-1RESIDENCE HEAT/DHW29928074/410120/1/60WEIL-MCLAIN, #EVG-299SEE NOTE 1BL-2 & BL-3OFFICE HEAT/DHW &SNOWMELT2201754.64/410120/1/60WEIL-MCLAIN, #EVG-220SEE NOTE 1NOTES:1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUALRESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, BOILER CIRCULATOR, WALL MOUNT KIT, AND BLOWERMOTOR.RADIANT ZONESMANIFOLDNO.# LOOPSLOOPLENGTHAREA SERVEDGPMMF-13257MASTER BEDROOM1.5MF-12221HIS BEDROOM1.0MF-13257LIVING ROOM1.5MF-11144ENTRY0.5MF-13187KITCHEN/DINING1.5MF-12140MUD/LAUNDRY/PANTRY1.0RESIDENTIAL MECHANICAL PIPING DIAGRAMPUMP SCHEDULEEQUIPMENT NO.SERVICELOCATIONGPMHEAT (FT.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESMAX HPWATTSRPMV./PH./HZ.FLACP-1RESIDENCE HEATINGMECH. ROOM8.2331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-2RESIDENCE HEATINGMECH. ROOM8.2331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-3RESIDENCE RADIANT HEAT CIRCULATIONMECH. ROOM7331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-4RESIDENCE DOMESTIC WATERMECH. ROOM8141/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-5OFFICE SPACE HEATINGMECH. ROOM3032-800VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-6OFFICE SPACE HEATINGMECH. ROOM3032-800VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-7SNOWMELT RECIRCULATIONMECH. ROOM9.8331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1NOTES:1. PROVIDE WITH COMMUNICATION MODULE, CAST IRON CASING, ENGINEERED POLYMER IMPELLER, STAINLESS STEEL SHAFT, FLANGED CONNNECTIONS AND ECM MOTOR. MP1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWOFFICE SPACE MECHANICAL PIPING DIAGRAMHEAT EXCHANGER SCHEDULEEQUIPMENT NO.SERVICEHEATING FLUIDHEATED FLUIDMANUFACTURER & MODELOPTIONS/ACCESSORIESEWT (°F)LWT (°F)GPMΔP (FT)FLUIDEWT (°F)LWT (°F)GPMΔP (FT)FLUIDHX-1SNOWMELT1801309.81.6WATER100140133.5WATER (50% P.G.)TACO, #TB10Tx40NOTES:1.SNOWMELT MANIFOLD PIPING DETAIL MP1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:ASPEN CLINIC 100 EAST MAIN STREETSCALE:AS SHOWN09/04/14PERMITBUILDING REMODEL BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBighorn Consulting Engineers, Inc. Mechanical & Electrical Engineers 569 S. Westgate Dr., Suite 1 Grand Junction, CO 81505 phone: 970-241-8709, fax: 970-241-951412/09/16PERMITBOILER SCHEDULEEQUIPMENT NO.SERVICEINPUTCAPACITY(MBH)OUTPUTCAPACITY (MBH)BOILER VOLUME (GALLONS)FLUE/COMB. AIRSIZE (INCHES)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESAMPSV./PH./HZ.BL-1RESIDENCE HEAT/DHW29928074/410120/1/60WEIL-MCLAIN, #EVG-299SEE NOTE 1BL-2 & BL-3OFFICE HEAT/DHW &SNOWMELT2201754.64/410120/1/60WEIL-MCLAIN, #EVG-220SEE NOTE 1NOTES:1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUALRESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, BOILER CIRCULATOR, WALL MOUNT KIT, AND BLOWERMOTOR.RADIANT ZONESMANIFOLDNO.# LOOPSLOOPLENGTHAREA SERVEDGPMMF-13257MASTER BEDROOM1.5MF-12221HIS BEDROOM1.0MF-13257LIVING ROOM1.5MF-11144ENTRY0.5MF-13187KITCHEN/DINING1.5MF-12140MUD/LAUNDRY/PANTRY1.0PUMP SCHEDULEEQUIPMENT NO.SERVICELOCATIONGPMHEAT (FT.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESMAX HPWATTSRPMV./PH./HZ.FLACP-1RESIDENCE/OFFICE HEATINGMECH. ROOM38.2351.09-VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-2RESIDENCE/OFFICE HEATINGMECH. ROOM38.2351.09-VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-3RESIDENCE RADIANT HEAT CIRCULATIONMECH. ROOM7331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-4RESIDENCE DOMESTIC WATERMECH. ROOM8141/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-5OFFICE BASEBOARD HEATINGMECH. ROOM-----115/1/60-CONTRACTOR TO SELECTSEE NOTE 1CP-6RESIDENTIAL FAN COILSMECH. ROOM6350.68-VARIABLE115/1/606TACO, #VR15SEE NOTE 1CP-7SNOWMELT RECIRCULATIONMECH. ROOM13330.68-VARIABLE115/1/606TACO, #VR15SEE NOTE 1NOTES:1. PROVIDE WITH COMMUNICATION MODULE, CAST IRON CASING, ENGINEERED POLYMER IMPELLER, STAINLESS STEEL SHAFT, FLANGED CONNNECTIONS AND ECM MOTOR.HEAT EXCHANGER SCHEDULEEQUIPMENT NO.SERVICEHEATING FLUIDHEATED FLUIDMANUFACTURER & MODELOPTIONS/ACCESSORIESEWT (°F)LWT (°F)GPMΔP (FT)FLUIDEWT (°F)LWT (°F)GPMΔP (FT)FLUIDHX-1SNOWMELT1801309.81.6WATER100140133.5WATER (50% P.G.)TACO, #TB10Tx40NOTES:1.SNOWMELT MANIFOLD PIPING DETAILM. Blaine Buck12/9/16 MP1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:ASPEN CLINIC 100 EAST MAIN STREETSCALE:AS SHOWN09/04/14PERMITBUILDING REMODEL BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBighorn Consulting Engineers, Inc. Mechanical & Electrical Engineers 569 S. Westgate Dr., Suite 1 Grand Junction, CO 81505 phone: 970-241-8709, fax: 970-241-951412/09/16PERMITBUILDING HEATING BOILER PIPING DETAILM. Blaine Buck12/9/16 A 1.1 SITE PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 5/31/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 10'-2"4'5' 8" 8'-2 3/4" 8"2'-0"6"5'-0"6"9'8'-10 1/2" 8" 5'-0"2'-5 1/4"9'6'-8"16'-11 1/2"13'-8"273 sq ft N 75°09'11"W 200.06' N 75°09'11"W 270.08' CITY MONUMENT SW CORNER BLOCK 66, HORIZONTAL CONTROL S 75°09'11"E 70.02'N 14°50'49"E 110.00'E G EXISTING PLANTERS TO BE REPAIRED OR REBUILT WITH BOARD FORM CONCRETE AND STEEL PANELS TWO STORY BUILDING WITH PARTIAL BASEMENT 42.0 80.080.052.0 3.6 CONC. WALKCONC. WALK BACK OF CURB 6.4 1.81.8ENCROACHMENT LICENSERECEPTION NO. 410027EAST MAIN STREET 100.00' R.O.W. RECORD ALLEY BLOCK 66 20.39' R.O.W. RECORD NEW SLIP-RESISTANTPAVERS ATENTRY WALKEDGE OF PAVED STREET16.5'13.4'8.5' X 18' PARKING SPACE GARMISCH STREET101.00' R.O.W. RECORDPAVED DRIVECONC. WALK1"=10' 0 10 20 U.S. SURVEY FOOT USED CERTIFICATION DATED: _________, THE UNDERSIGNED STATES THAT THE PROPERTY DESCRIBED HEREON WAS FIELD SURVEYED DURING ______________, ____ AND IS ACCURATE BASED ON THE FIELD EVIDENCE AS SHOWN, AND THAT THERE ARE NO DISCREPANCIES OF RECORD, BOUNDARY LINE CONFLICTS, ENCROACHMENTS, EASEMENTS OR RIGHTS OF WAY IN FIELD EVIDENCE OR KNOWN TO ME EXCEPT AS HEREON SHOWN. UNDERGROUND UTILITIES WITH NO ABOVEGROUND APPURTENANCES, AND DOCUMENTS OF RECORD NOT SUPPLIED TO THE SURVEYOR ARE EXCEPTED. THIS SURVEY IS VOID UNLESS WET STAMPED WITH THE SEAL OF THE SURVEYOR BELOW. ________________________________ JOHN M. HOWORTH, P.L.S. 25947 S 14°50'49"W 110.00'N 75°09'11"W 70.02' CONC. WALK NEW FLAGSTONE WALKWAY TOSTAIRS & ELEVATORRED 25947 RED 25947 OVERHANGOVERHANGOVERHANG REMOVE EXISTING CONC. WALK/RAMP, SEE CIVIL DRAWINGS SHORTEN EXISTING PLANTER, USE WATER-PROOFING AT BUILDING WALL, NEW PLANTER WALL TO BE 4" CMU AND COVERED W/ STEEL PLATE OR CONCRETE CONC.WALKDISK 25947 IN CONC. 15' INGRESS AND EGRESS EASEMENT BOOK 202, PAGE 429 AND EASEMENT AGREEMENT RECEPTION NO. 395469 (VACATED, SEE BOOK 194 AT PAGE 7) OVERHANGEXISTINGWINDOW WELLW/ GRATEPLANTERRELOCATE EXISTING GAS LINE & METER AND ELECTRIC PLANTER EXISTING PLANTER TO BE RE-FACED WITH STEEL TALL GRASSES AND FLOWER GARDEN WITH BLACK PEBBLES DNUPEXISTING GAS AND ELECTRIC METER TO BE RELOCATED AROUND CORNER TO ALLOW FOR NEW STAIRS / ELEVATOR NEW SLIP-RESISTANT PAVER WALKWAY ON GRADE TO NEW STAIR. PAVERS TO COMPLY WITH A117.1-2003/303 (TYP.) PROPERTY LINE EXISTING LANDSCAPING BETWEEN BUILDINGS TO BE MAINTAINED OR REVEGETATED AS NEEDED AFTER CONSTRUCTION GRAVEL GRASS EXISTING CONCRETE PAD TO BE REMOVED TALL GRASSES AND FLOWER GARDEN WITH BLACK PEBBLES GRASS STEEL PLATE SIGN FOR NEW MEDICAL OFFICE STEELPLATE SIGNFOR NEWMEDICALOFFICES PROTECT EXISTING TREES PROTECT EXISTING TREES PROTECT EXISTING TREES PROTECT EXISTING TREES RECYCLING ENCLOSURE, STEEL PLATE IN FRAME (MATCHES NEW SIGNAGE FRAMES) PAVERS FOR NEW OFFICE ENTRY 4 PROPOSED PARALLEL PARKING SPOTS PUBLIC BUS STOP PROPOSED GRASS PROPOSED GRASS PROPOSED GRASS RAMP CURB FLAGSTONESTAIR W/HANDRAILBOTH SIDES4R@ 5 1/8", 3T@ 1'-0" FOR DETAILED INFORMATION, SEE PINNACLE ENGINEERING DRAWINGS DATED 6-17-14 EXISTING WATER LINE TO REMAIN RELOCATE FENCE TO WITHIN PROPERTY BOUNDARY PROTECT INSIDE TRASH ENCLOSURE WITH APERTURE AT METER NOTE: CROSS-SLOPE ON ALL EXTERIOR WALKWAYS SHALL NOT EXCEED 1:48 RECYCLE TRASH ELEVATOR NEW SLIP-RESISTANT HEATED PAVER WALKWAY ON GRADE TO NEW ELEVATOR. PAVERS TO COMPLY WITH A117.1-2003/303 (TYP.) EXISTING PARKING SPACE TO BE PAVERS IN SAND WITH 4" CONCRETE BORDER FLAGSTONEPATIO TO REMAINCENTERLINE OF NEW DOOR AND WALKWAY STEPS DN RAMP: SEE CIVIL RAMP: SEE CIVILRAMP: SEE CIVIL PROTECT EXISTING TREES NEW RAMP W/ LANDINGS- SEE CIVIL SCALE: 1/8" = 1'-0" CIVIL SITE PLAN line of building 6' - 0" yard box. snow melt manifold ELECTRIC SERVICE AND METERS NEW GAS METER NEW TELEPHONE AND TV SERVICE ENTERS BASEMENT A 2.1 LOWER LEVEL PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 5/31/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16123456789101112D51 D51D54 D56D52D55D53A A E E F F B B 1 1 4 4 6 6 2 2 3 3 5 5 C C D D17'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4" 14'-6"8" 8'5'-6" 4'-10"3 1/2"4'-7" 1'1'9'-1 1/4"3 1/2"EXISTING DOOR LOCATION EXISTING EGRESS DOOR EXISTING WATER LINE TO BE CAPPED. INSTALL NEW LINE FROM WEST SIDE OF BLDG. EXISTING EXTERIOR STAIR TO REMAIN PROPOSED LADDER RAIL DIES INTO DOOR WALL AT MAIN LEVEL. 1' EXTENSION DOES NOT OCCUR AT LOWER LEVEL DOOR NON- UNIT MECH COMMERCIAL STORAGE 3 NON-UNIT HALL COMMERCIAL STORAGE 1 ELEV. MECH. SELF- CLOSING DOOR TENANT FINISH TENANT FINISH CEILING TO BE 1-HOUR FIRE RATED (TYP) EXIT COMMON ELECT. PNL. COMMERCIAL STORAGE 2 SCALE: 1/4" = 1'-0" LOWER LEVEL PLAN NORTH DHW DHW BOILER #1 BOILER #2 BOILER #3 BOILERS WALL MOUNTED SEWER EXITS APPROX. 42" ABOVE FLOOR DOOR EAST SIDE OF ROOM EXISTING FLOOR DRAIN DOESN'T WORK RADIANT VALVES AND PUMPS ON THIS WALL SNOWMELT VALVES AND PUMPS ON THIS WALL NEW FLOOR SINK TO BE INSTALLED NEW EJECTION BASIN TO PUMP BACK INTO SEWER LINE ELECTRIC PANEL CANNOT BE HERE NEW DENTIST OFFICE EQUIPMENT CLOSET FRAMED NICHE FOR ALARM PANEL ERV AT CEILING CORE DRILL SLAB AT CEILING. RUN DUCT TO CEILING AND OUT THROUGH NORTH BRICK WALL TELEPHONE, TV, INTERNET SERVICE ON WALL ELEVATOR EQUIPMENT NEW WATER SERVICE ENTERS BASEMENT HERE DOMESTIC WATER PRESSURE RELIEF VALVE ON WALL FIRE SPRINKLER PRV AND BACKFLOW PREVENTER ON WALL DOMESTIC BACKFLOW PREVENTOR AND WATER METER ON WALL THERE IS NO FLOOR DRAIN FOR WATER SERVICE ENTRY A 2.4 ROOF PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 5/31/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16 CUT SHEET Overview Developed by architectural sheet metal professionals, the Original Polycarbonate™ offers 25 square inches of bonding surface - the larger the base, the greater the holding power. The Original Polycarbonate™ has the largest base available in the industry! Manufactured from clear UV-stabilized polycarbonate material, or in a color that is injected throughout the product and matched to any standard roof panel. Inset base for metal roof panels with stiffening ribs. Apply using tube adhesive or a mechanical fastening application. Innovation Manufactured from UV-stabilized polycarbonate, the unique design of these crystal-like guards suspends the field of snow until the snow and ice gradually melt under the sun’s rays. CUT: Sno Gem® snow guard’s prismatic design was developed by architectural sheet metal professionals with over 100 combined years of on-the-roof experience. CLARITY: Sno Gem® offers a clear prismatic snow guard which retains its crisp, clean and architectural appeal. There’s no metal to rust or stain. Sno Gem® snow guards are unaffected by climate extremes. COLOR: Sno Gem® snow guards can be matched to all industry standard metal roof colors. Sno Gem® also offers an unlimited amount of custom colors to closely match the metal roof panel. The color is injected throughout the product. CARAT: The true measure of a gem’s worth. At the heart of each Sno Gem® is an engineered, multi-directional, multi- purpose drain opening for melting snow and ice to flow freely, plus heat cables can be easily routed through the opening. Dimensions Height: 3.25” - Width: 5” - Length: 5” Applications For Ribbed Panel Metal Roof Systems. Colors Available in Clear or Color to Match Virtually Any Standard Metal Roof Panel Manufacturers. Recommended Accessories Depending on the application, the following accessories are available to ensure proper installation. Original Polycarbonate™ Snow Guard with Inset Base For Metal Roof Systems 3M VHB Tape Application Shown Isopropyl Alcohol Panel Cleaner Surebond SB-190 Adhesive *Seller assumes no responsibility for the warranty. Check your roof manufacturer’s warranty information before installation. A A E E F F B B 1 1 4 4 6 6 2 2 3 3 5 5 C C D D J 18'-5 3/4"43'-2 1/4"18'-5 1/2"18'-5"20'-5"13'-2"2'-6"2'-3/4"13'-4"2'-3/4"17'-3 1/4"19'-3 3/4"4'-7 3/4"25'-2 1/2" 33'-6 1/4"20'-4"3 1/2"8 3/4"3'-9 1/2"3 1/2"3'-4"3'-2 3/4"1 3/4"1'-8""FLAT" ROOF AT NEW ELEVATOR SEE STRUCTURAL DRAWINGS FOR STEEL FRAME AT NEW ROOF AND DOOR SNO-GEM SNOW RETENTION (TYP.) SNO-GEM SNOW RETENTION (TYP.)SNO-GEM SNOW RETENTION (TYP.) REBUILD EXISTING TOP OF CHIMNEY AND INSTALL NEW FLUE-LINER TERMINATE DRYER VENT AT ROOF. PROVIDE RAIN CAP CRICKET AT NEW ROOF VENT TERMINATION FOR LIVING ROOM FIREPLACE SCUPPER PENETRATION AT LOW POINT OR ROOF RECESS SCUPPER DISCHARGES ONTO ROOF AND RUNS INTO WEST GUTTER, DOWNSPOUT NEW METAL FASCIA, TYP. "FLAT" ROOF AT NEW PATIO DOOR NEW UPPER ROOF: MATCH EXISTING ROOF PITCH 1.5:12 V.I.F. EXISTING LOW ROOF PITCH V.I.F. EXISTING ROOF PITCH 1.5:12 V.I.F NEW DECK BELOW REFRAME FLAT ROOF TO SET BELOW EXISTING TO SHIELD MECH. NOTE: REPLACE / REWORK ALL EXTERIOR GUTTERS AND DOWNSPOUTS PER DRAINAGE PLAN V.I.F.V.I.F.V.I.F.RELOCATED MECHANICAL EQUIPMENT. NO GUARDS REQUIRED ACCESS ROOF WINDOW EXISTING ROOF PITCH 1.5:12 V.I.F EXISTING ROOF PITCH 1.5:12 V.I.F EXISTING ROOF PITCH 1.5:12 V.I.F ACCESS ROOF WINDOW TAR AND GRAVEL TAR AND GRAVEL TAR AND GRAVEL TAR AND GRAVEL V NORTH  A/C CONDENSING UNIT FOR FC 1 IN PENTHOUSE A/C CONDENSING UNIT FOR FC 2 IN PENTHOUSE A/C CONDENSING UNIT FOR FUTURE OFFICE 4 A/C CONDENSING UNIT FOR FUTURE OFFICE 3 A/C CONDENSING UNIT FOR FUTURE OFFICE 2 FUTURE DENTIST OFFICE #1 EQUIPMENT 0 I L_ I n A-3 Y FLOOR PLAN SCALE: 11/a"= I'-0" BC D E F 0 OF CO Brian A. Clark 404258 ll' -9 t � 9'-5"• 8'-6" 8'-6" 8'-6" 8'-6" 7'= Il'_m"• 4'-35q"t /� f ✓ 620-16 FT NOTE: ALL DRAWINGS CONTAINED IN THIS PACKAGE ARE BASED ON THE EQUIPMENT AND EQUIPMENT DETAILS CONTAINED ON THE CENTER POINT DESIGN / BENCO DENTAL DRAWINGS INCLUDED AT THE END OF THIS PACKAGE. IF EQUIPMENT OTHER THAN WHAT IS SPECIFIED ON THESE DRAWINGS IS PURCHASED, THE INSTALLATION, UTILITY CONNECTIONS AND SPACE REQUIREMENTS MAY BE DIFFERENT AND IT SHALL BE THE RESPONSIBILITY OF THE OWNER AND HIS/HER CONTRACTORS TO MAKE THE NECESSARY MODIFICATIONS IN THE FIELD TO ACCOMMODATE THIS EQUIPMENT. S. TMENT ROOM n2NT ROOM ROOM #I 10 109 108 101 106 ❑ r CI 104 m O O O O ffl � 104 0 0 0 0 4 ' I y a 0_ � 0 0I os 3 : 3 N� EQUAL 5'-0" EQUAL A-3 EXISTING COLUMNS TO LH REMAIN- COORDINATE FINAL 3 DIMENSIONS IN FIELD - ADJUST THICKNESS OF WALL TO CONCEAL COLUMNS lyn-3 2 Urt-3 O IS O IS O 15 O 15 15 m m 00 m i la A-3 2 2,_5„ 2'-O„ 2_g14�, 2' S�, 112'-0" 2' S,. 2,_l}„: I'-5}' 2_g„ / -NOTE: - TOP OF LOW WALL TO MATCH 6,1-34 aO S SILL HEIGHT OF EXTERIOR EXISTING MECH NICAL WINDOWS 2 CHASE TO REMAIN 105 11 �� Wr-I Il p_$R” I1 2 16 Wr- WT -3 MQ O O 9 14 Ill IB II9 1 I]0 I I IDI S 0 n i s CHECK-IN 1\ Aa 121 A-3 ILIZATI lyr- 120 �� - 102 -SEE NOTE, FOR ENLARGED 1 �� 1 \\ RECEPTION DESK PLAN 1 E -`moi/ 13 • 3 6 p NOTE: SOLID WALLS DEPICT EXISTING FIRE RA ED EXISTING TENANT DEMISING WALL/CHASE TO REMAIN- TENANT SPACE TOILET R.M. GENERAL CONTRACTOR RESPONSIBLE FOR NOT IN SCOPE COORDINATING THE INSTALLATION OF 51/5" FIRE RATED GYPSUM BOARD ON TENANT SID OF EXISTING WALL TO COMPLETE I HR RATED ASSEMBLY LOBBY WITH DEVELOPER UNDER SEPARATE CONTRACT.NOT IN SCOPE o _ _ _ n . 4 NOTE: ALL ARCHITECTURAL DRAWINGS SHALL BE CONSIDERED AN EXTEN51ON OF, AND USED IN COORDINATION AND CONJUNCTION WITH, ALL BENCO / CENTER POINT DESIGN DRAWINGS CONTAINED IN THIS DRAWING PACKAGE (0-6ERIES DRAWINGS) NOTE: GENERAL CONSTRUCTION NOTES: ALL EXISTING EXTERIOR WALLS 70 HAVE ALL FINISH MATERIAL REMOVED 45 PART OF DEMOLITION. GENERAL CONTRACTOR TO PROVIDE AND INSTALL 111/2" FURRING S RIPS AND Na" GYPSUM BOARD ON ALL EXTERIOR WALLS UNLESS OTHERWISE NOTED - TYPICAL ALL EXTERIOR WALLS OF TENANT SPACE- GYPSUM BOARD PROVIDED AND INSTALLED UNDER SEPARATE CONTRACT WI7H DEVELOPER. INSULATION FULL HEIGHT- SEE WALL TYPE. PARTITION LEGEND GENERAL CONSTRUCTION NOTES: Ip GENERAL PARTITION NOTES: I. WHILE FRAMING PARTITIONS AND HANGING DRYWALL, COORDINATE WITH BENGO/CENTER POINT DETAIL 08/02.2 AND GENERALLY LOCATED PER FLOOR I. TOILET ROOMS TO RECEIVE MOISTURE RESISTANT GYPSUM BOARD ON ALL WALLS MECHANICAL CONTRACTOR FOR DUCT LAYOUT, DUCT PENETRATIONS AND RANSFER FULL HEIGHT. GRILL LOCATIONS THRU WALLS ABOVE CEILINGS. OPENINGS SHALL BEPROVIDED PROVIDE FRAMING AND GYPSUM BOARD TO COMPLETE GYPSUM BOARD 2. INFILL STUD CAVITIES SURROUNDING TOILET ROOM WITH 311/2" OR 511/2" SOUND BATT IN WALLS ABOVE CEILINGS TO FACILITATE RETURN AIR MOVEMENT BACK To UNITS- INSULATION FULL HEIGHT- SEE WALL TYPE. COORDINATE WITH MECHANICAL DRAWINGS AND CONTRACTOR. THESE OPENINGS BACKING PER BENCO/CENTER POINT DETAIL 12/02.2 AND LOCATED PER FLOOR Is SHALL BE FRAMED WITH GYPSUM BOARD OR OTHER NON-COMBUSTIBLE M TERIAL 3. ALL WOOD SILL PLATES IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE TO COVER WOOD STUDS. BOARD, GENERAL CONTRACTOR RESPONSIBLE FOR PROVIDING LEVEL TREATED. PROVIDE BLOCKING IN WALL FOR WALL X-RAY/PAN CONTROL NAILER PER SURFACES TO MEET EXISTING WALL THICKNESS. 2. ALL INSULATION AND FACING TO MEET IBC REQUIREMENTS FOR FLAME SPREAD BENCO/CENTER POINT DETAIL 01/022 AND LOCATED PER FLOOR PLAN Q21 4. WHERE WALLS RUN GREATER THAN 10' AFF., PROVIDE 2X4 OR 2X6 HORIZONTAL INDEX (NOT MORE THAN 25) AND SMOKE -DEVELOPED INDEX (NOT MORE THAN 450), WOOD STUDS ON THE FLAT FOR FIRE BLOCKING AT MIDPOINT 3, IN EXISTING BUILDING (FIRST AND SECOND FLOOR) GENERAL CONTRACTOR EXISTING INTERIOR WALL TO HAVE ALL FINISH MATERIAL REMOVED DOWN TO wr-I 43." THICK NON -RATED / SOUND RATED PARTITION RESPONSIBLE OR REPAIRING/PATCHING AND SKIM COATING EXISTING WAL S TO ONE LAYER OF 51/•" GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AT 16" O.C. REMAIN AND PREPARING SURFACES FOR NEW WALL FINISHES. COORDINATE LOCATIONS AND LENGTHS WITH ENLARGED PLAN AND DETAILS. RUN STUDS AND GYPSUM BOARD FROM FINISH FLOOR TO BOTTOM OF ROOF FRAMING. CONTRACTOR TO PROVIDE AND INSTALL METAL FURRING STRIPS AND 51/5" INFILL STUD CAVITY WITH 311/2" SOUND BATT INSULATION FULL HEIGHT. INFILL ALL INSULATION NOTES: GYPSUM BOARD ON ALL INTERIOR SURFACES OF WALL. PROVIDE SOUND BATT GAPS IN GYPSUM BOARD WITH SOUND SEALANT. PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED EXIT SIGN. REFER TO 2/A-4 INSULATION IN TOILET ROOM 117. I. VERIFY ALL EXTERIOR CAVITY WALLS TO RECEIVE 5'1/2" THK. BATT INSULATION (MIN. 0 431/," THICK NON -RATED / NON -SOUND RATED PARTITION R-19) FULL HEIGHT OF WALLS. VERIFY EXISTING INSTALLATION UNDER SEPA ATE ONE LAYER OF 5/5" GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AT 16" O.C. PERMIT AND CONTRACT- COORDINATE WITH BUILDING DEVELOPER BENCO/CENTER POINT DETAIL 09/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1. RUN STUDS FROM FINISH FLOOR TO BOTTOM OF ROOF FRAMING. GYPSUM BOARD TO 2. ALL SOUND ATTENUATION BATT INSULATION TO BE UNFACED 311/2" THICK UNLESS re RUN FROM FINISHED FLOOR TO BOTTOM OF ROOF FRAMING. OTHERWISE NOTED. 'K'- wr-3 43/4" THICK NON -RATED / NON -SOUND RATED LOW WALL PER BENCO/CENTER POINT DETAIL 1O/Q22 AND LOCATED PER FLOOR BACKINPLAN u ONE LAYER OF 11/2" GYPSUM BOARD ON EACH SIDE OF 351/5" METAL STUDS (22 GA.) AT CONSTRUCTION KEY NOTES: QG 16" O.C. RUN STUDS AND GYPSUM BOARD FROM FINISHED FLOOR TO 42" A.FF. UNLESS CABINET. OTHERWISE NOTED. BOTTOM PLATE TO BE FLEX TRACK TO ACHIEVE DEISRED 0 PROVIDE UP TO FOUR (4) ROWS OF 2X6 WOOD BLOCKING BETWEEN 5TU 5 FOR RADIUS. (SEE DETAILS A/3). COORDINATE FINAL HEIGHTS WITH ALL ARCHITECTURAL MILLWORK- BASE AND/OR OVERHEAD CABINETS- (EITHER BY GC, BENG OR DETAILS AND INTERIOR ELEVATIONS. OTHERS) COORDINATE EXACT HEIGHTS AND LENGTHS OF BLOCKING WIT MILLWORK DRAWINGS (GENERALLY BLOCKING TO BE CENTERED AT 5", 36", 56" AND 54" A,FF1 <E�43q" ONE HOUR RATED (UL' U305) / SOUND RATED PARTITION SEE BENCO/CENTER POINT DETAILS 01, 02, 03 1 04 /02.2 FOR GENERAL DETAIL ONE LAYER OF 5/e" FIRE RATED GYPSUM BOARD ON EACH SIDE OF 2x4 WOOD STUDS AND COORDINATE LOCATION PER PLAN Q21, AT 16" O.0 (WITH TOP AND BOTTOM WOOD PLATE). RUN STUDS AND GYPSUM BOARD 0 PROVIDE BLOCKING WALL FOR WALL MOUNTED PAN/CEPH. UNIT PER FROM FINISHED FLOOR TO UNDERSIDE OF FRAMING ABOVE. FIRE CAULK TOP AND BENCO/CENTER POINT DETAIL 05/02.2 AND LOCATED PER FLOOR PLAN 02.1 BOTTOM OF GYPSUM BOARD WITH NELSON FIRE STOP CAULK SILICONE SEALANT. ALL EXTEND MORE THAN 4" OFF FACE OF WALL). PENETRATIONS THROUGH THIS WALL MUST BE FIRE STOPPED. INFILL ALL STUD 3 0 PROVIDE BLOCKING WALL FOR WALL MOUNTED X-RAY UNIT PER BENCO CENTER CAVITIES WITH 311/2" SOUND BATT INSULATION FULL HEIGHT. POINT DETAIL 06/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1 O PROVIDE BLOCKING WALL FOR WALL MOUNTED TV/MONITOR. COORDINAE T FINAL LOCATION IN FIELD WITH OWNER PRIOR TO INSTALLATION. AT MASONRY IALL Q LOCATIONS, PROVIDE PROPER ANCHORING- SEE MANUFACTURES INSTAL ATION FOR TYPES AND LOCATIONS. SPECIFICATIONS, EXISTING TOILET RM. NOT IN SCOPE O PROVIDE BLOCKING IN CEILING FOR CEILING MOUNTED LIGHT PER Ip PROvIDE BLOCKING IN WALL FOR HANDICAPPED ACCESSIBLE TOILET ROOM BENGO/CENTER POINT DETAIL 08/02.2 AND GENERALLY LOCATED PER FLOOR SINK/VANITY TO P INSTALLATION. COORDINATE BLOCKING WITH DETAIL 12/A-3, PLAN Q2.1. 15 PROVIDE FRAMING AND GYPSUM BOARD TO COMPLETE GYPSUM BOARD O PROVIDE BLOCKING FOR CEILING MOUNTED COMPUTER / MONITOR SUPPORT OPENING- MATCH WALL THICKNESS AND PROVIDE SMOOTH, LEVEL SURFACES. �Cwtt% BACKING PER BENCO/CENTER POINT DETAIL 12/02.2 AND LOCATED PER FLOOR Is PREP SURFACE OF NEW WALL OPENING WITH MIN. 11/2" FURRING AND 11/2" GYPSUM O PLAN 02.1. BOARD, GENERAL CONTRACTOR RESPONSIBLE FOR PROVIDING LEVEL O PROVIDE BLOCKING IN WALL FOR WALL X-RAY/PAN CONTROL NAILER PER SURFACES TO MEET EXISTING WALL THICKNESS. BENCO/CENTER POINT DETAIL 01/022 AND LOCATED PER FLOOR PLAN Q21 n EXISTING INTERIOR WALL TO HAVE ALL FINISH MATERIAL REMOVED DOWN TO O PROVIDE BLOCKING IN WALL FOR COUNTERTOP SUPPORT ATTACHMENT. STRUCTURAL /FRAMING COMPONENTS UNDER DEMOLITION PHASE. GENERAL ZOLIL COORDINATE LOCATIONS AND LENGTHS WITH ENLARGED PLAN AND DETAILS. X CONTRACTOR TO PROVIDE AND INSTALL METAL FURRING STRIPS AND 51/5" I� GYPSUM BOARD ON ALL INTERIOR SURFACES OF WALL. PROVIDE SOUND BATT O PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED EXIT SIGN. REFER TO 2/A-4 INSULATION IN TOILET ROOM 117. Q FOR DETAILS. l5 PROVIDE BLOCKING IN WALL FOR WALL MED-GAS/CYLINDER BACKING PER Im PROVIDE HANDICAPPED COMPLIANT, WALL MOUNTED TOILET ROOM SIGN. REFER cn BENCO/CENTER POINT DETAIL 09/Q2.2 AND LOCATED PER FLOOR PLAN Q2.1. O TO 2/A-4 FOR DETAILS. re PROVIDE BLOCKING IN WALL FOR WALL ANALGESIA/VAC/NITROGEN OUTLET 'K'- PER BENCO/CENTER POINT DETAIL 1O/Q22 AND LOCATED PER FLOOR BACKINPLAN u PROVIDE CLASS RATED 101b. FIRE EXTINGUISHER- TO BE LOCATED IN BASE QG :3 CABINET. 12 PROVIDE FIRE EXTINGUISHER AND CABINET. CABINET TO BE LARSEN, CAMEO U SERIES MODEL • C -2409-R, STEEL TRIM AND DOOR, RECESSED, 5/16" TRIM LnULu, PROJECTION, CLEAR BUBBLE WITH BLACK LETTERS. EXTINGUISHER TO BE ABC lL MPIO WITH APPROPRIATE BRACKET FOR UNIT AND CABINET. TO COMPLY WITH ADA INSTALLATION GUIDELINES, INSTALL SO TOP OF EXTINGUISHER HANDLE AT Z 48" MAXIMUM ABOVE FINISH FLOOR CABINET (INCLUDING BUBBLE) CANNOT oW EXTEND MORE THAN 4" OFF FACE OF WALL). 3 NO, 13 PROVIDE BLOCKING IN WALL TO MOUNT ADA GRAB BARS (MEETING ICC/ANSI AII11 SECTION 609.5 FOR STRUCTURAL STRENGTH- 250 Ibs VERT. < HORIZ. FORCE) REQUIREMENTS AND OTHER TOILET ROOM ACCESSORIES. COORDINATE WITH 1/A-1 Q FOR TYPES AND LOCATIONS. C_4 001 U cp LLI ryJ, �N 00 lL 1W� �Cwtt% O N O V N V O Z ZOLIL O X I� w n� v/ Q � Q cn O W w �4 > :3 5� <r U LnULu, Q lL Z oW 3 NO, 0 Q U cp LLI Ii 1� lL 01 �Cwtt% N O V N V W Z ZOLIL O X w n� v/ Q � Q W w �4 > :3 <r U LnULu, Q lL Z Q 3 NO, 1 15" W DRAWER/FILE – BASE CABINET- TYP 11/2" THK. TRANSACTION ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND COUNTER TOP SURFACE EQUAL EQUAL EQUAL 3 ® 3'-8" APF.: TRANSACTION SHELF: 1'/2" THK COUNTER 21/2"9 GROMMETS IN a -x CONTINUOUS LEDGER BOARD FOR COUNTER WORK SURFACE TOP SUPPORT PMD Pm COUNTER- TYP. RECEPTION 11/2" THK., 25" D. 15" WIDE DRAWER BASE DESK TRANSACTION COUNTER ° THK. SLOPING BRACKET TOP SURFACE ® 2'-6" AFF.: \ o 0/2" THK SLOPING SUPPORT \� 15" W. BASE CABINET: PANEL AS NECESSARY FOR 4" H. BASE PmD Pm COUNTER TOP SUPPORT / d 3 W DCA LE LOW WALL BASE CABINET-INET-TYP. z E ° RADIUS: 5'-4" a 21i2"4 GROMMETS IN A-3 A-3 WORK SURFACE POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 COUNTER- TYP. `" 1112" THK. TRANSACTION _ \ R=13" COUNTER TOP SURFACE % ® 3'-8" APF.: x / o Q I''2" THK., 25" D. A -x \ TRANSACTION COUNTER TOP – 4' H. BASE SURFACE ® 2'-6" AFF.: 0 0l ENLARGED PLAN AT REI A–� SCALE: ._0.. NOTE: I MAINTAIN II'2" OVERHANG AT ALL COUNTER TOP SURFACES 3 u MAINTAIN 1✓2" OVERHANG AT Ott YINIOM VKRWIN= YVK ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND ELEVATION EQUAL EQUAL EQUAL Iii," THK, x 12" D. 1 0 TRANSACTION SHELF: 1'/2" THK COUNTER AT —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT PMD Pm THK. x 25" D. WORK RECEPTION 3 RECEPTION 15" WIDE DRAWER BASE DESK WITH LOCKING DRAWERS Ye -3 SCALE: THK. SLOPING BRACKET EPTH FOR COUNTER TOP �2" BAND SUPPORT AS NEEDED N 15" W. BASE CABINET: 1 N 4" H. BASE PmD Pm —WOOD VENEER d 3 SPACED m I6" OC � N – I'�2" THK, 25" D e POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 = `" 4" H. BASE ^ –� SCALE: BV' I'-0" 1 Q W NOTE: I MAINTAIN II'2" OVERHANG AT ALL COUNTER TOP SURFACES 3 u MAINTAIN 1✓2" OVERHANG AT Ott YINIOM VKRWIN= YVK ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION 2" ACCENT BAND ELEVATION EQUAL EQUAL EQUAL Iii," THK, x 12" D. WOOD VENEER TRANSACTION SHELF: 1'/2" THK COUNTER AT —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT w WOOD VENEER Q THK. x 25" D. WORK RECEPTION 3 RECEPTION 15" WIDE DRAWER BASE DESK WITH LOCKING DRAWERS Ye -3 SCALE: THK. SLOPING BRACKET PAINTED GYPSUM BOARD ELEVATION AT s RECEPTION DESK A–� SCALE: 3/e"=1' -O" SOFFIT- SEE CEILING PLAN 2" ACCENT BAND FOR RADIUS EQUAL EQUAL EQUAL Iii," THK, x 12" D. WOOD VENEER TRANSACTION SHELF: 1'/2" THK COUNTER 4"H. BACKSPLASH: —2" ACCENT BAND CONTINUOUS LEDGER BOARD FOR COUNTER TOP SURFACE TOP SUPPORT w WOOD VENEER Q THK. x 25" D. WORK SURFACE: 3 RECEPTION 15" WIDE DRAWER BASE - WITH LOCKING DRAWERS ACCENT THK. SLOPING BRACKET EPTH FOR COUNTER TOP �2" BAND SUPPORT AS NEEDED N 15" W. BASE CABINET: 1 N 4" H. BASE ELEVATION AT s RECEPTION DESK A–� SCALE: 3/e"=1' -O" ADJ. SHELVES TYPICAL) P SCRIBE 6 WALL (TYPICAL) 4" WIRE PULLS- TYP. 2" H. VALANCE 4"H. BACKSPLASH 111/2" THK, 25" D. COUNTERTOP SURFACE CONT. 2X4 LEDGER BOARD WITH PLAM FINISH FOR COUNTERTOP SUPPORT LOCKABLE (3) DRAWER BASE CABINETS- TYP. 4" H. BASE ELEVATION AT PRIVATE 8 OFFICE '4 -3 SCALE: %"=1'-0" RUN COUNTERTOP BEHIND WALL INTO PERPENDICULAR WALL BEYOND - WRAP BACKSPLASH- SEE PLAN 4"H. BACKSPLASH 25" D. COUNTERTOP f]_'LA8NA'ETAINLES8 STEEL 0 PULL AS MRYD BY IKEA : ("601381.59)- TYP. `4 ADJ. SHELF MINI -FRIDGE WITH GLA55 DOOR I -22 ° 1'-11'= 4" H. BASE 3' NOTES: -64"t I. PRIOR TO FABRICATION, VERIFY EXISTING COLUMN LOCATION IN FIELD. MILLWORK SIZES AND DIMENSION TO BE DICTATED BY FINAL LOCATION. 2. PRIOR TO FABRICATION, VERIFY REFRIGERATOR SIZE TO BE SUPPLIED BY OWNER AS THIS MAY AFFECT OVERALL HEIGHT AND CABINET WIDTH. 3. UNDER COUNTER REFRIGERATOR MUST MEET ADA REQUIREMENTS / SPECIFICATIONS. ELEVATION AT '3 BEVERAGE STATION SCALE: 3b" - 1 -ID" A-3 AM I''2" THK TRANSACTION SURFACE WOOD 2x4 TOP PLATE PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS PARTITION WALL BEYOND 1''/2" THK. x 12" W. TRANSACTION SHELF ® 3'-8" AFP. 11/2 - THK. x 25" D. COUNTERTOP SURFACE a 2'-6" AFF. CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND -- 2" ACCENT BAND 2" ACCENT BAND a EQUAL EQUAL EQUAL WOOD VENEER J w 1'/2" THK COUNTER 8 N —2" ACCENT BAND N TOP SURFACE "' w WOOD VENEER Q N Z WOOD VENEER 3 RECEPTION - OUNTERTOr7; ACCENT A–J SCALE: 3ie =1,_O, EPTH � �2" BAND N 1 N W PmD Pm —WOOD VENEER d 3 SPACED m I6" OC s – I'�2" THK, 25" D 0 POD COUNTERTOP SINK SECTION SURFACE: SS -I I2 = `" 4" H. BASE ^ –� SCALE: BV' I'-0" ADJ. SHELVES TYPICAL) P SCRIBE 6 WALL (TYPICAL) 4" WIRE PULLS- TYP. 2" H. VALANCE 4"H. BACKSPLASH 111/2" THK, 25" D. COUNTERTOP SURFACE CONT. 2X4 LEDGER BOARD WITH PLAM FINISH FOR COUNTERTOP SUPPORT LOCKABLE (3) DRAWER BASE CABINETS- TYP. 4" H. BASE ELEVATION AT PRIVATE 8 OFFICE '4 -3 SCALE: %"=1'-0" RUN COUNTERTOP BEHIND WALL INTO PERPENDICULAR WALL BEYOND - WRAP BACKSPLASH- SEE PLAN 4"H. BACKSPLASH 25" D. COUNTERTOP f]_'LA8NA'ETAINLES8 STEEL 0 PULL AS MRYD BY IKEA : ("601381.59)- TYP. `4 ADJ. SHELF MINI -FRIDGE WITH GLA55 DOOR I -22 ° 1'-11'= 4" H. BASE 3' NOTES: -64"t I. PRIOR TO FABRICATION, VERIFY EXISTING COLUMN LOCATION IN FIELD. MILLWORK SIZES AND DIMENSION TO BE DICTATED BY FINAL LOCATION. 2. PRIOR TO FABRICATION, VERIFY REFRIGERATOR SIZE TO BE SUPPLIED BY OWNER AS THIS MAY AFFECT OVERALL HEIGHT AND CABINET WIDTH. 3. UNDER COUNTER REFRIGERATOR MUST MEET ADA REQUIREMENTS / SPECIFICATIONS. ELEVATION AT '3 BEVERAGE STATION SCALE: 3b" - 1 -ID" A-3 AM I''2" THK TRANSACTION SURFACE WOOD 2x4 TOP PLATE PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS PARTITION WALL BEYOND 1''/2" THK. x 12" W. TRANSACTION SHELF ® 3'-8" AFP. 11/2 - THK. x 25" D. COUNTERTOP SURFACE a 2'-6" AFF. CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND sxa" GYPSUM BOARD ON INSIDE FACE- PAINTED P.T. 2x4 SILL PLATE SECTION AT BUSINESS DESK Y1/-3 SCALE: Ii2 1,_1,-0,l -- 2" ACCENT BAND 2" ACCENT BAND a WOOD 2x4 LEDGER BOARD WOOD VENEER J w 1'/2" THK COUNTER —2" ACCENT BAND N TOP SURFACE "' w WOOD VENEER Q N Z WOOD VENEER 3 RECEPTION - OUNTERTOr7; ACCENT A–J SCALE: 3ie =1,_O, EPTH � �2" BAND N W 2 x 4 WOOD STUDS —WOOD VENEER d 3 SPACED m I6" OC —4" H. BASE F1 sxa" GYPSUM BOARD ON INSIDE FACE- PAINTED P.T. 2x4 SILL PLATE SECTION AT BUSINESS DESK Y1/-3 SCALE: Ii2 1,_1,-0,l EQUAL I. EQUAL SCALE: 3b" = I'-0" 2"0 STEEL POE FOR COUNTER TOP SUPPORT NOTE: – " NOTE: v -- 2" ACCENT BAND MAINTAIN 1''/2" OVERHANG AT SEE FINISH DRAWINGS FOR 0 ELEVATION 8 –WOOD VENEER AT RTO "' –2" ACCENT BAND N .I WOOD VENEER 3 RECEPTION - DESK A–J SCALE: 3ie =1,_O, EQUAL I. EQUAL SCALE: 3b" = I'-0" 2"0 STEEL POE FOR COUNTER TOP SUPPORT NOTE: – " NOTE: v -- 2" ACCENT BAND MAINTAIN 1''/2" OVERHANG AT SEE FINISH DRAWINGS FOR ALL COUNTER TOP SURFACES WOOD VENEER INFORMATION ELEVATION 8 –WOOD VENEER AT RTO "' –2" ACCENT BAND N WOOD VENEER 3 RECEPTION - DESK A–J SCALE: 3ie =1,_O, WOOD 2x4 TOP PLATE WOOD 2x4 LEDGER BOARD 0/2" THK COUNTER TOP SURFACE 2 x 4 WOOD STUDS SPACED 9 16" O.C. e/e" GYPSUM BOARD ON INSIDE FACE- PAINTED e/e" GYPSUM BOARD — P.T. 2x4 SILL PLATE 4" H. BASE SECTION AT BUSINESS DESK A–� SCALE: /2"=1'-O" PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT BEYOND II12" THK x 25" D. COUNTERTOP SURFACE 0 2'-6" AFP. BEYOND Ilii" THK x 25" D. COUNTERTOP SURFACE s 2'-6" AFP, 1112" THK x 12" W. TRANSACTION SHELF 6 3'-8" AFF. WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND I Rw R= ELEVATION SCALE: 31e"=1' -0" –1" SCRIBE O WALL- TYPICAL –ADJ. SHELVES -- 2" ACCENT BAND w 2'-10" 2'-0" 2'-6" NOTE: COORD. WITH SINK I" SCRIBE sWALL- 2x4 BLOCKING FOR SUPPLIED BY P.C. TYPICAL COUNTER ATTACHMENT PROVIDE ADJ. SHELVES AS NEEDED BLOCKING IN (TYPICAL) Iii " THK MARINE 2'-1" WALL AS 2 - NEEDED GRADE PART. BD. W/ 8 –WOOD VENEER - 9 RTO "' –2" ACCENT BAND N WOOD VENEER PLASTIC LAMINATE FINISH- TYP. FOR - O _ r1 4" H. BASE SECTION AT BUSINESS DESK A–� SCALE: /2"=1'-O" PAINTED GYPSUM BOARD SOFFIT- SEE CEILING PLAN FOR RADIUS CONTINUOUS LEDGER BOARD FOR COUNTERTOP SUPPORT BEYOND II12" THK x 25" D. COUNTERTOP SURFACE 0 2'-6" AFP. BEYOND Ilii" THK x 25" D. COUNTERTOP SURFACE s 2'-6" AFP, 1112" THK x 12" W. TRANSACTION SHELF 6 3'-8" AFF. WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND WOOD VENEER 2" WOOD VENEER ACCENT BAND 4" H. BASE TO MATCH WOOD VENEER ACCENT BAND I Rw R= ELEVATION SCALE: 31e"=1' -0" –1" SCRIBE O WALL- TYPICAL –ADJ. SHELVES W 2'-10" 2'-0" 2'-6" NOTE: COORD. WITH SINK I" SCRIBE sWALL- 2x4 BLOCKING FOR SUPPLIED BY P.C. TYPICAL COUNTER ATTACHMENT PROVIDE ADJ. SHELVES AS NEEDED BLOCKING IN (TYPICAL) Iii " THK MARINE 2'-1" WALL AS 2 - NEEDED GRADE PART. BD. W/ 8 9 - N (TYPICAL) "' PLASTIC LAMINATE FINISH- TYP. FOR –4" WIRE PULLS- TYP. – 2" H. VALANCE –4" H. BACKSPLASH - _ r1 � 4" WIRE PULLS- TTP. ENTIRE COUNTER 2" H. VALANCE PL -4 M – 4" H. BACKSPLASH ACCESS PANEL - NOTE: 0 PANEL FINISH: 11/2" THK., 25" D. PL -I N �p W� – I'�2" THK, 25" D 0 COUNTERTOP SINK SECTION SURFACE: SS -I I2 COUNTERTOP SURFACE: 55-I `" 4" H. BASE ^ –� SCALE: BV' I'-0" 1 Q W – 4' H. BASE ELEVATION AT >> STAFF LOUNGE 114 SCALE: 3ie" = 1'-0" A-3 ALUMINUM FRAME -LESS GLASS ATTACHMENT AS SUPPLIED BY 'C.R. LAURENCE COMPANY CO., INC.' (OR EQUAL) �/4" CLEAR TEMPERED GLASS PANELS LEAVE GAP BETWEEN WINDOW AND GLASS PANELS- V.IF. ALUMINUM FRAME -LESS GLASS ATTACHMENT AS SUPPLIED BY 'CR. LAURENCE COMPANY CO., INC.' (OR EQUAL) 1x8 WOOD CAP- MIN. 3/4" OVERHANG ALL SIDES 214" WOOD APRON PAINTED GYPSUM BOARD 4" BASE 1112" THK x 25" D. COUNTERTOP SURFACE 2'-6" AFP. 4" H. BACKSPLASH 3"0 STEEL POST FOR COUNTERTOP SUPPORT NOTE: ELEVATION SIMILAR OTHER SIDE. AT PRIVATE 1 0 wri W e O _ r1 � N W� LU I� 1 Q W ti 0L 0 W 4 N p Q ~ � Z Q U cp LU � l i W v' ry N l� d) V w Z O X LL —w wz 0 LLI 4 � Q q U d w _ 0 SHEET NO, TOILET ROOM IIT ENLARGED TOILET ROOM PLANS A—F SCALE: I SIGN SPECIFICATIONS CODE- ADA COMPLIANT SIGNAGE MANUF. BY- SETON STYLE - TOILET ROOM -ECONOMY BRAILLE SIGNS- RESTROOMS DOOR EXIT- STANDARD BRAILLE SIGNS- EXIT SIZE- TOILET ROOM- 6x9, EXIT- 8x2 NOTE, SUBMIT ROOM IDENTIFICATION SHOP DRAWINGS FOR REVIEW AND COMMENT PRIOR TO ORDERING - �. )OR ryl 81i © IEjI`° TYP. °1-111 LAV. FRONT ELEV. SCALE: I DASHED LINE INDICATES "H" CLEARANCE PROVIDE ADA COMPLIA PIPE INSULATION AT ALL EXPOSED PIPING UNDER HANDICAPPED SINKS. TYP.1111 S r11 TOILET FRONT ELEVATION SCALE: 1i4"=I'-O" ,H" IF TYP. 111-111 LAY. SIDE ELEV. SCALE: I/4"=1' -O" TYP. 111411 TOILET SIDE ELEVATION SCALE: NOTE: ELEVATIONS ARE TO SHOW MOUNTING HEIGHTS OF TOILET FIXTURES ONLY. FOR LOCATIONS OF ACCESSORIES SEE ENLARGED PLANS ABOVE AND FURNISH TO OWNER FOR APPROVAL. GENERAL CONTRACTOR TO SUBMIT UP TO (4) FOUR MASTER KEYS TO OWNER -KNOCKDOWN FRAMES WILL NOT PERMITTED ON THIS PROJECT. DOOR NOTES I. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR / FRAME SIZES, DIMENSIONS, DOOR SWINGS, DOOR / FRAME MATERIALS, DOOR / FRAME TYPES, FRAME WIDTH AND DEPTH, THROAT DEPTH AND FRAME HEAD HEIGHT. 2. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR QUANTITIES PRIOR TO ORDERING. 3. INTERIOR GLAZING IN DOORS TO BE 1/4" THICK CLEAR, TEMPERED GLASS. 4. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DOOR HARDWARE REQUIREMENTS FOR ALL FRAMES INDICATED. ALL SUBMITTALS ISSUED TO THE ARCHITECT SHALL REFLECT THIS FIELD vERIFIED COORDINATION, B. ALL FRAMES SHALL BE SHIMMED / CAULKED IN ACCORDANCE WITH ACCEPTED PRACTICES 6. REFER TO PLANS FOR PROPER DOOR SWINGS T. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR UNDERCUT AND LOUVER LOCATIONS WITH MECHANICAL DRAWINGS 8. VERIFY ALL DOOR STYLES WITH OWNER DOOR TYI=ES: 3'-4" • R.O.- V.IF. ON LATCH SIDE d O O OF DOOR MANUF. / MODEL NO. z pj TACTILE CHARACTERS BRAILLE SHALL v W m 9HALL BE 48" MIN. AFF. TO BE 48" MIN. AFF. I HR. RATED DOOR N BASELINE OF LOWEST TO 60" MAX, CHARACTER 4 60" MAX. APF. TO SEf 5CHED E AFF. TO SAME. !ANSI BASELINE OF 'YPII'-DI O INDICATED AND FURNISH TO OWNER FOR APPROVAL. GENERAL CONTRACTOR TO SUBMIT UP TO (4) FOUR MASTER KEYS TO OWNER -KNOCKDOWN FRAMES WILL NOT PERMITTED ON THIS PROJECT. DOOR NOTES I. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR / FRAME SIZES, DIMENSIONS, DOOR SWINGS, DOOR / FRAME MATERIALS, DOOR / FRAME TYPES, FRAME WIDTH AND DEPTH, THROAT DEPTH AND FRAME HEAD HEIGHT. 2. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR QUANTITIES PRIOR TO ORDERING. 3. INTERIOR GLAZING IN DOORS TO BE 1/4" THICK CLEAR, TEMPERED GLASS. 4. GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE ALL DOOR HARDWARE REQUIREMENTS FOR ALL FRAMES INDICATED. ALL SUBMITTALS ISSUED TO THE ARCHITECT SHALL REFLECT THIS FIELD vERIFIED COORDINATION, B. ALL FRAMES SHALL BE SHIMMED / CAULKED IN ACCORDANCE WITH ACCEPTED PRACTICES 6. REFER TO PLANS FOR PROPER DOOR SWINGS T. GENERAL CONTRACTOR SHALL VERIFY ALL DOOR UNDERCUT AND LOUVER LOCATIONS WITH MECHANICAL DRAWINGS 8. VERIFY ALL DOOR STYLES WITH OWNER DOOR TYI=ES: R.O.- 3'-0" O 3'-4" • R.O.- V.IF. TAG DESCRIPTION MANUF. / MODEL NO. REMARKS A COAT AND BUMPER HOOK CONFIRM WITH OWNER MOUNT 48" AFF. TO CENTERLINE 0 I HR. RATED DOOR CONFIRM WITH OWNER MOUNT 48" AFF. TO BOTTOM 5402 BRADLEY ASSEMBLY WHERE SEf 5CHED E S SCHED LE CONFIRM WITH OMER MOUNT 40" AFP. MAX TO BOTTOM O INDICATED CONFIRM WITH OWNER MOUNT 42" APF, TO USABLE LEVERS - GRAB BARS 36" LONG (PEENED: P THK, FIRE RATED,HOLLOW MOUNT 34" AFF. TO CENTERLINE SOLID CORE GRAB BARS 42" LONG (PEENED)812-001-42-2 BRADLEY MOUNT 34" AFF, TO CENTERLINE CLEAR TEMPERED GRAB BARS I8" LONG (PEENED) WOOD DOOR / METAL TOILET ACCESSORY SCHEDULE NOTES : GLASS. GLASS SPEC PROVIDE REQUIRED BLOCKING FOR ALL 4, HANDICAPPED FIXTURE MOUNTING HEIGHTS: DOOR WATER CLOSET- IT" MIN. TO 19: MAX, AFF. / ETCHED ON GLA55- TO TOP OF SEAT HOLLOW METAL / IHR RATED �., 9 TENSILE STRESSES SHALL ALSO MEET THE 250 Ib. POINT LOAD WHERE INDICATED DOOR FRAME - 0i2" MAX BOWL DEPTH DOOR ALL ACCESSORIES TO BE INSTALLED PER CURRENT A.D.A. 5. INSTALL INSULATION ON PLUMBING PIPING REQUIREMENTS. UNDER LAv'S AS REQUIRED BY A.D.A. 3, ASSEMBLY r. SOLID CORE WOOD ACCESSORY SURFACES IN CONTACT WITH WALL HOLLOW DOOR METAL DOOR \ \ FRAME N \ A NOTES: O B O O I. NO WIRE MESH IN GLAZING WILL BE PERMITTED 2. SEE SCHEDULE FOR FIRE RATING LOCATIONS R.O.- 3'-0" O FRAME TYPES: SCALE: Ilii"=1'-0" II GYP. BD, OR 5/6P.R GYP. BD. 3 m II 3 2x4 WOOD STUDS CONT. CAULK — (TYP. EA. SIDE) L INTEL TYf=ES SCALE: 11/2"=I' -O" s/e" GYP, BD. OR s/g" RR. GYP. BD. (2) 2x4 WOOD STUD — W/ PLYWOOD SPACER 1i4" THK, CLEAR TEMPERED GLASS. GLASS SPEC ETCHE ON GLASS- WHERE INDICATED SOLID CORE WOOD DOOR H.M. FRAME 4 3/4" ANCHORS (3 MINIMUM PER JAMB) ANCHORS (3 MINIMUM PER JAMB) EXISTING CONSTRUCTION V.IF. s HOLLOW METAL FRAME HOLLOW METAL FRAME PRIMED AND PAINTED (TYP.)PRIMED AND PAINTED (TYP.) 8 SEALANT BOTH SIDES EXISTING CON - HOLLOW METAL FRAME PRIMED AND PAINTED 53/4. (TYP.) HOLLOW METAL FRAME PRIMED AND PAINTED L-2 (TYP.) OF Brian A. Clark 404258 0 1WU `-4 Q 0 ti 00 111111 O l -1-r Hardware: I�IWO Product Specified Manufacturer Equivalent Manufacturer O ¢� 1(1n W 1 Hinges McKinney Sommer, Hager F - Cylindrical Locks Corbin Russwin CL3300 series Yale 540011-N, Sargent 10 line W r --F O CylindersCorbin Russwin Yale, Sargent z Exit Devices Corbin Russwin ED5000 series Yale 7000, Sargent 80 Door Closers Corbin Russwin DC6000 series Norton 8501, Yale 3501 O U0 Protection Plates Rockwood Hiawatha, Trimco Door Stops Rockwood Hiawatha, Trimco Overhead Stops Rixson Sargent, Glynn Johnson Threshold / Gasket Pemko Reese, Zero Q I� ~ NOTE: Use Specified Manufacturers or Listed Acceptable Manufacturers Only. W (Y Z Other Products Implied on shop drawings will be rejected without prior approval. O U U LU (j) Manufacturer's Abbreviations Q 1. MK - McKinney 2. RO - Rockwood 3. RU - Corbin Russwin (� 4. RF - Rixson 5. PE - Pemko 6. AD -Adams Rite Hardware Schedule cp L Set: 1.0 U 6f CO Doors: 101 0) 3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D MK nr�' 1 1 Exit Device (rim, classroom) ED5200 PR955 6P MK 630 RU lL r 1 1 Closer (surface) DC621OAl2 689 RU 1 Kick Plate K1050 10" high 4BE CSK US32D RO N 1 Threshold 273x224AFGT x LAR MSES25SS PE O z 1Sweep 3452CNB x LAR PE r— ,n�/, to Set: 2.0 Doors: 104, 105, 112, 114 LU Z �' 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK L" 0 X 1 Cylindrical Lock (passage) CL3310 PZD 626 RU z 1 Door Stop 409 US32D RO U- 3 Silencer 608 RO z Set: 1 Q Doors: 113 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (storeroom) CL3357 PZD MK 626 RU Z dl 1 Surface Overhead Stop 10-X36 630 RF W 3 Silencer 608 RO Set: 4.0 Doors: 117, 12013 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK z U <rW 1 Cylindrical Lock (office) CL3351 PZD MK 626 RU LU 1 Door Stop 409 US32D RO lL 3Silencer 608 RO = rr Q l TL Set: 1 Doors: 111, 116,119 \11 Q 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (privacy) CL3320 PZD 626 RU 1 Door Stop 409 US32D RO 3Silencer 608 RO 3 NO, I TOILET ACCESSOR'I SCHEDULE TAG DESCRIPTION MANUF. / MODEL NO. REMARKS A COAT AND BUMPER HOOK CONFIRM WITH OWNER MOUNT 48" AFF. TO CENTERLINE 0 PAPER TOWEL DISPENSER TOILET TISSUE DISPENSER CONFIRM WITH OWNER MOUNT 48" AFF. TO BOTTOM 5402 BRADLEY MOUNT 28" AFF. TO CENTERLINE P MIRROR CONFIRM WITH OMER MOUNT 40" AFP. MAX TO BOTTOM O SOAP DISPENSER CONFIRM WITH OWNER MOUNT 42" APF, TO USABLE LEVERS 0 GRAB BARS 36" LONG (PEENED: 812-001-36-2 BRADLEY MOUNT 34" AFF. TO CENTERLINE O GRAB BARS 42" LONG (PEENED)812-001-42-2 BRADLEY MOUNT 34" AFF, TO CENTERLINE H GRAB BARS I8" LONG (PEENED) 812-001-I6-2 BRADLEY MOUNT 3S" APF. TO BOTTOM TOILET ACCESSORY SCHEDULE NOTES : I. PROVIDE REQUIRED BLOCKING FOR ALL 4, HANDICAPPED FIXTURE MOUNTING HEIGHTS: ACCESSORIES SUPPLIED BY THE OWNER OR CONTRACTOR WATER CLOSET- IT" MIN. TO 19: MAX, AFF. REINFORCING IN WALLS FOR GRAB BARS SHALL BE CAPABLE TO TOP OF SEAT SUPPORTING AT LEAST A 250 Ib. POINT LOAD, THE SHEAR AND LAVATORY- 21" MIN. TO BOTTOM OF RIM TENSILE STRESSES SHALL ALSO MEET THE 250 Ib. POINT LOAD - 34" MAX TO TOP OF RIM REQUIREMENT. - 0i2" MAX BOWL DEPTH 2. ALL ACCESSORIES TO BE INSTALLED PER CURRENT A.D.A. 5. INSTALL INSULATION ON PLUMBING PIPING REQUIREMENTS. UNDER LAv'S AS REQUIRED BY A.D.A. 3, "H" INDICATES HANDICAPPED ACCESSIBLE FIXTURES. 6, SILICONE SEAL AROUND ALL TOILET ROOM ACCESSORY SURFACES IN CONTACT WITH WALL SURFACE TO AVOID ANY MOISTURE GETTING BEHIND THE ACCESSORY AND INTO THE WALL FRAME TYPES: SCALE: Ilii"=1'-0" II GYP. BD, OR 5/6P.R GYP. BD. 3 m II 3 2x4 WOOD STUDS CONT. CAULK — (TYP. EA. SIDE) L INTEL TYf=ES SCALE: 11/2"=I' -O" s/e" GYP, BD. OR s/g" RR. GYP. BD. (2) 2x4 WOOD STUD — W/ PLYWOOD SPACER 1i4" THK, CLEAR TEMPERED GLASS. GLASS SPEC ETCHE ON GLASS- WHERE INDICATED SOLID CORE WOOD DOOR H.M. FRAME 4 3/4" ANCHORS (3 MINIMUM PER JAMB) ANCHORS (3 MINIMUM PER JAMB) EXISTING CONSTRUCTION V.IF. s HOLLOW METAL FRAME HOLLOW METAL FRAME PRIMED AND PAINTED (TYP.)PRIMED AND PAINTED (TYP.) 8 SEALANT BOTH SIDES EXISTING CON - HOLLOW METAL FRAME PRIMED AND PAINTED 53/4. (TYP.) HOLLOW METAL FRAME PRIMED AND PAINTED L-2 (TYP.) OF Brian A. Clark 404258 0 1WU `-4 Q 0 ti 00 111111 O l -1-r Hardware: I�IWO Product Specified Manufacturer Equivalent Manufacturer O ¢� 1(1n W 1 Hinges McKinney Sommer, Hager F - Cylindrical Locks Corbin Russwin CL3300 series Yale 540011-N, Sargent 10 line W r --F O CylindersCorbin Russwin Yale, Sargent z Exit Devices Corbin Russwin ED5000 series Yale 7000, Sargent 80 Door Closers Corbin Russwin DC6000 series Norton 8501, Yale 3501 O U0 Protection Plates Rockwood Hiawatha, Trimco Door Stops Rockwood Hiawatha, Trimco Overhead Stops Rixson Sargent, Glynn Johnson Threshold / Gasket Pemko Reese, Zero Q I� ~ NOTE: Use Specified Manufacturers or Listed Acceptable Manufacturers Only. W (Y Z Other Products Implied on shop drawings will be rejected without prior approval. O U U LU (j) Manufacturer's Abbreviations Q 1. MK - McKinney 2. RO - Rockwood 3. RU - Corbin Russwin (� 4. RF - Rixson 5. PE - Pemko 6. AD -Adams Rite Hardware Schedule cp L Set: 1.0 U 6f CO Doors: 101 0) 3 Hinge (heavy weight) T4A3386 NRP 4-1/2" x 4-1/2" US32D MK nr�' 1 1 Exit Device (rim, classroom) ED5200 PR955 6P MK 630 RU lL r 1 1 Closer (surface) DC621OAl2 689 RU 1 Kick Plate K1050 10" high 4BE CSK US32D RO N 1 Threshold 273x224AFGT x LAR MSES25SS PE O z 1Sweep 3452CNB x LAR PE r— ,n�/, to Set: 2.0 Doors: 104, 105, 112, 114 LU Z �' 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK L" 0 X 1 Cylindrical Lock (passage) CL3310 PZD 626 RU z 1 Door Stop 409 US32D RO U- 3 Silencer 608 RO z Set: 1 Q Doors: 113 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (storeroom) CL3357 PZD MK 626 RU Z dl 1 Surface Overhead Stop 10-X36 630 RF W 3 Silencer 608 RO Set: 4.0 Doors: 117, 12013 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK z U <rW 1 Cylindrical Lock (office) CL3351 PZD MK 626 RU LU 1 Door Stop 409 US32D RO lL 3Silencer 608 RO = rr Q l TL Set: 1 Doors: 111, 116,119 \11 Q 3Hinge TA2714 4-1/2" x 4-1/2" US26D MK 1 Cylindrical Lock (privacy) CL3320 PZD 626 RU 1 Door Stop 409 US32D RO 3Silencer 608 RO 3 NO, I Z-03 EXTERIOR FEATURESASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 8/31/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16 PINK SET 8/31/16 1744 PORTO-I Width:4.25" Height:9.5" Extension:6" Glass:Clear Acrylic CFL:1 x 13WT2 (GU24) Twist Lock (self ballast bulb Included) (OPTIONAL) Lamp:1 x 60W - 120V - A19 (not included) Finish:Architectural Silver Notes:Suitable for Wet locations. contemporary elegance PLC Lighting Inc. 9667 Owensmouth Avenue, Unit 201, Chatsworth, CA 91311 Phone: (888) 357-4040 (Outside California) (818) 349-1600 Fax: (818) 280-0909 (818) 407-0100 www.plclighting.com W60W59D42T03T04T06T05T01T02A 1 4 6 2 3 5 10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10" 3'-2 1/2"10"19'-8"3'-2 1/2"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"NON-UNIT ELEVATOR. SYMMETRY LU/LA SHADING INDICATES ONE HOUR FIRE SEPARATION, SEE A 5.1 REMOVE AND FILL IN WITH BRICK TO MATCH EXTERIOR RECYCLE: 4 TOTERS TRASH: 2 TOTERS NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER ELEVATOR ELECT. PNL. TRASH: 4 TOTERS ELECT. METER 6"2'-5 3/4"NEW CONCRETE CURB NEW STEEL1X2 BAR STOCK POST AT HANDRAIL NEW STEEL 1X2 BAR STOCK HANDRAIL 0 3/4"11 1/4"1'0 3/4"3'1" X 2" WELDED STEEL BAR STOCK POSTS / HANDRAIL LESS THAN 30" TO GRADE AT ALL LANDSCAPE STAIR LOCATIONS RISE AND RUN VARY: SEE CIVIL DRAWINGS STEP LIGHTS TYP. #1200WR-VISION3-0SQH1-00SA Vision 3 Wall Recessed Shown in: Satin Aluminum Description:Description:Description:Description: Vision 3 square wall / floor recessed fixture is perfect for furniture, and wall applications. The fixture features a scoop reflector and a silver finish. The Vision 3 kit includes the fixture, housing, plaster screen, electronic transformer and one 20 watt, 12 volt, JC, G4 halogen lamp. General light distribution. ETL listed. List Price:List Price:List Price:List Price:$242.00 Our Price:Our Price:Our Price:Our Price:$193.60 Shade Color:Shade Color:Shade Color:Shade Color:N/A Body Finish:Body Finish:Body Finish:Body Finish:Satin Aluminum Lamp:Lamp:Lamp:Lamp:1 x JC/G4 (bipin)/20W/12V Wattage:Wattage:Wattage:Wattage:20W Dimmer:Dimmer:Dimmer:Dimmer:Low Voltage Electronic Dimensions:Dimensions:Dimensions:Dimensions:3.5"H x 3.5"W x 3"D Product Number:('* Company:Company:Company:Company:Fixture Type:Fixture Type:Fixture Type:Fixture Type:Date:Date:Date:Date:Jul 09, 2014Jul 09, 2014Jul 09, 2014Jul 09, 2014 Project:Project:Project:Project:Approved By:Approved By:Approved By:Approved By:www.Lightology.comwww.Lightology.comwww.Lightology.comwww.Lightology.comAddress: Address: Address: Address: Phone: Phone: Phone: Phone: Fax: Fax: Fax: Fax: 1718 W. Fullerton Ave. Chicago IL 60614 866-954-4489(773) 883-6131SCALE: 1/4" = 1'-0" TRASH SCALE: 1" = 1'-0" TYP. RAIL AT RAMP SCALE: 1" = 1'-0" TYPICAL LANDSCAPE STEP DETAIL LIGHT FIXTURES FIXTURE L FIXTURE V FIXTURE P AT PRESENT THE WASTE SERVICE REMOVES TWO 96-GAL "TOTERS" THREE TIMES PER WEEK. ONE IS TRASH, ONE IS RECYCLE NET-1 NET LIVABLE/ LEASABLEASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 10/3/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16 PINK SET 8/31/16 NON-UNIT EXTERIOR STAIR 52 S.F. (NET EXEMPT) COMMERCIAL STORAGE 209 S.F. + 252 S.F. = 461 S.F. GENERAL BUILDING MECHANICAL (INCL. ELEV. MECH)77+19=96 S.F. (NET EXEMPT) NON-UNIT INTERIOR HALL 134 S.F. NON-UNIT EXTERIOR STAIR 41 S.F. (NET EXEMPT) NON-UNIT EXTERIOR ELEVATOR 45 S.F. ENTRY LOBBY 344 S.F. RESIDENTIAL STAIR 80 S.F. COMMERCIAL NET LEASABLE (1285+1006+1205) 3496 S.F. MAIN LEVEL NET LIVABLE / LEASABLE 569+ 777+ 2150 UPPER LEVEL NET LIVABLE / LEASABLE NON-UNIT EXTERIOR BALCONY/STAIR 131 S.F. (NET EXEMPT) NON-UNIT EXTERIOR ELEVATOR 45 S.F. (NET EXEMPT) COMMERCIAL NET LEASABLE 532 S.F. FREE-MARKET RESIDENTIAL LIVABLE 2420 S.F. UPPER LEVEL NET LIVABLE / LEASABLE CDWDW FFD02 D15 D20 D22D19D14D06D10 D16 D09D12W24 GLASS ENCL. WIRE SYSTEM WINE RACK OVER WINE CHILLER PD LIGHT WASHES TILE WALL AND PERIMETER OF WINE ENCLOSURE EXISTING WOODBURNING FIREPLACE IN EXISTING CHASE 1234567891011121314W22W23W24W26 W27 W28 W29 W30 W31 W15D05W06W07W05W12D01W17 W16W20W18 ED23D03D112,420 sq ft 1 2 3 412345678A A E E F F B B C C D D6'-4"8'-1/2" 2'-1 1/2" 532 sq ft RECESS SHADE POCKET AT LIFT-N-SLIDE switch D17D24 RESIDENTIAL COMMERCIAL HER CLOSET EXIT ELEVATOR KITCHENMUD ROOM LAUNDRY PANTRY HIS BEDROOM HIS BATH HER BATH MECH CHASEMontigo RP424PFN GAS APPLIANCE ELECT. PNL. ELECT. PNL. MECHCHASE PITCH 1/8"/FT. IRONING BOARD PROVIDE OUTLET RETRACT. C'LINE NICHE A/V POWERVENT sconces SHELVESE.T. E.T. E.T. ABOVE E.T. ABOVE W08W09W10W11 W04W03W02W01D04D08476 sq ft 131 sq ft RAIL EXTENDS TO WALL RAIL RETURN, SEE A 7.2 TRACK FOR LADDER TRACK FOR LADDER switch pendantpendant DINING ROOM LIVING ROOM HIS CLOS. OFFICE.ENTRY POWDER HALL HBD35D411234567891011121234567891011121314 W60W59D42W40 W41D31 W42W44W43D32D34D33W62T03T04T06T05T01W67 W64 W65 W66W61 W32W33W34W35 T021 2 3 412345678A A E E F F B B C C D D10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10"17'-4 1/2"10"9'-1/4"10'-5 1/4"7'-1 1/4"6 3/4"7'-4 3/4"6 3/4"25'-8 1/2"10" 80'-8" 3'-2 1/2"10"17'-4 1/2"10"9'-1 1/2"4"18'-8"4"14'7 1/2"8'-2"7 1/4"3'-9 1/2"7 3/4"3'-9 1/2"1'-1/4" 5 1/2"6'-10 3/4"10"4'-1 1/2"5 1/2"7'-5 1/4"8"4'-11 3/4" 1'-11"19'-8"17'-4 1/4"10"9'-1 3/4"4"18'-8"4"13'-9"10" 3'-11 1/2"6'-7"4'-5 1/4"9 1/2"12'-1"5 1/2"5'-6"3 1/2"5'-7"5 1/2"26'-1/4"3'-2 1/2" 1' 5"17'11 3/4"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"18'-5 3/4"14'-4"13'-6"15'-4 1/4"18'-5 1/2"9'-5 3/4"13'-2 1/4"5'-2 1/2"15'-1 1/2"5'-3 1/2"13'-2"7'-7 1/4" 17'-2 1/4"2'-2"6'-10 3/4"3 1/2"3'-1"5 1/2"6'-10 3/4" 5 1/2" 11'11'-9 3/4"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"11'-10 1/4"8"4'-6 1/2"8"5'-11 1/4"3'-11 1/2"5 1/2"5 1/2"6'-10 3/4"17'-1"60'-3"23'-8 1/4"569 sq ft 777 sq ft 2150 sq ft 45 sq ft 1-HOUR RATED MECH CHASE (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED MECH CHASE AND WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED MECH CHASE AND WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) REMOVE AND FILL IN WITH BRICK TO MATCH EXTERIOR ACCESSIBLE MEN ACCESSIBLE WOMEN ENTRY PATIO AT GRADE up NON-UNIT LOBBY EXISTING RAMP TO BE REMOVEDWINDOW UNITRECYCLE: 4 TOTERS EXISTING PLANTER TO BE RESIDED- SEE SITE PLAN TRASH: 2 TOTERS GAS METER COMMERCIAL COMMERCIAL COMMERCIAL DRINKING FOUNTAIN TO COMPLY W/ ICC 117.1 SEC 602NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER ELEVATOR STRUCTURAL WALL TO REMAIN STRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAIN WAITING ROOM MECH / STOR MECH CHASENO DROP CEILING NO DROP CEILING DROP CEILING DROP CEILING WALL MECH CHASE ELECT. PNL. ELECT. PNL.ELECT. PNL. TRASH: 4 TOTERS HB HB W46EW45W46DW46CW46BW46AW52 W51 W49 W48 D40 W55 W54 9'-3"5 1/2"7'-6"2"11 3/4"2'-1 1/4"4'-1 1/2"5' 5' 337 sq ft 81 sq ft RAIL EXTENSION BOTH SIDES CUT BACK PLANTER TO ALLOW POURING OF NEW FOOTINGS ELECT. METER P HBD51 D51D54 D56D52 D55D5317'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4" 14'-6"8" 8'5'-6" 4'-10"3 1/2"4'-7" 1'1'9'-1 1/4"3 1/2"77 sq ft 19 sq ft EXISTING DOOR LOCATION EXISTING EGRESS DOOR EXISTING EXTERIOR STAIR TO REMAIN PROPOSED LADDER RAIL DIES INTO DOOR WALL AT MAIN LEVEL. 1' EXTENSION DOES NOT OCCUR AT LOWER LEVEL DOOR NON- UNIT MECH 2% of 7475 s.f. mech as required = 150 s.f. NON-UNIT EXTERIOR STAIR 52 S.F. (NET EXEMPT) COMMERCIAL STORAGE 209 S.F. + 252 S.F. = 461 S.F. GENERAL BUILDING MECHANICAL (INCL. ELEV. MECH)77+19=96 S.F. (NET EXEMPT) NON-UNIT INTERIOR HALL 134 S.F. COMMERCIAL STORAGE 3 NON-UNIT HALL COMMERCIAL STORAGE 1 ELEV. MECH. SELF-CLOSING DOOR TENANT FINISH TENANT FINISH CEILING TO BE 1-HOUR FIRE RATED (TYP) EXIT COMMON ELECT. PNL. COMMERCIAL STORAGE 2 TENANT FINISH 252 sq ft 96 sq ft 134 sq ft 113 sq ft TOTAL NET LEASABLE- COMMERCIAL 3496+528+461= 4485 S.F. TOTAL NET LIVABLE- RESIDENTIAL 2419+80= 2499 S.F. TOTAL NON-UNIT INTERIOR SPACE TOTAL NON-UNIT DECKS / EXTERIOR SPACE (EXEMPT) 29+344+45+134+96 = 648 S.F. 120+41+45+52 = 258 S.F. TOTAL NET LIVABLE+ NET LEASABLE =6984 S.F. PERCENT NET LEASABLE OF TOTAL 4485/6984 S.F. = 64% PERCENT NET LIVABLE OF TOTAL 2499/6936 S.F. = 36% 26.575.020.D.14 Allocation of non- unit space in a mixed use building. NET-1 NET LIVABLE/ LEASABLEASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14 8/9/16PRINTED ON ALL DESIGNS, IDEAS ARRANGEMENTS AND PLANS INDICAT ED BY THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF KIM RAYMOND ARCHITECTS, INC. AND SHALL NEITHER BE USED ON ANY OTHER WORK NOR BE USED BY ANY OTHER PERSON FOR ANY USE WHATSOEVER WIT H OUT W RI TT E N PERM I S SIO N . WRITTEN DIMENSIONS SHALL TAKE P R E C E D E N C E O V E R S C A L E D DIMENSIONS AND SHALL BE VERIFIED AT T H E S I T E . A N Y D I M E N S I O N A L DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. IF THE ABOVE DIMENSION DOES NOT MEASURE ONE I N C H (1 ") E X A C TLY, THI S DRAWING WILL HAVE BEEN EN LA RGE D OR RED UCE D, AFF E C T I NG A LL LABEL E D SCALES. 1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15 CONST. CLARIF. 9/30/15 CHANGE ORDER 1 10/26/15 CONST. CLARIF. 1/7/16 C.O.# 1 CLARIF 3/25/16 CONST. CLARIF. 5/31/16 NON-UNIT EXTERIOR STAIR 52 S.F. (NET EXEMPT) COMMERCIAL STORAGE 209 S.F. + 252 S.F. = 461 S.F. GENERAL BUILDING MECHANICAL (INCL. ELEV. MECH)77+19=96 S.F. (NET EXEMPT) NON-UNIT INTERIOR HALL 134 S.F. NON-UNIT EXTERIOR STAIR 41 S.F. (NET EXEMPT) NON-UNIT EXTERIOR ELEVATOR 45 S.F. ENTRY LOBBY 344 S.F. RESIDENTIAL STAIR 80 S.F. COMMERCIAL NET LEASABLE (1285+1006+1205) 3496 S.F. MAIN LEVEL NET LIVABLE / LEASABLE 569+ 777+ 2150 UPPER LEVEL NET LIVABLE / LEASABLE NON-UNIT EXTERIOR BALCONY/STAIR 131 S.F. (NET EXEMPT) NON-UNIT EXTERIOR ELEVATOR 45 S.F. (NET EXEMPT) COMMERCIAL NET LEASABLE 532 S.F. FREE-MARKET RESIDENTIAL LIVABLE 2420 S.F. UPPER LEVEL NET LIVABLE / LEASABLE CDWDW FFD02 D15 D20 D22D19D14D06D10 D16 D09D12W24 GLASS ENCL. WIRE SYSTEM WINE RACK OVER WINE CHILLER PD LIGHT WASHES TILE WALL AND PERIMETER OF WINE ENCLOSURE EXISTING WOODBURNING FIREPLACE IN EXISTING CHASE 1234567891011121314W22W23W24W26 W27 W28 W29 W30 W31 W15D05W06W07W05W12D01W17 W16W20W18 ED03D112,420 sq ft 1 2 3 412345678A A E E F F B B C C D D6'-4"8'-1/2" 2'-1 1/2" 532 sq ft RECESS SHADE POCKET AT LIFT-N-SLIDE RESIDENTIAL COMMERCIAL HER CLOSET EXIT ELEVATOR KITCHENMUD ROOM LAUNDRY PANTRY HIS BEDROOM HIS BATH HER BATH MECH CHASEMontigo RP424PFN GAS APPLIANCE ELECT. PNL. ELECT. PNL. MECHCHASE PITCH 1/8"/FT. IRONING BOARD PROVIDE OUTLET RETRACT. C'LINE NICHE A/V POWERVENT sconces SHELVESE.T. E.T. E.T. ABOVE E.T. ABOVE W08W09W10W11 W04W03W02W01D04D08476 sq ft 131 sq ft RAIL EXTENDS TO WALL RAIL RETURN, SEE A 7.2 TRACK FOR LADDER TRACK FOR LADDER DINING ROOM LIVING ROOM HIS CLOS. OFFICE.ENTRY POWDER HALL D35D411234567891011121234567891011121314 W60W59D42W40 W41D31 W42W44W43D32D34D33W62T03T04T06T05T01W67 W64 W65 W66W61 W32W33W34W35 T021 2 3 412345678A A E E F F B B C C D D10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10"17'-4 1/2"10"9'-1/4"10'-5 1/4"7'-1 1/4"6 3/4"7'-4 3/4"6 3/4"25'-8 1/2"10" 80'-8" 3'-2 1/2"10"17'-4 1/2"10"9'-1 1/2"4"18'-8"4"14'7 1/2"8'-2"7 1/4"3'-9 1/2"7 3/4"3'-9 1/2"1'-1/4" 5 1/2"6'-10 3/4"10"4'-1 1/2"5 1/2"7'-5 1/4"8"4'-11 3/4" 1'-11"19'-8"17'-4 1/4"10"9'-1 3/4"4"18'-8"4"13'-9"10" 3'-11 1/2"6'-7"4'-5 1/4"9 1/2"12'-1"5 1/2"5'-6"3 1/2"5'-7"5 1/2"26'-1/4"3'-2 1/2" 1' 5"17'11 3/4"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"18'-5 3/4"14'-4"13'-6"15'-4 1/4"18'-5 1/2"9'-5 3/4"13'-2 1/4"5'-2 1/2"15'-1 1/2"5'-3 1/2"13'-2"7'-7 1/4" 17'-2 1/4"2'-2"6'-10 3/4"3 1/2"3'-1"5 1/2"6'-10 3/4" 5 1/2" 11'11'-9 3/4"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"11'-10 1/4"8"4'-6 1/2"8"5'-11 1/4"3'-11 1/2"5 1/2"5 1/2"6'-10 3/4"17'-1"60'-3"23'-8 1/4"569 sq ft 777 sq ft 2150 sq ft 45 sq ft 1-HOUR RATED MECH CHASE (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED MECH CHASE AND WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED MECH CHASE AND WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) FILL INDICATES 1-HOUR RATED WALLS BETWEEN OFFICES (SEE WALL ASSEMBLY "A" ON THIS PAGE) REMOVE AND FILL IN WITH BRICK TO MATCH EXTERIOR ACCESSIBLE MEN ACCESSIBLE WOMEN ENTRY PATIO AT GRADE up NON-UNIT LOBBY EXISTING RAMP TO BE REMOVEDWINDOW UNITRECYCLE: 4 TOTERS EXISTING PLANTER TO BE RESIDED- SEE SITE PLAN TRASH: 2 TOTERS GAS METER COMMERCIAL COMMERCIAL COMMERCIAL DRINKING FOUNTAIN TO COMPLY W/ ICC 117.1 SEC 602NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER ELEVATOR STRUCTURAL WALL TO REMAIN STRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAIN WAITING ROOM MECH / STOR MECH CHASENO DROP CEILING NO DROP CEILING DROP CEILING DROP CEILING WALL MECH CHASE ELECT. PNL. ELECT. PNL.ELECT. PNL. TRASH: 4 TOTERS W46EW45W46DW46CW46BW46AW52 W51 W49 W48 D40 W55 W54 9'-3"5 1/2"7'-6"2"11 3/4"2'-1 1/4"4'-1 1/2"5' 5' 337 sq ft 81 sq ft RAIL EXTENSION BOTH SIDES CUT BACK PLANTER TO ALLOW POURING OF NEW FOOTINGS ELECT. METER P D51 D51D54 D56D52 D55D5317'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4" 14'-6"8" 8'5'-6" 4'-10"3 1/2"4'-7" 1'1'9'-1 1/4"3 1/2"77 sq ft 19 sq ft EXISTING DOOR LOCATION EXISTING EGRESS DOOR EXISTING EXTERIOR STAIR TO REMAIN PROPOSED LADDER RAIL DIES INTO DOOR WALL AT MAIN LEVEL. 1' EXTENSION DOES NOT OCCUR AT LOWER LEVEL DOOR NON- UNIT MECH 2% of 7475 s.f. mech as required = 150 s.f. NON-UNIT EXTERIOR STAIR 52 S.F. (NET EXEMPT) COMMERCIAL STORAGE 209 S.F. + 252 S.F. = 461 S.F. GENERAL BUILDING MECHANICAL (INCL. ELEV. MECH)77+19=96 S.F. (NET EXEMPT) NON-UNIT INTERIOR HALL 134 S.F. COMMERCIAL STORAGE 3 NON-UNIT HALL COMMERCIAL STORAGE 1 ELEV. MECH. SELF-CLOSING DOOR TENANT FINISH TENANT FINISH CEILING TO BE 1-HOUR FIRE RATED (TYP) EXIT COMMON ELECT. PNL. COMMERCIAL STORAGE 2 252 sq ft 209 sq ft 134 sq ft TOTAL NET LEASABLE- COMMERCIAL 3496+528+461= 4485 S.F. TOTAL NET LIVABLE- RESIDENTIAL 2419+80= 2499 S.F. TOTAL NON-UNIT INTERIOR SPACE TOTAL NON-UNIT DECKS / EXTERIOR SPACE (EXEMPT) 29+344+45+134+96 = 648 S.F. 120+41+45+52 = 258 S.F. TOTAL NET LIVABLE+ NET LEASABLE =6984 S.F. PERCENT NET LEASABLE OF TOTAL 4485/6984 S.F. = 64% PERCENT NET LIVABLE OF TOTAL 2499/6936 S.F. = 36% 26.575.020.D.14 Allocation of non- unit space in a mixed use building. a COMcheck Software Version 4.0.2.9 Interior Lighting Compliance Certificate Section 1: Project Information Energy Code: 20091ECC Project Title: Dr. John Miller Project Type: Alteration Construction Site: Owner/Agent: 100 East Main Street Dr. John Miller Aspen, CO 81611 Section 2: Interior Lighting and Power Calculation A Area Category Section 3: Interior Lighting Fixture Schedule Designer/Contractor: Christopher Russell Greenman Pedersen Inc 50 Glenmaum National Blvd Sorenson, PA 18505 c D res, Allowed Allowad Watts Walls Itt2 (Bx C) Total Allowed Walls= 2140 A B C D E FixturelD: Description l Lamp l Wattage Per Lamp l Ballast Lamps/ #of Fixture (Cx D) Fixture Fixtures, Waft. Offics(2140 sq It) A LED Other Fixture Unit 28W: 1 25 28.5 712.5 B: LED Panel 55W: 1 4 56.1 224.4 C: LED Other Fixture Unit 28W: 1 5 28.7 143.5 D: LED PAR 17W: 1 25 17.1 427.5 F. LED Panel 36W: 1 1 35 35 G: LED PAR 13W: 1 4 13 52 Total Proposed Wafts = 1595 Section 4: Requirements Checklist Lighting Wattage: 5a 1. Total proposed watts must be less than or equal to total slowed watts. Allowed Watts Proposed Watts Complies 2140 1595 Passes Controls, Switching, and Wiring: Nj 2. Daylight zones under skylights more than 15 feet tram the perimeter have lighting controls separate from daylight zones adjacent to N vedical fenestration. 1.3. Daylight zones have individual lighting controls independent from that of the general area lighting. Exreph'ons: ❑ Contiguous daylight zones spanning no more than two orientations are allowed to be controlled by a single controlling device. ❑ Daylight spaces enclosed by walls or ceiling height partilions and containing two or fewer light fixtures ma not required to have a separate switch for general area lighting. Project TNIe: Dr. John Miter Report date: 08/09/16 Data filename: XaSCR-2016231.00 Miller Dental Aspen CoEledLighting12016-08-09 Comcheck@016-08-09.cck Pagel of 2 11/29/2016 Metalux Safe and convenient means of disconnecting power 22EN LED 2' X 2' TROFFER LED MODULE Specification Grade Troffer Catalog # Type Date Project Comments Prepared by SPECIFICATION FEATURES Construction Shallow 3-1/4” deep housing is extruded aluminum frame and injected molded composite end plates. End plates are securely attached with screws for strength and rigidity and the elimination of gaps. End plates have accessory grid-lock feature for safety and convenience. Four auxiliary fixture end suspension points are provided. Large access plate for supply connection. Controls The Encounter LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the Encounter can include a factory- installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 1% with the HD option, for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K, 4000K or 5000K with a typical CRI ≤ 85. Projected life is 100,000 hours at 92% lumen output. Electronic drivers are available for 120-277V applications. Emergency Battery Pack Option Optional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code- compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Driver Access Drivers can be accessed via plenum. Finish Durable frame has high reflectance baked matte white enamel finish for luminous uniformity. Optics Precision formed optical assembly with positively retained high optical grade acrylic lenses provide a directed optical distribution using WaveStream technology. Compliance Components are UL recognized. Indoor luminaires are cULus and CSA listed for 25° C ambient environments, RoHS compliant, and comply with IESNA LM-79. LEDs comply with LM-80 standards. DesignLights Consortium™ Qualified and classified for both DLC Standard and DLC Premium, refer to www. designlights.org for details. Warranty Five year warranty. The Encounter™ redefines ambient lighting by being the first fixture to blend modern contemporary styling with the innovative WaveStream™ technology to deliver exceptional performance and superior energy savings. Encounter’s highly efficient LED system with advance optical design delivers an unparalleled combination of optimal light uniformity for enhanced visual comfort and superior efficiency for greater energy savings. Encounter is compatible with all of today's popular ceiling systems and available in a variety of configurations for application versatility. Its perfect balance of form and function make it an ideal choice for commercial office spaces, schools, hospitals, retail and other indoor ambient applications. DESCRIPTION PS519064EN 2016-03-22 08:35:59 CERTIFICATION DATA cULus - 1598 and 2043** Damp Location Listed CSA IC Rated LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified NOM Compliant *See Drywall Frame Kit Accessory in Ordering Information section. **Fixture construction is suitable for use in Air-handling and plenum rated spaces in accordance with Section 300.22 (C) of the National Electrical Code, Section 4.3.11.2.6.5 of NFPA 90A and Section 602.2.1.4 of ICC. 23-3/4" [603mm] 3-1/4"[83mm] G Grid/Lay-in Standard F Drywall Frame Kit Ceiling Trim Type Type Exposed GridG Concealed TG or T Slot Grid G or T Flange * CEILING COMPATIBILITY 23-3/4" [603mm] 23-11 /16" [602mm] MOUNTING DATA 23-3/4" [603mm] 3-1/4" [83mm] X=2-7/16" [62mm] X 22-15/16" [583mm] Y Y=2-1/2"[64mm] LAMP CONFIGURATIONS Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 22EN-LD2-34-UNV- L835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height Lumens: 3370 Input Watts: 28.5W Effi cacy: 11 8.2 lm/W Te st Report: 22EN-LD2-34-UNV- L835-CD1-U.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 1142 1142 1142 1137 11 36 1141 1121 11 20 11 27 1098 1097 1106 1064 1064 1075 1023 1023 1037 974 971 988 918 917 933 854 852 869 784 780 800 708 702 722 624 618 638 534 526 553 440 431 457 339 334 340 241 232 205 145 126 135 54 56 58 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 109 104 99 95 106 101 97 94 97 94 91 93 91 88 90 87 85 83 99 90 83 77 96 88 82 76 85 79 75 81 77 73 78 75 71 69 90 79 71 64 87 77 70 63 74 68 62 72 66 61 69 64 60 58 82 70 61 54 80 68 60 54 66 59 53 64 57 52 61 56 51 49 75 62 53 46 73 61 53 46 59 51 46 57 50 45 55 49 45 42 69 56 47 40 68 55 46 40 53 45 40 51 45 39 50 44 39 37 64 51 42 36 63 50 41 35 48 41 35 47 40 35 45 39 35 33 60 46 38 32 58 45 37 32 44 37 31 43 36 31 42 36 31 29 56 42 34 28 54 42 34 28 41 33 28 39 33 28 38 32 28 26 52 39 31 26 51 39 31 26 38 30 26 37 30 25 36 30 25 24 Zonal Lumen Summary Zone Lumens % Fixture 0-30 0-40 0-60 0-90 0-180 891 26.4 1467 43.5 2630 78.0 3370 100.0 3370 100.0 400 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 800 1200 22EN-LD2-25-UNV- L835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height Lumens: 2571 Input Watts: 20.9W Effi cacy: 122.5 lm/W Test Report: 22EN-LD2-25-UNV- L835-CD1-U.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 873 873 873 869 868 871 856 856 861 837 837 844 811 811 819 780 779 790 741 741 753 700 698 711 650 649 662 598 595 608 539 535 549 474 472 486 405 402 421 335 328 348 259 255 257 185 178 157 111 97 103 41 43 43 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 109 104 99 95 106 101 97 94 97 94 91 93 91 88 90 87 85 83 99 90 83 77 96 88 82 76 85 79 75 81 77 73 78 75 71 69 90 79 71 64 87 77 70 63 74 68 62 72 66 61 69 64 60 58 82 70 61 54 80 68 60 54 66 59 53 64 57 52 61 56 51 49 75 62 53 46 73 61 52 46 59 51 46 57 50 45 55 49 45 42 69 56 47 40 68 55 46 40 53 45 40 51 45 39 50 44 39 37 64 51 42 36 63 50 41 35 48 41 35 47 40 35 45 39 35 33 60 46 38 32 58 45 37 32 44 37 31 43 36 31 42 36 31 29 56 42 34 28 54 42 34 28 41 33 28 39 33 28 38 32 28 26 52 39 31 26 51 39 31 26 38 30 26 37 30 25 36 30 25 24 Zonal Lumen Summary Zone Lumens% Fixture 0-30 0-40 0-60 0-90 0-180 680 26.4 1118 43.5 2005 78.0 2571 100.0 2571 100.0 300 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 600 900 PHOTOMETRICS 22EN LED 2’ X 2’ PS519064EN 2016-03-22 08:35:59 Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Stock or MTO* Catalog Logic (Curved) Delivered Lumens Watts Efficacy (LPW) MTO 22EN-LD2-19-UNV-L830-CD1-U1969 16.5 11 9 MTO 22EN-LD2-19-UNV-L835-CD1-U 2030 16.5 123 MTO 22EN-LD2-19-UNV-L840-CD1-U 2071 16.5 126 MTO 22EN-LD2-19-UNV-L850-CD1-U 2253 16.5 137 MTO 22EN-LD2-25-UNV-L830-CD1-U 2494 20.0 125 STOCK 22EN-LD2-25-UNV-L835-CD1-U 2571 20.0 129 STOCK 22EN-LD2-25-UNV-L840-CD1-U 2622 20.0 131 MTO 22EN-LD2-25-UNV-L850-CD1-U 2854 20.0 143 MTO 22EN-LD2-30-UNV-L830-CD1-U 2898 24.9 11 6 MTO 22EN-LD2-30-UNV-L835-CD1-U 2988 24.9 120 MTO 22EN-LD2-30-UNV-L840-CD1-U 3048 24.9 122 MTO 22EN-LD2-30-UNV-L850-CD1-U 3317 24.9 133 MTO 22EN-LD2-34-UNV-L830-CD1-U 3269 28.5 11 5 STOCK 22EN-LD2-34-UNV-L835-CD1-U 3370 28.5 11 8 STOCK 22EN-LD2-34-UNV-L840-CD1-U 3437 28.5 121 MTO 22EN-LD2-34-UNV-L850-CD1-U3741 28.5 131 MTO 22EN-LD2-39-UNV-L830-CD1-U3747 33.3 11 3 MTO 22EN-LD2-39-UNV-L835-CD1-U 3863 33.3 11 6 MTO 22EN-LD2-39-UNV-L840-CD1-U 3940 33.3 11 8 MTO 22EN-LD2-39-UNV-L850-CD1-U 4288 33.3 129 MTO 22EN-LD2-43-UNV-L830-CD1-U 4218 38.3 110 MTO 22EN-LD2-43-UNV-L835-CD1-U 4348 38.3 11 4 MTO 22EN-LD2-43-UNV-L840-CD1-U 4435 38.3 11 6 MTO 22EN-LD2-43-UNV-L850-CD1-U 4826 38.3 126 *Made to order (MTO) requires a typical two week lead time. ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER 22EN LED 2’ X 2’ PS519064EN 2016-03-22 08:35:59 Ambient Temperature TM-21 Lumen Maintenance (100,0000 hours) Theoretical L70 (Hours) 25°C > 92%> 448,000 Non-IC data LUMEN MAINTENANCE Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting SAMPLE NUMBER: 22EN-LD2-34-UNV-L835-CD1-SVPD1-U Voltage(1) 347V=347 Volt(6) UNV=Universal Voltage 120-277 Options Emergency EL7W=7-watt, 120V-277V emergency battery pack installed (4) EL14W=14-watt 120V-277V emergency battery pack installed (4) GTD2=Bodine Generator Transfer Device (12) ETS2=IOTA Emergency Transfer Switch (12) CCT L830=3000K L835=3500K L840=4000K Flex (11) Multiple Configurations Available Optics Blank=Standard Series (7) 22EN=2' x 2' Encounter Series ACCESSORIES T3A END E.Q. BRACKET PARTS BAG (Standard with fixture) DF-22-W=2' x 2' Drywall Frame Kit SK-22-WS=2' x 2' Shallow Surface Mount Kit SK-22-WT=2' x 2' Tall Surface Mount Kit DF10P-C =Decorator Dimmer, 0-10V SF10P- =Decorator Slide Dimmer, 0-10V ISHH-01=Programming Remote for Integrated Sensor ISHH-02=Personal Control Remote for Integrated Sensor Rating Blank=Standard ATW-SW4=Chicago Rated(8) Lamp Type LD2=LED 2.0 Stock Lumen Outputs 25=2500 Lumens 34=3400 Lumens MTO Lumen Outputs 19=1900 Lumens 30=3000 Lumens 39=3900 Lumens 43=4300 Lumens NOTES: (1)Products also available in non-US voltages and frequencies for international markets. (2)Must be used in conjunction with a DALI control system. For complete DALI soluitions by Fifth Light, visit www.eaton.com/lightingsystems (3)1900, 2500, 3000 and 3400 lumen option are not available with a Fifth Light DALI (5LTD) driver. (4)With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (5)Step-dim driver not available with 1900, 2500, 3000 and 3400 lumen option. (6)347V emergency option not available. (7)DesignLights Consortium™ Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. (8)Chicago rated version does not allow for row mounting. (9)Air version is vented but does not meet air handling requirements; a 6% reduction in delivered lumens is experienced with this option. (10)Integral sensor works only with “CD” driver and is factory prewired to the driver for stand-alone control. (11)Flex does not include dimming leads. Control leads provided by others. (12)Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. (3), (5) (3), (5) Driver Type 5LTD=Fifth Light DALI Driver (10% - 100% Dimming) (2) 5LTHD=Fifth Light DALI Driver (1% - 100% Dimming) (2) CD=0-10V Dimming Driver (10% - 100% Dimming) HCD=0-10V Dimming Driver (1% - 100% Dimming) SD=Step-dim Driver (5) Number of Drivers 1=1 Driver Packaging U=Unit Pack PALC=Job Pack, in carton Product Family S=Integrated Sensor Control Type B=Sensor Mounting, No Sensor V=Analog (0-10V) Output for Local Control (10) Occupancy Technology P=Passive Infrared Sensing Technology D=Dimming Daylight Harvesting (Closed Loop) Coverage Pattern 1= ~144 Square Feet Air (9) [Blank]=Standard A=Air (Vented) L850=5000K (3), (5) (3), (5) ORDERING INFORMATION Catalog No. Wt. 22EN-LD2-25 14 lbs. 22EN-LD2-34 14 lbs. SHIPPING DATA PS519064EN 2016-03-22 08:35:59 22EN LED 2’ X 2’ Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting The Encounter with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Encounter delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Encounter delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The Encounter with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: • As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. • Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes). • If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. • At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. Coverage Optional Remote Controls ISHH-01 Programming Remote CL Top View Side View 4m[12 ft.] 4m[12 ft.] 0m[0 ft.] Coverage Major Motion 3.3m[10 ft.] 0m[0 ft.] 0m[0 ft.]4m[12 ft.]4m[12 ft.] Reccomended Mounting Height 8–12 ft. ProgrammingRemote ISHH-01 ToSetOutput 1. R aise,LowerorPress Min. 50,75, Max. 2. T o savepressSET 3.Select OccorUnOcc Raise/Lower TimeOut 5 10 15 20 HI LO ES SET Occ 50 MIN UnOcc MAX 75 100 0Light Level(DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level OccupiedUnoccupiedOccupiedUnoccupied Energy Savings Opportunities (DU) Unoccupied Level Target light level default: 500 lux at 8 ft. PersonalRemote ISHH-02 Raise/Lo wer SCENE MAX 75 50 MIN UnOcc ES Occ To Select Scenes PresstheSCENEbutton. The l ightingwilladjustto stored lightlev els.. ISHH-02 Personal Control Remote INTEGRATED SENSOR PS519064EN 2016-03-22 08:35:59 22EN LED 2’ X 2’ Metalux Safe and convenient means of disconnecting power Catalog # Type Date Project Comments Prepared by SPECIFICATION FEATURES Construction Shallow 3-1/4” deep housing is extruded aluminum frame and injected molded composite end plates. End plates are securely attached with screws for strength and rigidity and the elimination of gaps. End plates have accessory grid-lock feature for safety and convenience. Four auxiliary fixture end suspension points are provided. Large access plate for supply connection. Controls The Encounter LED is Powered by Fifth Light, with a standard 0-10V continuous dimming driver that works with any 0-10V control/ dimmer. Combine with energy saving products like occupancy sensors, daylighting controls and lighting relay panels to maximize energy savings. In addition, the Encounter can include a factory- installed integrated sensor system for occupancy and daylight dimming control and manual control from an optional handheld remote. Or, specify the Digital Addressable Lighting Interface (DALI) drivers, dimmable down to 1% with the HD option, for use with Fifth Light controls. See ordering information for details on all three options. Electrical Long-life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3000K, 3500K, 4000K or 5000K with a typical CRI ≤ 85. Projected life is 100,000 hours at 92% lumen output. Electronic drivers are available for 120-277V applications. Emergency Battery Pack Option Optional 120v-277v integral emergency battery pack is available in 7-watts or 14-watts to meet critical life-safety lighting requirements. The 90-minute batteries provide constant power to the LED system, ensuring code- compliance. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. See ordering information for details. Driver Access Drivers can be accessed via plenum. Finish Durable frame has high reflectance baked matte white enamel finish for luminous uniformity. Optics Precision formed optical assembly with positively retained high optical grade acrylic lenses provide a directed optical distribution using WaveStream technology. Compliance Components are UL recognized. Indoor luminaires are cULus and CSA listed for 25° C ambient environments, RoHS compliant, and comply with IESNA LM-79. LEDs comply with LM-80 standards. DesignLights Consortium™ Qualified and classified for both DLC Standard and DLC Premium, refer to www. designlights.org for details. Warranty Five year warranty. The Encounter™ redefines ambient lighting by being the first fixture to blend modern contemporary styling with the innovative WaveStream™ technology to deliver exceptional performance and superior energy savings. Encounter’s highly efficient LED system with advance optical design delivers an unparalleled combination of optimal light uniformity for enhanced visual comfort and superior efficiency for greater energy savings. Encounter is compatible with all of today's popular ceiling systems and available in a variety of configurations for application versatility. Its perfect balance of form and function make it an ideal choice for commercial office spaces, schools, hospitals, retail and other indoor ambient applications. DESCRIPTION 24EN LED 2' X 4' TROFFER LED MODULE Specification Grade Troffer CERTIFICATION DATA cULus - 1598 and 2043** Damp Location Listed CSA IC Rated LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified NOM Compliant *See Drywall Frame Kit Accessory in Ordering Information section. **Fixture construction is suitable for use in Air-handling and plenum rated spaces in accordance with Section 300.22 (C) of the National Electrical Code, Section 4.3.11.2.6.5 of NFPA 90A and Section 602.2.1.4 of ICC. PS519063EN 2016-03-22 08:36:18 23-3/4" [603mm] 3-1/4"[83mm] 23-3/4" [603mm] 3-1/4" [83mm] X=2-7/16" [62mm] X 22-15/16" [583mm] Y Y=2-1/2"[64mm] LAMP CONFIGURATIONS G Grid/Lay-in Standard F Drywall Frame Kit Ceiling Trim Type Type Exposed GridG Concealed TG or T Slot Grid G or T Flange * CEILING COMPATIBILITY 23-3/4" [603mm] 47-11/16" [1212mm] MOUNTING DATA Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 24EN LED 2’ X 4’ PS519063EN 2016-03-22 08:36:18 24EN-LD2-54-UNV- L835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height Lumens: 5410 Input Watts: 43.0W Effi cacy: 125.8 lm/W Te st Report: 24EN-LD2-54-UNV- L835-CD1-U.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 1791 1791 1791 1792 1782 1784 1770 1759 1761 1734 1721 1723 1684 1670 1673 1621 1609 1610 1550 1533 1531 1465 1444 1439 1372 1348 1344 1270 1241 1238 1153 11 24 1125 1029 997 998 893 860 867 743 706 721 588 558 550 423 401 345 258 223 226 110 106 101 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 108 103 99 95 106 101 97 93 97 93 90 93 90 88 89 87 85 83 98 90 83 77 96 88 81 76 84 79 74 81 76 72 78 74 71 68 89 78 70 63 87 77 69 63 74 67 62 71 65 60 68 64 59 57 82 69 60 53 79 68 59 53 65 58 52 63 57 51 61 55 51 49 75 62 52 46 73 61 52 45 58 51 45 56 50 44 55 49 44 42 69 55 46 40 67 54 46 40 53 45 39 51 44 39 49 43 38 36 64 50 41 35 62 49 41 35 48 40 35 46 39 34 45 39 34 32 59 46 37 31 58 45 37 31 44 36 31 42 36 31 41 35 30 28 56 42 34 28 54 41 33 28 40 33 28 39 32 28 38 32 27 26 52 39 31 25 51 38 30 25 37 30 25 36 30 25 35 29 25 23 Zonal Lumen Summary Zone Lumens % Fixture 0-30 0-40 0-60 0-90 0-180 1398 25.8 2305 42.6 4164 77.0 5410 100.0 5410 100.0 600 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 1200 1800 24EN-LD2-45-UNV- L835-CD1-U Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.3 x mounting height, () 1.3 x mounting height Lumens: 4520 Input Watts: 38.0W Effi cacy: 11 8.9 lm/W Test Report: 24EN-LD2-45-UNV- L835-CD1-U.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 1493 1493 1493 1493 1485 1487 1475 1466 1468 1445 1435 1437 1403 1392 1395 1352 1340 1342 1292 1278 1277 1222 1204 1200 1144 11 23 11 20 1060 1034 1033 964 939 939 860 833 836 748 719 724 624 591 606 492 467 460 357 337 284 218 187 192 93 90 87 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 108 103 99 95 106 101 97 93 97 93 90 93 90 88 89 87 85 83 98 90 83 77 95 88 81 76 84 79 74 81 76 72 78 74 71 68 89 78 70 63 87 77 69 63 74 67 62 71 65 60 68 64 59 57 82 69 60 53 79 68 59 53 65 58 52 63 57 51 61 55 51 48 75 62 52 46 73 61 52 45 58 51 45 56 50 44 54 49 44 42 69 55 46 40 67 54 46 39 53 45 39 51 44 39 49 43 38 36 64 50 41 35 62 49 41 35 48 40 34 46 39 34 45 39 34 32 59 46 37 31 58 45 37 31 44 36 31 42 36 31 41 35 30 28 56 42 34 28 54 41 33 28 40 33 28 39 32 27 38 32 27 25 52 39 31 25 51 38 30 25 37 30 25 36 30 25 35 29 25 23 Zonal Lumen Summary Zone Lumens% Fixture 0-30 0-40 0-60 0-90 0-180 1166 25.8 1922 42.5 3475 76.9 4520 100.0 4520 100.0 500 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 1000 1500 PHOTOMETRICS Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 24EN LED 2’ X 4’ PS519063EN 2016-03-22 08:36:18 Stock or MTO* Catalog Logic (Curved) Delivered Lumens Watts Efficacy (LPW) MTO 24EN-LD2-30-UNV-L830-CD1-U 2935 24.6 11 9 MTO 24EN-LD2-30-UNV-L835-CD1-U 3026 24.6 123 MTO 24EN-LD2-30-UNV-L840-CD1-U 3087 24.6 125 MTO 24EN-LD2-30-UNV-L850-CD1-U 3359 24.6 137 MTO 24EN-LD2-34-UNV-L830-CD1-U 3400 28.7 11 8 MTO 24EN-LD2-34-UNV-L835-CD1-U 3505 28.7 122 MTO 24EN-LD2-34-UNV-L840-CD1-U 3575 28.7 125 MTO 24EN-LD2-34-UNV-L850-CD1-U 3891 28.7 136 MTO 24EN-LD2-40-UNV-L830-CD1-U 3960 33.9 11 7 MTO 24EN-LD2-40-UNV-L835-CD1-U 4082 33.9 120 MTO 24EN-LD2-40-UNV-L840-CD1-U4164 33.9 123 MTO 24EN-LD2-40-UNV-L850-CD1-U 4531 33.9 134 MTO 24EN-LD2-45-UNV-L830-CD1-U 4384 38.0 11 5 STOCK 24EN-LD2-45-UNV-L835-CD1-U 4520 38.0 119 STOCK 24EN-LD2-45-UNV-L840-CD1-U 4610 38.0 121 MTO 24EN-LD2-45-UNV-L850-CD1-U5017 38.0 132 MTO 24EN-LD2-49-UNV-L830-CD1-U 4802 42.2 11 4 MTO 24EN-LD2-49-UNV-L835-CD1-U 4950 42.2 11 7 MTO 24EN-LD2-49-UNV-L840-CD1-U 5049 42.2 120 MTO 24EN-LD2-49-UNV-L850-CD1-U 5494 42.2 130 MTO 24EN-LD2-54-UNV-L830-CD1-U 5248 43.0 122 STOCK 24EN-LD2-54-UNV-L835-CD1-U 5410 43.0 126 STOCK 24EN-LD2-54-UNV-L840-CD1-U 5518 43.0 128 MTO 24EN-LD2-54-UNV-L850-CD1-U6005 43.0 140 MTO 24EN-LD2-58-UNV-L830-CD1-U 5663 47.0 120 MTO 24EN-LD2-58-UNV-L835-CD1-U 5838 47.0 124 MTO 24EN-LD2-58-UNV-L840-CD1-U 5955 47.0 127 MTO 24EN-LD2-58-UNV-L850-CD1-U 6480 47.0 138 MTO 24EN-LD2-67-UNV-L830-CD1-U 6529 56.1 11 6 STOCK 24EN-LD2-67-UNV-L835-CD1-U 6731 56.1 120 STOCK 24EN-LD2-67-UNV-L840-CD1-U 6866 56.1 122 MTO 24EN-LD2-67-UNV-L850-CD1-U 7471 56.1 133 MTO 24EN-LD2-70-UNV-L830-CD1-U 6812 60.2 11 3 MTO 24EN-LD2-70-UNV-L835-CD1-U 7023 60.2 11 7 MTO 24EN-LD2-70-UNV-L840-CD1-U7163 60.2 119 MTO 24EN-LD2-70-UNV-L850-CD1-U 7796 60.2 130 MTO 24EN-LD2-74-UNV-L830-CD1-U 7259 63.6 114 MTO 24EN-LD2-74-UNV-L835-CD1-U7484 63.6 11 8 MTO 24EN-LD2-74-UNV-L840-CD1-U7634 63.6 120 MTO 24EN-LD2-74-UNV-L850-CD1-U 8307 63.6 131 *Made to order (MTO) requires a typical two week lead time. ENERGY AND PERFORMANCE DATA BY CATALOG NUMBER Ambient Temperature TM-21 Lumen Maintenance (100,0000 hours) Theoretical L70 (Hours) 25°C > 92%> 448,000 Non-IC data LUMEN MAINTENANCE Type C Type B Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting 24EN LED 2’ X 4’ PS519063EN 2016-03-22 08:36:18 SAMPLE NUMBER: 24EN-LD2-67-UNV-L835-CD1-SVPD1-U Voltage(1) 347V=347 Volt(5), (9) UNV=Universal Voltage 120-277 Options Emergency EL7W=7-watt, 120V-277V emergency battery pack installed (3) EL14W=14-watt 120V-277V emergency battery pack installed (3) GTD2=Bodine Generator Transfer Device (14) ETS2=IOTA Emergency Transfer Switch (14) CCT L830=3000K L835=3500K L840=4000K Flex (12) Multiple Configurations Available Optics Blank=Standard Series (6) 24EN=2' x 4' Encounter Series Air (10) [Blank]=Standard A=Air (Vented) Rating Blank=Standard ATW-SW4=Chicago Rated(7)Stock Lumen Outputs 45=4500 Lumens 54=5400 Lumens 67=6700 Lumens MTO Lumen Outputs 30=3000 Lumens (4), (15) 34=3400 Lumens (4), (15) 40=4000 Lumens 49=4900 Lumens 58=5800 Lumens 70=7000 Lumens 74=7400 Lumens Lamp Type LD2=LED 2.0 ACCESSORIES T3A END E.Q. BRACKET PARTS BAG (Standard with fixture) DF-24-W=2' x 4' Drywall Frame Kit SK-24-WS=2' x 4' Shallow Surface Mount Kit SK-24-WT=2' x 4' Tall Surface Mount Kit DF10P-C =Decorator Dimmer, 0-10V SF10P- =Decorator Slide Dimmer, 0-10V ISHH-01=Programming Remote for Integrated Sensor ISHH-02=Personal Control Remote for Integrated Sensor NOTES: (1)Products also available in non-US voltages and frequencies for international markets. (2)Must be used in conjunction with a DALI control system. For complete DALI solutions by Fifth Light, visit www.eaton.com/lightingsystems (3)With integral test switch/indicator/laser test. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (100 lm/W x 7=700 lumens). IES-format photometry for luminaire under emergency operation available. (4)Step-dim driver not available with 3000, 3400, 7000 and 7400 lumen options. (5)347V emergency option not available. (6)DesignLights Consortium™ Qualified and classified for both DLC Standard and DLC Premium, refer to www.designlights.org for details. (7)Chicago rated version does not allow for row mounting. (8)Two drivers required for 5LTHD option for 6400 lumens and up. (9)347V option not available with 7400 lumen package. (10)Air version is vented but does not meet air handling requirements; a 6% reduction in delivered lumens is experienced with this option. (11)Integral sensor works only with “CD” driver and is factory prewired to the driver for stand-alone control. (12)Flex does not include dimming leads. Control leads provided by others. (13)HCD driver option is not available with 7000 and 7400 lumen packages. Two drivers required for 6700 lumen package. (14)Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (15)5LTD DALI option not available with 3000 and 3400 lumen packages. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. Driver Type CD=0-10V Dimming Driver (10% - 100% Dimming) HCD=0-10V Dimming Driver (1% - 100% Dimming) (13) SD=Step-dim Driver (4), (15) 5LTD=Fifth Light DALI Driver (10% - 100% Dimming) (2), (15) 5LTHD=Fifth Light DALI Driver (1% - 100% Dimming) (2), (8) Number of Drivers 1=1 Driver 2=2 Drivers (13) Packaging U=Unit Pack PALC=Job Pack, in carton Product Family S=Integrated Sensor Control Type B=Sensor Mounting, No Sensor V=Analog (0-10V) Output for Local Control (11) Occupancy Technology P=Passive Infrared Sensing Technology D=Dimming Daylight Harvesting (Closed Loop) Coverage Pattern 1= ~144 Square Feet L850=5000K ORDERING INFORMATION Catalog No. Wt. 24EN-LD2-45 28 lbs. 24EN-LD2-54 28 lbs. 24EN-LD2-67 28 lbs. SHIPPING DATA Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting The Encounter with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Encounter delivers superior lighting with integrated occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Encounter delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. Each luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. Occupied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-01). The integrated sensor personal remote (Catalog Number: ISHH-02) provides code compliant manual raise, lower, ON, OFF control. The Encounter with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: • As the user enters the space controlled by the integral sensor, the lighting turns ON to the default daylight level. • Lighting will remain at that the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 20 minutes). • If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. • At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. Coverage Optional Remote Controls ISHH-01 Programming Remote CL Top View Side View 4m[12 ft.] 4m[12 ft.] 0m[0 ft.] Coverage Major Motion 3.3m[10 ft.] 0m[0 ft.] 0m[0 ft.]4m[12 ft.]4m[12 ft.] Reccomended Mounting Height 8–12 ft. ProgrammingRemote IS HH-01 ToSetOutput 1. R aise,LowerorPress Min. 5 0,75, Max. 2. T o savepressSET 3.Select OccorUnOcc Raise/Lower TimeOut 5 10 15 20 HI LO ES SET Occ 50 MIN UnOcc MAX 75 100 0Light Level(DO) Daylight Level (DO) Daylight Level Timeout Value (ES) Energy Saver Light Level OccupiedUnoccupiedOccupiedUnoccupied Energy Savings Opportunities (DU) Unoccupied Level Target light level default: 500 lux at 8 ft. PersonalRemote ISHH-02 Raise/Lo wer SCENE MAX 75 50 MIN UnOcc ES Occ To Select Scenes PresstheSCENE button. The l ightingwilladjustto stored lightlevels.. ISHH-02 Personal Control Remote INTEGRATED SENSOR 24EN LED 2’ X 4’ PS519063EN 2016-03-22 08:36:18 TD517003EN 5/28/2015 Catalog # Project Comments Prepared by Type Date SPECIFICATION FEATURES DESCRIPTION Recessed 6-inch LED lens downlight is available in various distributions, lumen and CRI/CCT options. Suitable for commercial construction and can be used for both new or renovation work. Insulation must be kept 3” from top and sides of housing. Use for general area lighting where high efficiency and visual comfort are required. MECHANICAL Frame Boat shaped galvanized steel frame with adjustable plaster lip accommodates ceilings up to ½ - 2” thick. May be used for new construction or remodeling installations. Provided with (2) remodel clips to secure frame when installed from below the ceiling. Mounting Brackets Bar hanger receivers adjusts 2” vertically from above the ceiling or thru the aperture. Use with No Fuss™ bar hangers or with ½” EMT. Removable to facilitate installation from below the ceiling. No Fuss™ Bar Hangers Captive preinstalled bar hanger locks to tee grid with a screwdriver or pliers. Centering mechanism allows consistent positioning of fixtures. OPTICAL LED Module Proximity phosphors over chip on board LEDs provide a uniform source with high efficiency and no pixilation. Available in 80 or 90 CRI minimum, accuracy within 3 SDCM provides color uniformity. See ordering information for available CRI / CCT options. Passive thermal management achieves L70 at 50,000 hours in non IC applications. Integral diffuse lens provides visual shielding. Integral connector allows quick connection to housing flex. Reflector One piece parabolic aluminum reflector provides cutoff for a visually comfortable optic. Attaches to LED module with (3) speed clamps minimizing light leaks to lens. Self-flanged standard with an optional white painted flange. Trim Retention Reflectors are retained with two torsion springs holding the flange tightly to the finished ceiling surface. ELECTRICAL Junction Box (6) ½” and (2) ¾” trade size pry outs positioned to allow straight conduit runs. Listed for (12) #12 AWG (six in, six out) 90°C conductors and feed thru branch wiring. Driver Integral UNV 120 - 277V 50/60 Hz constant current driver provides noise free operation. For 347V input use Halo transformer H347 or H347200. Continuous, flicker- free dimming from 100% to 10% with leading or trailing edge phase cut at 120V or 0 -10V analog control. Emergency Option Provides 90 minutes of standby lighting meeting most life safety codes for egress lighting. Available with both integral or remote charge indicator and test switch. Compliance - cULus listed for wet location - cCSAus listed for wet location - IP66 Ingress Protection Rated - Insulation must be kept 3” from top and sides. - Airtight per ASTM-E283. - Optional City of Chicago environmental air (CCEA) marking for plenum applications. - EMI/RFI emissions per FCC 47CFR Part 18 non-consumer limits. - Contains no mercury or lead and RoHS compliant. - Photometric testing in accordance with IES LM-79-08. - Lumen maintenance projections in accordance with IES LM-80-08 and TM-21-11. - Can be used to comply with California Title 24 Non-Residential Lighting Controls requirements as a LED Luminaire. - ENERGY STAR® listed for commercial applications, reference database for current listings. PD610 PD615 PD620 PD630 PDM6A 61V 1000, 1500, 2000 & 3000 Lumen Series LED 6-Inch Aperture Lens Downlight Lumens 1000 Series Input Voltage 120V 277V Input Current .103 A .058 A Input Power 12.1 W 13.2 W Efficiency 88 LPW 88 LPW Inrush Current .048 A .080 A Lumens 1500 Series Input Voltage 120V 277V Input Current .146 A .1 A Input Power 17.1 W 17.9 W Efficiency 87 LPW 87 LPW Inrush Current 1.920 A 0.960 A Lumens 2000 Series Input Voltage 120V 277V Input Current .175 A .536 A Input Power 20.78 W 21.06 W Efficiency 89 LPW 89 LPW Inrush Current .064 A .128 A Lumens 3000 Series Input Voltage 120V 277V Input Current .299 A .145 A Input Power 35.72 W 36.4 W Efficiency 82 LPW 82 LPW Inrush Current .096 A .928 A THD: ≤ 20% PF: ≥ 0.90 T Ambient -30 - +40°C Sound Rating ≤ 22dba Halo Commercial PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial ORDERING INFORMATION SAMPLE NUMBER: PD610ED010REM-PDM6A827-61VC A complete luminaire consists of a housing, LED module and reflector, order separately. Housing Lumens Driver Options LED Module CRI/CCT PD6 = 6" aperture LED downlight PD6CP = 6" aperture LED downlight, CCEA listed for City of Chicago plenum requirements 10 = 1,000 lumens (nominal) 15 = 1,500 lumens (nominal) 20 = 2,000 lumens (nominal) ED010 = 120-277V 50/60Hz, 0-10V and LE/TE phase cut dimming REM = Emergency operation with remote indicator and test switch IEM = Emergency operation with integral indicator and test switch, 60 Hz only (REM and IEM options not available with PD6CP housing) PDM6A = Downlight LED module for PD6 housing, provides 1,000, 1,500, 2,000, or 3,000 lumens (nominal) depending on connected housing type 827 = 80 CRI, 2700K CCT 927 = 90 CRI, 2700K CCT 830 = 80 CRI, 3000K CCT 930 = 90 CRI, 3000K CCT 835 = 80 CRI, 3500K CCT 935 = 90 CRI, 3500K CCT 840 = 80 CRI, 4000K CCT 940 = 90 CRI, 4000K CCT30 = 3,000 lumens (nominal)D010 = 120-277V 50/60Hz, 0-10V dimming (3,000 lumen only) Reflector Finish Option Flange Option Accessories 61V = 6" vertical parabolic reflector 61VEM = 6" vertical parabolic reflector for IEM C = Specular clear G = Specular gold H = Semi-specular clear W = White (white flange) BB = Black baffle (white flange) WB = White baffle (white flange) Blank = Polished flange standard with C, G & H reflector finishes Blank = White flange standard with W, BB, & WB WF = White flange option available with C, G, & H reflector finishes HB128APK = L channel hanger bar, 26", ‘No-Fuss’, pair (replacement) RMB22 = 22" long wood joist mounting bars, pair H347 = Step down transformer for 347V input H347 = Step down transformer for 347V input, 75VA max H347200 = Step down transformer for 347V input, 200VA max DIMENSIONS 7"[180 mm] 7"[180 mm] 6"[155 mm] ID 26"[671 mm] 7.75"[197 mm] OD 7.25"[184 mm] 6"[155 mm] ID 7.25"[184 mm] 7.75"[197 mm] OD 26"[671 mm] 13"[339 mm] 13"[333 mm] 13"[333 mm] 7.5"[190 mm] 7.5"[190 mm] PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial COMPLIANCE TABLE 1000 LUMEN 1500 LUMEN 80 CRI Catalog #PD610ED010- PDM6A827 PD610ED010- PDM6A830 PD610ED010- PDM6A835 PD610ED010- PDM6A840 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1032 77 1109 83 1177 88 1187 89 61VCWF 1005 75 1080 81 1146 86 1156 86 61VG 1003 75 1078 80 1144 85 1154 86 61VGWF 966 72 1039 78 1102 82 1111 83 61VH 924 69 993 74 1053 79 1062 79 61VHWF 921 69 990 74 1051 78 1060 79 61VW 960 72 1032 77 1095 82 1104 82 61VBB 897 67 964 72 1023 76 1031 77 61VWB 980 73 1053 79 1118 83 1127 84 90 CRI Catalog #PD610ED010- PDM6A927 PD610ED010- PDM6A930 PD610ED010- PDM6A935 PD610ED010- PDM6A940 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 795 59 853 64 917 68 1017 76 61VCWF 775 58 831 62 894 67 990 74 61VG 773 58 829 62 892 67 988 74 61VGWF 745 56 799 60 859 64 952 71 61VH 712 53 763 57 821 61 910 68 61VHWF 710 53 761 57 819 61 908 68 61VW 740 55 794 59 854 64 946 71 61VBB 691 52 741 55 797 59 884 66 61VWB 755 56 810 60 871 65 966 72 80 CRI Catalog #PD615ED010- PDM6A827 PD615ED010- PDM6A830 PD615ED010- PDM6A835 PD615ED010- PDM6A840 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1417 77 1523 82 1616 87 1630 88 61VCWF 1380 75 1483 80 1574 85 1587 86 61VG 1377 74 1480 80 1570 85 1584 86 61VGWF 1327 72 1426 77 1513 82 1526 82 61VH 1268 69 1363 74 1446 78 1458 79 61VHWF 1265 68 1359 73 1442 78 1455 79 61VW 1318 71 1417 77 1503 81 1516 82 61VBB 1231 67 1323 72 1404 76 1416 77 61VWB 1346 73 1446 78 1534 83 1548 84 90 CRI Catalog #PD615ED010- PDM6A927 PD615ED010- PDM6A930 PD615ED010- PDM6A935 PD615ED010- PDM6A940 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1092 59 1171 63 1260 68 1396 75 61VCWF 1064 57 1141 62 1227 66 1360 74 61VG 1061 57 1138 62 1224 66 1357 73 61VGWF 1022 55 1096 59 1179 64 1307 71 61VH 977 53 1048 57 1127 61 1249 68 61VHWF 975 53 1045 57 1124 61 1246 67 61VW 1016 55 1090 59 1172 63 1299 70 61VBB 949 51 1018 55 1095 59 1213 66 61VWB 1037 56 1112 60 1196 65 1326 72 T24es T24 = Can be used to comply with California Title 24 Non-ResidentialES = ENERGY STAR® Compliant PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial COMPLIANCE TABLE continued 3000 LUMEN 80 CRI Catalog #PD630D010- PDM6A827 PD630D010- PDM6A830 PD630D010- PDM6A835 PD630D010- PDM6A840 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 2576 72 2768 78 2937 82 2963 83 61VCWF 2509 70 2697 76 2861 80 2886 81 61VG 2503 70 2691 75 2855 80 2879 81 61VGWF 2412 68 2592 73 2750 77 2774 78 61VH 2305 65 2477 69 2629 74 2651 74 61VHWF 2299 64 2471 69 2622 73 2645 74 61VW 2397 67 2576 72 2733 77 2757 77 61VBB 2238 63 2406 67 2553 72 2575 72 61VWB 2446 69 2629 74 2790 78 2814 79 90 CRI Catalog #PD630D010- PDM6A927 PD630D010- PDM6A930 PD630D010- PDM6A935 PD630D010- PDM6A940 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1985 56 2129 60 2290 64 2538 71 61VCWF 1934 54 2074 58 2231 62 2472 69 61VG 1929 54 2069 58 2226 62 2466 69 61VGWF 1859 52 1993 56 2144 60 2376 67 61VH 1776 50 1905 53 2049 57 2271 64 61VHWF 1772 50 1900 53 2044 57 2265 63 61VW 1847 52 1981 55 2131 60 2361 66 61VBB 1725 48 1850 52 1990 56 2205 62 61VWB 1885 53 2022 57 2175 61 2410 68 2000 LUMEN 80 CRI Catalog #PD620ED010- PDM6A827 PD620ED010- PDM6A830 PD620ED010- PDM6A835 PD620ED010- PDM6A840 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1724 78 1853 84 1966 89 1983 90 61VCWF 1679 76 1805 82 1915 87 1931 88 61VG 1675 76 1801 82 1910 87 1927 88 61VGWF 1614 73 1735 79 1841 84 1856 84 61VH 1543 70 1658 75 1759 80 1774 81 61VHWF 1539 70 1654 75 1755 80 1770 80 61VW 1604 73 1724 78 1829 83 1845 84 61VBB 1498 68 1610 73 1708 78 1723 78 61VWB 1637 74 1759 80 1867 85 1883 86 90 CRI Catalog #PD620ED010- PDM6A927 PD620ED010- PDM6A930 PD620ED010- PDM6A935 PD620ED010- PDM6A940 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 Lumens LPW ES T24 61VC 1328 60 1425 65 1532 70 1698 77 61VCWF 1294 59 1388 63 1493 68 1654 75 61VG 1291 59 1385 63 1489 68 1651 75 61VGWF 1244 57 1334 61 1435 65 1590 72 61VH 1189 54 1275 58 1371 62 1520 69 61VHWF 1186 54 1272 58 1368 62 1516 69 61VW 1236 56 1325 60 1426 65 1580 72 61VBB 1154 52 1238 56 1332 61 1476 67 61VWB 1262 57 1353 61 1455 66 1613 73 T24es T24 = Can be used to comply with California Title 24 Non-ResidentialES = ENERGY STAR® Compliant PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial PHOTOMETRY - 1000 lumen / 80 CRI PD610ED010- PDM6A935-61VC Spacing Criteria = 0.76 Lumens per Watt = 75.8 Lm/W Test No. P137041 Test Model: PD610ED010- PDM6A935-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 3737 55 392 65 182 75 148 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 691 75.3 0-40 868 94.6 0-60 916 99.8 0-90 917 100 Candela Distribution DegreesVertical Candela 0*1298 5 1258 10 1146 20 824 30 475 40 130 50 14 60 2 70 1 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5'52 4.4 4.4 7'32.1 5.8 5.8 8'24.6 6.6 6.6 9'19.4 7.4 7.4 10'15.7 8.2 8.2 12'10.9 10 10 Candlepower Distribution Eyeball at 0-degrees 15º0º 450 900 1350 30º 45º 60º 75º 90º QRM VMM NPRM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PD610ED010- PDM6A835-61VC Spacing Criteria = 0.76 Lumens per Watt = 97.3 Lm/W Test No. P137037 Test Model: PD610ED010- PDM6A835-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 4791 55 497 65 221 75 191 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 886 75.3 0-40 1113 94.6 0-60 1175 99.8 0-90 1177 100 Candela Distribution DegreesVertical Candela 0*1665 5 1614 10 1469 20 1057 30 609 40 166 50 18 60 3 70 1 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 55.1 4 4 7 34 5.2 5.2 8 26 6 6 9 20.6 6.8 6.8 10 16.7 7.6 7.6 12 11.6 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 600 1200 1800 30º 45º 60º 75º 90º SMM NOMM NUMM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PHOTOMETRY - 1000 lumen / 90 CRI Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 PHOTOMETRY - 1500 lumen / 90 CRI PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial PHOTOMETRY - 1500 lumen / 80 CRI PD615ED010- PDM6A935-61VC Spacing Criteria = 0.76 Lumens per Watt = 68.1 Lm/W Test No. P166942 Test Model: PD615ED010- PDM6A935-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 5132 55 535 65 246 75 191 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 948 75.3 0-40 1192 94.6 0-60 1257 99.8 0-90 1260 100 Candela Distribution DegreesVertical Candela 0*1783 5 1728 10 1573 20 1132 30 652 40 178 50 20 60 3 70 1 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 58.9 4 4 7 36.4 5.2 5.2 8 27.9 6 6 9 22 6.8 6.8 10 17.8 7.6 7.6 12 12.4 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 600 1200 1800 30º 45º 60º 75º 90º SMM NOMM NUMM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PD615ED010- PDM6A835-61VC Spacing Criteria = 0.76 Lumens per Watt = 87.3 Lm/W Test No. P166938 Test Model: PD615ED010- PDM6A835-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 6582 55 688 65 311 75 254 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 1217 75.3 0-40 1529 94.6 0-60 1613 99.8 0-90 1616 100 Candela Distribution DegreesVertical Candela 0*2287 5 2216 10 2018 20 1452 30 836 40 228 50 25 60 4 70 1 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 75.6 4 4 7 46.7 5.2 5.2 8 35.7 6 6 9 28.2 6.8 6.8 10 22.9 7.6 7.6 12 15.9 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 800 1600 2400 30º 45º 60º 75º 90º UMM NSMM OQMM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial PHOTOMETRY - 2000 lumen / 80 CRI PD620ED010- PDM6A935-61VC Spacing Criteria = 0.76 Lumens per Watt = 69.7 Lm/W Test No. P137025 Test Model: PD620ED010- PDM6A935-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 6241 55 650 65 298 75 233 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 1154 75.3 0-40 1450 94.6 0-60 1530 99.8 0-90 1532 100 Candela Distribution DegreesVertical Candela 0*2168 5 2102 10 1913 20 1377 30 793 40 217 50 24 60 3 70 1 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 71.7 4 4 7 44.3 5.2 5.2 8 33.9 6 6 9 26.8 6.8 6.8 10 21.7 7.6 7.6 12 15.1 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 750 1500 2250 30º 45º 60º 75º 90º TRM NRMM OORM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PD620ED010- PDM6A835-61VC Spacing Criteria = 0.76 Lumens per Watt = 89.4 Lm/W Test No. P137021 Test Model: PD620ED010- PDM6A835-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 8009 55 832 65 376 75 318 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 1480 75.3 0-40 1860 94.6 0-60 1962 99.8 0-90 1966 100 Candela Distribution DegreesVertical Candela 0*2782 5 2696 10 2454 20 1766 30 1017 40 278 50 31 60 4 70 2 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 92 4 4 7 56.8 5.2 5.2 8 43.5 6 6 9 34.3 6.8 6.8 10 27.8 7.6 7.6 12 19.3 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 950 1900 2850 30º 45º 60º 75º 90º VRM NVMM OURM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PHOTOMETRY - 2000 lumen / 90 CRI Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Specifications and dimensions subject to change without notice. PD610/PD615/PD620/PD630 PDM6A 61V H alo Commercial PHOTOMETRY - 3000 lumen / 80 CRI PD630ED010- PDM6A935-61VC Spacing Criteria = 0.76 Lumens per Watt = 64.1 Lm/W Test No. P137057 Test Model: PD630ED010- PDM6A935-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 9327 55 975 65 441 75 360 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 1724 75.3 0-40 2166 94.6 0-60 2286 99.8 0-90 2290 100 Candela Distribution DegreesVertical Candela 0*3240 5 3140 10 2859 20 2058 30 1185 40 324 50 36 60 5 70 2 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 107.1 4 4 7 66.1 5.2 5.2 8 50.6 6 6 9 40 6.8 6.8 10 32.4 7.6 7.6 12 22.5 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 1100 2200 3300 30º 45º 60º 75º 90º NNMM OOMM PPMM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PD630ED010- PDM6A835-61VC Spacing Criteria = 0.76 Lumens per Watt = 82.3 Lm/W Test No. P137053 Test Model: PD630ED010- PDM6A835-61VC Luminance (Average Candela/M2) Degree Avg. 0°Luminance 45 11970 55 1242 65 558 75 466 85 0 Zonal Lumen Summary Zone Lumens % Fixture 0-30 2212 75.3 0-40 2779 94.6 0-60 2932 99.8 0-90 2937 100 Candela Distribution DegreesVertical Candela 0*4157 5 4028 10 3668 20 2639 30 1520 40 415 50 46 60 6 70 2 80 0 90 0 *CBCP Beam diameter is to 50% of maximum footcandles, rounded to the nearest half-foot. Footcandle values are initial, apply appropriate light loss factors where necessary. Cone of Light Footcandles Distance toIlluminatedPlane Initial NadirFootcandles Beam (ft.) L Length W Width 5.5 137.4 4 4 7 84.8 5.2 5.2 8 65 6 6 9 51.3 6.8 6.8 10 41.6 7.6 7.6 12 28.9 9 9 Candlepower Distribution Eyeball at 0-degrees 15º0º 1400 2800 4200 30º 45º 60º 75º 90º NQMM OUMM QOMM M˚NR˚PM˚ QR˚ SM˚ TR˚ VM˚ PHOTOMETRY - 3000 lumen / 90 CRI Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Scaling factor for the Battery back up: - 1000 Lumen = 0.55 - 1500 Lumen = 0.40 - 2000 Lumen = 0.33 - 3000 Lumen = 0.22 Metalux INDUSTRIAL LED LINEAR BAY LED Linear Bay Lighting System Catalog # Type Date Project Comments Prepared by SPECIFICATION FEATURES Construction Specification grade full body housing, end plates and socket tracks are die formed cold rolled steel in 4’ or 8’ lengths. The housing features an integral driver channel that adds strength and provides numerous KO’s for easy installation. Electrical Long-life LED system coupled with electrical driver to deliver optimal performance. LED’s available in 3500k, 4000k and 5000k with a CRI ≥ 80. cULus listed. Electronic drivers are available for 120-277V, 347V and 480V applications. 0-10V dimming driver is standard. Optional modular power receptacle meets UL2459 and NEC 410.73 and is UL/cUL rated for make and break under load from outside the luminaire to speed maintenance. Finish Electrostatically applied baked white enamel finish is preceded by a multistage cleaning cycle, iron phosphate coating with rust inhibitor. Optics Optical modules are enclosed inside housing to protect against damage. Available in narrow or wide distributions. Narrow beam optical modules utilize 95% specular aluminum finish. An optional attractive thin blade white baffle adds longitudinal shielding. A clear or frosted white acrylic lens is also available. Optional heavy duty wireguard can be used with or without the lens or baffle. Latched retention of shielding optics (safety leader restraints) allows for easy access. Mounting Suitable for surface, suspension mounting with optional wire hook and chain set, stem or cable mounting. Top connector box mounting is also available. Narrow 11” housing allows mounting within 12” horizontally from the nearest edge of the sprinkler deflector. Compliance Luminaires are cULus listed for damp locations -20°C - 45°C ambient environments. RoHS compliant, and LED modules comply with IESNA LM-79/ LM-80 standards. DesignLights Consortium™ Qualified and classified for DLC Standard, refer to www.designlights.org for details. Options Integral Occupancy Sensor available and provides from 600 sq. ft. (MS) up to 1250 sq. ft. (MSO) of coverage at a maximum mounting height of 40’. PS519040EN 2016-06-17 11:22:38 The Industrial LED Linear Bay is the energy efficient solution for both low bay and high bay applications. The Linear Bay has been optimized to provide maximum performance utilizing the latest in LED technology. Several lumen packages and distributions make it suitable for a wide range of applications including “big box” retail, shopping malls, school gymnasiums, light industrial, warehouse and manufacturing. DESCRIPTION CERTIFICATION DATA Damp Location Listed LM79/LM80 Compliant ROHS Compliant DesignLights Consortium™ Qualified ENERGY DATA Catalog No. Input Watts 4ILED-LD4-5 35 4ILED-LD4-7 57 4ILED-LD4-9 74 4ILED-LD4-11 101 4ILED-LD4-14 115 4ILED-LD4-16 145 Safe and convenient means of disconnecting power 4-15/16" [126mm] 11" [280mm] NARROW DISTRIBUTION 92" [2337mm] 46" [1168mm] 2-3/4" [70mm] Top Connector Box Mounting 11/16" [18mm] K.O.for Cable or Pendant Mounting 11" [280mm] 11/16" [18mm] K.O.for Cable or Pendant Mounting Access Plate 4-15/16" [126mm] 11" [280mm] WIDE DISTRIBUTION 11" [280mm] 11/16" [18mm] K.O. (2)for Cable or Pendant Mounting 46" [1168mm] Top Connector Box Mounting MOUNTING DATA Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting INDUSTRIAL BAY LED Modular Power Supply Option 1.Modular Power Supply Receptacle supplied mounted into fixture Access Plate 2.Modular Power Cord & Plugs in 120, 277, 347,& 480V configurations for easy plug & power into existing supply Modular Motion Sensor Option suppliedwith Mounting Box andModular Power Supply Receptacle No internal fixture access required forinstallation or disconnecting power Code Compliance •UL/cUL Certified for Make/Break under load (UL2549) •Meets NEC requirements for ballast disconnect (NEC 410.73G) •Allows for addition of Occupancy Sensor without hard connections •Receptacles complete with insulating/dust cap Eaton’s Modular Power Supply option is available for use with all Metalux products. The modular power supply allows external fixture access for safe and easy servicing. There is no need to remove lamps or reflectors to disconnect fixture power with Modular Power Supply. Access to the individual fixture’s power supply allows servicing without turning off all the fixtures, disrupting occupants. The Modular Power Supply is a time-saver in installation – simply plug & power. 12 4ILED-LD4-7-W- UNV-L840 Electronic Driver Linear LED 4000K Spacing criterion: (II) 1.3 x mounting height, () 1 .3 x mounting height Lumens: 7246 Input Watts: 56.6W Effi cacy: 120 lm/W Test Report: 4ILED-LD4-7-W- UNV-L840.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 2511 2511 2511 2501 2499 2510 2477 2474 2482 2431 2428 2439 2366 2371 2383 2285 2295 2308 2187 2205 2224 2058 2103 2120 1910 1987 1983 1748 1832 1836 1577 1660 1667 1373 1467 1484 1166 1256 924 942 1029 556 707 425 434 468 300 222 243 135 70 68 46 45 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 109 105 101 97 107 103 99 96 98 95 93 95 92 90 91 89 87 85 100 92 85 80 97 90 84 79 86 81 77 83 79 75 80 77 73 71 91 81 73 66 89 79 72 66 76 70 65 73 68 64 71 66 62 60 83 71 63 56 81 70 62 56 68 61 55 65 59 54 63 58 54 51 77 64 55 48 74 63 54 48 61 53 48 59 52 47 57 51 47 44 71 57 48 42 69 56 48 42 55 47 42 53 46 41 51 45 41 39 65 52 43 37 64 51 43 37 50 42 37 48 41 36 47 41 36 34 61 47 39 33 59 47 38 33 45 38 33 44 37 32 43 37 32 30 57 43 35 30 55 43 35 30 42 34 29 41 34 29 39 33 29 27 53 40 32 27 52 39 32 27 38 31 27 37 31 26 37 31 26 25 Zonal Lumen Summary Zone Lumens% Fixture 0-30 0-40 0-60 0-90 0-180 1986 27.4 3299 45.5 5987 82.6 7246 100.0 7246 100.0 850 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 1700 2550 Luminance Data Anglein Deg Average 0-Degcd/sm Average 45-Degcd/sm Average 90-Degcd/sm 45 55 65 75 85 1748 1832 1836 1373 1467 1484 942 1029 556 468 300 222 68 46 45 PS519040EN 2016-06-17 11:22:38 4ILED-LD4-7-N- UNV-L835 Electronic Driver Linear LED 3500K Spacing criterion: (II) 1.3 x mounting height, () 0.6 x mounting height Lumens: 6392 Input Watts: 57.0W Effi cacy: 11 2.1 lm/W Te st Report: 4ILED-LD4-7-N-UNV- L835.IES 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Candlepower Angle Along II 45°Across 6355 6355 6355 6328 6165 6133 6247 5951 5334 6119 4995 3720 5948 3680 3091 5718 3255 11 70 5459 2079 482 5130 846 102 4764 353 69 4350 79 30 3857 45 15 3377 26 14 2824 21 13 2251 19 12 1661 17 11 1056 16 10 525 14 7 95 10 6 0 0 0 Coefficients of Utilization Effective fl oor cavity refl ectance 20% rc 80%70%50%30%10%0% rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 1 2 3 4 5 6 7 8 9 10 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100 112 108 105 102 109 106 103 101 102 100 98 98 96 95 95 93 92 90 105 99 94 89 102 97 92 88 93 90 86 90 87 84 87 85 83 81 98 90 84 79 96 89 83 78 86 81 77 83 79 76 81 78 75 73 92 83 76 71 90 81 75 70 79 74 70 77 72 69 75 71 68 66 86 76 69 64 85 75 69 64 73 68 63 72 67 63 70 66 62 60 81 71 64 59 80 70 63 58 68 62 58 67 62 58 65 61 57 55 77 66 59 54 75 65 58 54 64 58 53 62 57 53 61 56 53 51 73 62 55 50 71 61 54 50 60 54 50 59 53 49 58 53 49 48 69 58 51 46 67 57 51 46 56 50 46 55 50 46 54 49 46 44 65 54 48 43 64 54 48 43 53 47 43 52 47 43 51 46 43 41 Zonal Lumen Summary Zone Lumens % Fixture 0-30 0-40 0-60 0-90 0-180 3500 54.8 4603 72.0 5906 92.4 6392 100.0 6392 100.0 Luminance Data Angle in Deg Average0-Deg cd/sm Average45-Deg cd/sm Average90-Deg cd/sm 45 55 65 75 85 4350 79 30 3377 26 14 2251 19 12 1056 16 10 95 10 6 2150 0˚15˚30˚ 45˚ 60˚ 75˚ 90˚ 4300 6450 PHOTOMETRICS Ambient Temperature TM-21 Lumen Maintenance (60,000 hours) Theoretical L70 (Hours) 35°C > 86%171,000 LUMEN MAINTENANCE Specifications and dimensions subject to change without notice. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting SAMPLE NUMBER: 4ILED-LD4-9-W-FL-UNV-L840-CD1-U Lamp Type LD4=LED 4.0 Series (10) ILED=LED High Bay Length 4=4' Length 8=8' Length Voltage UNV=Universal 120-277 Voltage UNC=Universal 347/480 Voltage 120V=120 Volt 277V=277 Volt 347V=347 Volt (4) 480V=480 Volt (4) Shielding Options Blank=Open TBW=Thin White Baffle (5) FL=Frosted Acrylic Lens & Frame (2), (5) FL/UPL=Frosted Lens w/Uplight (2), (5) CL=Clear Acrylic Lens & Door Frame (2), (5) ASY=Asymmetric Directional Louver (2), (5) WG=Heavy Duty Wireguard Distribution N=Narrow (2) W=Wide Mounting Arrangement Blank=Stand Alone R=Continuous Row Mount Packaging U=Unit Pack PAL=Palletized Out of Carton PALC=Palletized In Carton Options Emergency EL7W=Emergency Installed, 7 Watts (3), (4) EL14W=Emergency Installed, 14 Watts (3), (4) GTD2=Bodine Generator Transfer Device (8) ETS2=IOTA Emergency Transfer Switch (8) CCT L835=3500K L840=4000K L850=5000K LED Lumen Output 8 ft. 10=10,000 Lumens 14=14,000 Lumens 18=18,000 Lumens 22=22,000 Lumens 28=28,000 Lumens 32=32,000 Lumens (1, 7) 4 ft. 5=5,000 Lumens 7=7,000 Lumens 9=9,000 Lumens 11=11,000 Lumens 14=14,000 Lumens 16=16,000 Lumens (1, 7) Driver Type CD=0-10V Dimming (standard) SD=Step-dim Driver (7) 5LTD=Fifth Light DALI Number of Drivers 1=1 Driver (10,000 lumen) 2=2 Drivers (16,000, 14,000, 18,000 and 22,000 lumen) 4=4 Drivers (28,000 and 32,000 lumen) Accessories (order separately) ILED-SPM=Single Monopoint Hanger w/Hub FH-1=Fixture Hook FL-1=Fixture Loop SHK=Fixture Hook AYC-CHAIN/SET/U=(2) Hooks, 36" Chain Sets w/S-Hooks TOGGLE-=Single Toggle, #2 Cable (Specify 10' or 30') LOOP-=Loop Hanger, #2 Cable (Specify 10' or 30') MC6=6' Modular Power Cord MPC6=6' Modular Power Cord & Plug (Specify Voltage) MMS=360° or 180° Aisle Motion Sensor with Modular Power Receptacle (120-277V) MDS6=6' Modular Power Cord with MWS 27DS18/2G06MP Connector Door Frames (for Field Installation) (9) ILED-4-FRM/FL-PK=4 ft. Frosted Acrylic Lens & Frame ILED-4-FRM/CL-PK=4 ft. Clear Acrylic Lens & Frame ILED-4-WG-PK=4 ft. Wireguard ILED-4-TBW-PK=4 ft. Thin White Baffle ILED-4-ASY-PK=4 ft. Asymmetric Directional Louver NOTES: (1) Max. ambient 40C for 16K and 32K lumen packages. (2) Narrow distribution not available with FL, FL/UPL, CL and ASY shielding options. (3) Max. ambient 35C for EL options. (4) EL not available in 347 or 480V configurations. (5) Wireguard available in conjunction with shielding option (catalog example TWB/WG). (6) PI option does not include low voltage wiring for 0-10V dimming. (7) Step-dim not available in 16,000 and 32,000 lumen configurations. (8)Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. (9)8 ft. fixtures require two door frames per fixture. (10) DesignLights Consortium™ Qualified and classified for DLC Standard (all lumen packages), refer to www.designlights.org for details. Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. Motion Sensors MS=360° or 180° Motion Sensor, 120 through 347, or 480V MP=Modular Power Receptacle (Used for all Cord or Cord and Plug options) Wiring PI NG=Plug In System (1, 2, or 3 Circuit Capability), No Ground (ground provided by fixture body) (6) PI WG=Plug In System (1, 2, or 3 Circuit Capability), With Ground (separate ground wire in harness) (6) CPI NG=Crossover Plug In System (2 or 3 Circuit Capability) No Ground (ground provided by fixture body) (6) CPI WG=Crossover Plug In System (2 or 3 Circuit Capability) With Ground (separate ground wire in harness) (6) TILW=Tandem Inline Wiring MWS=Modular Wiring System Options ORDERING INFORMATION BLK=Black Hot PI1=Single Circuit NG=No Ground (ground provided by fixture body) WG=With Ground (separate ground wire in harness) PI1 - Single Circuit Plug-In SAMPLE NUMBER: PI1BLK-WG BLK=Black Hot BLU=Blue Hot PI2=Two Circuit NG=No Ground (ground provided by fixture body) WG=With Ground (separate ground wire in harness) PI2 - Two Circuit Plug-In SAMPLE NUMBER: PI2BLK-WG Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral Leave Blank=Single Neutral 2NEU=Two Neutrals BLK=Black Hot BLU=Blue Hot RED=Red Hot PI3=Three Circuit NG=No Ground (ground provided by fixture body) WG=With Ground (separate ground wire in harness) PI3 - Three Circuit Plug-In SAMPLE NUMBER: PI3BLK-WG Leave Blank=Single Neutral /WHT=White Neutral /GRY=Gray Neutral Leave Blank=Single Neutral 2NEU=Two Neutrals Specifications & dimensions subject to change without notice. Consult your Eaton Representative for availability and ordering information. Catalog Circuit Number Number of Wired To Suffix Circuits Ballast PI 1 BLK 1 Black PI 2 BLU 2 Blue PI 2 BLK 2 Black PI 3 RED 3 Red PI 3 BLU 3 Blue PI 3 BLK 3 Black Catalog Numbering System The PI System is available in sections up to 8' in length for continuous row wiring by simply plugging the sections together. Each PI section is factory wired to the ballast leads. Color coding of wires is as follows: PI-1 = One Circuit - 2 Wires: one black, one white PI-2 = Two Circuits - 3 Wires: one black, one blue, one white PI-3 = Three Circuits - 4 wires: one black, one blue, one red, one white When ordering the PI2/PI3 System it is necessary to specify the number of fixtures required for each circuit. Each circuit in fixture must be ordered as a separate line item, with a different hot wire color specified. All wiring to external feeds, using cord or cord & plug, are responsibility of installing licensed contractor. Cord and cord & plug sets must be ordered separately if PI option is chosen. PI OPTION ORDERING INFORMATION PS519040EN 2016-06-17 11:22:38 Catalog No. Wt. 4ILEDL 15 lbs. 8ILED 30 lbs. SHIPPING DATA INDUSTRIAL BAY LED HALO LED H4 Series - 2nd Generation The Halo H4 LED is a family of 4” aperture recessed downlight H457 series of housings designed for exclusive use with Halo EL406, ELG406, ELSG406 Series LED Light Engines and compatible 4” TL4 and TLS4 LED trims. Halo H4 LED housings have integral LED drivers that offer dimming as a standard feature. This is an insulated ceiling* AIR-TITETM housing offering 120 volt dimming capability. The H4 LED series offers high quality down- lighting along with high efficacy – the result being great lighting and significant energy savings. MECHANICAL Housings • Enclosure of formed aluminum construction. • Openings are gasketed AIR-TITE. • Designed for insulated ceilings in direct contact with insulation.* (May also be installed in non-insulated ceilings.) Plaster Frame • Galvanized steel die-formed construction. • The collar can be removed from plaster frame to provide access to the junction box. • Collar adjusts for ceilings up to 1-1/2” thick. • Plaster frame features include: - Patented regressed locking screw positioned for securing hanger bars from below the ceiling. - Cutouts for easily crimping hanger bars in position. - AIR-TITE aperture gasket is pre-installed. - HALO identity embossed on plaster frame. GOT NAIL! Pass -N-Thru™ Bar Hangers • Pre-installed nail easily installs in regular lumber, engineered lumber and laminated beams. • Safety and guidance system prevents snagging, ensures smooth straight nail penetration and allows bar hangers to be easily removed if necessary. • Automatic leveling flange aligns the housing and lets you hold the housing in place with one hand while driving nails. • Housing can be positioned at any point within 24” joist span. • Pass-N-Thru™ feature allows bar hangers to be shortened without removing from plaster frame. • Score lines allow “tooless” shortening for 12” joists. • Bar hangers may be repositioned 90°. • Integral T-bar clip snaps onto T-bars - no additional clips required. Slide-N-Side™ Junction Box • Positioned to accommodate straight conduit runs • Seven 1/2” trade size conduit knockouts with true pry-out slots • Slide-N-Side™ wire traps allow non-metallic sheathed cable to be installed without tools and without removing knockouts. • Accepts a wide range of non-metallic (type NM) sheathed cables - the standard cable types used in lighting in both U.S. and Canada. - Allows wiring connections to be made outside the junction box - Simply insert the cable directly into the trap after connections are made. - Accommodates the following standard non-metallic sheathed cable sizes: (US) #14/2, #14/3, #12/2, #12/3 (Canada) #14/2, #14/3, #12/2 LED Light Engine Connection • LED connector is a non-screw base connector offering easy installation with the H4 LED 2nd Generation EL406, ELG406, ELSG406 Series LED Light Engines. • LED connector meets high-efficacy luminaire requirement for a non-screw base socket, and where required to qualify as a high- efficacy luminaire. (California Title-24) LED Driver • LED dimmable driver mounts to the housing. • Driver is a120 Volt, high efficiency, electronic power supply providing low voltage power to EL Series LED Light Engines. • Driver meets FCC EMI/RFI Consumer Level limits for use in residential and commercial installations. • Driver features high power factor and low THD and has integral thermal protection in the event of over temperature or internal failure. • Driver is specifically designed for compatibility with EL406 LED Light Engines, and ELG406, ELSG406 Adjustable Gimbal Light Engine / Trims. • If dimming is not required the fixture can be operated from a standard wall switch. Dimming • The HALO H4 LED luminaire is designed for dimming capability to 10% in normal operation with most 120V leading edge (LE) and trailing edge (TE) phase control dimmers. H4 LED may also dim to 5% using dimmers with low end trim adjustment. (Consult dimmer manufacturer for application/compatibility/ loading. Note, some dimmers require a neutral in the wallbox). Warranty Cooper Lighting provides a five year limited warranty on Halo LED Luminaires which includes the LED Recessed Housing, LED Light Engine, and LED trims. Labels • UL/cUL Listed 1598 Luminaire • UL/cUL Listed for Damp Location • UL/cUL Listed for Wet Location, covered ceiling - with select trims • UL/cUL listed for Direct Contact with insulation and combustible material* Qualifications • Use with designated LED light engines and trims for ENERGY STAR® qualification.** • Can be used for State of California Title 24 high efficacy luminaire compliance** • Can be used for Washington State Energy Code (WSEC) and International Energy Conservaction Code (IECC) high efficacy luminaire compliance IC and AIR-TITE™ Certified under ASTM-E283 and listed UL/cUL 1598. May be used to meet insulated ceiling and restricted air-flow requirements such as: • Washington State Energy Code (WSEC) • International Energy Conservation Code (IECC) • New York State Energy Conservation Construction Code (NY-ECCC) • State of California Title 24 “Recessed Luminaires in Insulated Ceilings.” DESIGN FEATURES H457ICAT1E 4-Inch LED Recessed Housing New Construction Insulated Ceiling High Efficacy LED Housing- Dimmable H4 Series LED Energy Data: (Values at non-dimming line voltage.) Minimum Starting Temp: -30°C (-22°F) EMI/RFI: FCC Title 47 CFR, Part 18 (Consumer) Sound Rating: Class A standards Input Voltage: 120V Power Factor: >0.90 Input Frequency: 50/60Hz THD: <20% Input Power: 13W Input Current: 121mA Driver Compliance: UL6950, LPS rated Maximum IC (Insulated Ceiling) Ambient Continuous Operating Room Temperature: 25°C (77°F) Maximum Non-IC (Non-Insulated Ceiling) Ambient Continuous Operating Room Temperature: 40°C (104°F) www.cooperlighting.com ADV131740 December 16, 2013 10:36 AM FOR USE IN INSULATED CEILINGS FOR DIRECT CONTACT WITH INSULATION* ALSO SUITABLE FOR NON-IC APPLICATIONS Catalog # Project Comments Prepared by Type Date HALO® *Not for use with housings in direct contact with spray foam insulation. **Refer to ENERGY STAR® Qualified Products List and CEC (T24) Appliance Database for listings. DIMENSIONS H457ICAT1EHALO® 1/2 inch (13 mm) 8-1/2 inch (216 mm) 6 inch (152 mm)5-3/8 inch (136 mm) outer dimension 4-1/4 inch (108 mm) ORDERING INFORMATION - H4 LED Downlights SAMPLE NUMBER: H457ICAT1E - EL406927 - TL410SC Complete unit includes LED housing, light engine and trim; ordered separately. H4 LED Housing H4 LED Light Engine EL406 CRI CCT H457 = 4˝ housing H4 LED series downlight, 2nd Generation ICAT = New Construction Insulated Ceiling, AIR-TITE 1E = LED driver, 120V, 50/60 Hz, dimmable, LE/TE* phase control dimmers (refer to dimmer manufacturer). EL406 = 4" LED Downlight Engine, 2nd Generation 9 = 90 CRI 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K Trim Options Accessories TL410SC = Specular Clear Reflector, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL410H = Haze Reflector, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL410WH = White Reflector, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL410SN = Satin Nickel Reflector, Diffuse Polymer Dome Lens, Satin Nickel Ring, Shower Rated TL410TBZ = Tuscan Bronze Reflector, Diffuse Polymer Dome Lens, Tuscan Bronze Ring, Shower Rated TL410SBK = Specular Black Reflector, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL411WB = White Baffle, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL411BB = Black Baffle, Diffuse Polymer Dome Lens, White Ring, Shower Rated TL402SCS = Specular Clear Reflector, Solite® Glass Lens, and White Ring, Shower Rated TL402HS = Haze Reflector, Solite® Glass Lens, and White Ring, Shower Rated TL402WHS = White Reflector, Solite® Glass Lens, and White Ring, Shower Rated TL402SNS = Satin Nickel Reflector, Solite® Glass Lens, and Satin Nickel Ring, Shower Rated TL402TBZS = Tuscan Bronze Reflector, Solite® Glass Lens, and Tuscan Bronze Ring, Shower Rated TL402SBKS = Specular Black Reflector, Solite® Glass Lens, and White Ring, Shower Rated TL403WBS = White Baffle, Solite® Glass Lens, and White Ring, Shower Rated TL403BBS = Black Baffle, Solite® Glass Lens, and White Ring, Shower Rated TLS408WHWB = Square Baffle Trim, Solite® Glass Lens, White Ring with White Baffle, Shower Rated TLS408WHBB = Square Baffle Trim, Solite® Glass Lens, White Ring with Black Baffle, Shower Rated TLS408SNBB = Square Baffle Trim, Solite® Glass Lens, Satin Nickel Ring with Black Baffle, Shower Rated TLS408TBZBB = Square Baffle Trim, Solite® Glass Lens, Tus- can Bronze Ring with Black Baffle, Shower Rated TL409WW = Wall Wash, Semi-Specular Clear Reflector with White Ring, Shower Rated TL409WHWW = Wall Wash, White Reflector with White Ring, Shower Rated TL422PS = Polymer “Dead Front” White Baffle & Regressed Lens, White Ring, Shower Rated Thin Profile Designer Trim Rings For use with Round TL4 trims (not compatible with Square TLS4 trims, or adjustable gimbals ELG, ELSG trims.) TRM400WH = White TRM400BK = Black TRM400SN = Satin Nickel TRM400TBZ = Tuscan Bronze TRM400PC = Polished Chrome * LE = Leading Edge (forward phase control) dimming * TE = Trailing Edge (reverse phase control) dimming ORDERING INFORMATION - H4 LED Adjustable Gimbals SAMPLE NUMBER: H457ICAT1E - ELG406930WH Complete unit includes LED housing, light engine and trim; ordered separately. H4 LED Light Engine Optional Accessory Reflector Kit Optional Len Media CRI CCT Finish (order separately)(order separately) ELG406 = Round LED Adjustable Gimbal Light Engine - 2nd Generation ELSG406 = Square LED Adjustable Gimbal Light Engine - 2nd Generation 9 = 90 CRI 27 = 2700K 30 = 3000K 35 = 3500K 40 = 4000K WH = White SN = Satin Nickel TBZ = Tuscan Bronze TL412RK includes: • 25° reflector (one is included with gimbal) • 35° reflector • 50° reflector TL412RK is for use with ELGxx and ELSGxx gimbals only. One lens media may be used in place of clear lens. Optical Lenses • L110 Diffuse Sand Blasted Lens • L111 Soft Focus Textured Lens • L113 Prismatic Lens • L115 Linear Spread Lens Dichroic Color Films • L114 UV Filter • L120 Red • L121 Amber • L122 Yellow • L123 Green • L124 Daylight • L125 Blue • L127 Cosmetic Color Filters • L130 Yellow www.cooperlighting.com Note: Specifications and Dimensions subject to change without notice. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770 486.4801 Cooper Lighting 5925 McLaughlin Rd. Mississauga, Ontario, Canada L5R 1B8 905.507.4000 FAX 905.568.7049 Solite® is a registered trademark of AGC Flat Glass North America