HomeMy WebLinkAboutFile Documents.100 E Main St.0040.2016 (16).ACBKCD -1 CODE DRAWING
D-1 DEMOLITION FLOOR PLAN
D-2 FLOOR CUTTING PLAN
14-1 FLOOR PLAN
A-2 REFLECTED CEILING PLAN
A-3 ENLARGED PLANS 4 INT. ELEVATIONS
A-4 SCHEDULES, NOTES s DETAILS
P-1 PLUMBING LEGEND, SCHEDULES # NOTES
P-2 FIRST FLOOR PLAN -SANITARY WASTE
P-3 FIRST FLOOR PLAN- DOMESTIC WATER
P-4 PLUMBING DETAILS
P-5 PLUMBING RISER DIAGRAM
P-ro PLUMBING SPECIFICATIONS
M-1 MECHANICAL SPECIFICATIONS
M-2 FIRST FLOOR PLAN- MECHANICAL
M-3 FIRST FLOOR PLAN- MECHANICAL PIPING
M-4 MECHANICAL DETAILS
M-5 MECHANICAL SCHEDULES
1`1-5 MECHANICAL CONTROLS
E-1 ELECTRICAL COVER SHEET
E-2 FIRST FLOOR PLAN- LIGHTING
E-3 FIRST FLOOR PLAN- POWER 8 SPECIAL SYSTEMS
E-4 FIRST FLOOR PLAN- MECHANICAL CONNECTIONS
E-5 PANEL BOARD SCHEDULES 4
ONE -LINE RISER DIAGRAM
THE FOLLOWINn DRAWIN65 ARE INCLUDED FOR REFERENCE
QO.1 COVER SHEET
DR. JOHN MILLER QU DENTAL EQUIPMENT PLAN
Q2.1 DENTAL CARPENTRY PLAN
Q2.2 DENTAL CARPENTRY DETAILS
Dental Office Tenant Flt Out Q3.1 DENTAL ELECTRICAL PLAN
03.2 DENTAL ELECTRICAL DETAILS
04.1 DENTAL PLUMBING PLAN
100 East Main Street 042 DENTAL PLUMBING DETAILS
05.1 INTERIORS PLAN
Aspen, C 81611 Q52 INTERIORS SCHEDULES
JUNE 20, 2016
Benco Dental
295 CenterPoint Blvd.
Pittston, Pennsylvania 18640
/DClark
0:1
00 Ballina
6-20-16 DESIGN GROUP, LLC
CONTACT:
JORDAN Cs, CLARK
5-10-815-3242
1610 ADAMS AVENUE
DUNMORE, PA 18509
PHONE: 570-207-0195
FAX: 570-207-0198
Z-03
EXTERIOR FEATURESASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
8/31/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16
PINK SET 8/31/16
1744
PORTO-I
Width:4.25"
Height:9.5"
Extension:6"
Glass:Clear Acrylic
CFL:1 x 13WT2 (GU24) Twist Lock (self
ballast bulb Included) (OPTIONAL)
Lamp:1 x 60W - 120V - A19 (not included)
Finish:Architectural Silver
Notes:Suitable for Wet locations.
contemporary elegance
PLC Lighting Inc.
9667 Owensmouth Avenue, Unit 201, Chatsworth, CA 91311
Phone: (888) 357-4040 (Outside California) (818) 349-1600 Fax: (818) 280-0909 (818) 407-0100
www.plclighting.com W60W59D42T03T04T06T05T01T02A
1
4
6
2
3
5
10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10"
3'-2 1/2"10"19'-8"3'-2 1/2"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"NON-UNIT
ELEVATOR.
SYMMETRY
LU/LA
SHADING
INDICATES ONE
HOUR FIRE
SEPARATION,
SEE A 5.1
REMOVE AND FILL
IN WITH BRICK TO
MATCH EXTERIOR
RECYCLE:
4 TOTERS
TRASH:
2 TOTERS
NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER
ELEVATOR
ELECT.
PNL.
TRASH: 4
TOTERS
ELECT.
METER
6"2'-5 3/4"NEW CONCRETE CURB
NEW STEEL1X2
BAR STOCK POST
AT HANDRAIL
NEW STEEL 1X2
BAR STOCK
HANDRAIL
0 3/4"11 1/4"1'0 3/4"3'1" X 2" WELDED STEEL BAR
STOCK POSTS / HANDRAIL
LESS THAN 30" TO GRADE
AT ALL LANDSCAPE STAIR
LOCATIONS
RISE AND RUN VARY: SEE
CIVIL DRAWINGS
STEP LIGHTS TYP.
#1200WR-VISION3-0SQH1-00SA
Vision 3 Wall Recessed
Shown in: Satin Aluminum
Description:Description:Description:Description:
Vision 3 square wall / floor recessed fixture is perfect for
furniture, and wall applications. The fixture features a
scoop reflector and a silver finish. The Vision 3 kit
includes the fixture, housing, plaster screen, electronic
transformer and one 20 watt, 12 volt, JC, G4 halogen
lamp. General light distribution. ETL listed.
List Price:List Price:List Price:List Price:$242.00
Our Price:Our Price:Our Price:Our Price:$193.60
Shade Color:Shade Color:Shade Color:Shade Color:N/A
Body Finish:Body Finish:Body Finish:Body Finish:Satin Aluminum
Lamp:Lamp:Lamp:Lamp:1 x JC/G4 (bipin)/20W/12V
Wattage:Wattage:Wattage:Wattage:20W
Dimmer:Dimmer:Dimmer:Dimmer:Low Voltage Electronic
Dimensions:Dimensions:Dimensions:Dimensions:3.5"H x 3.5"W x 3"D
Product Number:('*
Company:Company:Company:Company:Fixture Type:Fixture Type:Fixture Type:Fixture Type:Date:Date:Date:Date:Jul 09, 2014Jul 09, 2014Jul 09, 2014Jul 09, 2014
Project:Project:Project:Project:Approved By:Approved By:Approved By:Approved By:www.Lightology.comwww.Lightology.comwww.Lightology.comwww.Lightology.comAddress: Address: Address: Address: Phone: Phone: Phone: Phone: Fax: Fax: Fax: Fax: 1718 W. Fullerton Ave. Chicago IL 60614 866-954-4489(773) 883-6131SCALE: 1/4" = 1'-0"
TRASH
SCALE: 1" = 1'-0"
TYP. RAIL AT RAMP
SCALE: 1" = 1'-0"
TYPICAL LANDSCAPE STEP DETAIL
LIGHT FIXTURES
FIXTURE L FIXTURE V
FIXTURE P
AT PRESENT THE WASTE SERVICE
REMOVES TWO 96-GAL "TOTERS" THREE
TIMES PER WEEK. ONE IS TRASH, ONE IS
RECYCLE
Received
2/22/2016 11:43:25 AM
NET-1
NET LIVABLE/ LEASABLEASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
10/3/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16
PINK SET 8/31/16
NON-UNIT EXTERIOR STAIR
52 S.F. (NET EXEMPT)
COMMERCIAL STORAGE
209 S.F. + 252 S.F. = 461 S.F.
GENERAL BUILDING MECHANICAL
(INCL. ELEV. MECH)77+19=96 S.F.
(NET EXEMPT)
NON-UNIT INTERIOR HALL
134 S.F.
NON-UNIT EXTERIOR STAIR
41 S.F. (NET EXEMPT)
NON-UNIT EXTERIOR ELEVATOR
45 S.F.
ENTRY LOBBY
344 S.F.
RESIDENTIAL STAIR
80 S.F.
COMMERCIAL NET LEASABLE
(1285+1006+1205)
3496 S.F.
MAIN LEVEL NET
LIVABLE / LEASABLE
569+ 777+ 2150
UPPER LEVEL NET
LIVABLE / LEASABLE
NON-UNIT EXTERIOR BALCONY/STAIR
131 S.F. (NET EXEMPT)
NON-UNIT EXTERIOR ELEVATOR
45 S.F. (NET EXEMPT)
COMMERCIAL NET LEASABLE
532 S.F.
FREE-MARKET RESIDENTIAL LIVABLE
2420 S.F.
UPPER LEVEL NET
LIVABLE / LEASABLE CDWDW
FFD02
D15
D20 D22D19D14D06D10
D16
D09D12W24
GLASS ENCL.
WIRE SYSTEM
WINE RACK
OVER WINE
CHILLER
PD LIGHT
WASHES TILE
WALL AND
PERIMETER OF
WINE ENCLOSURE
EXISTING
WOODBURNING
FIREPLACE
IN EXISTING
CHASE 1234567891011121314W22W23W24W26 W27 W28 W29 W30 W31 W15D05W06W07W05W12D01W17 W16W20W18
ED23D03D112,420 sq ft
1
2
3
412345678A
A
E
E
F
F
B
B
C
C
D
D6'-4"8'-1/2"
2'-1 1/2"
532 sq ft
RECESS SHADE POCKET
AT LIFT-N-SLIDE
switch D17D24
RESIDENTIAL
COMMERCIAL
HER CLOSET
EXIT
ELEVATOR
KITCHENMUD ROOM
LAUNDRY PANTRY
HIS BEDROOM HIS BATH
HER BATH MECH CHASEMontigo RP424PFN
GAS APPLIANCE
ELECT.
PNL.
ELECT.
PNL.
MECHCHASE
PITCH
1/8"/FT.
IRONING
BOARD
PROVIDE
OUTLET
RETRACT.
C'LINE
NICHE
A/V
POWERVENT
sconces
SHELVESE.T.
E.T.
E.T. ABOVE
E.T. ABOVE
W08W09W10W11
W04W03W02W01D04D08476 sq ft
131 sq ft
RAIL EXTENDS TO WALL
RAIL RETURN, SEE A 7.2
TRACK FOR
LADDER
TRACK FOR
LADDER
switch
pendantpendant
DINING ROOM
LIVING ROOM
HIS CLOS.
OFFICE.ENTRY
POWDER
HALL
HBD35D411234567891011121234567891011121314
W60W59D42W40 W41D31 W42W44W43D32D34D33W62T03T04T06T05T01W67 W64 W65 W66W61
W32W33W34W35
T021
2
3
412345678A
A
E
E
F
F
B
B
C
C
D
D10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10"17'-4 1/2"10"9'-1/4"10'-5 1/4"7'-1 1/4"6 3/4"7'-4 3/4"6 3/4"25'-8 1/2"10"
80'-8"
3'-2 1/2"10"17'-4 1/2"10"9'-1 1/2"4"18'-8"4"14'7 1/2"8'-2"7 1/4"3'-9 1/2"7 3/4"3'-9 1/2"1'-1/4"
5 1/2"6'-10 3/4"10"4'-1 1/2"5 1/2"7'-5 1/4"8"4'-11 3/4"
1'-11"19'-8"17'-4 1/4"10"9'-1 3/4"4"18'-8"4"13'-9"10"
3'-11 1/2"6'-7"4'-5 1/4"9 1/2"12'-1"5 1/2"5'-6"3 1/2"5'-7"5 1/2"26'-1/4"3'-2 1/2"
1'
5"17'11 3/4"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"18'-5 3/4"14'-4"13'-6"15'-4 1/4"18'-5 1/2"9'-5 3/4"13'-2 1/4"5'-2 1/2"15'-1 1/2"5'-3 1/2"13'-2"7'-7 1/4"
17'-2 1/4"2'-2"6'-10 3/4"3 1/2"3'-1"5 1/2"6'-10 3/4"
5 1/2"
11'11'-9 3/4"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"11'-10 1/4"8"4'-6 1/2"8"5'-11 1/4"3'-11 1/2"5 1/2"5 1/2"6'-10 3/4"17'-1"60'-3"23'-8 1/4"569 sq ft 777 sq ft
2150 sq ft
45 sq ft
1-HOUR RATED MECH CHASE
(SEE WALL ASSEMBLY "A" ON
THIS PAGE)
FILL INDICATES 1-HOUR RATED
MECH CHASE AND WALLS
BETWEEN OFFICES (SEE WALL
ASSEMBLY "A" ON THIS PAGE)
FILL INDICATES 1-HOUR RATED
MECH CHASE AND WALLS
BETWEEN OFFICES (SEE WALL
ASSEMBLY "A" ON THIS PAGE)
FILL INDICATES 1-HOUR
RATED WALLS
BETWEEN OFFICES (SEE
WALL ASSEMBLY "A"
ON THIS PAGE)
REMOVE AND FILL
IN WITH BRICK TO
MATCH EXTERIOR
ACCESSIBLE
MEN
ACCESSIBLE
WOMEN
ENTRY PATIO
AT GRADE
up
NON-UNIT LOBBY
EXISTING RAMP
TO BE REMOVEDWINDOW UNITRECYCLE:
4 TOTERS
EXISTING PLANTER TO
BE RESIDED- SEE SITE
PLAN
TRASH:
2 TOTERS
GAS
METER
COMMERCIAL COMMERCIAL
COMMERCIAL
DRINKING
FOUNTAIN TO
COMPLY W/ ICC
117.1 SEC 602NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER
ELEVATOR
STRUCTURAL WALL TO REMAIN
STRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAIN
WAITING ROOM
MECH /
STOR
MECH CHASENO DROP CEILING
NO DROP CEILING
DROP CEILING
DROP CEILING
WALL
MECH
CHASE
ELECT.
PNL.
ELECT.
PNL.ELECT.
PNL.
TRASH: 4
TOTERS
HB
HB
W46EW45W46DW46CW46BW46AW52 W51 W49 W48
D40
W55 W54
9'-3"5 1/2"7'-6"2"11 3/4"2'-1 1/4"4'-1 1/2"5'
5'
337 sq ft
81 sq ft
RAIL EXTENSION BOTH SIDES
CUT BACK PLANTER
TO ALLOW POURING
OF NEW FOOTINGS
ELECT.
METER
P
HBD51
D51D54 D56D52 D55D5317'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4"
14'-6"8"
8'5'-6"
4'-10"3 1/2"4'-7"
1'1'9'-1 1/4"3 1/2"77 sq ft
19 sq ft
EXISTING DOOR LOCATION
EXISTING EGRESS DOOR
EXISTING EXTERIOR STAIR TO REMAIN
PROPOSED LADDER
RAIL DIES INTO DOOR WALL AT MAIN
LEVEL. 1' EXTENSION DOES NOT OCCUR
AT LOWER LEVEL DOOR
NON-
UNIT
MECH
2% of 7475
s.f. mech as
required = 150
s.f.
NON-UNIT EXTERIOR STAIR
52 S.F. (NET EXEMPT)
COMMERCIAL STORAGE
209 S.F. + 252 S.F. = 461 S.F.
GENERAL BUILDING MECHANICAL
(INCL. ELEV. MECH)77+19=96 S.F.
(NET EXEMPT)
NON-UNIT INTERIOR HALL
134 S.F.
COMMERCIAL
STORAGE 3
NON-UNIT
HALL
COMMERCIAL
STORAGE 1
ELEV.
MECH.
SELF-CLOSING
DOOR
TENANT FINISH
TENANT FINISH
CEILING TO BE 1-HOUR
FIRE RATED (TYP)
EXIT
COMMON
ELECT.
PNL.
COMMERCIAL
STORAGE 2
TENANT FINISH
252 sq ft
96 sq ft
134 sq ft
113 sq ft
TOTAL NET LEASABLE-
COMMERCIAL
3496+528+461= 4485 S.F.
TOTAL NET LIVABLE-
RESIDENTIAL
2419+80= 2499 S.F.
TOTAL NON-UNIT INTERIOR
SPACE
TOTAL NON-UNIT DECKS /
EXTERIOR SPACE (EXEMPT)
29+344+45+134+96 = 648 S.F.
120+41+45+52 = 258 S.F.
TOTAL NET LIVABLE+ NET LEASABLE
=6984 S.F.
PERCENT NET LEASABLE OF TOTAL
4485/6984 S.F. = 64%
PERCENT NET LIVABLE OF TOTAL
2499/6936 S.F. = 36%
26.575.020.D.14 Allocation of non-
unit space in a mixed use building.
Received
2/22/2016 11:43:25 AM
NET-1
NET LIVABLE/ LEASABLEASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
8/9/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16
NON-UNIT EXTERIOR STAIR
52 S.F. (NET EXEMPT)
COMMERCIAL STORAGE
209 S.F. + 252 S.F. = 461 S.F.
GENERAL BUILDING MECHANICAL
(INCL. ELEV. MECH)77+19=96 S.F.
(NET EXEMPT)
NON-UNIT INTERIOR HALL
134 S.F.
NON-UNIT EXTERIOR STAIR
41 S.F. (NET EXEMPT)
NON-UNIT EXTERIOR ELEVATOR
45 S.F.
ENTRY LOBBY
344 S.F.
RESIDENTIAL STAIR
80 S.F.
COMMERCIAL NET LEASABLE
(1285+1006+1205)
3496 S.F.
MAIN LEVEL NET
LIVABLE / LEASABLE
569+ 777+ 2150
UPPER LEVEL NET
LIVABLE / LEASABLE
NON-UNIT EXTERIOR BALCONY/STAIR
131 S.F. (NET EXEMPT)
NON-UNIT EXTERIOR ELEVATOR
45 S.F. (NET EXEMPT)
COMMERCIAL NET LEASABLE
532 S.F.
FREE-MARKET RESIDENTIAL LIVABLE
2420 S.F.
UPPER LEVEL NET
LIVABLE / LEASABLE CDWDW
FFD02
D15
D20 D22D19D14D06D10
D16
D09D12W24
GLASS ENCL.
WIRE SYSTEM
WINE RACK
OVER WINE
CHILLER
PD LIGHT
WASHES TILE
WALL AND
PERIMETER OF
WINE ENCLOSURE
EXISTING
WOODBURNING
FIREPLACE
IN EXISTING
CHASE 1234567891011121314W22W23W24W26 W27 W28 W29 W30 W31 W15D05W06W07W05W12D01W17 W16W20W18
ED03D112,420 sq ft
1
2
3
412345678A
A
E
E
F
F
B
B
C
C
D
D6'-4"8'-1/2"
2'-1 1/2"
532 sq ft
RECESS SHADE POCKET
AT LIFT-N-SLIDE
RESIDENTIAL
COMMERCIAL
HER CLOSET
EXIT
ELEVATOR
KITCHENMUD ROOM
LAUNDRY PANTRY
HIS BEDROOM HIS BATH
HER BATH MECH CHASEMontigo RP424PFN
GAS APPLIANCE
ELECT.
PNL.
ELECT.
PNL.
MECHCHASE
PITCH
1/8"/FT.
IRONING
BOARD
PROVIDE
OUTLET
RETRACT.
C'LINE
NICHE
A/V
POWERVENT
sconces
SHELVESE.T.
E.T.
E.T. ABOVE
E.T. ABOVE
W08W09W10W11
W04W03W02W01D04D08476 sq ft
131 sq ft
RAIL EXTENDS TO WALL
RAIL RETURN, SEE A 7.2
TRACK FOR
LADDER
TRACK FOR
LADDER
DINING ROOM
LIVING ROOM
HIS CLOS.
OFFICE.ENTRY
POWDER
HALL
D35D411234567891011121234567891011121314
W60W59D42W40 W41D31 W42W44W43D32D34D33W62T03T04T06T05T01W67 W64 W65 W66W61
W32W33W34W35
T021
2
3
412345678A
A
E
E
F
F
B
B
C
C
D
D10"12'8"5'-3"19'-8 3/4"1'-1/4"13'-2"52'-8"10"17'-4 1/2"10"9'-1/4"10'-5 1/4"7'-1 1/4"6 3/4"7'-4 3/4"6 3/4"25'-8 1/2"10"
80'-8"
3'-2 1/2"10"17'-4 1/2"10"9'-1 1/2"4"18'-8"4"14'7 1/2"8'-2"7 1/4"3'-9 1/2"7 3/4"3'-9 1/2"1'-1/4"
5 1/2"6'-10 3/4"10"4'-1 1/2"5 1/2"7'-5 1/4"8"4'-11 3/4"
1'-11"19'-8"17'-4 1/4"10"9'-1 3/4"4"18'-8"4"13'-9"10"
3'-11 1/2"6'-7"4'-5 1/4"9 1/2"12'-1"5 1/2"5'-6"3 1/2"5'-7"5 1/2"26'-1/4"3'-2 1/2"
1'
5"17'11 3/4"10"17'-7"15'-1 1/2"5'-5 1/2"6'-1 1/4"6'-2 3/4"8"18'-5 3/4"14'-4"13'-6"15'-4 1/4"18'-5 1/2"9'-5 3/4"13'-2 1/4"5'-2 1/2"15'-1 1/2"5'-3 1/2"13'-2"7'-7 1/4"
17'-2 1/4"2'-2"6'-10 3/4"3 1/2"3'-1"5 1/2"6'-10 3/4"
5 1/2"
11'11'-9 3/4"2"9'-10 1/2"5 1/2"6'-9"6'-7 1/4"11'-10 1/4"8"4'-6 1/2"8"5'-11 1/4"3'-11 1/2"5 1/2"5 1/2"6'-10 3/4"17'-1"60'-3"23'-8 1/4"569 sq ft 777 sq ft
2150 sq ft
45 sq ft
1-HOUR RATED MECH CHASE
(SEE WALL ASSEMBLY "A" ON
THIS PAGE)
FILL INDICATES 1-HOUR RATED
MECH CHASE AND WALLS
BETWEEN OFFICES (SEE WALL
ASSEMBLY "A" ON THIS PAGE)
FILL INDICATES 1-HOUR RATED
MECH CHASE AND WALLS
BETWEEN OFFICES (SEE WALL
ASSEMBLY "A" ON THIS PAGE)
FILL INDICATES 1-HOUR
RATED WALLS
BETWEEN OFFICES (SEE
WALL ASSEMBLY "A"
ON THIS PAGE)
REMOVE AND FILL
IN WITH BRICK TO
MATCH EXTERIOR
ACCESSIBLE
MEN
ACCESSIBLE
WOMEN
ENTRY PATIO
AT GRADE
up
NON-UNIT LOBBY
EXISTING RAMP
TO BE REMOVEDWINDOW UNITRECYCLE:
4 TOTERS
EXISTING PLANTER TO
BE RESIDED- SEE SITE
PLAN
TRASH:
2 TOTERS
GAS
METER
COMMERCIAL COMMERCIAL
COMMERCIAL
DRINKING
FOUNTAIN TO
COMPLY W/ ICC
117.1 SEC 602NEW 4' WIDE HEATEDSIDEWALK LEVEL WITHALLEY- 273 SFENTER
ELEVATOR
STRUCTURAL WALL TO REMAIN
STRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAINSTRUCTURAL WALL TO REMAIN
WAITING ROOM
MECH /
STOR
MECH CHASENO DROP CEILING
NO DROP CEILING
DROP CEILING
DROP CEILING
WALL
MECH
CHASE
ELECT.
PNL.
ELECT.
PNL.ELECT.
PNL.
TRASH: 4
TOTERS W46EW45W46DW46CW46BW46AW52 W51 W49 W48
D40
W55 W54
9'-3"5 1/2"7'-6"2"11 3/4"2'-1 1/4"4'-1 1/2"5'
5'
337 sq ft
81 sq ft
RAIL EXTENSION BOTH SIDES
CUT BACK PLANTER
TO ALLOW POURING
OF NEW FOOTINGS
ELECT.
METER
P
D51
D51D54 D56D52 D55D5317'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4"
14'-6"8"
8'5'-6"
4'-10"3 1/2"4'-7"
1'1'9'-1 1/4"3 1/2"77 sq ft
19 sq ft
EXISTING DOOR LOCATION
EXISTING EGRESS DOOR
EXISTING EXTERIOR STAIR TO REMAIN
PROPOSED LADDER
RAIL DIES INTO DOOR WALL AT MAIN
LEVEL. 1' EXTENSION DOES NOT OCCUR
AT LOWER LEVEL DOOR
NON-
UNIT
MECH
2% of 7475
s.f. mech as
required = 150
s.f.
NON-UNIT EXTERIOR STAIR
52 S.F. (NET EXEMPT)
COMMERCIAL STORAGE
209 S.F. + 252 S.F. = 461 S.F.
GENERAL BUILDING MECHANICAL
(INCL. ELEV. MECH)77+19=96 S.F.
(NET EXEMPT)
NON-UNIT INTERIOR HALL
134 S.F.
COMMERCIAL
STORAGE 3
NON-UNIT
HALL
COMMERCIAL
STORAGE 1
ELEV.
MECH.
SELF-CLOSING
DOOR
TENANT FINISH
TENANT FINISH
CEILING TO BE 1-HOUR
FIRE RATED (TYP)
EXIT
COMMON
ELECT.
PNL.
COMMERCIAL
STORAGE 2
252 sq ft
209 sq ft
134 sq ft
TOTAL NET LEASABLE-
COMMERCIAL
3496+528+461= 4485 S.F.
TOTAL NET LIVABLE-
RESIDENTIAL
2419+80= 2499 S.F.
TOTAL NON-UNIT INTERIOR
SPACE
TOTAL NON-UNIT DECKS /
EXTERIOR SPACE (EXEMPT)
29+344+45+134+96 = 648 S.F.
120+41+45+52 = 258 S.F.
TOTAL NET LIVABLE+ NET LEASABLE
=6984 S.F.
PERCENT NET LEASABLE OF TOTAL
4485/6984 S.F. = 64%
PERCENT NET LIVABLE OF TOTAL
2499/6936 S.F. = 36%
26.575.020.D.14 Allocation of non-
unit space in a mixed use building.
Received
2/22/2016 11:43:26 AM
A 1.1
SITE PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
5/31/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
10'-2"4'5'
8"
8'-2 3/4"
8"2'-0"6"5'-0"6"9'8'-10 1/2"
8"
5'-0"2'-5 1/4"9'6'-8"16'-11 1/2"13'-8"273 sq ft
N 75°09'11"W 200.06'
N 75°09'11"W 270.08'
CITY MONUMENT SW CORNER BLOCK
66, HORIZONTAL CONTROL
S 75°09'11"E 70.02'N 14°50'49"E 110.00'E
G
EXISTING PLANTERS TO
BE REPAIRED OR REBUILT WITH
BOARD FORM CONCRETE
AND STEEL PANELS
TWO STORY BUILDING
WITH PARTIAL BASEMENT
42.0
80.080.052.0
3.6
CONC. WALKCONC. WALK
BACK OF CURB
6.4
1.81.8ENCROACHMENT LICENSERECEPTION NO. 410027EAST MAIN STREET
100.00' R.O.W. RECORD
ALLEY BLOCK 66
20.39' R.O.W. RECORD
NEW SLIP-RESISTANTPAVERS ATENTRY WALKEDGE OF PAVED STREET16.5'13.4'8.5' X 18'
PARKING SPACE
GARMISCH STREET101.00' R.O.W. RECORDPAVED DRIVECONC. WALK1"=10'
0 10 20
U.S. SURVEY FOOT USED
CERTIFICATION
DATED: _________,
THE UNDERSIGNED STATES THAT THE PROPERTY DESCRIBED HEREON WAS FIELD SURVEYED
DURING ______________, ____ AND IS ACCURATE BASED ON THE FIELD EVIDENCE AS
SHOWN, AND THAT THERE ARE NO DISCREPANCIES OF RECORD, BOUNDARY LINE CONFLICTS,
ENCROACHMENTS, EASEMENTS OR RIGHTS OF WAY IN FIELD EVIDENCE OR KNOWN TO ME
EXCEPT AS HEREON SHOWN. UNDERGROUND UTILITIES WITH NO ABOVEGROUND APPURTENANCES,
AND DOCUMENTS OF RECORD NOT SUPPLIED TO THE SURVEYOR ARE EXCEPTED. THIS SURVEY
IS VOID UNLESS WET STAMPED WITH THE SEAL OF THE SURVEYOR BELOW.
________________________________
JOHN M. HOWORTH, P.L.S. 25947
S 14°50'49"W 110.00'N 75°09'11"W 70.02'
CONC. WALK NEW FLAGSTONE WALKWAY TOSTAIRS & ELEVATORRED
25947
RED
25947 OVERHANGOVERHANGOVERHANG
REMOVE EXISTING CONC. WALK/RAMP, SEE CIVIL DRAWINGS
SHORTEN EXISTING PLANTER, USE WATER-PROOFING AT
BUILDING WALL, NEW PLANTER WALL
TO BE 4" CMU AND COVERED W/ STEEL
PLATE OR CONCRETE CONC.WALKDISK 25947 IN CONC.
15' INGRESS AND EGRESS
EASEMENT BOOK 202, PAGE 429
AND EASEMENT AGREEMENT
RECEPTION NO. 395469
(VACATED, SEE BOOK 194 AT PAGE 7)
OVERHANGEXISTINGWINDOW WELLW/ GRATEPLANTERRELOCATE EXISTING GAS LINE
& METER AND ELECTRIC
PLANTER
EXISTING PLANTER TO
BE RE-FACED WITH STEEL
TALL GRASSES AND FLOWER
GARDEN WITH BLACK PEBBLES DNUPEXISTING GAS AND ELECTRIC
METER TO BE RELOCATED
AROUND CORNER TO
ALLOW FOR NEW STAIRS / ELEVATOR
NEW SLIP-RESISTANT PAVER
WALKWAY ON GRADE TO NEW STAIR.
PAVERS TO COMPLY WITH
A117.1-2003/303 (TYP.)
PROPERTY LINE
EXISTING LANDSCAPING
BETWEEN BUILDINGS TO BE
MAINTAINED OR REVEGETATED
AS NEEDED AFTER CONSTRUCTION
GRAVEL
GRASS
EXISTING
CONCRETE PAD
TO BE
REMOVED
TALL GRASSES AND
FLOWER GARDEN WITH
BLACK PEBBLES
GRASS STEEL PLATE SIGN
FOR NEW MEDICAL
OFFICE
STEELPLATE SIGNFOR NEWMEDICALOFFICES
PROTECT
EXISTING TREES
PROTECT
EXISTING TREES
PROTECT
EXISTING TREES
PROTECT
EXISTING
TREES
RECYCLING ENCLOSURE,
STEEL PLATE IN FRAME
(MATCHES NEW
SIGNAGE FRAMES)
PAVERS FOR NEW
OFFICE ENTRY
4 PROPOSED
PARALLEL
PARKING SPOTS
PUBLIC BUS STOP
PROPOSED
GRASS
PROPOSED
GRASS
PROPOSED
GRASS
RAMP
CURB
FLAGSTONESTAIR W/HANDRAILBOTH SIDES4R@ 5 1/8", 3T@ 1'-0"
FOR DETAILED INFORMATION,
SEE PINNACLE ENGINEERING
DRAWINGS DATED 6-17-14
EXISTING WATER LINE TO REMAIN
RELOCATE FENCE TO WITHIN
PROPERTY BOUNDARY
PROTECT INSIDE TRASH
ENCLOSURE WITH
APERTURE AT METER
NOTE: CROSS-SLOPE ON ALL
EXTERIOR WALKWAYS SHALL NOT
EXCEED 1:48
RECYCLE
TRASH
ELEVATOR
NEW SLIP-RESISTANT HEATED PAVER
WALKWAY ON GRADE TO NEW ELEVATOR.
PAVERS TO COMPLY WITH
A117.1-2003/303 (TYP.)
EXISTING PARKING SPACE
TO BE PAVERS IN SAND WITH
4" CONCRETE BORDER
FLAGSTONEPATIO TO REMAINCENTERLINE OF NEW DOOR
AND WALKWAY
STEPS
DN
RAMP: SEE CIVIL
RAMP: SEE CIVILRAMP: SEE CIVIL
PROTECT
EXISTING
TREES
NEW RAMP W/
LANDINGS-
SEE CIVIL
SCALE: 1/8" = 1'-0"
CIVIL SITE PLAN
line of building
6' - 0"
yard box. snow
melt manifold
ELECTRIC
SERVICE AND
METERS
NEW GAS METER
NEW TELEPHONE AND TV
SERVICE ENTERS
BASEMENT
Received
2/22/2016 11:43:25 AM
A 2.1
LOWER LEVEL PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
5/31/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16123456789101112D51
D51D54 D56D52D55D53A
A
E
E
F
F
B
B
1 1
4 4
6 6
2 2
3 3
5 5
C
C
D
D17'-10 1/2"3 1/2"28'-4 1/2"3 1/2"4'-2"52'-8"3'-8 1/2"9'-8 1/2"3 1/2"4'-4"
14'-6"8"
8'5'-6"
4'-10"3 1/2"4'-7"
1'1'9'-1 1/4"3 1/2"EXISTING DOOR LOCATION
EXISTING EGRESS DOOR
EXISTING WATER LINE TO BE
CAPPED. INSTALL NEW LINE
FROM WEST SIDE OF BLDG.
EXISTING EXTERIOR STAIR TO REMAIN
PROPOSED LADDER
RAIL DIES INTO DOOR WALL AT MAIN
LEVEL. 1' EXTENSION DOES NOT OCCUR
AT LOWER LEVEL DOOR
NON-
UNIT
MECH
COMMERCIAL
STORAGE 3
NON-UNIT
HALL
COMMERCIAL
STORAGE 1
ELEV.
MECH.
SELF-
CLOSING
DOOR
TENANT FINISH
TENANT FINISH
CEILING TO BE 1-HOUR
FIRE RATED (TYP)
EXIT
COMMON
ELECT.
PNL.
COMMERCIAL
STORAGE 2
SCALE: 1/4" = 1'-0"
LOWER LEVEL PLAN NORTH
DHW DHW
BOILER #1
BOILER #2
BOILER #3 BOILERS WALL MOUNTED
SEWER EXITS
APPROX. 42" ABOVE
FLOOR
DOOR EAST SIDE
OF ROOM
EXISTING FLOOR
DRAIN DOESN'T
WORK
RADIANT VALVES
AND PUMPS ON
THIS WALL
SNOWMELT
VALVES
AND PUMPS ON
THIS WALL
NEW FLOOR SINK
TO
BE INSTALLED
NEW EJECTION
BASIN TO PUMP
BACK INTO
SEWER LINE
ELECTRIC PANEL
CANNOT BE
HERE
NEW DENTIST OFFICE
EQUIPMENT CLOSET
FRAMED NICHE
FOR ALARM
PANEL
ERV AT CEILING
CORE DRILL SLAB AT
CEILING. RUN DUCT TO
CEILING AND OUT
THROUGH NORTH BRICK
WALL
TELEPHONE, TV,
INTERNET
SERVICE ON
WALL
ELEVATOR
EQUIPMENT
NEW WATER
SERVICE
ENTERS
BASEMENT HERE
DOMESTIC
WATER
PRESSURE
RELIEF VALVE
ON WALL
FIRE SPRINKLER
PRV AND
BACKFLOW
PREVENTER ON
WALL
DOMESTIC BACKFLOW
PREVENTOR AND WATER
METER ON WALL
THERE IS NO
FLOOR DRAIN
FOR WATER
SERVICE ENTRY
Received
2/22/2016 11:43:25 AM
A 2.4
ROOF PLANASPEN CLINIC BUILDING REMODEL100 EAST MAIN STREETASPEN, COPERMIT SET 7/22/14
5/31/16PRINTED ON
ALL DESIGNS, IDEAS ARRANGEMENTS
AND PLANS INDICAT ED BY THESE
DRAWINGS AND SPECIFICATIONS ARE
THE PROPERTY AND COPYRIGHT OF KIM
RAYMOND ARCHITECTS, INC. AND SHALL
NEITHER BE USED ON ANY OTHER
WORK NOR BE USED BY ANY OTHER
PERSON FOR ANY USE WHATSOEVER
WIT H OUT W RI TT E N PERM I S SIO N .
WRITTEN DIMENSIONS SHALL TAKE
P R E C E D E N C E O V E R S C A L E D
DIMENSIONS AND SHALL BE VERIFIED AT
T H E S I T E . A N Y D I M E N S I O N A L
DISCREPANCY SHALL BE BROUGHT TO
THE ATTENTION OF THE ARCHITECT
PRIOR TO COMMENCEMENT OF WORK.
IF THE ABOVE DIMENSION
DOES NOT MEASURE ONE
I N C H (1 ") E X A C TLY, THI S
DRAWING WILL HAVE BEEN
EN LA RGE D OR RED UCE D,
AFF E C T I NG A LL LABEL E D
SCALES.
1" ACTUAL www.KimRaymondArchitects.comtel 970-925-2252 email kim@krai.usPERMIT CLARIF. 7/20/15
CONST. CLARIF. 9/30/15
CHANGE ORDER 1 10/26/15
CONST. CLARIF. 1/7/16
C.O.# 1 CLARIF 3/25/16
CONST. CLARIF. 5/31/16
CUT SHEET
Overview
Developed by architectural sheet metal professionals,
the Original Polycarbonate™ offers 25 square inches of
bonding surface - the larger the base, the greater the
holding power. The Original Polycarbonate™ has the
largest base available in the industry! Manufactured from
clear UV-stabilized polycarbonate material, or in a color
that is injected throughout the product and matched to
any standard roof panel. Inset base for metal roof panels
with stiffening ribs. Apply using tube adhesive or a
mechanical fastening application.
Innovation
Manufactured from UV-stabilized polycarbonate, the
unique design of these crystal-like guards suspends the
field of snow until the snow and ice gradually melt under
the sun’s rays.
CUT: Sno Gem® snow guard’s prismatic design was
developed by architectural sheet metal professionals
with over 100 combined years of on-the-roof experience.
CLARITY: Sno Gem® offers a clear prismatic snow guard
which retains its crisp, clean and architectural appeal.
There’s no metal to rust or stain. Sno Gem® snow guards
are unaffected by climate extremes.
COLOR: Sno Gem® snow guards can be matched to all
industry standard metal roof colors. Sno Gem® also offers
an unlimited amount of custom colors to closely match
the metal roof panel. The color is injected throughout the
product.
CARAT: The true measure of a gem’s worth. At the heart of
each Sno Gem® is an engineered, multi-directional, multi-
purpose drain opening for melting snow and ice to flow
freely, plus heat cables can be easily routed through the
opening.
Dimensions
Height: 3.25” - Width: 5” - Length: 5”
Applications
For Ribbed Panel Metal Roof Systems.
Colors
Available in Clear or Color to Match
Virtually Any Standard Metal Roof
Panel Manufacturers.
Recommended Accessories
Depending on the application, the following accessories are
available to ensure proper installation.
Original Polycarbonate™ Snow Guard with Inset Base
For Metal Roof Systems
3M VHB Tape Application Shown
Isopropyl Alcohol
Panel Cleaner
Surebond
SB-190 Adhesive
*Seller assumes no responsibility for the warranty. Check your roof manufacturer’s warranty information before installation.
A
A
E
E
F
F
B
B
1 1
4 4
6 6
2 2
3 3
5 5
C
C
D
D
J
18'-5 3/4"43'-2 1/4"18'-5 1/2"18'-5"20'-5"13'-2"2'-6"2'-3/4"13'-4"2'-3/4"17'-3 1/4"19'-3 3/4"4'-7 3/4"25'-2 1/2"
33'-6 1/4"20'-4"3 1/2"8 3/4"3'-9 1/2"3 1/2"3'-4"3'-2 3/4"1 3/4"1'-8""FLAT" ROOF AT NEW ELEVATOR
SEE STRUCTURAL DRAWINGS
FOR STEEL FRAME AT NEW
ROOF AND DOOR
SNO-GEM SNOW RETENTION (TYP.)
SNO-GEM SNOW RETENTION (TYP.)SNO-GEM SNOW RETENTION (TYP.)
REBUILD EXISTING TOP OF
CHIMNEY AND INSTALL NEW
FLUE-LINER
TERMINATE DRYER VENT AT
ROOF. PROVIDE RAIN CAP
CRICKET AT NEW ROOF
VENT TERMINATION FOR
LIVING ROOM FIREPLACE
SCUPPER PENETRATION AT
LOW POINT OR ROOF
RECESS
SCUPPER DISCHARGES
ONTO ROOF AND RUNS INTO
WEST GUTTER, DOWNSPOUT
NEW METAL FASCIA, TYP.
"FLAT" ROOF
AT NEW
PATIO DOOR
NEW UPPER ROOF:
MATCH EXISTING
ROOF PITCH
1.5:12 V.I.F.
EXISTING
LOW ROOF
PITCH
V.I.F.
EXISTING
ROOF PITCH
1.5:12 V.I.F
NEW DECK
BELOW
REFRAME
FLAT ROOF
TO SET
BELOW
EXISTING TO
SHIELD MECH.
NOTE: REPLACE / REWORK ALL
EXTERIOR GUTTERS AND DOWNSPOUTS
PER DRAINAGE PLAN V.I.F.V.I.F.V.I.F.RELOCATED
MECHANICAL
EQUIPMENT.
NO GUARDS
REQUIRED
ACCESS
ROOF
WINDOW
EXISTING
ROOF PITCH
1.5:12 V.I.F
EXISTING
ROOF PITCH
1.5:12 V.I.F
EXISTING
ROOF PITCH
1.5:12 V.I.F
ACCESS
ROOF
WINDOW
TAR AND GRAVEL TAR AND GRAVEL
TAR AND GRAVEL
TAR AND GRAVEL
V
NORTH

A/C
CONDENSING
UNIT FOR FC 1 IN
PENTHOUSE
A/C
CONDENSING
UNIT FOR FC 2 IN
PENTHOUSE
A/C CONDENSING UNIT
FOR FUTURE OFFICE 4
A/C
CONDENSING
UNIT FOR
FUTURE OFFICE
3
A/C
CONDENSING
UNIT FOR
FUTURE OFFICE
2
FUTURE DENTIST
OFFICE #1
EQUIPMENT
Received
2/22/2016 11:43:25 AM
ri
EXIT TO
EXTERIOR
CODE PLAN
5CALE:
u
L
u
E
LH
DD o0
Ll
TRA
----------------------- ---VEL STANCE: 81'-6"
v -----m-- ----------------- -----------------------
r-------------------------------------------------------------------------
1 TRAVEL pISTANCE: 107-I0"
1 0 _ 0 0
1 / 21
-gIvATE OFFICE
ILIZATI IL
STAFF IIS 'moi �I�LI���
114 G ; l IIT / IIS 119 122
� 1 c]p \
l
6 43
/
1
1 TENANT SPACE
1
n e
zzzzzzzzzz
NOTE:
ALL DRAWINGS CONTAINED IN THIS PACKAGE ARE BASED ON
THE EQUIPMENT AND EQUIPMENT DETAILS CONTAINED ON THE
CENTER POINT DESIGN / BENCO DENTAL DRAWINGS INCLUDED
AT THE END OF THIS PACKAGE. IF EQUIPMENT OTHER THAN
WHAT IS SPECIFIED ON THESE DRAWINGS IS PURCHASED, THE
INSTALLATION, UTILITY CONNECTIONS AND SPACE
REQUIREMENTS MAY BE DIFFERENT AND IT SHALL BE THE
RESPONSIBILITY OF THE OWNER AND HIS/HER CONTRACTORS
TO MAKE THE NECESSARY MODIFICATIONS IN THE FIELD TO
ACCOMMODATE THIS EQUIPMENT.
DESCRIPTION OF W01WQ
WORK ASSOCIATED WITH THIS PROJECT INVOLVES AN INTERIOR
FIT -OUT OF AN EXISTING TENANT SPACE. THE EXISTING BUILDING HAS
A FOOTPRINT APPROXIMATELY 3,520 SQUARE FEET AND CONSISTS OF
TWO LEVELS AND PARTIAL BASEMENT. THIS PROJECT INVOLVES THE
TENANT FIT -OUT OF APPROXIMATELY 2,137 SQUARE FEET.
THE EXISTING WATER SERVICE TO THE BUILDING SHALL REMAIN.
MECHANICAL WORK WILL INCLUDE THE ADDITION OF NEW SPLIT
SYSTEM UNITS.
THE EXISTING ELECTRICAL SERVICE TO THE BUILDING SHALL REMAIN.
A NEW PANEL WILL BE ADDED TO THE SPACE AND DISTRIBUTION
FROM WITHIN SHALL BE NEW.
CODE REVIEW BASED ON 2015 EDITION OF THE INTERNATIONAL
BUILDING CODE, 2015 IFC, 2015 IMC, 2015 IPC, 2015 NEC AND ICC/ANSI
A117.1- 2015,
THE EXISTING BUILDING SHELL AND SECOND FLOOR ARE CURRENTLY
UNDER CONSTRUCTION UNDER A SHELL PERMIT FOR MIXED USE
OCCUPANCY. THIS TENANT SPACE WILL BE SEEKING A 'B' BUSINESS
OCCUPANCY.
IJSE � OfLJJpANCY.
THIS TENANT FIT -OUT WILL BE A 'B' OCCUPANCY- PROFESSIONAL
SERVICES (DENTIST)
Q4CM7NLr_TM TYPE (TAMILE &01
TYPE VB COMBUSTIBLE. PROPOSED RENOVATION/ADDITION DOES
NOT CHANGE THIS CLASSIFICATION AND WILL COMPLY WITH TYPE VB
REQUIREMENTS.
e111LDM6 NEIBL/r dND AREA CTABLE 503),
BUILDING AREA:
TENANT SPACE = 2,131
TOTAL FIRST FLOOR AREA= 2,131 sf (COMPLIES w/ MAXIMUM
BUILDING AREA IN TABLE
503 9,000sf)
BUILDING HEIGHT: BUILDING HEIGHT 15 EXISTING AND SHALL NOT BE
ALTERED BY THIS PROEJCT. BUILDING MEET5 REQUIREMENTS OF
TABLE 503.
NOTE:
ALL ARCHITECTURAL DRAWINGS SHALL BE
CONSIDERED AN EXTENSION OF, AND USED
IN COORDINATION AND CONJUNCTION WITH,
ALL BENCO / CENTER POINT DESIGN
DRAWINGS CONTAINED IN THIS DRAWING
PACKAGE (Q -SERIES DRAWINGS)
INTERIOR FINISHES:
EXIT ENCLOSURES a PASSAGEWAYS- N/A
CORRIDORS- N/A
ROOMS a ENCLOSED SPACES- CLASS C
AUTOMATIC SPRINKLERS ARE PROVIDED AND SHALL BE ALTERED
PER THIS TENANT FIT -OUT TO COMPLY WITH LIFE SAFETY CODES
WILE FIRE E)CrtrA99I4ER&
ONE EXTINGUISHER PROVIDED FOR STAFF AND PUBLIC USE. TWO
ADDITIONAL PROVIDED FOR STAFF USE BELOW CABINETS. TRAVEL
DISTANCE TO EXTINGUISHER NOT GREATER THAN 75'
FIREALARM AND DETEOTION SYSTEM.
PRE ALARP' S"BTPM SHALL BE BE FURNISHED WITH THIS TENANT FIT-OUT
-ROJECT.
EXITM6 FROM TENANT SPACE.
2,131 sr, NO DEDUCTIONS
100 sf / OCCUPANT (TABLE 1004.1.1)
2,131 sf / 100 (occ/sr) = 22 OCCUPANTS
DOORS/AISLES- 22 OCC. x 0.2" = 4.4" OF EXIT REQUIRED. 12" OF
DOOR WIDTH PROVIDED AND MINIMUM AISLE WIDTH OF 40"
PROVIDED (1017.3- NOT LESS THAN 36")
ACCESSIBLE EGRESS- BOTH EXITS ARE ACCESSIBLE.
COMMON PATH OF EGRESS TRAVEL (1014.3)- T5'. SPACE COMPLIES.
EXIT ACCESS TRAVEL DISTANCE- 200' PERMITTED. FURTHEST
PROPOSED TRAVEL DISTANCE 107'-10".
PI IMBW.
22 OCCUPANTS DIVIDED BY 2 = II MEN AND II WOMEN OCCUPANTS.
FIXTURES REQUIRED (TABLE 2SO2.1):
ONE WATER CLOSET EACH FOR MEN AND WOMEN- TWO TOTAL PROVIDED
(LOCATED IN EXISTING LOBBY FOR PUBLIC USE. ONE NEW TOILET ROOM
PROVIDED WITHIN TENANT SPACE.
ONE LAVATORY FOR EACH MEN AND WOMEN- THREE TOTAL PROVIDED
ONE SERVICE SINK REQUIRED- PROVIDED FOR TENANT USE.
PUBLIC DRINKING FOUNTAINS PROVIDED FOR USE IN EXISTING LOBBY.
1
EXISTING
LeeY
1
1
1
1
1
L
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
EXIT TO
EXTERIOR
EXISTING
TOILET RM.
F
OF
Brian A. Clark
404258
U
cp
LLI
00
�
O
N
t7
nO
w
V
Z
O
X
t1)
(L
�
— w
I-
W
ZI
Z
p
O
�c
�4
4n/
o
.nQ
:3
,dn
z
F -
Q
5�
Z
�
o
Z
Q
O
UN1
Q
U
cp
LLI
Ii 1�
�
w
j)
N
t7
nO
w
V
Z
O
X
t1)
(L
�
— w
I-
W
ZI
Z
LLI
>
w
�4
4n/
.nQ
:3
,dn
z
F -
Q
W
Z
�
o
Z
Q
SHEET NO.
ri
u
6'-3"t
4
e TYP.
DEMOLITION FLOOR PLAN C
SCALE: 114"=I' -O"
IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN
THE WORK. IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS
ARE ENCOUNTERED, DO NOT DISTURB: IMMEDIATELY NOTIFY ARCHITECT AND
OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER A
SEPARATE CONTRACT.
rep,
II'-O}"s I 3� 'i
O
OY
4
e TYP.
u
O�-
ALL WALLS AS SHOWN ON THIS DRAWING TO BE REMOVED MAY NOT BE
CONSTRUCTED IN PLACE AT THE TIME OF THIS PROJECT. GENERAL
CONTRACTOR IS TO VISIT THE SITE PRIOR TO AN DEMOLITION AND FAMILIARIZE
THEMSELVES WITH EXISTING CONDITIONS. NOTIFY THE ARCHITECT OF ANY
CONFLICTS,
E
EXISTING COLUMNS
EX REMAIN 5
a
m TYP. G
DEMOLITION LEGEND: DEMOLITION KEY NOTES:
SOLID LINES INDICATE WALL5 TO REMAIN I. THE INTENT OF DEMOLITION PORTION OF THIS PROJECT 15 TO REMOVE
ALL INTERIOR (NON-STRUCTURAL) FINISH ITEMS AS DEPICTED THIS
DRAWING. THIS INCLUDES, BUT IS NOT LIMITED TO: ALL FLOORING
MATERIAL, BATHROOM TILE, INTERIOR DOORS, LIGHT FIXTURES AND
ELECTRICAL DEVICES (WIRING TO REMAIN), PLUMBING FIXTURES, ETC.
=e111% SOLID LINES INDICATE DOORS TO REMAIN THERE IS SELECTIVE DEMOLITION ALONG THE EXTERIOR WALL5 FOR NEW
BUILDING ADDITION AND DOOR INFILL. COORDINATE DEMOLITION WITH
ALL NOTES AND TAGS THIS DRAWING.
_-------_ DASHED LINES INDICATE WALLS TO BE REMOVED 2. COORDINATE WITH PLUMBING, ELECTRICAL 4 MECHANICAL DRAWINGS
FOR ANY SELECTIVE DEMOLITION TO INSTALL NEW SYSTEMS. O REMOVE EXISTING WALL FINISH AS REQUIRED TO INSTALL WOOD
3.COORDINATE WITH ELECTRICAL LIGHTING PLAN FOR NEW LIGHT FIXTURE BLOCKING FOR TOILET ROOM ACCESSORIES. COORDINATE WITH
LAYOUT. GENERAL CONTRACTOR TO COORDINATE WITH ELECTRICIAN CONSTRUCTION NOTE 13414 ON DRAWING A-1.
DASHED LINES INDICATE DOORS TO BE REMOVED FOR ALL CEILING DEMOLITION REQUIRED TO INSTALL NEW LIGHT REMOVE EXISTING WALL FINISH AS
FIXTURES. O BLOCKING FOR MILLWORK INSTALLATION( COORDINATE WITH RED TO INSTALL OOD
REMOVE EXISTING DOOR AND FRAME IN ITS ENTIRETY. DEMOLITION TO CONSTRUCTION NOTE I ON DRAWING A-1 AND MILLWORK ELEVATIONS -
DEMOLITION GENERAL NOTES:
I. GENERAL CONTRACTOR RESPONSIBLE FOR COORDINATION WITH EXISTING INCLUDE, BUT NOT BE LIMITED, TO DOOR, FRAME, ASSOCIATED TYPICAL ENTIRE LENGTH OF MILLWORK
CONDITIONS FOR ALL WORK COMPLETED UNDER SEPARATE BUILDING SHELL HARDWARE, THRESHOLDS AND ANCHORS. DOOR HEADER REMAIN. O REMOVE EXISTING WALL FINISH REQUIRED INSTALL WOOD
PERPERMIT.O REMOVE EXISTING WINDOW IN ITS ENTIRETY. DEMOLITION TO INCLUDE, BUT BLOCKING FOR Tv/MONITOR INSTALLATION.
LLATION. COOO RDINATE WITH
NOT BE LIMITED TO GLAZING, FRAMES 4 HARDWARE, ETC. CONSTRUCTION NOTE 446 ON DRAWING A -I. COORDINATE FINAL
2. THIS DEMOLITION DRAWING IS PROVIDED AS A GENERAL GUIDE TO THE LOCATION WITH OWNER IN FIELD.
REMOVAL OF MATERIALS NEEDED TO FULLY COMPLETE THIS PROJECT AND O REMOVE PORTION OF EXISTING BEARING WALL FOR NEW OPENING IN
MUST BE USED IN CONJUNCTION AND COORDINATION WITH ALL OTHER WALL. DEMOLITION TO INCLUDE, BUT NOT BE LIMITED TO CMU WALL
DRAWINGS IN THIS PACKAGE AS NOT ALL WORK NEEDED TO COMPLETE THIS CONSTRUCTION, WOOD STUDS, WALL TILE, BRICK VENEER ETC. GENERAL
PROJECT'S SCOPE OF O.IORK CAN BE DEPICTED HERE. CONTRACTOR RESPONSIBLE FOR PROVIDING ANY TEMPORARY BRACING
3. ITEMS TO BE REMOVED ARE SHOWN DASHED. AS NEEDED FOR NEW STRUCTURAL HEADER INSTALLATION.
O REMOVE EXISTING FLOORING FINISH IN ITS ENTIRETY. DEMOLITION TO
4. GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL, PLUMBING, AND INCLUDE, BUT NOT BE LIMITED TO, VCT, CERAMIC TILE, CARPET, WALL
ELECTRICAL CONTRACTORS FOR PENETRATIONS THRU WALLS, CEILING AND BASE, ADHESIVE, ETC. GENERAL CONTRACTOR TO EVALUATE EXISTING
ROOF TO RUN UTILITIES. GENERAL CONTRACTOR SHALL BE RESPONSIBLE SUB FLOOR AND REPLACE/REPAIR AS NECESSARY TO PROVIDE LEVEL
FOR CUTTING HIS OWN PENETRATIONS AND ALL PATCHING. PATCHING SURFACE FOR NEW FLOORING- TYPICAL THROUGHOUT ENTIRE BUILDING.
THROUGH EXTERIOR WALLS AND CEILINGS SHALL BE WATER/WEATHER
PROOF. O REMOVE EXISTING WALL IN ITS ENTIRETY. DEMOLITION TO INCLUDE, BUT
5. GENERAL CONTRACTOR TO REMOVE ALL EXISTING FINISHES ON EXTERIOR NOT BE LIMITED TO GYPSUM BOARD/PLA5TER, BRICK VENEER, WALL
WALLS DOWN TO MASONRY OR STUDS FOR NEW UTILITY WORK. AT MASONRY TILE, WOOD STUDS, WOOD BASE, UTILITIES, ETC.
WALLS, GENERAL CONTRACTOR TO PROVIDE AND INSTALL FURRING STRIPS O REMOVE EXISTING WALL FINISH IN ITS ENTIRETY. DEMOLITION TO INCLUDE,
AND 5%" GYPSUM BOARD. 6 BUT NOT BE LIMITED TO, WOOD VENEER, WALL TILE, BRICK VENEER, CMU,
WOOD STUD FURRING, GYPSUM BOARD, WOOD/VINYL BASE, ETC. -
TYPICAL ALL INTERIOR PARTITIONS TO REMAIN
F
OF
* Brian A. Cl
404258
Cl
Ucp
LLI
00
lL
01
�Cwtt%
O
N
N
1nOv,
yV
L
�
✓1-F
1' t
w
iu
tl
Z
11—
X
OL
IL
I�
— w
I
ZI
�
O
`O
�nI
4n/
4
C�
,d
l7
Q
W
O
W
Z
Q
O
UN1
Q
Q
Ucp
LLI
Ii 1�
lL
01
�Cwtt%
N
N
1nOv,
yV
L
�
✓1-F
1' t
w
iu
tl
Z
O
X
OL
IL
— w
I
ZI
Z
LLI
4n/
4
:3V/
,d
l7
Q
W
O
Z
Q
SHEET NO,
D
ri
COORDINATE FINAL FLOOR CUTTING
DIMENSIONS IN FIELD IN CONJUNCTION WITH
PLUMBING 6 ELECTRICAL DRAWINGS
FLOOR CUTTING PLAN
SCALE: 114"=I' -O"
IT IS NOT EXPECTED THAT HAZARDOUS MATERIALS WILL BE ENCOUNTERED IN
THE WORK IF MATERIALS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS
ARE ENCOUNTERED, DO NOT DISTURB: IMMEDIATELY NOTIFY ARCHITECT AND
OWNER. HAZARDOUS MATERIALS WILL BE REMOVED BY OWNER UNDER A
SEPARATE CONTRACT.
DEMOLITION GENERAL NOTES:
I. GENERAL CONTRACTOR RESPONSIBLE FOR COORDINATION WITH EXISTING
CONDITIONS FOR ALL WORK COMPLETED UNDER SEPARATE BUILDING SHELL
PERMIT.
2. THIS DEMOLITION DRAWING 15 PROVIDED AS A GENERAL GUIDE TO THE
REMOVAL OF MATERIALS NEEDED TO FULLY COMPLETE THI5 PROJECT AND
MUST BE USED IN CONJUNCTION AND COORDINATION WITH ALL OTHER
DRAWINGS IN TH15 PACKAGE AS NOT ALL WORK NEEDED TO COMPLETE THIS
PROJECT'S SCOPE OF WORK CAN BE DEPICTED HERE.
3, ITEMS TO BE REMOVED ARE SHOWN DASHED.
4. GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL, PLUMBING, AND
ELECTRICAL CONTRACTORS FOR PENETRATIONS THRU WALLS, CEILING AND
ROOF TO RUN UTILITIES. GENERAL CONTRACTOR SHALL BE RESPONSIBLE
FOR CUTTING HIS OWN PENETRATIONS AND ALL PATCHING. PATCHING
THROUGH EXTERIOR WALLS AND CEILINGS SHALL BE WATER/WEATHER
PROOF.
5, GENERAL CONTRACTOR TO REMOVE ALL EXISTING FINISHES ON EXTERIOR
WALLS DOWN TO MASONRY OR STUDS FOR NEW UTILITY WORK. AT MASONRY
WALLS, GENERAL CONTRACTOR TO PROVIDE AND INSTALL FURRING STRIPS
AND s/e" GYPSUM BOARD.
u
L
12" l'l_ 2'-I" 6'-5a" , 2'-1"
u
4'-S"
E
F
OF
Brian A. Clark
404258
II
0)
II I I I I ti
II II I I I I �� �
II II III w o
II II � I� I'n
N
r \
ti
- O O
00 z
ll -
0¢ Z
L
�+
O �c
� 0
W
0 - : T
Q
FLOOR DEMOLITION AND REPAIR NOTES:
THE EXISTING (ASSUMED) 4" THICK CONCRETE FLOOR SLAB WILL NEED TO
BE SAW CUT AND REMOVED (ALONG WITH ANY STONE FILL AND EARTH) TO
ACCOMMODATE NEW PLUMBING SANITARY AND WATER LINES, AIR
COMPRESSOR AND VACUUM LINES, COMMUNICATION WIRING, CONTROL WIRING,
POWER WIRING AND BOXES.
CONTRACTOR SHALL WORK WITH BENCO REPRESENTATIVE AND BENCO
DENTAL DRAWINGS TO LOCATE EQUIPMENT IN THE SPACE PRIOR TO
CUTTING. ALSO CONFIRM NEW LOCATIONS OF SINKS IN THE BREAK ROOM,
LAB, TOILET ROOMS AND STERIL, ALONG WITH THE FINAL LOCATIONS OF THE
AIR COMPRESSOR AND VACUUM UNIT PRIOR TO FLOOR CUTTING. THIS
DRAWING 15 PROVIDED AS A GUIDE, MODIFICATIONS IN FIELD TO
ACCOMMODATE EQUIPMENT OR BEST CONSTRUCTION PRACTICES ALLOWED.
IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO LAYOUT THE
NECESSARY UNDERGROUND UTILITIES WITH HIS SUB -CONTRACTORS TO
DETERMINE THE EXTENT AND PATH OF CONCRETE, ETC. TO BE REMOVED.
DEPTH OF EXCAVATION SHALL DEPEND ON ROUTE OF PLUMBING PLAN AND
DEPTH OF TIE IN POINT TO EXISTING SANITARY LINE.
WHEN ALL NEW ELECTRICAL, PLUMBING, AIR COMPRESSOR AND VACUUM LINE
WORK IS INSTALLED, GENERAL CONTRACTOR SHALL INSTALL COMPACTED
SUB -GRADE TO MATCH EXISTING ELEVATIONS (PACKING PIPES ON AND
AROUND SAND BASE), PLASTIC VAPOR BARRIER, AND MINIMUM 4" STONE
FILL BELOW NEW MINIMUM 4" CONCRETE (WITH FIBER MESH) SLAB ON GRADE.
TIE NEW CONCRETE SLAB TO EXISTING WITH •4 DOWELS AT 32" O.C. (DOWELS
EXTENDING MINIMUM 6" INTO NEW AND EXISTING).
DEMOLITION KEY NOTES: I
HATCHED AREA INDICATES APPROXIMATE AREA TO HAVE CONCRETE
FLOOR SAW CUT AND REMOVED, ALONG WITH APPROXIMATELY 2'-0" OF
DIRT FOR UTILITIES TO BE RUN BELOW FLOOR.
THE AREA SHOWN ON THIS DRAWING IS APPROXIMATE FOR GRAPHIC
PURPOSES ONLY. THE ACTUAL AREA SHOULD BE LAID OUT IN THE FIELD
WITH ACTUAL DIMENSIONS TO THE EQUIPMENT OR FIXTURE LOCATIONS.
VERIFY DEPTH OF DIRT EXCAVATION WITH EXISTING INVERT ELEVATIONS
IN FIELD AND LENGTH OF RUNS.
Ucp
LLI
Ii l�
lL
r�
01
,
O
r
N
WZ
V
Z
O
X
OL
ILw
—
I
W
ZI
Z
LLI
�
w
✓H-4
�
4n/
.nQ
:3
,dn
Z
F -
Q
W
O
Z
Q
SHEET NO.
2
Received
2/22/2016 11:43:25 AM
ri
GYPSUM BOARD
CEILING ® 8'-6" AFF.
GYPSUM BOARD —
BULKHEAD/SOFFIT 9
1'-0" A.FF.
GYPSUM BOARD
CEILING 6 8'-6" APF.
A.C.T 0 8'-011t A.FF.
A.C.T a 8'-O'4 AFF.
REFLECTED CEILING PLAN
NOTE:
ALL DRAWINGS CONTAINED IN THIS PACKAGE ARE BASED ON
THE EQUIPMENT AND EQUIPMENT DETAILS CONTAINED ON THE
CENTER POINT DESIGN / BENCO DENTAL DRAWINGS INCLUDED
AT THE END OF THIS PACKAGE. IF EQUIPMENT OTHER THAN
WHAT IS SPECIFIED ON THESE DRAWINGS IS PURCHASED, THE
INSTALLATION, UTILITY CONNECTIONS AND SPACE
REQUIREMENTS MAY BE DIFFERENT AND IT SHALL BE THE
RESPONSIBILITY OF THE OWNER AND HIS/HER CONTRACTORS
TO MAKE THE NECESSARY MODIFICATIONS IN THE FIELD TO
ACCOMMODATE THIS EQUIPMENT.
u
.YPSUM BOARD A.C.T ® S' -0"t AFF
BULKHEAD/SOFFIT g I\
'-O" AFF. I\
A.C.T m 8'-O"!
NOTE:
ALL ARCHITECTURAL DRAWINGS SHALL BE
CONSIDERED AN EXTENSION OF, AND USED
IN COORDINATION AND CONJUNCTION WITH,
ALL BENCO / CENTER POINT DESIGN
DRAWINGS CONTAINED IN THIS DRAWING
PACKAGE (0 -SERIES DRAWINGS)
GYPSUM BOARD SOFFIT/BULKHEAD NOTES:
I. GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL AND
ELECTRICAL DRAWINGS TO ACHIEVE DESIRED CLEAR DIMENSIONS
TO CONCEAL UTILITY RUNS.
2. GENERAL CONTRACTOR TO FRAME SOFFITS WITH 2X4s ® 16" O.C. ON
THE FLAT AS TO MAXIMIZE CLEAR DIMENSION WITHIN SOFFIT.
3. PROVIDE 11/¢" GYPSUM BOARD ON SOFFITS.
L
GYPSUM BOARD
BULKHEAD/SOFFIT
T -O" AFF.
A.C.T 0 8'-011=
u
T o 6'-0"1 AFF.
A.C.T e 8'-O" x AFF.
NOTE:
ALL CEILINGS IN TH15 TENANT SPACE, (EITHER FINAL FINISHED
CEILING OR ABOVE A.C.T. CEILING SHALL HAVE A ONE HOUR
FIRE RATING AND COMPLY WITH U x'263. GYPSUM BOARD TO BE
PROVIDED AND INSTALLED UNDER SEPARATE CONTRACT WITH
DEVELOPER.
CEILING CONSTRUCTION NOTES:
I. GENERAL CONTRACTOR TO PROVIDE ALL FRAMING REQUIRED
BETWEEN PARTITION WALLS FOR GYPSUM BOARD CEILING
INSTALLATION. COORDINATE EXACT HEIGHTS WITH HEIGHTS LISTED
ON THIS DRAWING.
2. VERIFY ALL SOFFIT DIMENSIONS WITH CABINET SUPPLIER AND
SHOP DRAWINGS PRIOR TO FRAMING.
CEILING LEGEND
INDICATES 2x2 SUSPENDED ACOUSTICAL
TILE CEILING SYSTEM. ACTUAL SYSTEM
DESIGN TO BE DETERMINED BY OWNER
AND CONTRACTOR.
INDICATES GYPSUM BOARD BULKHEAD
a 1'-0" AFP. TO MATCH WALL THICKNESS
UNLESS OTHERWISE NOTED.
E
F
GYPSUM BOARD
CEILING 0 8'-6" AFF.
OF
Brian A. Clark
404258
� 41
zt 6 0 1w r --A Z 0
N
GYPSUM BOARD
SOFFIT ® 8'-O" AFF.
CENTERPOINT GYPSUM BOARD h'-1
OF RADIUS CEILING a 8'-6" AFF.
O
0-0 Z
O �¢
--4"
w y U
Cc
ti
- Qw w
O
W
LLI
0
U
} 0)
(LOL
% N N
Z O X
W 0 Z
Q }
4 d 4
���
Lu
p LU
z
SHEET NO,
4=_2
Received
2/22/2016 11:43:25 AM
Received
2/22/2016 11:43:25 AM
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5
3
2
6
4
1
CB
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
EXITMECHANICAL - UPPER LEVEL FLOOR PLANM1-1DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:24 AM
M1-2MECHANICAL - MAIN LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:24 AM
EXITM1-3MECHANICAL - LOWER LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:24 AM
M1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEW1. SCOPE OF WORKA. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED.B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE ADOPTED INTERNATIONAL MECHANICAL CODE, ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK OF THIS NATURE.C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS.D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT.2. PERMITSA. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES.3. SHOP DRAWINGSA. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ACHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED.4. FLEXIBLE DUCT WORKA. FLEXIBLE TYPE DUCT SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION COMPOSED OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND COATED FABRIC WITH A MINERIAL BASE. FLEXIBLE DUCT CONNECTORS SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50.B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE THAN 8 LINEAR FEET PER RUN.C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR COLLAPSE FLEXIBLE DUCT.5. REFRIGERENTA. PIPING CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH THE MANUFACTURER'S REC0MMENDATIONS AND IN SUCH A WAY AS TO BE INCONSPICIOUS AND FREE FROM ANY POSSIBLE CONDENSATION.B. INSULATE REFRIGERANT LINES WITH ARMOUR-FLEX TYPE INSULATION, SHALL BE TYPE "K" COPPER TUBING, WITH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER.6. DUCTWORKA. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS.B. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED OTHERWISE.C. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK WHICH PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS OTHERWISE SHOWN ON DRAWINGS.D. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS, SMOOTH TURN RADIUS DUCTWORK OR TURNING VANES SHALL BE USED THROUGHOUT WHERE FLOW EXCEEDS 150 CFM.E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH "SMACNA" STANDARDS AND ACCEPTED GOOD PRACTICE.F. ALL DUCT DIMENSIONS SHOWN ARE NET INSIDE VALUES.DIMENSIONS MAY BE CHANGED SO LONG AS THE NET FREE FACE AREA IS MAINTAINED.G. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1-1/2" FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING.H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM OF THE HVAC UNIT SHALL BE INTERNALLY LINED WITH A 1/2" ACOUSTICAL DUCT LINER.7. DRAINAGE PIPINGA. (CONDENSATE) SHALL BE SCHEDULE 40 PVC PIPE WITH SOLVENT JOINTS. PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS SHALL BE ROUTED TO FLOOR DRAIN OR INDIRECT WASTE DRAIN.8. HYDRONIC PIPING - CHILLED & HEATINGA.TYPE "L" COPPER OR SCHEDULE 40 STEEL.B.PIPE INSULATION AS FOLLOWS: HOT WATER PIPE <1.5" 1-1/2" INSULATION>1.5" 2"INSULATIONCHILLED WATER PIPE ALL 1-1/2" INSULATION9. HVAC CONTROLSA. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING AND THERMOSTATS AS REQUIRED.10. ELECTRICALA. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR A. FOR LOCATION OF WIRING FOR EACH HVAC UNIT.11. PIPE SUPPORTSA. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAP TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC PIPING TO BE SUPPORTED EVERY 4 FEET.12. GAS PIPINGA. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS.13. MISCELLANEOUSA. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND SEALED WITH A SEALANT OF HIGH QUALITY AND LONG LIFE, TO PREVENT INFILTRATION OF OUTSIDE AIR INTO CONDITIONED SPACE. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION.B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS.C. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE.D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT.E. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE SPACE.14. TESTING AND BALANCINGA. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED BY AN INDEPENDENT AGENCY, UNDER THE SUPER- VISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. THIS SHALL OCCUR PRIOR TOFINAL INSPECTION AND SHALL INCLUDE HYDRONICS FOR BOILER SYSTEM.15. GUARANTEEA. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE.B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM.16.BOILERA. STATE OF COLORADO BOILER INSPECTION REQUIRED FOR NEW BOILERS, PROVIDE DOCUMENTATION AT FINAL INSPECTION.FAN COIL SCHEDULEEQUIPMENT NO.SERVICESUPPLYAIR(CFM)OUTSIDEAIR(CFM)SUPPLYAIRE.S.P.(IN. W.G.)COOLINGHOT WATER HEATING COILFILTERSSUPPLYFAN(HP)ELECTRICALUNITWEIGHT(LBS.)MANUFACTURER & MODELOPTIONS/ACCESSORIESNOM.(TONS)OUTPUT(MBH)FLOW(GPM)EWT(°F) (MBH)V./PH./HZ.MCAMOCPFC-1UPPER LEVEL BEDROOMS975-0.834931802" TA1/2115/1/601015175MAGIC AIRE HBB-12FC-2UPPER LEVEL KITCHEN/LIVING900-0.834931802" TA1/2115/1/601015175MAGIC AIRE HBB-12 NOTES: 1. PROVIDE WITH MIXING SECTION, FILTERS AND RACK, DX COOLING COIL, 2 ROW HOT WATER HEATING COIL, AND CONTROLLER.AIR COOLED CONDENSING UNIT SCHEDULEEQUIPMENTNO.SERVICENOMINAL COOLING CAPACITY (TON)REFRIG. PIPINGELECTRICMANUFACTURER & MODELOPTIONS/ACESSORIESLIQUIDVAPORV/PH/HZMOP (A)MCA (A)CU-1FC-123/8"3/4"230/1/602515.7LENNOX - #XC16-024SEE NOTES 1, 2, 3CU-2FC-223/8"3/4"230/1/602515.7LENNOX - #XC16-024SEE NOTES 1, 2, 3CU-3AC-1,223/8"5/8"230/1/603018MITSUBISHI - #PUY-A24NHA4SEE NOTES 1, 2, 3 NOTES:1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER.2. OUTDOOR CONDITIONS OF 85 F.3. INDOOR CONDTIONS OF 79 F DB/61 F WB. EXHAUST FAN SCHEDULEEQUIPMENT NO.SERVICELOCATIONCFMEXTERNAL STATIC PRESS (IN.W.G.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESWATTSHPRPMVOLT/PH/HZEF-1RESTROOMSCEILING750.541-1456120/1/60COOK - #GC-140SEE NOTE 1 NOTES:1. SOLID STATE SPEED CONTROL, BACKDRAFT DAMPER, AND VIBRATION ISOLATORS.MAKE UP AIR SYSTEM SCHEDULEEQUIPMENT NO.SERVICESUPPLYAIR (CFM)OUTSIDEAIR (CFM)SUPPLY AIRE.S.P. (IN.W.G.)ELECTRIC HEATERSUPPLY FANUNITSHIPPINGWEIGHT(LBS.)MANUFACTURER & MODELOPTIONS /ACCESSORIESMODELMAX OUTPUTV./PH./HZ.FLADUCTCONNECTIONV./PH./HZ.POWER(W)MCAMOCPMS-1KITCHEN MAKE UP AIR6006000.5MUAH 10/1010 Kw240/1/604210"Ø120/1/60146215151FANTECH #MUAS-650SEE NOTE 1 THRU 3NOTES:1. PROVIDE OPTIONAL ELECTRICAL HEATING ELEMENT AS SPECIFIED ABOVE. PROVIDE A DEDICATED ELECTRICAL CIRCUIT FOR THE ELECTRIC HEATER.2. PROVIDE WITH FMAC CONTROLLER.3. INSTALLER TO INSULATE ENTIRE LENGTH OF THE MAKEUP AIR SYSTEM AND ALL DUCTWORK CONNECTED TO THE SYSTEM.GRILLE-REGISTER-DIFFUSER SCHEDULEEQUIPMENT NO.CONNECTION SIZETYPEMANUFACTURERMODELFINISHOPTIONS/ACCESSORIESSR-13" x 1'-6"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1SR-23" x 2'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1SR-34" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1SR-44" x 3'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1RG-14" x 2'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-25" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-31'-0" x 3'-0"CEILING MTD.PRICELBPPER ARCH.SEE NOTE 1RG-44" x 2'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1TR-16" x 1'-0"WALL MTD.PRICELBPPER ARCH.SEE NOTE 1NOTES:1. COORDINATE ALL MOUNTING TYPES WITH CEILING, SOFFIT, WALL, OR FLOOR STRUCTURE.HEAT RECOVERY VENTILATOR (HRV) SCHEDULEEQUIPMENT NO.SERVICELOCATIONCFMEXTERNAL STATIC PRESS (IN.W.G.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESWATTSHPRPMVOLT/PH/HZHRV-1VENTILATIONHUNG FROM STRUCTURE5000.75660-VARIABLE120/1/60FANTECH #SHR-6904 NOTES:1.DUCTLESS SPLIT AIR CONDITIONING SYSTEM SCHEDULEEQUIPMENT NO.SERVICECOOLING CAPACITY (MBH)PEAKAIRFLOWCFMSEER (EFFICIENCY)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESMCA (A)MOCP (A)V./PH./HZ.AC-1OFFICE 412,00042515.2--208/1/60MITSUBISHI, #PKA-A12HA4SEE NOTE 1AC-2OFFICE 412,00042515.2--208/1/60MITSUBISHI, #PKA-A12HA4SEE NOTE 1 NOTES:1. THROUGH TWINNING, BOTH AC-1 AND AC-2 ARE CONNECTED TO ONE OUTDOOR UNIT (CU-3).2. PROVIDE ONE HARD WIRED, WALL MOUNTED PAR-31MAA REMOTE CONTROLLER. CONTROL TO SIMULTANEOUSLY CONTROL BOTH INDOOR UNITS.3. PROVIDE MSDD-50TR-E DISTRIBUTION PIPE KIT (REQUIRED FOR COMBING INDOOR UNITS).4. INDOOR UNITS AC-1 & AC-2 TO BE POWERED BY OUTDOOR UNIT (CU-3).Received 2/22/2016 11:43:24 AM
M1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWSPLIT SYSTEM DETAILHYDRONIC BASEBOARD SCHEDULEEQUIPMENT NO.LENGTHHEIGHTTHICKNESSNOMINAL HEATOUTPUT(BTU/HR)FLUID FLOWRATE GPMEWT (°F)LWT (°F)MANUFACTURER & MODELFINISHOPTIONS/ACCESSORIESBB-12'-0"10"3.5"1,6001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-24'-0"10"3.5"3,2001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-36'-0"10"3.5"4,8001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1BB-48'-0"10"3.5"6,4001180160SLANT FIN, 350-10 SERIESPER ARCHSEE NOTE 1NOTES:1. PROVIDE WITH H-3 ELEMENT TYPE.CABINET UNIT HEATER SCHEDULEEQUIPMENT NO.SERVICESUPPLY AIR (CFM)HOT WATER HEATING HEATINGELECTRICALMANUFACTURER & MODELOPTIONS/ ACCESSORIESOUTPUT(MBH)FLOW(GPM)EWT(°F)V./PH./HZ.MOTOR HPCH-1LOBBY23014.11.64180115/1/601/15BEACON MORRIS #RW-1120-02SEE NOTE 1NOTES:1. PROVIDE WITH HOT WATER COIL, PSC MOTOR, WALL SEAL, AND RETURN AIR TEMPERATURE CONTROL.ELECTRIC WATER HEATER SCHEDULEEQUIPMENT NO.CAPACITY(GAL)RECOVERY @ 90DEG. F. RISE (GPH)WATER CONN.HEATINGELEMENTPOWER (KW)V/PH/HZMANUFACTURER & MODELOPTIONS/ACCESSORIESWH-150213/4"9 (TWO 4.5COILS)240/1/60RHEEM, PRO. CLASSIC #PROE50-T2-RH95SEE NOTE 1NOTES:1. PROVIDE WITH OVER TEMPERATURE PROTECTOR, AUTOMATIC THERMOSTAT, TEMPERATURE & PRESSURE RELIEF VALVE.INDIRECT WATER HEATER SCHEDULEEQUIPMENT NOCAPACITY(GAL)RECOVERY (GPH)@115°F DHWNOMINAL MBHINPUT.BOILERCONNECTIONDOMESTIC WATERCONNECTIONMANUFACTURER & MODELOPTIONS/ACCESSORIESWH-153.13781901"3/4"WEIL-MCLAIN: AQUAPLUS 55SEE NOTE 1NOTES:1. PROVIDE WITH 150 PSI PRESSURE RELIEF VALVE.Received 2/22/2016 11:43:24 AM
DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWM1-6AIR COOLED CONDENSING UNIT SCHEDULE (ALTERNATE COOLING FOR MAIN LEVEL)EQUIPMENTNO.SERVICENOMINAL COOLING CAPACITY (BTU/HR)REFRIG. PIPINGELECTRICMANUFACTURER & MODELOPTIONS/ACESSORIESLIQUIDVAPORV/PH/HZMOP (A)MCA (A)CU-4HEAT PUMPS168,0007/8"1-1/8"208/3/6011068MITSUBISHI #PURY-P168SEE NOTES 1 THRU 5NOTES:1. PROVIDE LINE SET AS RECOMMENDED BY MANUFACTURER.2. PROVIDE SNOW/HAIL GUARDS.3. PROVIDE 12" QUICK SLING MOUNTAIN RAILS AND BASE PAN HEATERS.4. OUTDOOR CONDITIONS OF 85 F.5. INDOOR CONDTIONS OF 79 F DB/61 F WB.HEAT PUMP SCHEDULE (ALTERNATE COOLING FOR MAIN LEVEL)EQUIPMENT NO.SERVICETYPECOOLING CYCLEHEATING CYCLEPEAKAIRFLOWCFMREFRIG. PIPINGELECTRICMANUFACTURERMODEL #OPTIONS/ACCESSORIESNOMINAL COOLINGCAPACITY (BTU/HR)AIR TEMPERATURESNOMINAL HEATINGCAPACITY (BTU/HR)AIR TEMPERATURESLIQUIDVAPORV./PH/HZMCA (A)MOCP (A)INDOOR DB/WB (°F)OUTDOOR DB/WB (°F)INDOOR DB (°F)OUTDOOR DB (°F)HP-1OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-2OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-3OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-4OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-5OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-6OFFICE #1WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-7OFFICE #1WALL MTD.18,00079/618520,0007204241/4"1/2"208/1/60115MITSUBISHIPKFY-P18SEE NOTE 1HP-8OFFICE #1WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-9OFFICE #1WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-10OFFICE #1WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-11OFFICE #1WALL MTD.15,00079/618517,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P15SEE NOTE 1HP-12OFFICE #3WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-13OFFICE #3WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-14OFFICE #3WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-15OFFICE #2WALL MTD.18,00079/618520,0007204241/4"1/2"208/1/60115MITSUBISHIPKFY-P18SEE NOTE 1HP-16OFFICE #2WALL MTD.6,00079/61856,7007202081/4"1/2"208/1/60115MITSUBISHIPKFY-P06SEE NOTE 1HP-17OFFICE #2WALL MTD.8,00079/61859,0007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P08SEE NOTE 1HP-18OFFICE #2WALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-19LOBBYWALL MTD.12,00079/618513,5007204131/4"1/2"208/1/60115MITSUBISHIPKFY-P12SEE NOTE 1HP-20LOBBYWALL MTD.30,00079/618534,0007209183/8"5/8"208/1/60115MITSUBISHIPKFY-P30SEE NOTE 1NOTES:1. PROVIDE WITH THERMOSTATS, REFRIGERANT LINE SETS AS RECOMMENDED BY MANUFACTURER, CONDENSATE PUMP, AND FILTER.BRANCH CIRCUIT CONTROLLER SCHEDULE (FOR ALTERNATE COOLING SYSTEM)EQUIPMENTNO.SYSTEM NO.TYPENUMBER OFPORTSLOCATIONELECTRICALDIMENSIONS LxWxHMANUFACTURE & MODELOPTIONS/ACCESSORIESMCAMOCPV./PH./HZ.BC-11MAIN13ABOVE CEILING1.1208/1/6017" x 44" x 12"MITSUBISHI #CMB-P1013NU-GA1SEE NOTE 1BC-1A1SUB8ABOVE CEILING1208/1/6017" x 26" x 12"MITSUBISHI #CMB-P108NU-GB1SEE NOTE 1NOTES:1. PROVIDE WITH CONDENSATE PUMP. PROVIDE BALL VALVES FOR EVERY PORT ON THE BRANCH CIRCUIT CONTROLLER.VRF SYSTEM PIPING/ELECTRICAL SCHEMATICReceived 2/22/2016 11:43:25 AM
EXITMECHANICAL PIPING - UPPER LEVEL FLOOR PLANMP1-1DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:25 AM
MP1-2MECHANICAL PIPING - MAIN LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:25 AM
EXITMP1-3MECHANICAL PIPING - LOWER LEVEL FLOOR PLANDATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWReceived 2/22/2016 11:43:25 AM
MP1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBOILER SCHEDULEEQUIPMENT NO.SERVICEINPUTCAPACITY(MBH)OUTPUTCAPACITY (MBH)BOILER VOLUME (GALLONS)FLUE/COMB. AIRSIZE (INCHES)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESAMPSV./PH./HZ.BL-1RESIDENCE HEAT/DHW29928074/410120/1/60WEIL-MCLAIN, #EVG-299SEE NOTE 1BL-2 & BL-3OFFICE HEAT/DHW &SNOWMELT2201754.64/410120/1/60WEIL-MCLAIN, #EVG-220SEE NOTE 1NOTES:1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUALRESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, BOILER CIRCULATOR, WALL MOUNT KIT, AND BLOWERMOTOR.RADIANT ZONESMANIFOLDNO.# LOOPSLOOPLENGTHAREA SERVEDGPMMF-13257MASTER BEDROOM1.5MF-12221HIS BEDROOM1.0MF-13257LIVING ROOM1.5MF-11144ENTRY0.5MF-13187KITCHEN/DINING1.5MF-12140MUD/LAUNDRY/PANTRY1.0RESIDENTIAL MECHANICAL PIPING DIAGRAMPUMP SCHEDULEEQUIPMENT NO.SERVICELOCATIONGPMHEAT (FT.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESMAX HPWATTSRPMV./PH./HZ.FLACP-1RESIDENCE HEATINGMECH. ROOM8.2331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-2RESIDENCE HEATINGMECH. ROOM8.2331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-3RESIDENCE RADIANT HEAT CIRCULATIONMECH. ROOM7331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-4RESIDENCE DOMESTIC WATERMECH. ROOM8141/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-5OFFICE SPACE HEATINGMECH. ROOM3032-800VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-6OFFICE SPACE HEATINGMECH. ROOM3032-800VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-7SNOWMELT RECIRCULATIONMECH. ROOM9.8331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1NOTES:1. PROVIDE WITH COMMUNICATION MODULE, CAST IRON CASING, ENGINEERED POLYMER IMPELLER, STAINLESS STEEL SHAFT, FLANGED CONNNECTIONS AND ECM MOTOR.Received 2/22/2016 11:43:25 AM
MP1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:100 MAINADDRESSSCALE:AS SHOWN09/04/14PERMIT--BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWOFFICE SPACE MECHANICAL PIPING DIAGRAMHEAT EXCHANGER SCHEDULEEQUIPMENT NO.SERVICEHEATING FLUIDHEATED FLUIDMANUFACTURER & MODELOPTIONS/ACCESSORIESEWT (°F)LWT (°F)GPMΔP (FT)FLUIDEWT (°F)LWT (°F)GPMΔP (FT)FLUIDHX-1SNOWMELT1801309.81.6WATER100140133.5WATER (50% P.G.)TACO, #TB10Tx40NOTES:1.SNOWMELT MANIFOLD PIPING DETAILReceived 2/22/2016 11:43:25 AM
MP1-4DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:ASPEN CLINIC
100 EAST MAIN STREETSCALE:AS SHOWN09/04/14PERMITBUILDING REMODEL
BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBighorn Consulting Engineers, Inc.
Mechanical & Electrical Engineers
569 S. Westgate Dr., Suite 1
Grand Junction, CO 81505
phone: 970-241-8709, fax: 970-241-951412/09/16PERMITBOILER SCHEDULEEQUIPMENT NO.SERVICEINPUTCAPACITY(MBH)OUTPUTCAPACITY (MBH)BOILER VOLUME (GALLONS)FLUE/COMB. AIRSIZE (INCHES)ELECTRICALMANUFACTURER & MODELOPTIONS/ACCESSORIESAMPSV./PH./HZ.BL-1RESIDENCE HEAT/DHW29928074/410120/1/60WEIL-MCLAIN, #EVG-299SEE NOTE 1BL-2 & BL-3OFFICE HEAT/DHW &SNOWMELT2201754.64/410120/1/60WEIL-MCLAIN, #EVG-220SEE NOTE 1NOTES:1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUALRESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, BOILER CIRCULATOR, WALL MOUNT KIT, AND BLOWERMOTOR.RADIANT ZONESMANIFOLDNO.# LOOPSLOOPLENGTHAREA SERVEDGPMMF-13257MASTER BEDROOM1.5MF-12221HIS BEDROOM1.0MF-13257LIVING ROOM1.5MF-11144ENTRY0.5MF-13187KITCHEN/DINING1.5MF-12140MUD/LAUNDRY/PANTRY1.0PUMP SCHEDULEEQUIPMENT NO.SERVICELOCATIONGPMHEAT (FT.)MOTORMANUFACTURER & MODELOPTIONS/ACCESSORIESMAX HPWATTSRPMV./PH./HZ.FLACP-1RESIDENCE/OFFICE HEATINGMECH. ROOM38.2351.09-VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-2RESIDENCE/OFFICE HEATINGMECH. ROOM38.2351.09-VARIABLE115/1/606TACO, #VR20SEE NOTE 1CP-3RESIDENCE RADIANT HEAT CIRCULATIONMECH. ROOM7331/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-4RESIDENCE DOMESTIC WATERMECH. ROOM8141/4-VARIABLE115/1/602.5TACO, #VR3452SEE NOTE 1CP-5OFFICE BASEBOARD HEATINGMECH. ROOM-----115/1/60-CONTRACTOR TO SELECTSEE NOTE 1CP-6RESIDENTIAL FAN COILSMECH. ROOM6350.68-VARIABLE115/1/606TACO, #VR15SEE NOTE 1CP-7SNOWMELT RECIRCULATIONMECH. ROOM13330.68-VARIABLE115/1/606TACO, #VR15SEE NOTE 1NOTES:1. PROVIDE WITH COMMUNICATION MODULE, CAST IRON CASING, ENGINEERED POLYMER IMPELLER, STAINLESS STEEL SHAFT, FLANGED CONNNECTIONS AND ECM MOTOR.HEAT EXCHANGER SCHEDULEEQUIPMENT NO.SERVICEHEATING FLUIDHEATED FLUIDMANUFACTURER & MODELOPTIONS/ACCESSORIESEWT (°F)LWT (°F)GPMΔP (FT)FLUIDEWT (°F)LWT (°F)GPMΔP (FT)FLUIDHX-1SNOWMELT1801309.81.6WATER100140133.5WATER (50% P.G.)TACO, #TB10Tx40NOTES:1.SNOWMELT MANIFOLD PIPING DETAILM. Blaine Buck12/9/16Received 2/22/2016 11:43:25 AM
MP1-5DATE:CHECKED BY:JOB NO:DRAWN BY:DATE:ISSUED FOR:SHEET NUMBER:ASPEN CLINIC
100 EAST MAIN STREETSCALE:AS SHOWN09/04/14PERMITBUILDING REMODEL
BCEBCE05/09/201614-130ASPEN COLORADO02/20/15PERMIT06/17/15PERMIT05/09/16REVIEWBighorn Consulting Engineers, Inc.
Mechanical & Electrical Engineers
569 S. Westgate Dr., Suite 1
Grand Junction, CO 81505
phone: 970-241-8709, fax: 970-241-951412/09/16PERMITBUILDING HEATING BOILER PIPING DETAILM. Blaine Buck12/9/16Received 2/22/2016 11:43:25 AM
´100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
}100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/SignatureL
O
A
D
CAP
WHT
BLK
POWER PACK
BLUBLKREDBRNYELOUTPUT
+24 VDC
COMMON
CONTROL
YEL
VIO
GRN
RED
RED
CAP
Scale: NONE
POWER PACK CONTROL SCHEMATIC3
TYPICAL OCCUPANCY SENSOR AND
AUTOMATIC
LOAD
LOAD
Scale: NONE
SENSOR SWITCH CONTROL SCHEMATIC2
TYPICAL WALL MOUNTED OCCUPANCY
AUTOMATIC AUTOMATIC
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A
C
3 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/SignatureDENTAL EQUIPMENT KEYNOTES:
5 5
3 3
2 2
6 6
4 4
1 1
D
D
C
C
B
B
F
F
E
E
A
A 100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/Signature
100 East Main Street, Aspen, CO, 81611DR.JOHN MILLERTenant Fit-OutSeal/SignatureSCALE: N.T.S.
ELECTRICAL ONE LINE DIAGRAM
PROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :xxxG E N E R A L N O T E SxxxxxxxxxxxxxxxxxxG E N E R A L C O N D I T I O N SP R O J E C T N A M E & L O C A T I O NJOHN D. MILLER DDS.ASPEN ,CO. 81611P R O J E C T T E A MD R A W I N G L I S TS Y M B O L S L E G E N D295 Centerpoint Blvd.Pittston, PA 186401-800-go-bencowww.benco.comW A L L L E G E N D
1DENTAL EQUIPMENT PLANPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :DENTAL EQUIPMENT LEGEND
PROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :1DENTAL CARPENTRY PLAN
CEILING LIGHT TAKES PREFERENCE OVER ALLGENERAL LIGHTING FIXED LIGHT CAN NOT BE MOVEDDETAIL - TYPICAL CEILING LIGHT SUPPORTVERIFY WITH DOCTOR ON HEIGHT OF OUTLETS.... ANALGESIA/VAC/NITROGEN OUTLET BACKINGPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :
1DENTAL ELECTRICAL PLANPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :NOTES LEGENDELECTRICAL LEGENDNOTES LEGEND
WASHER / DRYERXRXCVERIFY WITH DOCTORVERIFY WITH DOCTORNMNAPXCEILING TAKES PREFERENCE OVER ALLGENERAL LIGHTING FIXED LIGHT CAN NOT BE MOVEDTYPICAL CEILING MOUNTED LIGHT PAN X-RAY WIRINGEBNAPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :
1DENTAL PLUMBING PLANPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :SINK LEGEND
VACUUM OUTLETVERIFY OUTLET HEIGHTS WITH DOCTORVERIFY OUTLET HEIGHTS WITH DOCTORAND BENCO REP.......PROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :
1INTERIORS PLANPROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :
PROJECT # :DRAWN BY :ISSUED :DATE :CHECKED BY :DRAWING TITLE :SHEET :PROJECT NAME & LOCATION :