Loading...
HomeMy WebLinkAboutFile Documents.520 W Hallam St.0041.2018 (22).ARBK0041.2018.ARBK_BuildingComment1 Subject: PlanCheck Page Label: A1.07 PROPOSED PLANS Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Provide a cutsheet on the skylight showing compliance with IRC 308.6 for material and required curb height. 520 W HALLAM ARCHITECTURAL SET.pdf (8) Subject: PlanCheck Page Label: A1.10 PROPOSED ELEVATIONS Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Provide the installation manual for this DV fireplace to show you are allowed to vent this close to operable windows (scales at 2'4" from the awning window). Subject: PlanCheck Page Label: A1.10 PROPOSED ELEVATIONS Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Please clarify what is intended at this guardrail. Is it 1' wide metal panels with 2" spacing between them? If it is the other way around it will not comply with IRC 312.1.3 but it is hard for me to tell as the panels appear to be transparent as drawn. Subject: PlanCheck Page Label: A1.10 PROPOSED ELEVATIONS Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Window fall protection required per IRC 312.2 req'd. Note this requirement on the window schedule. Subject: PlanCheck Page Label: A1.12 WINDOW SCHEDULE Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf This window is required to be safety glazed per its proximity to the bathtub. Please identify it as such. 206 ROOF SKYLIGHT E K 4'-9 1/4"5'-2 3/4" CL 5 U Provide a cutsheet on the skylight showing compliance with IRC 308.6 for material and required curb height. T.O. F.F. @ MAIN LEVEL (E) ELEV. 100'-0" T.O. F.F. @ UPPER LEVEL (E) ELEV. 108'-10 3/4" V.I.F. T.O. F.P. MONTIGO PL52 2'-6"ELEV. 33.25" + 26" = 59 1/4"1'-0"6'-4"10 3/4"1'-0"VERIFY W/FIREPLACE MFG.5'-10"EXTERNAL POWER VENT- REF. FIREPLACE MFG. FRAMING ALLOWANCE - REF.FIREPLACE MFG. AND STRUCTURAL 1 11 2 2 3 9 DASHED LINE OF FOUNDATIONBEYOND 12 Provide the installation manual for this DV fireplace to show you are allowed to vent this close to operable windows (scales at 2'4" from the awning window).2'-6"T.O. F.F. @ MAIN LEVEL (E) T.O. F.F. @ UPPER LEVEL (E) ELEV. 108'-10 3/4" V.I.F. NEW SIDING TO MATCH EXISTING 1 14 6 8 8 10 11 11 V Please clarify what is intended at this guardrail. Is it 1' wide metal panels with 2" spacing between them? If it is the other way around it will not comply with IRC 312.1.3 but it is hard for me to tell as the panels appear to be transparent as drawn. T.O. F ELEV T.O. F ELEV 1'-0"10 3/4"1'-0"VERIFY W/FIREPLACE MFG.5'-10"EXTERNAL POWER VENT- REF. FIREPLACE MFG. FRAM ALLO FIREP AND 1 2 2 3 4 3 8 12 Window fall protection required per IRC 312.2 req'd. Note this requirement on the window schedule.1'-0"K CURB MOUNTED FIXED SKYLIGHT VERIFY SIZE AND STYLE WITH MFG. VERIFY 4'-0"VERIFY5'-0"L 3 UNITS MULLED TOGETHER (1) FIXED AND (2) AWNING W/ INT. SCREEN FOR OPERABLE UNIT REF. ELEV. FOR SWING NOTE: REPLACEMENT WDW. WITHIN 6'-0"3'-6"1'-6"5'-0"3'-0"3'-0"F THIS INFORMATION MAY BE USED OR COPIED WITHOUT THE PRIOR WRITTEN PERMISSION OF CONSORTIUM ARCHITECTS. 520 W HA 520 W. HA BLOCK PARCE This window is required to be safety glazed per its proximity to the bathtub. Please identify it as such. 04/06/2018 Subject: PlanCheck Page Label: A1.13 DOOR SCHEDULE Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Verify that the custom door will be NFRC labeled at inspection in order to verify U value. Subject: PlanCheck Page Label: A1.14 ROPOSED LIGHTING & ELECTRICAL PLAN Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf This is a commercial code requirement/reference, please remove it from all lighting schedules. Subject: PlanCheck Page Label: A1.17 DETAILS Author: justinh File Name: 520 W HALLAM ARCHITECTURAL SET.pdf Provide an assembly detail for the new flat roof that is proposed. Provide documentation that this new assembly is class A (UL listing, ESR report, etc). Subject: PlanCheck Page Label: 5 Author: justinh File Name: 520 W HALLAM STRUCTURAL SET.pdf A signed special inspection agreement is required for the welding shown in the structural details. 520 W HALLAM STRUCTURAL SET.pdf (1) 3'-0"2'-6" OWNER SPECIFIED CUSTOM DOOR Verify that the custom door will be NFRC labeled at inspection in order to verify U value. TOTAL FIXTURES GENERAL NOTES: ALL LIGHTING SHALL COMPLY WITH 2014 NEC, 2015 IECC, PROVIDE LIGHT REDUCTION CONTROLS PER 2015 IECC C405.2.2.2 ALL BULBS ARE TO BE 12W LED ONMIDIRECTIONAL BULBS, UNLESS NOTED OTHERWISE TOTAL PERCENTAGE HIGH EFFICIENCY PER 2015 IECC R404.1 : G H J K L M N P R Q S SUBTOTAL T U TBD TBD LED CABLE LIGHTING TBD LED TRACK LIGHTING TBDTBDTBD This is a commercial code requirement/reference, please remove it from all lighting schedules. Provide an assembly detail for the new flat roof that is proposed. Provide documentation that this new assembly is class A (UL listing, ESR report, etc). COAT PO BASEPLATE & GRADE W/ EXIST B A signed special inspection agreement is required for the welding shown in the structural details. 04/06/2018