Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
File Documents.121 E Hyman Ave.0149.2018 (21).ARBK
CAYTON RESIDENCE 121 EAST HYMAN AVENUE, ASPEN, CO PERMIT SET MAY 22, 2018 NOTES IECC COMPLIANCE SPECIFICATIONS LIGHTING PLANS ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 5/23/2018 CAYTON RESIDENCE MAY 22, 2018 PERMIT SET ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 2 GENERAL NOTES 1. It is the responsibility of the electrical contractor to review all lighting plans prior to commencement of electrical work. Any interpretation of the drawings shall be confirmed by Robert Singer and Associates, Inc. 2. All work must be in complete accordance with NEC and all governing authorities having local jurisdiction. 3. All site specific conditions to be field verified by contractor prop to purchase and installation of fixtures. 4. All outlets and fixtures to be grounded. 5. All recessed fixture trims to be painted to match ceiling color and finish unless otherwise specified. 6. It is the responsibility of the electrical contractor to refer to most recent fixture schedule, control schedule and specifications issued with most recent drawings or revision sketches. RECESSED HOUSINGS 1. Expanding foam insulation should be kept a minimum of three inches from recessed light fixtures. Acceptable installations include, but are not limited to, masking the fixture by wrapping it in fiberglass batting or building a box around it. 2. Since spray-in foam expands into all openings and cracks care must be taken to prevent encroachment of the foam to within three inches of the fixture and junction box. The foam expansion may generate significant force as it cures so the masking must either be strong enough to resist the expansion or allow enough room for some expansion while still providing the three inch minimum spacing. 3. The installer is responsible for installing the IC rated recessed fixture in a manner that provides a minimum of three inches air space around the fixture to ensure that the insulation does not cause overheating of the luminaire or penetrate into the fixture and junction box. DIMENSIONS 1. All wall sconce heights, both interior and exterior to be determined upon review of fixture selection and architectural elevations if not noted. 2. Fixture type ‘SA’ (Swing Arm) mounted height to be determined upon review of fixture selection and architectural elevations. Swing arms to be switched or controlled as indicated on plans. 3. Electrical contractor is to refer to all exact dimensioning and centerlines for fixture locations. 4. All dimensions and centerlines based off of Architectural plans and may not reflect exact site conditions, contact Robert Singer and Associates if in question. 5. General contractor to refer to dimensioned lighting plans prior to framing. General contractor to coordinate framing and structural conditions with lighting, MEP, AV and other trades. 5/23/2018 CAYTON RESIDENCE MAY 22, 2018 PERMIT SET ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 3 EXTERIOR/SITE LIGHTING 1. All exterior façade mounted receptacles for seasonal lighting shall be weatherproof while in use GFCI. Exact location of receptacles to be coordinated with architect and shall be in concealed location. 2. Electrical contractor to provide conduit routing to locations indicated on plans terminating in direct burial junction boxes for all landscape and site lighting. 3. Electrical contractor to determine locations of direct burial transformers if needed. 4. Prior to rough-in, exact fixture locations to be flagged and coordinated on site after all landscaping is complete. 5. Architect and landscape architect to inform Robert Singer and Associates of any exterior structures such as retaining or perimeter walls and steps in which lighting is to be incorporated prior to construction work. 6. Landscape and site lighting plan to be generated upon review of complete landscaping plans and details provided by architect and landscape architect. INTERIOR SWITCHING 1. Robert Singer and Associates recommends standard toggle and dimmer switches to be mounted at 48”AFF to centerline of switch, and 4” off door bucks or corners, except where noted. Exact locations of all devices to be approved by architect/interiors and owner prior to rough-in. 2. Robert Singer and Associates plans indicate switch designations, (IE; d – dimmer, door – door jamb switch, 3 – 3-way switch, 3d – 3 way dimmer switch, vs – vacancy sensor). Refer to legend for all designations. 3. 3-way switching to be wired as per plan. 4. All standard toggle switches and dimmer switches to be as specified. 5. Finishes for all standard toggle switches, dimmers, and faceplates to be determined by architect/ interiors and owners. 6. Switched receptacle notes: a. Half switched TL/FL indicates control of at least (1) outlet on any standard receptacle. Control of outlet either by control system or standard switch. Electrical contractor to verify number and location of switched outlets on receptacle with Robert Singer and Associates, architect/interiors and owner. b. Fully switched TL/FL indicates control of all outlets on any standard receptacle. Control of outlet either by control system or standard switch. c. The controlled outlet on the receptacle shall be clearly marked by electrical contractor. d. Exact locations of all switched receptacles, both floor and wall mounted, to be coordinated with furniture plans, Electrical plans, and be approved by architect/interiors prior to rough-in. e. Electrical contractor/Electrical engineer to refer to Robert Singer and Associates lighting plans for switched receptacle locations prior to layout of code required receptacles. 5/23/2018 CAYTON RESIDENCE MAY 22, 2018 PERMIT SET ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 4 CONTROL SYSTEMS 1. Control system specifications to be confirmed with manufacture. 2. Exact style, faceplate finish, button color, text and configuration for all control stations to be reviewed and approved by owner/ architect/ interiors prior to Robert Singer and Associates release for production. 3. Robert Singer and Associates recommends all control wall stations to be mounted at 54”-60”AFF to centerline of station. Exact height to be reviewed and approved by owner/ architect/ interiors prior to rough-in. 4. Exact enclosure and control locations indicated on plan to be coordinated with AV, Mechanical and Electrical, and approved by architect/engineer prior to rough-in. 5. Multiple enclosure locations to be linked to control location with manufacturer recommended control wire. 6. All information regarding motorized functions to be controlled via the control system shall be submitted to Robert Singer and Associates for coordination. 7. RSA to be provided with all network information for remote access to service lighting control system upon commissioning of system. If no VPN is available, RSA will need to be on-site for any lighting control system revisions. 8. CATV or better communications wire to be run from Lutron processer location to local network hub. DECORATIVE FIXTURES 1. Refer to fixture specifications for maximum wattage and of decorative fixtures. Interiors/ owners to notify Robert Singer and Associates if maximum wattage is exceeded. 2. Interiors/ owners to provide complete decorative fixture schedule to Robert Singer and Associates prior to installation. 3. Interiors/ owners to notify Robert Singer and Associates if deviating from decorative fixture selection guide (i.e. electronic low voltage transformers, fluorescent ballasts, LED lamping). 4. Interiors/ owner to coordinate decorative fixture weight with general contractor to ensure adequate blocking for mounting of fixture. ON-SITE AIMING/LAMPING 1. Robert Singer and Associates to provide electrical contractor with exact lamping schedule and plans for all architectural light fixtures. 2. Robert Singer and Associates to provide electrical contractor with preliminary aiming guide for reference prior to final adjustments. 3. Electrical contractor to provide the necessary equipment (i.e. extra lamps, ladders, scaffold and coordination of lifts if needed) and personnel for final aiming/ adjustments of lighting fixtures. Final adjustments to be made after all artwork and furnishings have been placed. 5/23/2018 CAYTON RESIDENCE MAY 22, 2018 PERMIT SET ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 5 SUBSTITUTIONS 1. No specifications are to be substituted without approval by Robert Singer and Associates. Any proposed substitutions are to be issued to Robert Singer and Associates for review. 2. Robert Singer and Associates assumes no responsibility for any unapproved changes to the issued set of lighting plans or specifications. 5/23/2018 CAYTON RESIDENCE MAY 22, 2018 PERMIT SET ROBERT SINGER & ASSOCIATES INC. DESIGN CONSULTANTS LIGHTING SPECIALISTS Corporate Member IALD, IES T 970_963_5692 www.robertsingerlighting.com 6 5/23/2018 Permit: 5/18/2018 Cayton Residence Type Image Product / Manufacturer Attributes Notes BC Element Lighting "Adjustable Low Profile Wet Listed Downlight" Description: Adjustable Low Profile Wet Listed Downlight Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S-L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming Voltage: 120V Ceiling Type: Plaster Trimless fixture, refer to installation instructions. Contractor to remove and paint trim to match ceiling color. Length: 17.5" Width: 11.5" Height: 4" Trim Size: 3.2" Aperture: 1.7" SL Lucifer Lighting "Steplight" Description: Impact Recessed Luminaire Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC Dimming Type: LED Reverse or Forward Phase Driver: Remote Dimmable Power Supply Remote power supply location by EC. Max. 12 fixtures per power supply. Depth: 1.61" Width: 2.59" Height: 2.75" XD2.3 Tech Lighting "Tech Pitch Sconce" Description: Tech Pitch Sconce - Wet Location Catalog #: 700WSPITS*-LED830 Lamping: 22W; 495Lumen; 80+CRI; 3000K Location: Exterior Lower Garage Quantity: 2 Mounting Height: To Be Coordinated Width: 5" Height: 5" Depth: 3.9" XD2.1 Feiss "Exterior Decorative Sconce" Description: Decorative sconce - wet location Catalog #: Urbandale - OL13703ANBZ-L1 Lamping: 26W LED; 1915Lumens; 90CRI Location: Entry Quantity: 1 Mounting Height: TBD Exact fixture to be approved by Owner. Fixture shall be of similar style and shall be fully shielded. Width: 10" Height: 23" Depth: 8" XD2.2 Feiss "Exterior Decorative Sconce" Description: Decorative sconce - wet location Catalog #: Urbandale - OL13701ANBZ-L1 Lamping: 14W LED; 1000Lumens; 90CRI Location: Garage and Side Entry Quantity: 3 Mounting Height: TBD Exact fixture to be approved by Owner. Fixture shall be of similar style and shall be fully shielded. Width: 80" Height: 13" Depth: 6" RSA 970-963-5692 www.robertsingerlighting.com, Basalt, CO 5/23/2018 Type Image Product / Manufacturer Attributes Notes EXT1 WAC Lighting "Ingrade path fixture" Description: InGrade Round Path Fixture Catalog #: 2091-30-** Lamping: 4.1W; 5Lumen; 3000K; 85 CRI Voltage: 9-15VAC Dimming Type: MLV Dimming Driver: Remote Magnetic Length: 2-3/4" Width: 2-3/4" Height: 3-1/4" RSA 970-963-5692 www.robertsingerlighting.com, Basalt, CO 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 1 of 6 ELEMENT-lighting.com 3" LED LOW-PROFILE ADJUSTABLE DOWNLIGHT HIGH OUTPUT (AT 3000K) LOW OUTPUT (AT 3000K) WARM DIM HIGH LOW DELIVERED LUMENS 1811 1476 1319 1124 1320 900 WATTS 18 18 12 12 18 12 EFFICACY 100 82 110 94 73 75 CRI 80+ 90+ 80+ 90+ 90+ 90+ CBCP 10º - 19,414; 15º - 5848; 25º - 5416; 40º - 3369 CCT OPTIONS 2700K, 3000K, 3500K, or Warm Color Dimming (3000K-1800K)*** VOLTAGE 120V or 277V DIMMING*TRIAC, ELV, 0-10V POWER SUPPLY Constant Current: driver with +.9 power factor and +80% efficiency OPTICS Field Changeable: 10º, 15º, 25º, 40º TIR ADJUSTABILITY Lockable hot-aiming 0-40º tilt, 361º rotation CEILING APPEARANCE Flanged (Accommodates up to 2.5" ceiling thickness) or Flangeless CEILING APERTURE 3-7/8" ceiling cut-out HOUSING IC Airtight, Non-IC Airtight, Chicago Plenum. IC suitable up to R60 spray foam insulation. CONSTRUCTION Housing: Heavy gauge cold rolled steel Trims: Die cast aluminum FINISH Housing: Black powder coat Trims: Antique Bronze, Black, Satin Nickel, White (paintable) GENERAL LISTING ETL listed. Damp listed. Shower version wet listed. CALIFORNIA TITLE 24 Registered CEC Appliance Database. Can be used to comply with CEC 2016 Title 24 Part 6 for 90 CRI versions. LED LIFETIME L70; 50,000 hours WARRANTY**5 years *See ELEMENT-lighting.com for dimmer compatibility. Consult Quotes Dept for alternate or custom driver selections. **Visit ELEMENT-lighting.com for specific warranty limitations and details. ***Warm color dimming not available with 10º optics. Accepts two optical controls and an optional trim-mounted lens. • Lockable tool free hot-aiming with 0-40º tilt and 361º rotation • Trims are die cast aluminum and matches ELEMENT 3" series • Lensed and shower aperture includes Solite™ soft focus lens • Includes integral junction box approved for branch circuit through wiring The ELEMENT 3" LED Low-Profile Adjustable Downlight provides a beautiful architectural appearance and high performance for shallow ceiling plenum installations. Designed with a shallow 4" housing and utilizing the same trim pieces as the rest of the ELEMENT 3" series, it can be used in conjunction with the entire 3" family and remain undetectable. Ideal for space constrained environments such as elevators and healthcare soffits. Complete adjustability allows for lockable hot aiming with 0°-40° tilt and 361° rotation, eliminating deadspots. Wood ceiling option allows for a smooth, flangeless appearance using any flangeless trim. SPECIFICATIONS shown in flanged bevel square 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 2 of 6 ELEMENT-Lighting.com ELEMENT-lighting.com 3" LED LOW-PROFILE ADJUSTABLE DOWNLIGHT 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 4.3" 109 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 4.3" 109 mm 43 mm 1.7" 43 mm 1.7" 4.3" 109 mm 3.2" 81 mm 4.3" 109 mm 43 mm 1.7" 3.2" 81 mm 11.5" 292 mm 17.5" 446 mm 7" 178 mm 4" 102 mm 4" 102 mm 3.68" 93.5 mm TRIMS 3" HOUSING FLANGELESS BEVEL FLANGELESS BEVEL FLANGED BEVEL FLANGELESS FLAT FLANGED FLAT FLANGED BEVEL FLANGELESS FLAT FLANGED FLAT FINISH ANTIQUE BRONZE BLACK SATIN NICKEL WHITE (PAINTABLE) ROUND SQUARE IC / NON-IC / CHICAGO PLENUM 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 3 of 6 ELEMENT-Lighting.com ELEMENT-lighting.com 3" LED LOW-PROFILE ADJUSTABLE DOWNLIGHT .85" 22 mm 1.5" 38 mm .625" 16 mm 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" 3.2" 81 mm 43 mm 1.7" WOOD CEILING FLANGELESS OPTIONS / FLANGELESS TRIMS ADJUSTABLE TRIM ADAPTER FLANGELESS BEVEL (ANTIQUE BRONZE) FLANGELESS BEVEL (SATIN NICKEL) FLANGELESS BEVEL (ANTIQUE BRONZE) FLANGELESS FLAT (ANTIQUE BRONZE) FLANGELESS FLAT (ANTIQUE BRONZE) FLANGELESS BEVEL (SATIN NICKEL) FLANGELESS FLAT (SATIN NICKEL) FLANGELESS FLAT (SATIN NICKEL) FINISH ANTIQUE BRONZE BLACK SATIN NICKEL WHITE (PAINTABLE) ROUND SQUARE INSTALL PRIOR TO CEILING TRIM ADAPTER INSTALLED ADAPTER FLUSH HOUSING TRIM ADAPTER TRIM ADAPTER HOUSING COLLARHOUSING COLLAR TRIM ADAPTER ADAPTER EXTENDED HOUSING HOUSING COLLAR Wood ceiling housings (“WC” designation in the ordering grid) ship with an adjustable trim adapter that inserts into the housing aperture and allows standard ELEMENT 3" flangeless trims to achieve a truly flangeless, flush ceiling appearance in special applications such as wood or stone installation. For use in new construction. Consult installation instructions regarding plenum requirements and ceiling thickness ratios. 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 4 of 6 7400 Linder Avenue, Skokie, Illinois 60077 T 847.410.4400 F 847.410.4500 FIXTURE TYPE & QUANTITY PROJECT INFO JOB NAME & INFO NOTES © 2017 Tech Lighting, L.L.C. All rights reserved. The “Tech Lighting” graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification. ELEMENT-lighting.com ELEMENT-Lighting.com3" LED LOW-PROFILE ADJUSTABLE DOWNLIGHT TRIM PRODUCT SERIES CEILING APPEARANCE STYLE APERTURE FINISH E3R ELEMENT 3" ROUND E3S ELEMENT 3" SQUARE L FLANGELESS F FLANGED UP TO 1" CEILING THICKNESS F15 FLANGED 1.1"-1.5" CEILING THICKNESS F20 FLANGED 1.6"-2.0" CEILING THICKNESS F25 FLANGED 2.1"-2.5" CEILING THICKNESS B BEVEL F FLAT -O NO LENS -H SHOWER -L LENSED Z ANTIQUE BRONZE B BLACK S SATIN NICKEL W WHITE - WOOD CEILING OPTION ACCOMMMODATES FLANGELESS TRIMS ONLY. REPLACEMENT OPTICS BEAM SPREAD 351LEDHIOPT 15 15º 25 25º 40 40º 351LEDHIOPT HOUSING PRODUCT SERIES CEILING APPEARANCE LAMP CRI/CCT BEAM SPREAD FUNCTION HOUSING RATING DRIVER VOLTAGE E3R ELEMENT 3" ROUND E3S ELEMENT 3" SQUARE LF FLANGELESS FF FLANGED WC WOOD CEILING* -LH CITIZEN HIGH OUTPUT -LO CITIZEN LOW OUTPUT 827 80 CRI, 2700K 830 80 CRI, 3000K 835 80 CRI, 3500K 927 90 CRI, 2700K 930 90 CRI, 3000K 935 90 CRI, 3500K WD 90 CRI WARM DIM 3000-1800K 0 10º** 1 15º 2 25º 4 40º A ADJUSTABLE S SHALLOW IC/NON-IC AIRITGHT CS CHICAGO PLENUM SHALLOW STANDARD ELV (LEAVE BLANK) -010 0-10V DIMMING 120 VOLT (LEAVE BLANK) -277 277 VOLT -A TRIMS ARE REQUIRED AND MUST BE ORDERED SEPARATELY. *WOOD CEILING OPTION ACCOMMODATES FLANGELESS TRIMS ONLY. **NOTE: 10° OPTIC HAS A UNIQUE LED MODULE NOT AVAILABLE WITH WARM DIM. CHANGING OPTICS TO 15°, 25°, OR 40° WILL REQUIRE A NEW LED MODULE. GRIDS 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 5 of 6 ELEMENT-lighting.com ELEMENT 3" MUD PLATES Die-cast features • Durable die-cast design eliminates warping for a smooth, seamless appearance • Counter-sunk screw holes simplify mudding and sanding • Integrated gunsights ensure optimal trim alignment • Cardboard inserts protect housing from dust and plaster (used with all ELEMENT applications) Creating a smooth transition from ceiling to downlight trim is dependent on an essential, though seemingly simple installation piece. The mud plate (or plaster plate) is the bridge that creates the flangeless appearance from below the ceiling and allows plaster to be applied up to and around the trim aperture. Designing a mud plate that is durable and integral to the housing is critical for a beautiful ceiling finish. No seams. No cracks. No flexing. 3" ROUND DIE-CAST MUD PLATE INSTALLED The standard 3" aperture die-cast mud plate (also standard on Multiples and BYOM housings) creates a tight, inflexible bond with the housing. The robust design requires wider plaster feathering with less potential for cracking. 3" ROUND SHEET-METAL MUD PLATE INSTALLED Sheet-Metal mud plates (standard on 4" and 2" housings, optional for 3" housings) allow for less plaster feathering in tightly configured downlight installations. Sheet metal features • Optional, thinner, meshed sheet-metal mud plates available for minimized plaster feathering to meet installer preference • Cardboard inserts protect housing from dust and plaster (used with all ELEMENT applications) 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: E3S-LF-LH930-*-A-S; 150E3STPPLT-W; E3S- L-B-H-W Lamping: 18W, 1476 Lumens, 90+ CRI, 3000°K LED Dimming Type: Phase Dimming TYPE: BC Page: 6 of 6 7400 Linder Avenue, Skokie, Illinois 60077 T 847.410.4400 F 847.410.4500 FIXTURE TYPE & QUANTITY PROJECT INFO JOB NAME & INFO NOTES © 2017 Tech Lighting, L.L.C. All rights reserved. The “Tech Lighting” graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification. ELEMENT-lighting.com ELEMENT-Lighting.comELEMENT 3" MUD PLATES 7" 178 mm 7" 178 mm 3.8" 97 mm 7" 178 mm 7" 178 mm 3.8" 97 mm 4.9" 124 mm 4.9" 124 mm 4.9" 124 mm 4.9" 124 mm PLASTER PLATES ITEM # DESCRIPTION SHAPE COMPATIBILITY 150E3RTPPLT-W 3" NEW CONSTRUCTION THIN PLASTER PLATE ROUND USED TO CONVERT 3" UNITS INTO FLANGELESS 150E3STPPLT-W 3" NEW CONSTRUCTION THIN PLASTER PLATE SQUARE USED TO CONVERT 3" UNITS INTO FLANGELESS 150E3SPPLT-W 3" NEW CONSTRUCTION PLASTER PLATE SQUARE USED TO CONVERT 3" UNITS INTO FLANGELESS 150E3RPPLT-W 3" NEW CONSTRUCTION PLASTER PLATE ROUND USED TO CONVERT 3" UNITS INTO FLANGELESS GRIDS ROUND DIE-CAST*SQUARE DIE-CAST* 3" PLASTER HOUSING ROUND SHEET METAL SQUARE SHEET METAL 3" HOUSING *Die-cast ships standard with flangeless housing 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: 2091-30-** Lamping: 4.1W; 5Lumen; 3000K; 85 CRI Voltage: 9-15VAC TYPE: EXT1 Page: 1 of 2 Fixture Type: Catalog Number: Project: Location: WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER 27, 2017 2:51 PM waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 2" INGROUND SINGLE APERTURE 2091 ORDERING NUMBER Color Temp Finish 2091-30 3000K BS SS Bronzed Stainless Steel Stainless Steel PRODUCT DESCRIPTION Landscape 2" recessed inground luminaire washes walkways with a shadow-free smooth llumination. FEATURES • Factory sealed water tight xtures • Cold Weather Start: -40C to 50C • Solid stainless steel construction • Available Concrete Pour Adapter • Spring clip, 6' lead wire and direct burial gel lled wire nuts included SPECIFICATIONS Input: Power: Brightness: Color Temp: CRI: Rated Life: 9 - 15VAC (Transformer is required) 4.1W / 6.6VA 5 lm 3000K 85 70,000 hours 2091-30____ Example: 209130SS 2 w" IEC safety Standard Walk over Drive over Resistance to static load test Yes (1125lbs)Yes (4496lbs) Resistance to torque and shear loads test N/A Yes 1 d" 38" 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: 2091-30-** Lamping: 4.1W; 5Lumen; 3000K; 85 CRI Voltage: 9-15VAC TYPE: EXT1 Page: 2 of 2 WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. NOVEMBER 27, 2017 2:51 PM waclighting.com Phone (800) 526.2588 Fax (800) 526.2585 Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050 Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122 Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760 WAC Lighting xtures are compatible with a variety of dimmers. For your convenience we have included a compatibility chart showing dimmers which have been tested with our products. The recommended list below is based upon testing conducted in a lab, and the results can vary in certain eld applications due to a number of factors. Exclusion from the list does not imply incompatibility, just that it has not been tested by WAC Lighting. Please reference the dimmer manufacturer’s instructions for installation, or contact a WAC lighting professional at 800-526-2588. *Low end of this range is determined by output current which may not directly translate to the perceived light output TESTED MAGNETIC LOW VOLTAGEMLV DIMMERS Luminaire Dimmer Manufacturer Family Model Power Rating Range*Note 2091 Lutron Diva DVLV-600 600W 20% - 100% Skylark SLV-600P 600W 15% - 100%Best performance Skylark S-10P 1000W Not recommended Magnetic Transformers Stainless Steel, 12-15V output, IP65 rated, UL 1838 listed See transformer spec sheet for details and its accessories 9075-TRN-SS 75W Max 9150-TRN-SS 150W Max 9300-TRN-SS 300W Max 9600-TRN-SS 600W Max 2" Concrete Pour Kit For installation in concrete. Use with a 4" outdoor rated junction box Order complete kit Order components separately 2000-CON-PVC Concrete Pour Kit 2” INGROUND SINGLE APERTURE 2091 2000-PC-B Concrete Pour Base 2000-PVC-P Concrete Pour Pipe Schedule 40 PVC 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC TYPE: SL Page: 1 of 5 pg. 1[PH] +1-210-227-7329 [FAX] +1-210-227-4967 ©2017 Lucifer Lighting Company As part of its policy of continuous research and product development, the company UHVHUYHVWKHULJKWWRFKDQJHRUZLWKGUDZVSHFLéFDWLRQVZLWKRXWSULRUQRWLFH luciferlighting.com [DATE OF REV: 111017] ISL1 IMPACT STEPLIGHT In-wall 3.4-watt DC LED path or step light. Wide low-glare aperture projects light 4’ at 4’ width delivering minimum 1 fc up to 10 fc. Creats discreet path lighting for residential, commercial and hospitality applications. Durable precision milled 316 stainless steel or brass casting. 80+ CRI, delivering 43 lumens. Available in 2700K, 3000K, 3500K & 4000K color temperatures. Dry / Damp and Wet location. IMPACT ISL1-LED RECESSED LED LUMINAIRE PATH & STEPLIGHT ORDERING INFORMATION - FIXTURE PERFORMANCE LUMINAIRE PERFORMANCE LED &RQéJXUDWLRQ Delivered L.umens lm Power Consumption W Luminous (IéFDF\ lm/ W 80L-02B 43 3.4 12.6 WET OR DRY / DAMP LOCATION SSL-UMP Universal Mounting Plate SSL-MP-(1.50 / 1.75 / 2.00 / 2.50 / 3.00) Mounting Plate; specify collar depth SSL-BB Back Box with SSL-UMP mounting plate SSL-BB-(1.50 / 1.75 / 2.00 / 2.50 / 3.00) Back Box with SSL-MP mounting plate; specify collar depth 66/60%êQLVK Surface Mount Box; specify finish, powder coat only DRY / DAMP LOCATION ONLY SSL-RM Remodel-Mount collar (drywall / plasterboard) SSL-CC Cavity Collar SSL-SC3 Stud-Mount collar (3”) SSL-SC6 Stud-Mount collar (6”) MOUNTING OPTIONS FOR REMOTE POWER SUPPLY - SELECT ONLY ONE (SEE PAGE 3 FOR MOUNTING PROVISION DETAILS) 80L 02B CRI / LED 80L 80+ CRI CCT 1 2700K 2 3000K 3 3500K 4 4000K C Custom Color (gel) 3 3 Custom gels assigned unique suffix upon receipt of order SOURCE LUMENS 02B 200lm RATING 1 Dry / Damp (Non-Locking) 2 Wet (Locking) POWDER COAT FINISH WH White BK Black AG Satin Silver AB Architectural Bronze CF Custom Finish 1 NATURAL FINISH IG Industrial Gray SS Brushed Stainless Steel BR Brushed Bronze NB Natural Bronze PLATED FINISH CH Chrome PB Polished Oil-Rubbed Bronze 2 MB Matte Oil-Rubbed Bronze 2 1 Powder coat only, no plated finishes; custom finishes assigned unique suffix upon receipt of order, consult factory for additional cost2 Dry / Damp location only Designates Quick Ship product. Add “-QS” at end of model number to have up to 100 units shipped within 10 business days. Non- Quick Ship offerings have 3-4 week lead time. 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC TYPE: SL Page: 2 of 5 pg. 2[PH] +1-210-227-7329 [FAX] +1-210-227-4967 ©2017 Lucifer Lighting Company As part of its policy of continuous research and product development, the company UHVHUYHVWKHULJKWWRFKDQJHRUZLWKGUDZVSHFLéFDWLRQVZLWKRXWSULRUQRWLFH luciferlighting.com [DATE OF REV: 111017] IMPACT ISL1 AT2 JCT Universal Junction Box with integral power supply POWER SUPPLY AT2 LTF 0-10V Analog and Leading / Trailing edge (supports 1 - 12 fixtures) MOUNTING OPTIONS HGR Hanger Bars BKT Brackets INPUT VOLTAGE 1 120 Volt 3 277 Volt INSTALL TYPE SL1 Universal Back Box with fixture mounting and integral power supply POWER SUPPLY OPTIONS UBB 24V 60 OUTPUT VOLTAGE 24 Volt WATTAGE 60 Watts UNIVERSAL BACK BOX CONSTRUCTION Stealth&DVWVWDLQOHVVVWHHORUEUDVVGHSHQGLQJRQéQLVK Mounting Plates and Mounting Collars: Stainless Steel. Single-gang Weatherproof Box: Aluminum. Surface Mount Box: Aluminum. Universal Back Box: Polycarbonate. LED Proprietary 2 step MacAdam ellipse LED module available with 80+ CRI in color temperatures of 2700K, 3000K, 3500K and 4000K. Average rated lamp life: 50,000 hours. DIMMING PROTOCOL LTF 0-10V analog and Leading / Trailing edge (AT2) dims to nominal 10%. Lutron 2-wire (L22) and Lutron 3-wire (L32) dims to 1%. eldoLED LINEARdrive (EX2 & ED3) dims to 0%. Lutron Premier (LP1) dims to 0.1% and features Soft-On, Fade-to-BlackTM. RECOMMENDED SPACING Optimum 18” (457mm) above walking surface; 36” (914mm) on-center spacing. ELECTRICAL /XPLQDLUHUHTXLUHVIDFWRU\VXSSOLHG9ROW'&SRZHUVXSSO\ May be integral to back box or remote. Secondary run lengths vary depending on SRZHUVXSSO\VSHFLéHGVHHLQVWDOODWLRQJXLGHOLQHVIRUUXQOHQJWKV LISTING cTUVus Listed; Dark-Sky approved; Patent No. US D610,734 S; Dry / Damp (IP54 rated) and Wet (IP65 rated) location. WARRANTY Manufacturer’s 1-year warranty guarantees product(s) listed to be free from defects in material and workmanship under normal use and service. 5-year warranty on LED and power supply to operate with 70% RIWKHRULJLQDOêX[DQGUHPDLQZLWKLQDUDQJHRIGXY:DUUDQW\SHULRG begins from the date of shipment by Seller and conditional upon the use of manufacturer-supplied power supply. Consult website for full warranty terms and conditions. TECHNICAL PSA-24V-60-1EL2 Plug-in 120V Class 2 power supply (Supports 1-12 fixtures) PSA 24V 60 60 Watts POWER SUPPLY ASSEMBLY OUTPUT VOLTAGE 24 Volt 66 66 Watts 96 96 Watts WATTAGE 40 40 Watts 40 40 Watts AT2 LTF 0-10V Analog and Leading / Trailing edge (supports 1 - 12 fixtures) EX2 eldoLED LINEARdrive, DMX (supports 1 - 18 fixtures) ED3 eldoLED LINEARdrive, DALI (supports 1 - 18 fixtures) LP1 Hi-lume Premier, EcoSystem / 3-wire (supports 1 - 26 fixtures) POWER SUPPLY L22 Lutron 2-Wire, Forward Phase (supports 1 - 10 fixtures) L32 Lutron 3-Wire, EcoSystem (supports 1 - 10 fixtures) 1 120 Volt 3 277 Volt INPUT VOLTAGE 1 120 Volt U 120 - 277 Volt U 120 - 277 Volt U 120 - 277 Volt 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC TYPE: SL Page: 3 of 5 pg. 3[PH] +1-210-227-7329 [FAX] +1-210-227-4967 ©2017 Lucifer Lighting Company As part of its policy of continuous research and product development, the company UHVHUYHVWKHULJKWWRFKDQJHRUZLWKGUDZVSHFLéFDWLRQVZLWKRXWSULRUQRWLFH luciferlighting.com [DATE OF REV: 111017] IMPACT ISL1 FIXTURE DIMENSIONS / DRAWINGS LED Regressed LED with wide low glare aperture, energy- HIéFLHQWSDWKDQGVWHSOLJKWLQJVXLWDEOHIRUGU\GDPSRU wet applications. 3.4W DC LED (dimming by power supply). EFFECTS DEVICES Provided with sealed polycarbonate linear diffusion lens; consult factory for availability of color gels, which may achieve custom color temperatures. LOCKING Discreetly hidden tamper-resistant set screws. Included with IP65 Wet location luminaire. GASKET Foam gasket provided. Required for IP65 wet location applications only. RETENTION 7RUVLRQVSULQJFOLSVVHFXUHé[WXUHLQWREDFNER[PRXQWLQJ plate, or appropriately sized cut-out. A B C D E B EC A D 4.00” ( 1 02 m m) S q. 3.40” (86mm) Sq. 0.63”( 1 6 m m) 3.40”( 8 6 m m) 5.00” (127mm) 3.90” (99mm) 2.00”(51mm) 2.00” ( 5 1 m m ) 2.82” ( 7 2 m m) 4.69” (119mm)5.25” (133mm) 3.00”( 7 6 m m) 2.00” ( 5 1 m m ) 2.63” (67mm) é[WXUHcenterline 2.00 ” ( 5 1 m m ) 2.82”( 7 2 m m) 4.69” (119mm) Collar depth varies onthe option selected Collar depth varies onthe option selectedSSL-UMP K F G H I J 3.50”(90 m m ) 6.50”(16 5 m m ) 0.6 9 ” ( 1 8 m m ) 2.40” (62mm) Sq. 1.0 0 ” ( 2 5 m m ) M L N 2.40” (62mm) Sq. 2.40”(62mm) Sq. SSL-MP-X.XX F G H I J SSL-RM 5HPRGHO0RXQWFROODUIRULQVWDOOLQJé[WXUHLQWRGU\ZDOO plasterboard. Requires Class 2 power supply. SSL-CC &DYLW\ &ROODU IRU LQVWDOOLQJ é[WXUH LQWR FDYLW\ RU ERUH Requires Class 2 power supply. SSL-SC3 Stud-mount Collar, adjusts with integral jackscrew from 1/2” to 3” for walls with varying substrate depths (rock, brick and stone). Features 1/2” knockouts for wiring. SSL-SC6 Stud-mount Collar, adjusts with integral jackscrew from 3” to 6” for walls with varying substrate depths (rock, brick and stone). Features 1/2” knockouts for wiring. MOUNTING REQUIRES REMOTE POWER SUPPLY MOUNTING REQUIRES REMOTE POWER SUPPLY K N L M WET AND DRY / DAMP LOCATION DRY / DAMP LOCATION ONLY 2.40” (62mm) Sq. 2.40” (62mm) Sq. 2.59" 66mm 1.58”(40mm)1.61”(41mm) 0.125”(3mm) 1.70” (43mm) 2.59”(66mm) 2.75” (70mm) 2.40”(62mm) Sq. SSL-UMP Universal Mounting Plate typically used with two-gang switch box or 4-square junction box for dry /damp locations. May be used with customer-furnished single or two gang weatherproof box and factory supplied gasket for wet and concrete pour locations. SSL-MP-(1.50 / 1.75 / 2.00 / 2.50 / 3.00) Mounting Plate includes gasket and features an extended collar for single-gang weatherproof box; specify preferred depth. Typically for wet and concrete pour locations. SSL-BB Back Box equipped with SSL-UMP mounting plate and gasket. Typically used in wet and concrete pour applications. Features 1/2” knockouts. SSL-BB-(1.50 / 1.75 / 2.00 / 2.50 / 3.00) Back Box equipped with SSL-MP-X.XX mounting plate and gasket; specify preferred depth. Typically used in wet and concrete pour locations. Features 1/2” knockouts. 66/60%êQLVK Surface Mounting Box for interior or exterior applications, SURYLGLQJêXVKPRXQWRIOXPLQDLUH5HFHLYHVVHFRQGDU\ ZLULQJWKURXJKEDFNRIER[3RZGHUFRDWéQLVKHVRQO\ 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC TYPE: SL Page: 4 of 5 pg. 4[PH] +1-210-227-7329 [FAX] +1-210-227-4967 ©2017 Lucifer Lighting Company As part of its policy of continuous research and product development, the company UHVHUYHVWKHULJKWWRFKDQJHRUZLWKGUDZVSHFLéFDWLRQVZLWKRXWSULRUQRWLFH luciferlighting.com [DATE OF REV: 111017] IMPACT ISL1 DIMENSIONS / DRAWINGS Q2 R S Q1 MOUNTING WITH INTEGRAL POWER SUPPLY 5.38” (137mm) 10.5” (227mm) 2.00”(51mm) 4.70” (119mm) 2.30”(58mm) 4.70” (119mm) 1.20”(33mm) 1.10”(28mm) 1.90”(49mm) 3.50” (90mm) B1 O O1 P P1 10.5” (267mm)4.00” (101mm) 3.00” (76mm) 2.45” (62mm) 10.5” (267mm)4.00” (101mm) 1.00”(25mm) 2.30”(59mm) Sq. REMOTE POWER SUPPLIES BOLLARD UBB-JCT-24V-60-XAT2-XXX Universal Junction Box, wet location and FRQFUHWH SRXU UDWHG &DQ EH VSHFLéHG ZLWK integral or remote power supply and features secondary output capacity, simplifying wiring practices and reducing budgets. See Page 2 for power supply options. Supplied with “-HGR” or “-BKT” mounting hardware, shown with Bracket (-BKT). Brackets, universal stainless steel mounting êDQJH PSA-24V-XX-XXXX Hardwire Class 2 power supply, consists of a steel compartment and lid painted black with integral conventional electronic power supply. Wired in either a homerun or parallel method. See page 2 for power supply options. Used for 60W electronic transformer (AT2). Used for 40W, 66W and 96W electronic transformers (EX2, ED3, LP1, L22 & L32). PSA-24V-60-1EL2 Plug-in Class 2 power supply, wires may be spliced to accomendate multiple luminaires in a parallel or home run method. P Q R S Q1 P1 Q2 O1 BOLLARD Free-standing mount. Available with integral or remote power supply. See BOLLARD spec sheet for complete details and ordering information. UBB-SL1-24V-60-XAT2-XXX Universal Back Box, wet location and concrete SRXU UDWHG &DQ EH VSHFLéHG ZLWK LQWHJUDO RU remote power supply and features secondary output capacity, simplifying wiring practices and reducing budgets. See Page 2 for power supply options. Supplied with mounting hardware, specify “-HGR” or “-BKT”. Shown with hanger bars (-HGR). Hanger bars, adjust from 14” to 24” for standard joist spacing. O 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: ISL1-2-**-80L-02B-2; SSL-UMP; PSA-24V-60-1-AT2 Lamping: 3.4W, 43 Lumens, 80+ CRI, 3000°K LED Voltage: 24V DC TYPE: SL Page: 5 of 5 pg. 5[PH] +1-210-227-7329 [FAX] +1-210-227-4967 ©2017 Lucifer Lighting Company As part of its policy of continuous research and product development, the company UHVHUYHVWKHULJKWWRFKDQJHRUZLWKGUDZVSHFLéFDWLRQVZLWKRXWSULRUQRWLFH luciferlighting.com [DATE OF REV: 111017] Power supply LP1 3URGXFW)DPLO\93DUW1R 93DUW1R 'ULYHUVSHU&RQWURO 120V 277V NovaT®NTF-10- NTF-10-277- 1 - 16 1-19 NTF-103P- NTF-103P-277- 1-8 1-14 Nova®NF-10- NF-10-277- 1-8 1-19 NF-103P- NF-103P-277- 1-8 1-14 Skylark®SF-10P- SF-12P-277- 1-8 1-14 SF-103P- SF-12P-277-3 1-8 1-14 Diva®DVF-103P- DVF-103P-277- 1-8 1-14 DVSCF-103P- DVSCF-103P-277- 1-8 1-14 Ariadni® AYF-103P- AYF-103P-277- 1-6 1-14 Maestro®MAF-6AM- MAF-6AM-277- 1-6 1-14 MSCF-6AM- MSCF-6AM-277- 1-6 1-14 Maestro Wireless® MRF2-F6AN-DV- 1-6 1-14 RadioRA® 2 RRD-F6AN-DV- 1-6 1-14 HomeWorks® QS HQRD-F6AN-DV 1-6 1-14 Interfaces PHPM-3F-120 - 1-16 - PHPM-3F-DV 1-16 1-38 BCI-0-10 1-16 1-38 GP Dimming Panels Various 1-16 1-38 PowPak™ with EcoSystem RMJ-ECO32-DV-B 32 per EcoSystem link URMJ-ECO32-DVB 32 per EcoSystem link FCJ-ECO 3 per EcoSystem link Energi Savr Node™ with EcoSystem QSN-1ECO-S, QSN-2ECO-S, QSN-2ECO-PS120, UQSN-1ECO-S, UQSN-2ECO-S 64 per EcoSystem link GRAFIK Eye® QS with EcoSystem QSGRJ-_E QSGR-_E - 64 per EcoSystem link HomeWorks® QS with EcoSystem LQSE-2ECO-D, QSGRJ-_E, QSGR-_E 64 per EcoSystem link Quantum® QP2-_P_C 64 per EcoSystem link Power supply L32 3URGXFW)DPLO\93DUW1R 93DUW1R 'ULYHUVSHU&RQWURO 120V 277V NovaT®NTF-10- NTF-10-277- 1 -41 1-44 NTF-103P- NTF-103P-277- 1-20 1-33 Nova®NF-10- NF-10-277- 1-41 1-44 NF-103P- NF-103P-277- 1-20 1-33 Skylark®SF-10P- SF-12P-277- 1-20 1-33 SF-103P- SF-12P-277-3 1-20 1-33 Diva®DVF-103P- DVF-103P-277- 1-20 1-33 DVSCF-103P- DVSCF-103P-277- 1-20 1-33 Ariadni® AYF-103P- AYF-103P-277- 1-20 1-44 Maestro®MAF-6AM- MAF-6AM-277- 1-15 1-20 MSCF-6AM- MSCF-6AM-277- 1-15 1-20 Maestro Wireless® MRF2-F6AN-DV- 1-15 1-33 RadioRA® 2 RRD-F6AN-DV- 1-15 1-33 HomeWorks® QS HQRD-F6AN-DV 1-15 1-33 Interfaces PHPM-3F-120 - 1-41 - PHPM-3F-DV 1-41 1-88 GP Dimming Panels Various 1-41 1-88 PowPak™ with EcoSystem RMJ-ECO32-DV-B 32 per EcoSystem link FCJ-ECO 3 per EcoSystem link Energi Savr Node™ with EcoSystem QSN-1ECO-S, QSN-2ECO-S 64 per EcoSystem link GRAFIK Eye® QS with EcoSystem QSGRJ-_E QSGR-_E - 64 per EcoSystem link Quantum® QP2-_P_C 64 per EcoSystem link IMPACT ISL1 LUTRON DIMMING COMPATIBILITY Power supply/3URGXFW)DPLO\ 3DUW1R 'ULYHUV3HU&RQWURO 9RQO\ Maestro WirelessR 600 W dimmer MRF2-6ND-120- 1-8 Maestro WirelessR 1000 W dimmer MRF2-10ND-120- 1-13 Caséta® Wireless Pro 1000 W dimmer PD-10NXD- 1-13 GRAFIK TTM CL® dimmer GT-250M-, GTJ-250M- 1-10 HomeWorks® QS adaptive dimmer HQRD-6NA- 1-8 HomeWorks® QS 600 W dimmer HQRD-6ND- 1-8 HomeWorks® QS 1000 W dimmer HQRD-10ND- 1-13 RadioRA® 2 adaptive dimmer RRD-6NA- 1-8 RadioRA® 2 1000 W dimmer RRD-10ND 1-13 myRoomTM DIN power module MQSE-4A1-D 1-6 (per output), 1A max driver input current HomeWorks® QS DIN power module LQSE-4A1-D 1-6 (per output), 1A max driver input current HomeWorks® QS wallbox power module HQRJ-WPM-6D-120 2-10 (per output), 26 total per module HomeWorks® wallbox power module HWI-WPM-6D-120 2-10 (per output), 26 total per module GRAFIK Eye® QS control unit QSGR-, QSGRJ- 2-10 (per output), 26 total per module GRAFIK Eye® 3000 control unit GRX-3100-, GRX-3500- 2-10 (per output), 26 total per module RPM-4U module (LCP, HomeWorks® QS, GRAFIK SystemsTM, Quantum®) HW-RPM-4U-120, LP-RPM-4U-120 2-26 (per output), 26 total per module RPM-4A module (LCP, HomeWorks® QS, GRAFIK SystemsTM, Quantum®) HW-RPM-4A-120, LP-RPM-4A-120 1-13 (per output), 26 total per module GP dimming panels Various 1-26 Ariadni CL 250W dimmer AYCL-253P- 1-8 Diva CL 250W dimmer DVCL-253P- DCSCCL-253P-1-8 Nova T CL 250W dimmer NTCL-250- 1-10 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: Urbandale - OL13703ANBZ-L1 Lamping: 26W LED; 1915Lumens; 90CRI Location: Entry TYPE: XD2.1 Page: 1 of 2 OL13703ANBZ-L1: 1 - Light Outdoor LED Wall Lantern Collection: Urbandale UPC #:014817582369 Finish: Antique Bronze (ANBZ) Dimensions: Width:10'' Height:23'' Weight:17.38 lbs. Extends:8'' Wire:8'' Mounting Proc.:Set Screw(s) Connection:Mounted To Box Bulb Type:Modules Bulb Base:Integrated Volts:120 Watts:26 Watts Consumed:26 Watts Rated:26 Hours Rated:50000 Lumens:1915 Bulb Temp:2700 °K CRI:90 Bulbs: 1 - LED Integrated Array 26w 120v - included Features: Advanced LED technology that warms in color when dimmed (2700K - 2200K). This advanced LED technology is carefully designed and selected to consist of the highest quality LED chipsets for superior performance and reliability. Meets Title 24 energy efficiency standards Material List: 1 Body - StoneStrong - Antique Bronze Safety Listing: Safety Listed for Wet Locations Instruction Sheets: Trilingual (English, Spanish, and French) (OL13700-OL13701-OL13702-OL13703-LED) Shade / Glass / Diffuser Details: Part Material Finish Quantity Item Number Length Width Height Diameter Fitter Diameter Shade Top Length Shade Top Width Shade Top Diameter Glass Glass Undefined 1 Backplate / Canopy Details: Type Height / Length Width Depth Diameter Outlet Box Up Outlet Box Down Back Plate 18 3/4 9 1/2 1/2 11 1/2 Shipping Information: Package Type Product #Quantity UPC Length Width Height Cube Weight Frt. Class UPS Ship Feiss reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Feiss . In compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any manner without the express written consent of, or contrary to the best interests of Feiss � A Generation Brands Company. 5/23/2018 Lens must be frosted. Section 26.575.150, Outdoor Lighting.(F), Residential Lighting Standards ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: Urbandale - OL13703ANBZ-L1 Lamping: 26W LED; 1915Lumens; 90CRI Location: Entry TYPE: XD2.1 Page: 2 of 2 Individual OL13703ANBZ-L1 1 014817582369 27.75 15.25 15 3.674 21.1 150 Yes NJ Pallet 16 48 40 65 72.222 337.6 No NV Pallet 16 48 40 65 72.222 337.6 No Feiss reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Feiss . In compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any manner without the express written consent of, or contrary to the best interests of Feiss � A Generation Brands Company. 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: Urbandale - OL13701ANBZ-L1 Lamping: 14W LED; 1000Lumens; 90CRI Location: Garage and Side Entry TYPE: XD2.2 Page: 1 of 2 OL13701ANBZ-L1: 1 - Light Outdoor LED Wall Lantern Collection: Urbandale UPC #:014817582345 Finish: Antique Bronze (ANBZ) Dimensions: Width:8'' Height:13'' Weight:6.07 lbs. Extends:6'' Wire:8'' Mounting Proc.:Set Screw(s) Connection:Mounted To Box Bulb Type:Modules Bulb Base:Integrated Volts:120 Watts:14 Watts Consumed:14 Watts Rated:14 Hours Rated:50000 Lumens:1000 Bulb Temp:2700 °K CRI:90 Bulbs: 1 - LED Integrated Array 14w 120v - included Features: Advanced LED technology that warms in color when dimmed (2700K - 2200K). This advanced LED technology is carefully designed and selected to consist of the highest quality LED chipsets for superior performance and reliability. Meets Title 24 energy efficiency standards Material List: 1 Body - StoneStrong - Antique Bronze Safety Listing: Safety Listed for Wet Locations Instruction Sheets: Trilingual (English, Spanish, and French) (OL13700-OL13701-OL13702-OL13703-LED) Shade / Glass / Diffuser Details: Part Material Finish Quantity Item Number Length Width Height Diameter Fitter Diameter Shade Top Length Shade Top Width Shade Top Diameter Glass Glass Undefined 1 Backplate / Canopy Details: Type Height / Length Width Depth Diameter Outlet Box Up Outlet Box Down Back Plate 8 1/4 7 1/2 1/2 6 1/2 Shipping Information: Package Type Product #Quantity UPC Length Width Height Cube Weight Frt. Class UPS Ship Feiss reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Feiss . In compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any manner without the express written consent of, or contrary to the best interests of Feiss � A Generation Brands Company. 5/23/2018 Lens must be frosted. Section 26.575.150, Outdoor Lighting.(F), Residential Lighting Standards ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: Urbandale - OL13701ANBZ-L1 Lamping: 14W LED; 1000Lumens; 90CRI Location: Garage and Side Entry TYPE: XD2.2 Page: 2 of 2 Individual OL13701ANBZ-L1 1 014817582345 16.25 11 11.5 1.19 8 125 Yes NJ Pallet 60 48 40 72 80 480 No NV Pallet 60 48 40 72 80 480 No Feiss reserves the right to revise the design of components of any product due to parts availability or change in safety listing standards without assuming any obligation or liability to modify any products previously manufactured and without notice. This literature depicts a product design that is the sole and exclusive property of Feiss . In compliance with U.S copyright and patent requirements, notification is hereby presented in this form that this literature, or the product it depicts, is not to be copied, altered or used in any manner without the express written consent of, or contrary to the best interests of Feiss � A Generation Brands Company. 5/23/2018 ROBERT SINGER & ASSOCIATES INC. PROJECT: Cayton Residence ISSUE DATE: 05/18/2018 Catalog #: 700WSPITS*-LED830 Lamping: 22W; 495Lumen; 80+CRI; 3000K Location: Exterior Lower Garage TYPE: XD2.3 Page: 1 of 1 DESCRIPTION An architectural profile reminiscent of beautifully classic roof lines delivers significant light output in the Pitch modern LED wall sconce by Tech Lighting which is suitable for both indoor and outdoor applications. The Pitch’s diecast metal body, available in three size configurations (single, double, or triple), houses powerful LED light sources that create visual appeal as light cascades from one angular tier to the next. For added design options, the Pitch can be mounted either as a down light or as an up light. The durable, marine grade powder coat finish is available in either Charcoal, Bronze, Black, or Silver. IP65 wet listed. L70, 70,000 hours. 5year warranty. black bronze charcoal silver ORDERING INFORMATION 700WSPIT SHAPE OR SIZE FINISH LAMP S SINGLE B BLACK Z BRONZE H CHARCOAL I SILVER LED827 LED827277 LED830 LED 80 CRI 3000K 120V LED830277 LED 80 CRI 3000K 277V 7400 Linder Avenue Skokie, Illinois 60077 Tech Lighting, L.L.C. T 847.410.4400 F 847.410.4500 700WSPIT ____ ____ ____ FIXTURE TYPE:________________________________________________ JOB NAME:________________________________________________ NOTES:________________________________________________ ________________________________________________ ________________________________________________ ©2018 Tech Lighting, L.L.C. All Rights Reserved. The "Tech Lighting" graphic is a registered trademark of Tech Lighting, L.L.C. Tech Lighting reserves the right to change specifications for product improvements without notification. Pitch Single Outdoor Wall Powered by TCPDF (www.tcpdf.org) 5/23/2018