Loading...
HomeMy WebLinkAboutFile Documents.124 W Hallam St.0025.2017 (23).ARBKHealthSafe Inspections Inc 1052 Vine St Aspen CO 81611 970-920-2100 Jim Baker CDPHE Asbestos Building Inspector Certification #13437 Mark Bridges CDPHE Asbestos Building Inspector Certification #22322 ASBESTOS REPORT DATE: September 13, 2015 CLIENT: 308 Aspen E, LLC 625 E Main St, Suite 102B-233 Aspen CO 81611 Attn: Bill Guth PROJECT PROPERTY ADDRESS: 308 North First Street, Aspen, Colorado 81611 COLORADO ASBESTOS REGULATIONS SUMMARY: Colorado State Regulation 8 requires a State certified Asbestos Building Inspector to inspect and sample for suspect asbestos containing materials (ACM) or suspect asbestos containing building materials (ACBM) prior to the disturbance, removal or demolition. In residential buildings of four or fewer units if more than 32 square feet of any surface coverage (e.g., gypsum wallboard or drywall and associated applied surfacing materials/textures, acoustic sprays, joint compounds, plaster, etc.), 50 feet of asbestos covered or asbestos insulated pipe or any material which would fill a 55 gallon drum—if these materials are going to be disturbed or removed—an asbestos inspection is required by a state certified asbestos building inspector. For buildings with more than four residential units (considered public), including commercial, public (including public access areas to a residential building), civic or industrial buildings, if more than 160 square feet of surfacing materials, 260 linear feet or more than 35 cubic feet of suspect ACM/ACBM is going to be disturbed, an asbestos inspection is required under NESHAP. County or City regulations may be more stringent. The regulations require an absolute minimum of 3 samples (EPA suggests 9) per homogenous suspect surfacing and TSI materials and an absolute minimum of 1 sample of homogenous miscellaneous materials or any number of “samples sufficient to 09/14/2017 determine whether a material is ACM” (Reg8.IV.D.3). More samples are required based on surface area or volume. In order for the contractor to proceed with restoration, renovation or demolition the suspect materials have to be sampled and analyzed by a NVLAP accredited laboratory by polarized light microscopy (PLM) methods. OSHA compliance is required for all employers/employees no matter the quantity of asbestos present. CLIENT BACKGROUND: The client, Bill Guth, hired HealthSafe Inspections, Inc. to perform required asbestos inspection, bulk sampling and reporting in preparation for renovation construction activity, including possible demolition of this property. VISUAL INSPECTION, ASSESSMENT & LABORATORY FINDINGS: An inspection was conducted by Mark Bridges, of HealthSafe Inspections, Inc. on Tuesday, September 2, 2015. This property is comprised of three structures - original victorian main house with add-on, renovated/remodeled spaces, detached garage, and guest cottage. Suspect ACM/ACBM were identified and sampled; those materials were the following: 1. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [UBRCLT-OP-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were on northwest facing upstairs bedroom closet and walls and ceiling with an “orange peel” surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 3,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results: CHRYSOTILE ASBESTOS 3% present with trace (TR) <1% CHRYSOTILE ASBESTOS within compound matrix. This material is classified as ACM and will required asbestos abatement for removal and disposal. 2. A homogenous spray-applied orange peel surfacing material/texture [UBRCLT-OP- C/W-T-1, 2, 3, 4, 5]. This surfacing material/texture was on closet and bedroom walls and ceiling. The estimated impact area was more than 32 sf, but less than 3,000 sf, requiring a minimum of at least five surfacing/texture material samples. The PLM analytical estimated results T-1, 2, 4, : CHRYSOTILE ASBESTOS 3%; Samples T-3, 5: The PLM analytical estimated results: NONE DETECTED. This material is classified as ACM and will required asbestos abatement for removal and disposal. 3. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [STRCL-OP-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were on under stairs storage closet walls and ceiling, staircase walls and ceiling, and main floor entry bathroom, and bedroom entrance hall walls with an “orange peel” surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results: CHRYSOTILE ASBESTOS 3% with trace (TR) <1% CHRYSOTILE ASBESTOS within compound matrix. This material is classified as ACM and will required asbestos abatement for removal and disposal. 4. A homogenous spray-applied orange peel surfacing material/texture [STRCL-OP-C/W- T-1, 2, 3, 4, 5; LIV-OP-C/W-T-6; DIN-OP-C/W-T-7]. This surfacing material/texture was on under stairs storage closet walls and ceiling, staircase walls and ceiling, and main floor entry bathroom, bedroom entrance hall walls, 09/14/2017 living room, and dining room with an “orange peel” surfacing material/texture. The estimated impact area was more than 32 sf, but less than 3,000 sf, requiring a minimum of at least five surfacing/texture material samples. The PLM analytical estimated results: Samples T-1, 4, 6, 7: CHRYSOTILE ASBESTOS 2&3%; Sample T-5, trace (TR) <1% CHRYSOTILE ASBESTOS; samples T2, 3: NONE DETECTED. This material is classified as ACM and will required asbestos abatement for removal and disposal. 5. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [MBRCL-FLT-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were on main floor master bedroom and closet walls with a flat painted (FLT) surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results: CHRYSOTILE ASBESTOS 2% present. This material is classified as ACM and will required asbestos abatement for removal and disposal. 6. A homogenous spray-applied FLT surfacing material/texture [MBRCL-FLT-C/W-T-1, 2, 3]. This surfacing material/texture was on main floor master bedroom and closet walls with a flat painted (FLT) surfacing material/texture. The estimated impact area was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: Samples T-1, 2: Trace (TR) <1% CHRYSOTILE ASBESTOS; Sample T-3: NONE DETECTED. This material is classified as ACM, unless “Point Count” analysis is done for these surfacing material samples with trace and the joint samples above in paragraph 5 are point counted and the composite results are less than 1% Chrysotile asbestos. As is, HealthSafe concludes that this is ACM and will required asbestos abatement for removal and disposal. 7. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [KTCNTH-FLT-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were on kitchen, kitchen bathroom, utility, and pantry walls with an FLT surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results J-1 (bathroom): CHRYSOTILE ASBESTOS 3% present; J-2 (utility room) trace (TR) <1% CHRYSOTILE ASBESTOS. This material is classified as ACM and will required asbestos abatement for removal and disposal. 8. A homogenous spray-applied FLT surfacing material/texture [KTCNTH-FLT-C/W-T-1, 2, 3]. This surfacing material/texture was on kitchen, kitchen bathroom, utility, and pantry walls with a flat painted (FLT) surfacing material/texture. The estimated impact area was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: Samples T-1 NONE DETECTED; Sample T-2, 3 (pantry &utility, trace (TR) <1% CHRYSOTILE ASBESTOS. This material is classified as ACM, unless “Point Count” analysis is done for these surfacing material samples with trace and the joint samples above in paragraph 7 are point counted and the composite results are less than 1% Chrysotile asbestos. As is, HealthSafe concludes that this is ACM and will required asbestos abatement for removal and disposal. 9. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [MUDRM-OP-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were 09/14/2017 on mudroom walls and ceiling with an orange peel surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results: J-1: CHRYSOTILE ASBESTOS 2%; J- 2: (TR) <1% CHRYSOTILE ASBESTOS within compound matrix. This material is classified as ACM and will required asbestos abatement for removal and disposal. 10. A homogenous spray-applied orange peel surfacing material/texture [MDRM-OP-C/W- T-1, 2, 3]. This surfacing material/texture was on mudroom walls and ceiling with an orange peel surfacing material/texture. The estimated impact area was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: Samples T-1, 3: CHRYSOTILE ASBESTOS 2%; Sample T-2: trace (TR) <1% CHRYSOTILE ASBESTOS. This material is classified as ACM and will required asbestos abatement for removal and disposal. 11. A homogenous taped and joint compounded drywall system (classified as a miscellaneous material as a complete integral system) [CRTK-OP-C/W-J-1, 2]. These composite layered taped and joint compounded drywall materials were on caretaker walls and ceiling with an orange peel surfacing material/texture. The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core samples of all drywall layers. The PLM analytical estimated results: CHRYSOTILE ASBESTOS 2%, 3%. This material is classified as ACM and will required asbestos abatement for removal and disposal. 12. A homogenous spray-applied orange peel surfacing material/texture [CRTK-OP-C/W-T- 1, 2, 3]. This surfacing material/texture was on caretaker room walls and ceiling with an orange peel surfacing material/texture. The estimated impact area was more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three surfacing/texture material samples. The PLM analytical estimated results: trace (TR) <1% CHRYSOTILE ASBESTOS. This material is classified as ACM, unless “Point Count” analysis is done for these surfacing material samples with trace and the joint samples above in paragraph 11 are point counted and the composite results are less than 1% Chrysotile asbestos. As is, HealthSafe concludes that this is ACM and will required asbestos abatement for removal and disposal. 13. Miscellaneous suspect ACM roofing paper [RFP-T]. The PLM analytical estimated results: NONE DETECTED. A total of 36 suspect homogenous ACM/ACBM bulk samples were collected and 36 samples were analyzed. The bulk samples were analyzed by PLM by a NVLAP accredited laboratory in accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers. There was NO asbestos in 6 samples. CHRYSOTILE >2-3% present in 23 samples; trace Chrysotile <1% in 15 samples analyzed (total trace amounts also present within some CHRYSOTILE >2- 3% samples) See supporting Reservoirs Environmental, Inc., data: report # RES 330918-1 HEALTHSAFE CONCLUSIONS: 09/14/2017 There is CHRYSOTILE >1% present in 23 bulk samples of the suspect building materials slated to be impacted by renovation/demolition. This material is classified as ACM and will required asbestos abatement for removal and disposal. TRACE Chrysotile <1% is present in 15 samples analyzed. State regulation requires all TRACE samples be “Point Counted”, unless assumed ACM. In order for the TRACE samples to be confirmed as less than 1.0%, they must be “Point Counted”. In the case of this particular inspection and set of samples, HealthSafe has concluded that ALL drywall systems on the property are classified as ACM. There are 3 different homogenous drywall systems with Chrysotile asbestos Sincerely Submitted, Mark Bridges Reviewed by Jim Baker 09/14/2017 Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc Subcontract Number:NA Laboratory Report:RES 330918-1 Project # / P.O. # Bill Guth Project Description:308 N. 1st St Aspen CO 81611 RES 330918-1 Sincerely, is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer.Reservoirs Environmental,Inc.will not discuss any part of this study with personnel other than those of the client.The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S.Government.This report shall not be reproduced except in full,without written approval from Reservoirs Environmental,Inc.Samples will be disposed of after sixty days unless longer storage is requested.If you have any questions about this report, please feel free to call 303-964-1986. Jeanne Spencer President September 9, 2015 Dear Customer, Reservoirs Environmental,Inc.is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP),Lab Code 101896-0 for Transmission Electron Microscopy (TEM)and Polarized Light Microscopy (PLM)analysis and the American Industrial Hygiene Association (AIHA),Lab ID 101533 -Accreditation Certificate #480 for Phase Contrast Microscopy (PCM)analysis.This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental,Inc.has analyzed the following samples for asbestos content as per your request.The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. HealthSafe Inspections, Inc. 1052 Vine St. Aspen CO 81611 P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 1 1-866-RESI-ENV www.reilab.com 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000UBRCLT-OP-C/W-J-1 EM 1483649 White plasterA 1 ND 1000Beige paint w/ white compoundB 3 TR Chrysotile 970Beige joint compoundC 4 3 Chrysotile 199White tapeD 12 ND 6535White/brown drywallE 80 ND 970UBRCLT-OP-C/W-J-2 EM 1483650 Tan compoundA TR 3 Chrysotile 1000Pink/beige paintB 3 ND 199White tapeC 12 ND 1000White joint compoundD 20 ND 1000White texture w/ beige paintE 20 ND 6040White/brown drywallF 45 ND 970UBRCLT-OP-C/W-T-1 EM 1483651 Tan compoundA 15 3 Chrysotile 595Brown/white drywallB 35 ND 1000White paintC 50 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 1 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 595UBRCLT-OP-C/W-T-2 EM 1483652 Brown/white drywallA 5 ND 970Tan compoundB 25 3 Chrysotile 1000White paintC 70 ND 2080UBRCLT-OP-C/W-T-3 EM 1483653 Brown/white drywallA 35 ND 1000White compound w/ white paintB 65 ND 970UBR-OP-C/W-T-4 EM 1483654 Tan compoundA 4 3 Chrysotile 595Brown/white drywallB 16 ND 1000Tan/multi-colored paintC 80 ND 595UBR-OP-C/W-T-5 (Sample Labeled UHLL-OP-C/W-T-5) EM 1483655 Brown/white drywallA 5 ND 1000White compound w/ beige/white paintB 95 ND 2080STRCL-OP-C/W-J-1 EM 1483656 White tape w/ white paintA 10 ND 970Tan compoundB 25 3 Chrysotile 8020White/brown drywallC 65 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 2 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 970STRCL-OP-C/W-J-2 EM 1483657 Beige joint compoundA 1 3 Chrysotile 1000White paint w/ beige compoundB 2 TR Chrysotile 1000White plasterC 5 ND 199White tapeD 7 ND 991Beige granular plasterE 15 ND 1000White caulkF 20 ND 7525White/brown drywallG 50 ND 970STRCL-OP-C/W-T-1 EM 1483658 Beige compoundA 20 3 Chrysotile 298Brown drywall paperB 25 ND 1000White paintC 55 ND 1000ENTBTH-OP-C/W-T-2 EM 1483659 White compound w/ white/gray paintA 100 ND 1090ENT-OP-C/W-T-3 EM 1483660 Brown/white drywallA 1 ND 1000White compound w/ white/gray paintB 99 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 3 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 298LBR-OP-C/W-T-4 EM 1483661 Brown drywall paperA 3 ND 980White compoundB 37 2 Chrysotile 1000Tan/white paintC 60 ND 1000LBR-OP-C/W-T-5 EM 1483662 Tan/white paint w/ a trace of tan compoundA 40 TR Chrysotile 1090Brown/white drywallB 60 ND 980MBRCL-FLT-C/W-J-1 EM 1483663 White joint compoundA 2 2 Chrysotile 980White compoundB 3 2 Chrysotile 1000White paintC 5 ND 199White tapeD 10 ND 7030White/brown drywallE 80 ND 1000MBRCL-FLT-C/W-T-1 EM 1483664 White compoundA 3 TR Chrysotile 298Brown drywall paperB 27 ND 1000White paintC 70 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 4 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000MBRCL-FLT-C/W-T-2 EM 1483665 White compoundA 1 TR Chrysotile 298Brown drywall paperB 19 ND 1000White paintC 80 ND 5545MBRCL-FLT-C/W-T-3 EM 1483666 White paint w/ brown drywall paperA 100 ND 970KTCNTH-FLT-C/W-J-1 EM 1483667 Tan compoundA TR 3 Chrysotile 2080White tape w/ white paintB 10 ND 3070White fibrous material w/ white/multi-colored paintC 20 ND 7525White/brown drywallD 70 ND 1000KTCNTH-FLT-C/W-J-2 EM 1483668 White joint compoundA 2 TR Chrysotile 1000White/yellow paint w/ white compoundB 3 TR Chrysotile 199White tapeC 15 ND 7030White/brown drywallD 80 ND 6040KTCNTH-FLT-C/W-T-1 EM 1483669 White/multi-colored paint w/ white fibrous materialA 100 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 5 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000KTCNTH-FLT-C/W-T-2 EM 1483670 White compoundA 4 TR Chrysotile 298Brown drywall paperB 6 ND 1000White paintC 90 ND 298KTCNTH-FLT-C/W-T-3 EM 1483671 Brown drywall paperA 30 ND 1000White paint w/ a trace of white compoundB 70 TR Chrysotile 980MUDRM-OP-C/W-J-1 EM 1483672 White joint compoundA 3 2 Chrysotile 199White tapeB 7 ND 1000White texture w/ yellow/white paintC 10 ND 980White compoundD 15 2 Chrysotile 6535White/brown drywallE 65 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 6 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000MDRM-OP-C/W-J-2 EM 1483673 Yellow paintA 3 ND 1000White joint compoundB 3 TR Chrysotile 1000White compoundC 4 TR Chrysotile 199White tapeD 10 ND 8020White/brown drywallE 80 ND 980MDRM-OP-C/W-T-1 EM 1483674 White compoundA 20 2 Chrysotile 1000Yellow/white paintB 80 ND 298MDRM-OP-C/W-T-2 EM 1483675 Brown drywall paperA 40 ND 1000Yellow/white paint w/ a trace of white compoundB 60 TR Chrysotile 980MDRM-OP-C/W-T-3 EM 1483676 White compoundA 10 2 Chrysotile 1000Yellow/white paintB 90 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 7 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 970CRTK-OP-C/W-J-1 EM 1483677 White joint compoundA 4 3 Chrysotile 980White compoundB 5 2 Chrysotile 1000Beige paintC 10 ND 199White tapeD 16 ND 6535White/brown drywallE 65 ND 970CRTK-OP-C/W-J-2 EM 1483678 White joint compoundA 3 3 Chrysotile 970White compoundB 4 3 Chrysotile 1000Beige paintC 4 ND 199White tapeD 9 ND 7525White/brown drywallE 80 ND 1000CRTK-OP-C/W-T-1 EM 1483679 White compoundA 4 TR Chrysotile 2080Brown/white drywallB 16 ND 1000Off white/white paintC 80 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 8 of 9 09/14/2017 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 330918-1 HealthSafe Inspections, Inc. Bill Guth 308 N. 1st St Aspen CO 81611 September 02, 2015 3-5 Day September 09, 2015 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective January 1, 2015 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method:EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000CRTK-OP-C/W-T-2 EM 1483680 White compoundA 3 TR Chrysotile 298Brown drywall paperB 7 ND 1000Off white/white paintC 90 ND 1000CRTK-OP-C/W-T-3 EM 1483681 White compoundA 3 TR Chrysotile 1000Off white/white paintB 97 ND 970LIV-OP-C/W-T-6 EM 1483682 Beige joint compoundA 5 3 Chrysotile 970Beige compoundB 10 3 Chrysotile 199White tapeC 25 ND 1000Beige/white paintD 30 ND 298Brown drywall paperE 30 ND 970DIN-OP-C/W-T-7 EM 1483683 Tan compoundA 1 3 Chrysotile 298Brown drywall paperB 6 ND 1000Tan/white paintC 93 ND 3565RFPR-T EM 1483684 Black feltA 100 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. Analyst / Data QAAnalystAnalystAnalystAnalyst P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 9 of 9 09/14/2017 09/14/2017 09/14/2017 09/14/2017 09/14/2017 09/14/2017