ASBESTOS REPORT
DATE:
September 13, 2015
CLIENT:
308 Aspen E, LLC
625 E Main St, Suite 102B-233
Aspen CO 81611
Attn: Bill Guth
PROJECT PROPERTY ADDRESS:
308 North First Street, Aspen, Colorado 81611
COLORADO ASBESTOS REGULATIONS SUMMARY:
Colorado State Regulation 8 requires a State certified Asbestos Building Inspector to inspect and
sample for suspect asbestos containing materials (ACM) or suspect asbestos containing building
materials (ACBM) prior to the disturbance, removal or demolition. In residential buildings of
four or fewer units if more than 32 square feet of any surface coverage (e.g., gypsum wallboard
or drywall and associated applied surfacing materials/textures, acoustic sprays, joint compounds,
plaster, etc.), 50 feet of asbestos covered or asbestos insulated pipe or any material which would
fill a 55 gallon drum—if these materials are going to be disturbed or removed—an asbestos
inspection is required by a state certified asbestos building inspector. For buildings with more
than four residential units (considered public), including commercial, public (including public
access areas to a residential building), civic or industrial buildings, if more than 160 square feet
of surfacing materials, 260 linear feet or more than 35 cubic feet of suspect ACM/ACBM is
going to be disturbed, an asbestos inspection is required under NESHAP. County or City
regulations may be more stringent. The regulations require an absolute minimum of 3 samples
(EPA suggests 9) per homogenous suspect surfacing and TSI materials and an absolute minimum
of 1 sample of homogenous miscellaneous materials or any number of “samples sufficient to 09/14/2017
determine whether a material is ACM” (Reg8.IV.D.3). More samples are required based on
surface area or volume. In order for the contractor to proceed with restoration, renovation or
demolition the suspect materials have to be sampled and analyzed by a NVLAP accredited
laboratory by polarized light microscopy (PLM) methods. OSHA compliance is required for all
employers/employees no matter the quantity of asbestos present.
CLIENT BACKGROUND:
The client, Bill Guth, hired HealthSafe Inspections, Inc. to perform required asbestos inspection,
bulk sampling and reporting in preparation for renovation construction activity, including
possible demolition of this property.
VISUAL INSPECTION, ASSESSMENT & LABORATORY FINDINGS:
An inspection was conducted by Mark Bridges, of HealthSafe Inspections, Inc. on Tuesday,
September 2, 2015. This property is comprised of three structures - original victorian main
house with add-on, renovated/remodeled spaces, detached garage, and guest cottage. Suspect
ACM/ACBM were identified and sampled; those materials were the following:
1. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [UBRCLT-OP-C/W-J-1,
2]. These composite layered taped and joint compounded drywall materials were
on northwest facing upstairs bedroom closet and walls and ceiling with an
“orange peel” surfacing material/texture. The estimated impact area of remodel
was more than 32 sf, but less than 3,000 sf, requiring a minimum of at least two
composite core samples of all drywall layers. The PLM analytical estimated
results: CHRYSOTILE ASBESTOS 3% present with trace (TR) <1%
CHRYSOTILE ASBESTOS within compound matrix. This material is
classified as ACM and will required asbestos abatement for removal and disposal.
2. A homogenous spray-applied orange peel surfacing material/texture [UBRCLT-OP-
C/W-T-1, 2, 3, 4, 5]. This surfacing material/texture was on closet and bedroom
walls and ceiling. The estimated impact area was more than 32 sf, but less than
3,000 sf, requiring a minimum of at least five surfacing/texture material samples.
The PLM analytical estimated results T-1, 2, 4, : CHRYSOTILE ASBESTOS
3%; Samples T-3, 5: The PLM analytical estimated results: NONE DETECTED.
This material is classified as ACM and will required asbestos abatement for
removal and disposal.
3. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [STRCL-OP-C/W-J-1, 2].
These composite layered taped and joint compounded drywall materials were on
under stairs storage closet walls and ceiling, staircase walls and ceiling, and main
floor entry bathroom, and bedroom entrance hall walls with an “orange peel”
surfacing material/texture. The estimated impact area of remodel was more than
32 sf, but less than 1,000 sf, requiring a minimum of at least two composite core
samples of all drywall layers. The PLM analytical estimated results:
CHRYSOTILE ASBESTOS 3% with trace (TR) <1% CHRYSOTILE
ASBESTOS within compound matrix. This material is classified as ACM and
will required asbestos abatement for removal and disposal.
4. A homogenous spray-applied orange peel surfacing material/texture [STRCL-OP-C/W-
T-1, 2, 3, 4, 5; LIV-OP-C/W-T-6; DIN-OP-C/W-T-7]. This surfacing
material/texture was on under stairs storage closet walls and ceiling, staircase
walls and ceiling, and main floor entry bathroom, bedroom entrance hall walls, 09/14/2017
living room, and dining room with an “orange peel” surfacing material/texture.
The estimated impact area was more than 32 sf, but less than 3,000 sf, requiring a
minimum of at least five surfacing/texture material samples. The PLM analytical
estimated results: Samples T-1, 4, 6, 7: CHRYSOTILE ASBESTOS 2&3%;
Sample T-5, trace (TR) <1% CHRYSOTILE ASBESTOS; samples T2, 3:
NONE DETECTED. This material is classified as ACM and will required
asbestos abatement for removal and disposal.
5. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [MBRCL-FLT-C/W-J-1,
2]. These composite layered taped and joint compounded drywall materials were
on main floor master bedroom and closet walls with a flat painted (FLT) surfacing
material/texture. The estimated impact area of remodel was more than 32 sf, but
less than 1,000 sf, requiring a minimum of at least two composite core samples of
all drywall layers. The PLM analytical estimated results: CHRYSOTILE
ASBESTOS 2% present. This material is classified as ACM and will required
asbestos abatement for removal and disposal.
6. A homogenous spray-applied FLT surfacing material/texture [MBRCL-FLT-C/W-T-1,
2, 3]. This surfacing material/texture was on main floor master bedroom and
closet walls with a flat painted (FLT) surfacing material/texture. The estimated
impact area was more than 32 sf, but less than 1,000 sf, requiring a minimum of at
least three surfacing/texture material samples. The PLM analytical estimated
results: Samples T-1, 2: Trace (TR) <1% CHRYSOTILE ASBESTOS; Sample
T-3: NONE DETECTED. This material is classified as ACM, unless “Point
Count” analysis is done for these surfacing material samples with trace and the
joint samples above in paragraph 5 are point counted and the composite results
are less than 1% Chrysotile asbestos. As is, HealthSafe concludes that this is
ACM and will required asbestos abatement for removal and disposal.
7. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [KTCNTH-FLT-C/W-J-1,
2]. These composite layered taped and joint compounded drywall materials were
on kitchen, kitchen bathroom, utility, and pantry walls with an FLT surfacing
material/texture. The estimated impact area of remodel was more than 32 sf, but
less than 1,000 sf, requiring a minimum of at least two composite core samples of
all drywall layers. The PLM analytical estimated results J-1 (bathroom):
CHRYSOTILE ASBESTOS 3% present; J-2 (utility room) trace (TR) <1%
CHRYSOTILE ASBESTOS. This material is classified as ACM and will
required asbestos abatement for removal and disposal.
8. A homogenous spray-applied FLT surfacing material/texture [KTCNTH-FLT-C/W-T-1,
2, 3]. This surfacing material/texture was on kitchen, kitchen bathroom, utility,
and pantry walls with a flat painted (FLT) surfacing material/texture. The
estimated impact area was more than 32 sf, but less than 1,000 sf, requiring a
minimum of at least three surfacing/texture material samples. The PLM
analytical estimated results: Samples T-1 NONE DETECTED; Sample T-2, 3
(pantry &utility, trace (TR) <1% CHRYSOTILE ASBESTOS. This material is
classified as ACM, unless “Point Count” analysis is done for these surfacing
material samples with trace and the joint samples above in paragraph 7 are point
counted and the composite results are less than 1% Chrysotile asbestos. As is,
HealthSafe concludes that this is ACM and will required asbestos abatement for
removal and disposal.
9. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [MUDRM-OP-C/W-J-1,
2]. These composite layered taped and joint compounded drywall materials were 09/14/2017
on mudroom walls and ceiling with an orange peel surfacing material/texture.
The estimated impact area of remodel was more than 32 sf, but less than 1,000 sf,
requiring a minimum of at least two composite core samples of all drywall layers.
The PLM analytical estimated results: J-1: CHRYSOTILE ASBESTOS 2%; J-
2: (TR) <1% CHRYSOTILE ASBESTOS within compound matrix. This
material is classified as ACM and will required asbestos abatement for removal
and disposal.
10. A homogenous spray-applied orange peel surfacing material/texture [MDRM-OP-C/W-
T-1, 2, 3]. This surfacing material/texture was on mudroom walls and ceiling
with an orange peel surfacing material/texture. The estimated impact area was
more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three
surfacing/texture material samples. The PLM analytical estimated results:
Samples T-1, 3: CHRYSOTILE ASBESTOS 2%; Sample T-2: trace (TR)
<1% CHRYSOTILE ASBESTOS. This material is classified as ACM and will
required asbestos abatement for removal and disposal.
11. A homogenous taped and joint compounded drywall system (classified as a
miscellaneous material as a complete integral system) [CRTK-OP-C/W-J-1, 2].
These composite layered taped and joint compounded drywall materials were on
caretaker walls and ceiling with an orange peel surfacing material/texture. The
estimated impact area of remodel was more than 32 sf, but less than 1,000 sf,
requiring a minimum of at least two composite core samples of all drywall layers.
The PLM analytical estimated results: CHRYSOTILE ASBESTOS 2%, 3%.
This material is classified as ACM and will required asbestos abatement for
removal and disposal.
12. A homogenous spray-applied orange peel surfacing material/texture [CRTK-OP-C/W-T-
1, 2, 3]. This surfacing material/texture was on caretaker room walls and ceiling
with an orange peel surfacing material/texture. The estimated impact area was
more than 32 sf, but less than 1,000 sf, requiring a minimum of at least three
surfacing/texture material samples. The PLM analytical estimated results: trace
(TR) <1% CHRYSOTILE ASBESTOS. This material is classified as ACM,
unless “Point Count” analysis is done for these surfacing material samples with
trace and the joint samples above in paragraph 11 are point counted and the
composite results are less than 1% Chrysotile asbestos. As is, HealthSafe
concludes that this is ACM and will required asbestos abatement for removal and
disposal.
13. Miscellaneous suspect ACM roofing paper [RFP-T]. The PLM analytical estimated
results: NONE DETECTED.
A total of 36 suspect homogenous ACM/ACBM bulk samples were collected and 36 samples
were analyzed. The bulk samples were analyzed by PLM by a NVLAP accredited laboratory in
accordance with Colorado State Regulation 8 for the presence of asbestos mineral fibers. There
was NO asbestos in 6 samples. CHRYSOTILE >2-3% present in 23 samples; trace Chrysotile
<1% in 15 samples analyzed (total trace amounts also present within some CHRYSOTILE >2-
3% samples)
See supporting Reservoirs Environmental, Inc., data: report # RES 330918-1
HEALTHSAFE CONCLUSIONS:
09/14/2017
There is CHRYSOTILE >1% present in 23 bulk samples of the suspect building materials
slated to be impacted by renovation/demolition. This material is classified as ACM and will
required asbestos abatement for removal and disposal.
TRACE Chrysotile <1% is present in 15 samples analyzed. State regulation requires all
TRACE samples be “Point Counted”, unless assumed ACM. In order for the TRACE samples to
be confirmed as less than 1.0%, they must be “Point Counted”. In the case of this particular
inspection and set of samples, HealthSafe has concluded that ALL drywall systems on the
property are classified as ACM. There are 3 different homogenous drywall systems with
Chrysotile asbestos
Sincerely Submitted,
Mark Bridges
Reviewed by Jim Baker
09/14/2017
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc
Subcontract Number:NA
Laboratory Report:RES 330918-1
Project # / P.O. # Bill Guth
Project Description:308 N. 1st St Aspen CO 81611
RES 330918-1
Sincerely,
is the job number assigned to this study. This report is considered highly confidential
and the sole property of the customer.Reservoirs Environmental,Inc.will not discuss any part of this study with
personnel other than those of the client.The results described in this report only apply to the samples analyzed.
This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the
U.S.Government.This report shall not be reproduced except in full,without written approval from Reservoirs
Environmental,Inc.Samples will be disposed of after sixty days unless longer storage is requested.If you have any
questions about this report, please feel free to call 303-964-1986.
Jeanne Spencer
President
September 9, 2015
Dear Customer,
Reservoirs Environmental,Inc.is an analytical laboratory accredited for the analysis of Industrial Hygiene and
Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP),Lab Code 101896-0
for Transmission Electron Microscopy (TEM)and Polarized Light Microscopy (PLM)analysis and the American
Industrial Hygiene Association (AIHA),Lab ID 101533 -Accreditation Certificate #480 for Phase Contrast
Microscopy (PCM)analysis.This laboratory is currently proficient in both Proficiency Testing and PAT programs
respectively.
Reservoirs Environmental,Inc.has analyzed the following samples for asbestos content as per your request.The
analysis has been completed in general accordance with the appropriate methodology as stated in the attached
analysis table. The results have been submitted to your office.
HealthSafe Inspections, Inc.
1052 Vine St.
Aspen CO 81611
P: 303-964-1986
F: 303-477-4275
5801 Logan Street, Suite 100 Denver, CO 80216
Page 1 of 1
1-866-RESI-ENV
www.reilab.com
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000UBRCLT-OP-C/W-J-1 EM 1483649 White plasterA 1 ND
1000Beige paint w/ white compoundB 3 TR Chrysotile
970Beige joint compoundC 4 3 Chrysotile
199White tapeD 12 ND
6535White/brown drywallE 80 ND
970UBRCLT-OP-C/W-J-2 EM 1483650 Tan compoundA TR 3 Chrysotile
1000Pink/beige paintB 3 ND
199White tapeC 12 ND
1000White joint compoundD 20 ND
1000White texture w/ beige paintE 20 ND
6040White/brown drywallF 45 ND
970UBRCLT-OP-C/W-T-1 EM 1483651 Tan compoundA 15 3 Chrysotile
595Brown/white drywallB 35 ND
1000White paintC 50 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 1 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
595UBRCLT-OP-C/W-T-2 EM 1483652 Brown/white drywallA 5 ND
970Tan compoundB 25 3 Chrysotile
1000White paintC 70 ND
2080UBRCLT-OP-C/W-T-3 EM 1483653 Brown/white drywallA 35 ND
1000White compound w/ white paintB 65 ND
970UBR-OP-C/W-T-4 EM 1483654 Tan compoundA 4 3 Chrysotile
595Brown/white drywallB 16 ND
1000Tan/multi-colored paintC 80 ND
595UBR-OP-C/W-T-5 (Sample Labeled
UHLL-OP-C/W-T-5)
EM 1483655 Brown/white drywallA 5 ND
1000White compound w/ beige/white paintB 95 ND
2080STRCL-OP-C/W-J-1 EM 1483656 White tape w/ white paintA 10 ND
970Tan compoundB 25 3 Chrysotile
8020White/brown drywallC 65 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 2 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
970STRCL-OP-C/W-J-2 EM 1483657 Beige joint compoundA 1 3 Chrysotile
1000White paint w/ beige compoundB 2 TR Chrysotile
1000White plasterC 5 ND
199White tapeD 7 ND
991Beige granular plasterE 15 ND
1000White caulkF 20 ND
7525White/brown drywallG 50 ND
970STRCL-OP-C/W-T-1 EM 1483658 Beige compoundA 20 3 Chrysotile
298Brown drywall paperB 25 ND
1000White paintC 55 ND
1000ENTBTH-OP-C/W-T-2 EM 1483659 White compound w/ white/gray paintA 100 ND
1090ENT-OP-C/W-T-3 EM 1483660 Brown/white drywallA 1 ND
1000White compound w/ white/gray paintB 99 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 3 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
298LBR-OP-C/W-T-4 EM 1483661 Brown drywall paperA 3 ND
980White compoundB 37 2 Chrysotile
1000Tan/white paintC 60 ND
1000LBR-OP-C/W-T-5 EM 1483662 Tan/white paint w/ a trace of tan compoundA 40 TR Chrysotile
1090Brown/white drywallB 60 ND
980MBRCL-FLT-C/W-J-1 EM 1483663 White joint compoundA 2 2 Chrysotile
980White compoundB 3 2 Chrysotile
1000White paintC 5 ND
199White tapeD 10 ND
7030White/brown drywallE 80 ND
1000MBRCL-FLT-C/W-T-1 EM 1483664 White compoundA 3 TR Chrysotile
298Brown drywall paperB 27 ND
1000White paintC 70 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 4 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000MBRCL-FLT-C/W-T-2 EM 1483665 White compoundA 1 TR Chrysotile
298Brown drywall paperB 19 ND
1000White paintC 80 ND
5545MBRCL-FLT-C/W-T-3 EM 1483666 White paint w/ brown drywall paperA 100 ND
970KTCNTH-FLT-C/W-J-1 EM 1483667 Tan compoundA TR 3 Chrysotile
2080White tape w/ white paintB 10 ND
3070White fibrous material w/ white/multi-colored paintC 20 ND
7525White/brown drywallD 70 ND
1000KTCNTH-FLT-C/W-J-2 EM 1483668 White joint compoundA 2 TR Chrysotile
1000White/yellow paint w/ white compoundB 3 TR Chrysotile
199White tapeC 15 ND
7030White/brown drywallD 80 ND
6040KTCNTH-FLT-C/W-T-1 EM 1483669 White/multi-colored paint w/ white fibrous materialA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 5 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000KTCNTH-FLT-C/W-T-2 EM 1483670 White compoundA 4 TR Chrysotile
298Brown drywall paperB 6 ND
1000White paintC 90 ND
298KTCNTH-FLT-C/W-T-3 EM 1483671 Brown drywall paperA 30 ND
1000White paint w/ a trace of white compoundB 70 TR Chrysotile
980MUDRM-OP-C/W-J-1 EM 1483672 White joint compoundA 3 2 Chrysotile
199White tapeB 7 ND
1000White texture w/ yellow/white paintC 10 ND
980White compoundD 15 2 Chrysotile
6535White/brown drywallE 65 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 6 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000MDRM-OP-C/W-J-2 EM 1483673 Yellow paintA 3 ND
1000White joint compoundB 3 TR Chrysotile
1000White compoundC 4 TR Chrysotile
199White tapeD 10 ND
8020White/brown drywallE 80 ND
980MDRM-OP-C/W-T-1 EM 1483674 White compoundA 20 2 Chrysotile
1000Yellow/white paintB 80 ND
298MDRM-OP-C/W-T-2 EM 1483675 Brown drywall paperA 40 ND
1000Yellow/white paint w/ a trace of white compoundB 60 TR Chrysotile
980MDRM-OP-C/W-T-3 EM 1483676 White compoundA 10 2 Chrysotile
1000Yellow/white paintB 90 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 7 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
970CRTK-OP-C/W-J-1 EM 1483677 White joint compoundA 4 3 Chrysotile
980White compoundB 5 2 Chrysotile
1000Beige paintC 10 ND
199White tapeD 16 ND
6535White/brown drywallE 65 ND
970CRTK-OP-C/W-J-2 EM 1483678 White joint compoundA 3 3 Chrysotile
970White compoundB 4 3 Chrysotile
1000Beige paintC 4 ND
199White tapeD 9 ND
7525White/brown drywallE 80 ND
1000CRTK-OP-C/W-T-1 EM 1483679 White compoundA 4 TR Chrysotile
2080Brown/white drywallB 16 ND
1000Off white/white paintC 80 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 8 of 9
09/14/2017
RES Job Number:
Client:
Client Project Number / P.O.:
Client Project Description:
Date Samples Received:
Turnaround:
Date Samples Analyzed:
RES 330918-1
HealthSafe Inspections, Inc.
Bill Guth
308 N. 1st St Aspen CO 81611
September 02, 2015
3-5 Day
September 09, 2015
TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME
Reservoirs Environmental, Inc.
Reservoirs Environmental QA Manual
Effective January 1, 2015
Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc
RESERVOIRS ENVIRONMENTAL INC.
NVLAP Lab Code 101896-0
Client
Sample
Number
Lab
ID Number
L
A
Y
E
R
Mineral
Method:EPA 600/R-93/116 - Short Report, Bulk
Physical
Description
Sub
Part
(%)
Visual
Estimate
(%)
ND=None Detected
TR=Trace, <1% Visual Estimate
Trem/Act=Tremolite/Actinolite
Non
Asbestos
Fibrous
Components
(%)
Non-
Fibrous
Components
(%)
Asbestos Content
1000CRTK-OP-C/W-T-2 EM 1483680 White compoundA 3 TR Chrysotile
298Brown drywall paperB 7 ND
1000Off white/white paintC 90 ND
1000CRTK-OP-C/W-T-3 EM 1483681 White compoundA 3 TR Chrysotile
1000Off white/white paintB 97 ND
970LIV-OP-C/W-T-6 EM 1483682 Beige joint compoundA 5 3 Chrysotile
970Beige compoundB 10 3 Chrysotile
199White tapeC 25 ND
1000Beige/white paintD 30 ND
298Brown drywall paperE 30 ND
970DIN-OP-C/W-T-7 EM 1483683 Tan compoundA 1 3 Chrysotile
298Brown drywall paperB 6 ND
1000Tan/white paintC 93 ND
3565RFPR-T EM 1483684 Black feltA 100 ND
TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.
Analyst / Data QAAnalystAnalystAnalystAnalyst
P: 303-964-1986
F: 303-477-4275
1-866-RESI-ENV
www.reilab.com
5801 Logan Street, Suite 100, Denver, CO 80216
Page 9 of 9
09/14/2017
09/14/2017
09/14/2017
09/14/2017
09/14/2017
09/14/2017