HomeMy WebLinkAboutFile Documents.124 W Hallam St.0025.2017 (5).ARBKMarkup Summary 7-28-2017 Page: 1 Author: amyg File Name: LANDSCAPE DRAWINGS_REVISION 1.2019.06.29.pdf LANDSCAPE DRAWINGS_REVISION 1.2019.06.29.pdf (2) Page: 1 Author: amyg File Name: LANDSCAPE DRAWINGS_REVISION 1.2019.06.29.pdf Please revise to eliminate this planting bed, as represented in architectural site plan. Page: 5 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf After inspection of historic framing, there is no door at 102. Please delete from design. PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf (18) Page: 5 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Examine historic framing at 101 and determine if both a code compliant entry door and transom will fit in the rough opening. Revise design for review and approval by HPC staff. Please revise to eliminate this planting bed, as represented in architectural site plan. After inspection of historic framing, there is no door at 102. Please delete from design. Examine historic framing at 101 and determine if both a code compliant entry door and transom will fit in the rough opening. Revise design for review and approval by HPC staff. PLANTING BED HAS BEEN ELIMINATED. SEE PLAN LS-10.0 DOOR 102 HAS BEEN REMOVED FROM PLAN, ELEVATION, AND DOOR SCHEDULE FRAMING REVEALS THERE IS SUFFICIENT DIMENSIONS FOR DOOR AND TRANSOM 09/14/2017 Page: 6 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Window 1: Exposed framing has revealed the historic rough opening. Please adjust design. Window 2: Please review exposed framing and adjust design if appropriate. This is labeled as an existing window in schedule, but it is new. Window 3: Match historic window 6 Window 7: Please review exposed framing and adjust design if appropriate. Window 8: Please review exposed framing and adjust design if appropriate. Window 11: Match historic window 9 Window 12: Confirm historic rough opening in field and adjust design Window 18: Exposed framing shows there was no window in this location. Please delete. Window 19/20: Please review exposed framing and adjust design if appropriate. Window 21/22: This is labeled as an existing window in schedule, but it is new. Window 27/28: Exposed framing reveals one double hung centered in the gable end. Historic sill (and maybe header) are in place. Confirm historic rough opening in field and adjust design. Window 29: Please review exposed framing and adjust design if appropriate. Window 30: Review condition in field. Exposed framing reveals this was a pair of double hung windows. The historic jamb was sliced in half horizontally to reduce the glazing. Please confirm historic rough opening and restore to original design. Page: 10 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Appears to be original siding. All original siding is to be retained if feasible. Study on site with HPC staff after exterior demolition work. Use this area of siding as model for new siding. Window 1: Exposed framing has revealed the historic rough opening. Please adjust design. Window 2: Please review exposed framing and adjust design if appropriate. This is labeled as an existing window in schedule, but it is new.Window 3: Match historic window 6Window 7: Please review exposed framing and adjust design if appropriate. Window 8: Please review exposed framing and adjust design if appropriate. Window 11: Match historic window 9Window 12: Confirm historic rough opening in field and adjust design Window 18: Exposed framing shows there was no window in this location. Please delete. Window 19/20: Please review exposed framing and adjust design if appropriate. Window 21/22: This is labeled as an existing window in schedule, but it is new.Window 27/28: Exposed framing reveals one double hung centered in the gable end. Historic sill (and maybe header) are in place. Confirm historic rough opening in field and adjust design.Window 29: Please review exposed framing and adjust design if appropriate. Window 30: Review condition in field. Exposed framing reveals this was a pair of double hung windows. The historic jamb was sliced in half horizontally to reduce the glazing. Please confirm historic rough opening and restore to original design. Appears to be original siding. All original siding is to be retained if feasible. Study on site with HPC staff after exterior demolition work. Use this area of siding as model for new siding. PER THE WALK-THROUGH WITH OAC (OWNER, ARCHITECT, CONTRACTOR) AND HPC, FRAMING INFORMATION WAS REVIEWED AND REVISED. SEE UPDATED WINDOWS SCHEDULE AND LIST BELOW: WINDOW 1 OPERABLE DOUBLE HUNG IF POSSIBLE WINDOW 2 NO CHANGES WINDOW 3 WILL MATCH #6 WINDOW 7 TO BECOME MORE NARROW PER WINDOW 8 WINDOW 8 TO SET WINDW 7 WIDTH WINDOW 11 MATCH WINDOW 9 WINDOW 12 DIMENSIONS HAVE BEEN REVISED WINDOW 18 REMOVED WINDOWS 19/20 R.O. REVISED WINDOWS 21/22 LABELED AS NEW/GRABILL WINDOWS 27/28 CHNAGED TO SINGLE DOUBLE HUNG WINDOW 29 TO BE INCLUDED IN PROJECT WINDOW 30 SIZE (HEIGHT) INCREASED. SEE ELEVATIONS SIDNG THAT APEARS TO BE ORIGINAL AT WEST/NORTH FACADES WILL BE RETAINED IF POSSIBLE. SAVED SIDING WILL BE USED AS MODEL FOR NEW/ADDED SIDING 09/14/2017 Page: 10 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Page: 10 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Appears to be original siding. All original siding is to be retained if feasible. Study on site with HPC staff after exterior demolition work. Use this area of siding as model for new siding. Page: 10 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Page: 11 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Change stone steps to wood steps. Page: 11 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Change note to "Pin lights to be approved by HPC prior to installation." Appears to be original siding. All original siding is to be retained if feasible. Study on site with HPC staff after exterior demolition work. Use this area of siding as model for new siding. Change stone steps to wood steps. Change note to "Pin lights to be approved by HPC prior to installation." SIDNG THAT APEARS TO BE ORIGINAL AT WEST/NORTH FACADES WILL BE RETAINED IF POSSIBLE. SAVED SIDING WILL BE USED AS MODEL FOR NEW/ADDED SIDING SEE A-100.00 STONE STEPS CHANGED TO WOOD PIN LIGHTS NOT APPROVED BY HPC NEW LIGHT FIXTURES SELECTED 09/14/2017 Page: 11 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Change note to "Stone paving must be approved by HPC prior to installation." Page: 19 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Study any remaining original porch rafters to determine historic pitch and revise if appropriate. Page: 19 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Update angle of PV panels based on energy consultant feedback. Page: 19 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Remove window 18 and revise window 31. Page: 19 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Remove note and door 102. Change note to "Stone paving must be approved by HPC prior to installation." Study any remaining original porch rafters to determine historic pitch and revise if appropriate. Update angle of PV panels based on energy consultant feedback. Remove window 18 and revise window 31. Remove note and door 102. SEE A-100.00 NOTE HAS BEEN ADJUSTED SEE EXTERIOR ELEVATIONS: PV PANEL ANGLES ADJUSTED SEE EXTERIOR ELEVATIONS: REMOVED & REVISED DOOR HAS BEEN REMOVED KORU HAS STUDIED ORIGINAL PORCH RAFTERS 09/14/2017 Page: 20 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Remove note. Revise design based on framing evidence. Page: 21 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Change to wood entry steps. Page: 35 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf Add note "Provide shingle sample for review and approval by HPC staff." Page: 48 Author: amyg File Name: PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf This conflicts with roof plan shown on A-113. Please revise design or clarify location of this roof vent. Remove note. Revise design based on framing evidence. Change to wood entry steps. Add note "Provide shingle sample for review and approval by HPC staff." This conflicts with roof plan shown on A-113. Please revise design or clarify location of this roof vent. HAS BEEN CHANGED TO SINGLE DOUBLE-HUNG WINDOW. SEE A-301.00 SEE A-100.00 STONE STEPS CHANGED TO WOOD NOTE ADDED - SAMPLE TO BE PROVIDED (CUT, NOT SHAKE SHINGLE) DETAIL SECTION A-730.00 HAS BEEN REVISED; CHIMNEY DOES NOT VENT DIRECTLY ABOVE FIRLEPLACE AS PREVIOUSLY SHOWN 09/14/2017