HomeMy WebLinkAboutFile Documents.124 W Hallam St.0025.2017 (5).ARBKMarkup Summary 7-28-2017
Page: 1
Author: amyg
File Name: LANDSCAPE DRAWINGS_REVISION
1.2019.06.29.pdf
LANDSCAPE DRAWINGS_REVISION 1.2019.06.29.pdf (2)
Page: 1
Author: amyg
File Name: LANDSCAPE DRAWINGS_REVISION
1.2019.06.29.pdf
Please revise to eliminate this
planting bed, as represented in
architectural site plan.
Page: 5
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
After inspection of historic
framing, there is no door at 102.
Please delete from design.
PERMIT REVISIONS 1-ARCHITECTURAL.2017.06.29.pdf (18)
Page: 5
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Examine historic framing at 101
and determine if both a code
compliant entry door and
transom will fit in the rough
opening. Revise design for
review and approval by HPC
staff.
Please revise to eliminate this planting bed,
as represented in architectural site plan.
After inspection of historic framing, there is no door at 102. Please
delete from design.
Examine historic framing at 101 and determine if both a code
compliant entry door and transom will fit in the rough opening.
Revise design for review and approval by HPC staff.
PLANTING BED HAS BEEN
ELIMINATED. SEE PLAN LS-10.0
DOOR 102 HAS BEEN REMOVED
FROM PLAN, ELEVATION, AND
DOOR SCHEDULE
FRAMING REVEALS THERE IS
SUFFICIENT DIMENSIONS FOR
DOOR AND TRANSOM
09/14/2017
Page: 6
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Window 1: Exposed framing has
revealed the historic rough
opening. Please adjust design.
Window 2: Please review
exposed framing and adjust
design if appropriate. This is
labeled as an existing window in
schedule, but it is new.
Window 3: Match historic
window 6
Window 7: Please review
exposed framing and adjust
design if appropriate.
Window 8: Please review
exposed framing and adjust
design if appropriate.
Window 11: Match historic
window 9
Window 12: Confirm historic
rough opening in field and adjust
design
Window 18: Exposed framing
shows there was no window in
this location. Please delete.
Window 19/20: Please review
exposed framing and adjust
design if appropriate.
Window 21/22: This is labeled as
an existing window in schedule,
but it is new.
Window 27/28: Exposed framing
reveals one double hung
centered in the gable end.
Historic sill (and maybe header)
are in place. Confirm historic
rough opening in field and adjust
design.
Window 29: Please review
exposed framing and adjust
design if appropriate.
Window 30: Review condition in
field. Exposed framing reveals
this was a pair of double hung
windows. The historic jamb was
sliced in half horizontally to
reduce the glazing. Please
confirm historic rough opening
and restore to original design.
Page: 10
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Appears to be original siding. All
original siding is to be retained if
feasible. Study on site with HPC
staff after exterior demolition
work. Use this area of siding as
model for new siding.
Window 1: Exposed framing has revealed the historic rough opening. Please adjust design.
Window 2: Please review exposed framing and adjust design if appropriate. This is labeled as an existing window in schedule, but it is new.Window 3: Match historic window 6Window 7: Please review exposed framing and adjust design if appropriate.
Window 8: Please review exposed framing and adjust design if appropriate. Window 11: Match historic window 9Window 12: Confirm historic rough opening in field and adjust design
Window 18: Exposed framing shows there was no window in this location. Please delete.
Window 19/20: Please review exposed framing and adjust design if appropriate. Window 21/22: This is labeled as an existing window in schedule, but it is new.Window 27/28: Exposed framing reveals one double hung centered in the gable end. Historic sill (and maybe header) are in place. Confirm
historic rough opening in field and adjust design.Window 29: Please review exposed framing and adjust design if appropriate. Window 30: Review condition in field. Exposed framing reveals this was a pair of double hung windows. The historic jamb was sliced in half
horizontally to reduce the glazing. Please confirm historic rough opening and restore to original design.
Appears to be original siding. All original
siding is to be retained if feasible. Study
on site with HPC staff after exterior
demolition work. Use this area of siding
as model for new siding.
PER THE WALK-THROUGH WITH OAC
(OWNER, ARCHITECT, CONTRACTOR) AND HPC,
FRAMING INFORMATION WAS REVIEWED AND REVISED.
SEE UPDATED WINDOWS SCHEDULE AND LIST BELOW:
WINDOW 1 OPERABLE DOUBLE HUNG IF POSSIBLE
WINDOW 2 NO CHANGES
WINDOW 3 WILL MATCH #6
WINDOW 7 TO BECOME MORE NARROW PER WINDOW 8
WINDOW 8 TO SET WINDW 7 WIDTH
WINDOW 11 MATCH WINDOW 9
WINDOW 12 DIMENSIONS HAVE BEEN REVISED
WINDOW 18 REMOVED
WINDOWS 19/20 R.O. REVISED
WINDOWS 21/22 LABELED AS NEW/GRABILL
WINDOWS 27/28 CHNAGED TO SINGLE DOUBLE HUNG
WINDOW 29 TO BE INCLUDED IN PROJECT
WINDOW 30 SIZE (HEIGHT) INCREASED. SEE ELEVATIONS
SIDNG THAT APEARS TO BE ORIGINAL AT WEST/NORTH
FACADES WILL BE RETAINED IF POSSIBLE. SAVED
SIDING WILL BE USED AS MODEL FOR NEW/ADDED SIDING
09/14/2017
Page: 10
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Page: 10
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Appears to be original siding. All
original siding is to be retained if
feasible. Study on site with HPC
staff after exterior demolition
work. Use this area of siding as
model for new siding.
Page: 10
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Page: 11
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Change stone steps to wood
steps.
Page: 11
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Change note to "Pin lights to be
approved by HPC prior to
installation."
Appears to be original siding. All original siding is
to be retained if feasible. Study on site with HPC
staff after exterior demolition work. Use this area
of siding as model for new siding.
Change stone steps to
wood steps.
Change note to "Pin
lights to be approved by
HPC prior to
installation."
SIDNG THAT APEARS TO BE ORIGINAL AT WEST/NORTH
FACADES WILL BE RETAINED IF POSSIBLE. SAVED
SIDING WILL BE USED AS MODEL FOR NEW/ADDED SIDING
SEE A-100.00
STONE STEPS CHANGED TO WOOD
PIN LIGHTS NOT APPROVED BY HPC
NEW LIGHT FIXTURES SELECTED
09/14/2017
Page: 11
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Change note to "Stone paving
must be approved by HPC prior
to installation."
Page: 19
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Study any remaining original
porch rafters to determine
historic pitch and revise if
appropriate.
Page: 19
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Update angle of PV panels
based on energy consultant
feedback.
Page: 19
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Remove window 18 and revise
window 31.
Page: 19
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Remove note and door 102.
Change note to "Stone
paving must be
approved by HPC prior
to installation."
Study any remaining
original porch rafters to
determine historic pitch
and revise if
appropriate.
Update angle of PV
panels based on energy
consultant feedback.
Remove window
18 and revise
window 31.
Remove note and
door 102.
SEE A-100.00
NOTE HAS BEEN ADJUSTED
SEE EXTERIOR ELEVATIONS:
PV PANEL ANGLES ADJUSTED
SEE EXTERIOR ELEVATIONS:
REMOVED & REVISED
DOOR HAS BEEN REMOVED
KORU HAS STUDIED
ORIGINAL PORCH RAFTERS
09/14/2017
Page: 20
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Remove note. Revise design
based on framing evidence.
Page: 21
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Change to wood entry steps.
Page: 35
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
Add note "Provide shingle
sample for review and approval
by HPC staff."
Page: 48
Author: amyg
File Name: PERMIT REVISIONS
1-ARCHITECTURAL.2017.06.29.pdf
This conflicts with roof plan
shown on A-113. Please revise
design or clarify location of this
roof vent.
Remove note. Revise design
based on framing evidence.
Change to wood entry
steps.
Add note "Provide shingle sample for
review and approval by HPC staff."
This conflicts with roof plan shown
on A-113. Please revise design or
clarify location of this roof vent.
HAS BEEN CHANGED TO SINGLE
DOUBLE-HUNG WINDOW.
SEE A-301.00
SEE A-100.00
STONE STEPS CHANGED TO WOOD
NOTE ADDED - SAMPLE TO BE PROVIDED
(CUT, NOT SHAKE SHINGLE)
DETAIL SECTION A-730.00 HAS BEEN
REVISED; CHIMNEY DOES NOT VENT
DIRECTLY ABOVE FIRLEPLACE AS
PREVIOUSLY SHOWN
09/14/2017