Loading...
HomeMy WebLinkAboutMaster Permit.131 W Bleeker St.0007.2017.ARBUCity of Aspen General / Building Permit Application 130 South Galena Street, Aspen, Colorado 81611 Phone (970) 920-5090 Fax (970) 920-5440 Legal Description Block Address Owner's Authorized Agent Phone No.Alternate Phone No.E-mail E-mail Permit Type: BD CO DE FD FN MH MS RF SN Census Code Occupancy Group Lot Area Zone District No. of Stories Parks Energy Code Ped. Amenity Water Permit Fee School Ded. Sanitation Plan Check TDM Impact CMP REMP Zoning Fire District Water Tap Stormwater fee in lieu Other Cons. Mit.Eng. Review Demo/FdEx Fee Other RECEIPTS PLEASE CALL FOR AN INSPECTION TO (970) 920-5448 PERMIT NO. Park Impact Application Accepted by: Date: Date: Plan Check by: Date: Approved for issuance by: G.I.S. OFFICE COPY APPROVALS Authorized by:Date Date: Engineering Env. Health County Use Tax HPC City Use Tax Lot Tract or Subdivision Parcel ID (call 920-5160) Best Contact Name/Phone/Cell Phone/E-mail Phone No E-mailOwner Job Address E-mail PLANS LOCATION # Historic Property?HPC Certificate of Appropriateness Contractor Signature Print Name Use of Building: Class of Work: Valuation of Work $Existing Sq. Ft. of Unit: Cons. Mit. SqFt.Disturbed Area Presubmittal by: NOTICE: Separate permits are required for electrical, plumbing or mechanical work. This permit becomes null and void if work or construction authorized is not commenced within 180 days, or if construction or work is suspended or abandoned for a period of 180 days at any time after work has commenced. Date Description of work: Date: Alarm System Req.Fire Sprinkler Req. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of work will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other state or local law regulating construction or the performance of construction.It is my responsibility to review the approved plans and any comments that are contained thereon and see that the structure and/or project is built in compliance with all applicable codes. USE TAX:The General Contractor or Owner Builder is required to pay a Use Tax Deposit to both the City of Aspen (2.1%, first $100,000 is exempt) and Pitkin County (0.5%,no exemption)on the building permit at the time of issuance. All sub-permits pulled under a building permit are paid by this deposit payment and should not pay use tax. Occupancy Load PERMIT FEES Size of Building (Total Sq. Ft.)No. of Parking Spaces covered: uncovered: No. Bedrooms added:No. Bathrooms added: Cost Aspen San. Dist. FEES Housing Cash- in-lieu Type of Construction: Owner Signature (if Owner/Builder) THIS IS A PERMIT ONLY WHEN VALIDATED. WORK STARTED WITHOUT PERMIT WILL BE DOUBLE FEE. FEES Issued by: Architect Phone No.Alternate Phone No. Zoning License No. Date No. of Dwellings FOR CITY USE ONLY Deed Restricted General Contractor Phone No. Food Service in this Building? Print Name Sq. Ft. This Permit: Cost yes no Single Family Multi-Family Commercial/Residential Commercial OtherNewAdditionAlterationRepair Other nonoyesyes noyesyes Move Tenant Finish Demo no 118 NORTH 1ST STREET 58A CITY AND TOWNSITE OF ASPEN 273512439001 ADAM ROTHBERG / 970-948-0480 / adamrothberg@comcast.net 118 NORTH FIRST LLC 623 E HOPKINS AVE 970-920-1280 LYNN@ASPENSTARWOOD.COM Adam Rothberg 970-948-0480 adamrothberg@comcast.net ROTHBERG DEVELOPMENT 970-948-0480 ADAMROTHBERG@COMCAST.NET THUNDERBOWL ARCHITECTS 970-274-1421 RYAN@THUNDERBOWLARCHITECTS.COM 2464 0INTERIOR REMODEL $750,000 2,464 2,464 X X ADAM ROTHBERG 09/22/2015 X JH 4/18/17 434 R3 X X VB X 2461 2 CS 3/28/17 AS 4/27/17 TK 2/15/17 PM 5/8/17 SW 4/26/17 0007.2017.ARBU 131 W BLEEKER 2572.50 11147.50 325.00 UTILITIES 343.00 1318.24X2 X2 1875.00 SANITATION 3203.64 6825.00 17150.00 City of Aspen 130 South Galena Street, Aspen, Colorado 81611 Phone (970) 920-5090 Fax (970) 920-5440 Legal Description Block E-mail Address Name Phone No. Name Phone No.Alternate Phone No. Mailing address City Zip Mailing address Engineer of Record PLEASE PROVIDE ANY ADDITIONAL INFORMATION THAT MAY HELP US CONTACT YOU FOR ANY QUESTIONS REGARDING YOUR BUILDING PERMIT APPLICATION Other Contact Name Phone No.Alternate Phone No. PERMIT NO. Permit TypeJob Address Owner General Contractor CONTACT INFORMATION Owner's Authorized Agent E-mail Address Mailing address City Zip E-mail Address Alternate Phone No. PERMIT INFORMATION Lot Tract or Subdivision Parcel ID (call 920-5160) Name Phone No.Alternate Phone No. City Zip Name Phone No. Mailing address Alternate Phone No. Architect or Designer of Record Name Phone No.Alternate Phone No. City Zip City Zip Mailing address General / Building Permit Contact Sheet E-mail Address E-mail Address Mailing address City Zip E-mail Address Landscape Architect of Record Name Phone No.Alternate Phone No. E-mail Address Mailing address City Zip 118 NORTH 1ST STREET A 58 CITY AND TOWNSITE OF ASPEN 273512439001 118 NORTH FIRST LLC 970-920-1280 623 E. HOPKINS ASPEN 81611 ADAM ROTHBERG 970-948-0480 ADAMROTHBERG@COMCAST.NET ROTHBERG DEVELOPMENT 970-948-0480 822 Bonita Dr Aspen, CO 81611 ADAMROTHBERG@COMCAST.NET THUNDERBOWL ARCHITECTS 970-274-1421 300 SOUTH SPRING STRET, SUITE 201 ASPEN 81611 RYAN@THUNDERBOWLARCHITECTS.COM HEIN BRUTSAERT 970-300-1003 133 PROSPECTOR ROAD ASPEN 81611 HEIN@BRUTSTSAERTENGINEERING.COM 0007.2017.ARBU 131 W BLEEKER RETAIN F'OR PERMANENT F'ILB CITY OF ASPEN COMMUNITY DEVELOPMENT VALUATIOJ ADJUSTMENT POLICY Propertyaoo..r* 118'N lsh S+ permitNumber: This valuation adjustment only applies to projects with a valuation greater than $100,000 calculated according to the applicable valuation policy. The owner or authorized agent must sign this understanding. City of Aspen Ordinance 1No. 55, Series of 1999 Chapter 8.16 adopts the 2003 International Residential Code (IRC) with certain amendments and Chapter 8.20 adopts the 2003 International Building Code (IBC) with certain amendments. The codes def-rne building valuation as follows: IRC RL08.3 Building permit vrtlutttions. Building permit ttalucttion shall inclade total value o.f'the work ./br u'hich a permit is being issued, such crs electrical, gcrs, mechanical, pluntbing equipntent and other pernlanen l,\)slenLs', including materiul s nnd labor. IBC 108.3 Buildin:g permit valuqtions. The applicant for a permit shall provide an estimated permit value at time of ap,olication. Permit valuations shall include total value of work, including materials and labor, for which the perntit is being issued, such as electrical, gas, me<:hanical, plumbing equipment and permanent systems. If, in the opinion of the building fficial, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building fficial. Final building permit valuation shall be set by the building fficiat. (a) For the purpose of valuation adjustment a detailed final construction cost estimate, including the items referenced above, shall be considered for approval. (b) If a valuation adjustment is made the building plan review and building perrmit fees will be adjusted accordingly. (c) The City Use Tax Auditor will be notified of the adjustment and an audit will be performed. (d) Building plan review, building permit fee and use tax adjustments will be refunded or collected when the final reconciliation return is filed and a use tax audit is complete. (e) Any fees due must be paid. Unpaid fees may be subject to collection procedures of the City of Aspen. The undersienedhas read this policy and will comply with its provisions as a basis for theissuance of a building permit for t. fu6upr Owner or authori 's signature Print Name COMMUNITY DEVELOPMENT DEPARTMENT November, 2014 City of Aspen | 130 S. Galena St. | (970) 920-5090 Permit No. _______________ Homeowner Association Compliance Policy All applications for a building permit within the City of Aspen are required to include a certification of compliance with applicable covenants and homeowner association policies. The certification must be signed by the property owner or Attorney representing the property owner. The following certification shall accompany the application for a permit. Subject Property: _______________________________________________ _______________________________________________ _______________________________________________ I, the property owner, certify as follows: (pick one) □ This property is not subject to a homeowners association or other form of private covenant. □ This property is subject to a homeowners association or private covenant and the improvements proposed in this building permit do not require approval by the homeowners association or covenant beneficiary. □ This property is subject to a homeowners association or private covenant and the improvements proposed in this building permit have been approved by the homeowners association or covenant beneficiary. I understand the City of Aspen does not interpret, enforce, or manage the applicability, meaning or effect of private covenants or homeowner association rules or bylaws. I understand that this document is a public document. Owner signature: _________________________ date:___________ Owner printed name: _________________________ or, Attorney signature: _________________________ date:___________ Attorney printed name: _________________________ 118 N. 1ST STREE X    IRC Building Description Form  New Gdrive/master files/building/apps, forms checklists BCM 1/13/14                              MASTER PERMIT#_______________________________             CHANGE ORDER #_______________________________             CHANGE ORDER #_______________________________  CHANGE ORDER #_______________________________  Building Description Form - IRC Property Location: Address: Unit #: Legal Description: (lot, Block) Owner: Owner Address: Parcel ID #: Building Code Information Code Editions: 2009 IRC 2009 IMC 2009 IPC 2009 IFGC 2009 IECC 2009 IFC 2011 NEC Fire Sprinkler System Installed: ______ NO _____ YES NFPA _____ Type of Construction: VB Required Special Inspections: ____High Strength Bolting ____Epoxy Anchors ____Structural Steel Welding ____Permanent Micropiles _____Other (specify): ______________________ Energy Code Compliance Path: ____Prescriptive Table ____ResCheck Performace ____ResCheck UA Tradeoff External Energy Use Snowmelt ______sq ft Existing ______sq ft New Spa _____ Pool ____ Building Description # Stories Above Grade _______ # Stories Below Grade ________ Garage: Attached______# Of Cars___ Detached______# Of Cars____ Carport_______ Bedrooms______ Full Baths_____3/4 Baths_____1/2 Baths_____ Kitchen_____ # Wood Fireplaces: _______ # Gas Appliances: _______ # Gas Logs:____________ Other Rooms: ____________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ACCESSORY DWELLING UNIT: Living______Kitchen_______Bath______Bedroom______Other:_________ Reviewed by Plans Examiner Date 118 N. 1ST STRETT LOT A, BLOCK 58 623 W. HOPKINS, ASPEN COLORADO 118 NORTH FIRST LLC 273512439001 X 0007.2017.ARBU 2 JH 4/11/17 13121 1 Dining/living room on main level ELEMENT ENVIRONMENTAL | Rothberg 10816 189 County Road 135 Glenwood Springs, CO 81601 (970) 274-3139 Final Clearance Letter For 118 N. 1st St. Aspen, CO 81611 January 30th, 2017 Prepared for Quetzal Environmental 4728 Ireland Ct. Aurora, CO Element Environmental Project Number Rothberg 101816 Prepared By: Joshua Johnson CDPHE Air Monitoring Specialist #18401 CDPHE Asbestos Consulting Firm #21640 ELEMENT ENVIRONMENTAL | Rothberg 10816 Element Environmental Date: 01/30/2017 189 County Rd. 135 Glenwood Springs, CO 81601 (970) 274-3139 josh@elementenv.co Client: Quetzal Environmental Dear Quetzal Environmental, I am pleased to offer you this report for work performed at the reference site. On January 30th, 2017 Mr. Joshua Johnson with Element Environmental performed final clearances at 118 N. 1st St. The final clearances consist of a visual inspection for dust and debris and ambient air sampling. The clearance consisted of 1 containment. This included all the interior portions of the house. The containment included all of the drywall on the Main level and Upstairs. The ACM 9x9 tiles in the living room were also removed. Mr. Joshua Johnson CDPHE AMS #18401 performed a visual inspection per the CDPHE guidelines and found no visible dirt or debris. After the visual inspection was complete air samples were taken of the work area. Five samples were taken from each of the work areas. The air samples were analyzed by PCM (Phase Contrast Microscopy) per the NIOSH 7400 method. All samples must below 0.01 f/cc in order to pass the air clearance. All samples were below the limit amount. Per Colorado Reg 8 Part B guidelines. The work area is now clear for occupancy or normal work to resume. Please note: Any suspect asbestos containing materials (ACM) remaining should be assumed to contain asbestos unless they are properly tested and analyzed by a CDPHE accredited inspector. All work performed MUST follow appropriate EPA, CDPHE, OSHA, and local government guidelines to protect the employees, occupants, and the environment. _______________________________________________ Joshua Johnson Air Monitoring Specialist# 18401 ELEMENT ENVIRONMENTAL | Rothberg 10816 ELEMENT ENVIRONMENTAL | Rothberg 10816 -------------------------------------------------------------------------------------------------------------------------------------------------------- Webpage: http://www.aspenpitkin.com/pdfs/depts/41/asbestosquestionnaire.pdf Rev. 02-10 City of Aspen - Asbestos Checklist Project Address: Parcel ID #: Asbestos is a known human carcinogen and is an airborne hazard. Once airborne, asbestos fibers can stay suspended in the air for days, weeks or even months before settling out of the air, only to become airborne again from some minor disturbance, such as turning on an air conditioner. Uncontrolled asbestos abatement projects or renovation projects that disturb asbestos may cause latent asbestos hazards that could expose people to asbestos in the future, long after the renovation activity occurred. The airborne asbestos fiber concentrations resulting from disturbances may result in a significant exposure to the current and future occupants of the home. The 1989 “Ban” on asbestos-containing materials is commonly misunderstood. In fact, in 1991 the U.S. Fifth Circuit Court of appeals vacated much of the so-called “Asbestos Ban and Phaseout Rule” and remanded it to the EPA. Thus, much of the original 1989 EPA ban on the U.S. manufacturing, importation, processing, or distribution in commerce of many asbestos-containing product categories was set aside and DID NOT TAKE EFFECT. Therefore, ALL demolition, remodel or renovation projects must determine if disturbed material above the trigger levels contains asbestos. 1. Residential : Will you be removing more than 32 sq ft, 50 linear feet (e.g., pipe insulation), or the volume equivalent of a 55-gallon drum of any material besides concrete, wood, bricks or steel – examples are drywall, linoleum, ceiling tiles, roofing materials, etc.? ___ NO ___ YES 2. Commercial ___ NO ___ YES : Will you be removing more than 160 sq ft, 260 linear feet (e.g., pipe insulation), or the volume equivalent of a 55-gallon drum of any material besides concrete, wood, bricks or steel – examples are drywall, linoleum, carpet, carpet adhesives, ceiling tiles, roofing materials, etc.? 3. Will you be completely demolishing the building? ___ NO ___ YES If the answer is YES to any of the above, you will need an asbestos test before you can apply for a building and/or demolition permit. A state certified asbestos inspector must do this test and the test report must be submitted with the building permit application. If the building has asbestos, a state certified asbestos abatement firm must remove it. After removal, the abatement firm must provide a letter to the Building Division stating that all the asbestos has been removed and that the air is clean. This letter must be received BEFORE a permit will be issued. (See the local or statewide Yellow Pages, DexOnLine, or http://www.cdphe.state.co.us/ap/asbestos/index.html for certified asbestos inspectors and abatement companies. ALWAYS ask for proof of current state certification.) If YES to question # 3, you must submit a demolition permit app with the CDPHE in addition to the Aspen permit app. This form may be found at http://www.cdphe.state.co.us/ap/asbestos/asdemo.pdf NOTE : A copy of this demolition permit app must be submitted with the initial building permit application. When the CDPHE approves the app, their issued permit must be given to the Aspen Building Dept before we issue our permit. I hereby certify that the above information is true and complete. Owner______________________________ Phone # Applicant (print name)_________________________________ Phone #____________ Applicant Signature ___________________________________ Date ______________ Please call the City of Aspen Environmental Health Department at 920-5039 at any time if you have questions about asbestos, interpreting your test results, or other matters. X 118 NORTH FIRST LLC 970-920-1280 RYAN DOREMUS 970-274-1421 01/25/17 G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over City of Aspen and Pitkin County FIREPLACE & WOODSTOVE REGISTRATION *Required—Contact Assessors offices at 920-5160 Registration will not be accepted without a Parcel Id number List all devices in your home (2 are allowed per building, except for gas appliances) Note: If the number, type and location on this registration form do not match what is show on your plans or what is actually installed, your permit or Certificate of Occupancy will be denied. Type of Building (circle one): Reside ntial Other Type of device Room Existing New Make & Model Wood burning fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Gas log fireplace (select one) ?Site-built masonry ?Factory built insert: model number: _____________________ Certified woodstove Gas fireplace appliance (attach spec sheet) If any devices are being removed, please describe here, i.e. “old woodstove removed from living room” · __________________________________________________________________________________ · __________________________________________________________________________________ · __________________________________________________________________________________ _______________________________________________________ ____________________________ Signature of applicant Date *Parcel Id number:____ ____ ____ ____ -- ____ ____ ____ -- ____ ____ -- ____ ____ ____ Street Address:_________________________________________________________________________ Owners Name:_________________________________________________________________________ 2 7 3 5 1 2 4 3 9 0 0 1 118 N. 1ST. STREET 118 NORTH FIRST LLC LIVING ROOM 1 WOOD BURNING FIREPLACE IN THE LIVING ROOM 01/25/2017 MONTIGO R420 X X LIVING ROOM G:\city\building_dept\Aspen 2004 Checklists\fireplace registration .doc over ASPEN/PITKIN COUNTY FIREPLACE AND WOODSTOVE REGULATIONS In order to keep our air as clean as possible, the elected officials of Aspen and Pitkin County have passed ordinances to regulate the number of fireplaces and woodstoves that can be installed in any building. Building permit applicants must file a fireplace/woodstove registration with the City of Aspen Building Department or the Pitkin County Building Department before the building permit is issued. Pitkin County is separated into 2 areas. One is the non attainment area, which includes the City of Aspen and the Metropolitan areas of the county, i.e. Mountain Valley, Red Mountain, Difficult Ca mpground, T Lazy 7 Ranch, and part of Starwood. The other is the attainment area which includes the less densely populated parts of the county, i.e. Brush Creek Village, Holland Hills and Old Snowmass. Decorative gas appliance: A device utilizing natural gas as a fuel gas designed to appear as a real fireplace with a 4 to 5 inch Class B vent or direct vent, fixed glass door and a firebox no deeper than 24 inches. Certified Woodstove: Colorado Phase III certified woodstove or a Phase II EPA certified woodstove. Gas log fireplace: Meet all codes for burning wood but are used with gas logs. They are not allowed in bedrooms. Aspen and Metropolitan Areas of Pitkin County in the non attainment area New buildings in the non attainment area may have either 2 gas log fireplace or 2 certified woodstoves or 1 each. They may also have an unlimited number of decorative gas appliances. Wood burning fireplaces cannot be installed, nor may coal be used as fuel. Remodeling or an addition to an existing home in the non attainment area · If the building has 2 or more fireplaces, gas log fireplaces or woodstoves, they only devices you can add are decorative gas appliances. · If the building has 1 fireplace, gas log fireplace or woodstove, you may add 1 gas log fireplace and an unlimited number of decorative gas appliances. · If a building has more than 2 fireplaces, gas log fireplaces; if one is affected by the remodel it must be removed. · If a building has only 1 or 2 fireplaces, woodstoves or gas log fireplaces, please keep in mind: o If you alter the firebox of a fireplace, it must be converted to gas logs or removed. o If a woodstove is moved, it must be removed or replaced with a department certified woodstove. Attainment Area in Pitkin County New residential buildings in this area may have one wood burning fireplace and one gas log or certified woodstove. If there is no fireplace, you may have either 2 gas log fireplaces or 2 certified woodstoves or 1 each. Buildings may also have an unlimited number of decorative gas appliances. Remodeling or an addition to an existing building in the attainment areas · If the building has 2 or more fireplaces or woodstoves, the only devices you can add are decorative gas appliances. · If you have 1 fireplace or woodstove, you may add 1 gas log or certified woodstove and an unlimited number of decorative gas appliances · If a building has more than 2 fireplaces or woodstoves: if one is affected by a remodel, it must be removed · If a building has on 1 or 2 fireplaces, woodstoves or gas log appliances, please keep in mind: o If a woodstove is moved, it must be removed or replaced with a department certified device. o If you alter the firebox of a fireplace, and already have another fireplace, it must be converted to gas log Non residential buildings (which include commercial buildings, restaurants, lodges, public buildings, and hotels) in the attainment area of Pitkin County are allowed to have gas appliances. R-Series Single Sided Residential ∙ Power Vent Linear Fireplace Available at: Printed in Canada P/N XB2200 042214 Ferndale, Washington TF 1.800.789.6236 FX 1.866.300.0927 Langley, British Columbia TF 1.800.378.3115 FX 1.604.607.6462 ® C US Consult the owner’s manual for complete installation instructions and proper clearances to combustible surfaces prior to installing fireplace. All specifications, framing dimensions, product designs, materials and colors are subject to change without notice. The actual flame pattern and color may vary slightly from the illustrations. Diagrams and illustrations are not to scale. Options & accessories may have associated surcharge. Warranty: The manufacturer warrants this fireplace to be free from defects in materials and workmanship at the time of manufacture. There is a limited 10 year warranty on the firebox; 5 year limited warranty on the burner and 1 year limited warranty on the pilot burner assembly and fan motors (if included). The valve carries a limited 1 year warranty unless otherwise specified in the installation manual. Glass, plated/painted finishes and refractory lining are exempt. Features: ❏ Frameless design allows for brick or tile installation over the fireplace ❏ R320/420 convertible 5"/8" Top or Rear Power vent ❏ R520/720/820 convertible 5"/10" Top or Rear Power vent ❏ Linear Contemporary burner with White, Silver, Opaque Firestones‡ ❏ Unique door design for easy access to firebox ❏ 100% fail-safe shut-off valve Options: ❏ Various Linear Contemporary burner accessories‡ ❏ Remote Control ❏ Safety Door Screen Fireplace BTU/H Input Model#Natural Gas Liquid Propane R-Series R320 50,000 40,000 R-Series R420 65,000 55,000 R-Series R520 80,000 65,000 R-Series R720 100,000 80,000 R-Series R820 100,000 80,000 Unit Dimensions A B C D E F G H I J K L M N R-Series R320 48¹¹/₁₆"38¹/₁₆"19¾"16⅛"37¼"24⁵/₁₆"9½"41⁹/₁₆"15³/₁₆"31¹⁵/₁₆"5"8"12⅜"5⅞" R-Series R420 60¹¹/₁₆"38¹/₁₆"19¾"16⅛"49¼"30⁵/₁₆"9½"53⁹/₁₆"15³/₁₆"31¹⁵/₁₆"5"8"12⅜"5⅞" R-Series R520 72¹¹/₁₆"39¹/₁₆"21¾”18⅛"61¼"36⁵/₁₆"9½"65⁹/₁₆"15³/₁₆"32¹⁵/₁₆"5"10"11⅜"5⅞" R-Series R720 96¹¹/₁₆"40¹/₁₆"21¾”18⅛"85⅛"48⁵/₁₆"9½"89⁹/₁₆"15³/₁₆"33¹⁵/₁₆"5"10"12⅜"5⅞" R-Series R820 108¹/₁₆40¹/₁₆"21¾”18⅛"97⅛"54⁵/₁₆"9½"101⁹/₁₆"15³/₁₆"33¹⁵/₁₆"5"10"12⅜"5⅞" ‡ Go to www.montigo.com for colour images R-Series R620 with Firestones shown on reverse R-Series with Decorative Rocks shown I JK L M N Side View AAA BCDE Front View F G H Top View Residential Design Standards Administrative Review Section 26.410.020.B. of the Land Use Code requires an Administrative Review for compliance with the Residential Design Standards (RDS) for all residential projects, unless otherwise exempted pursuant to Section 26.410.010.C. Exempt projects include: • An addition or remodel to an existing structure that does not change the exterior of the building • A remodel of a structure where the alterations proposed change the exterior of the building, but are not addressed by any of the RDS • A residential unit within a mixed-use building • A designated historic resource listed on the Aspen Inventory of Historic Landmark Sites and Structures. New buildings on a historic landmark lot are not exempt. All applicable residential projects shall submit for RDS Administrative Review or Alternative Compliance prior to building permit submittal. An applicant may choose to apply directly for a variation from the Planning & Zoning Commission or Historic Preservation Commission, pursuant to Chapter 26.410.020.C. A pre-application summary will be required for a variation request. Review Process: The Community Development Department staff shall review an application for applicability and compliance with Chapter 26.410, Residential Design Standards. If the application complies with all applicable standards as written, a signed Checklist and stamped plan set shall be provided to the applicant to be included with building permit submission. If the application does not comply with one or more applicable standards, an unsigned Checklist and redlined plan set shall be emailed to the applicant including comments from staff on which standard(s) the application does not comply with and a description of why the standard(s) is not compliant. The applicant shall be provided the opportunity to revise and resubmit the design in response to the comments. Staff will keep an application open for 30 days from the date an unsigned Checklist is emailed to the applicant. If after such time no revisions are submitted, the application will be removed from the review system. Pursuant to 26.410.020.C, projects that do not meet the criteria for Administrative Review or Alternative Compliance (as determined by staff) may be reviewed by the Planning & Zoning Commission, or HPC if appropriate, at the applicant’s request. A pre-application summary will be required for a variation request. Page 1 of 2 Application for RDS Administrative Review: An application for RDS Administrative Review that IS NOT requesting Alternative Compliance shall be submitted to the Community Development front desk on a USB drive or CD or emailed to justin.barker@cityofaspen.com. Applicants shall be notified of complete/incomplete application by email. An application for RDS Administrative Review shall include the following documents in digital format: • Proof of ownership (no older than 6 months from submittal date) • Representative authorization letter from owner • Vicinity map • Site improvement survey certified by a registered land surveyor (no older than one year from submittal date) • Site plan (scaled 24”x36”) • Floor plans (scaled 24”x36”) • Elevations (scaled 24”x36”) • Complete scope of work noting all areas affected by the proposed project • Complete RDS applicant checklist (attached) addressing how each standard is met with sheet references for each standard Application for RDS Alternative Compliance: An application for RDS Alternative Compliance will require a pre-application summary provided by Community Development staff, and shall be submitted as a Land Use Application. Required application submittal items shall be outlined in the pre-application summary. Page 2 of 2 Residential Design Standards Administrative Review Residential Design Standards Administrative Compliance Review Applicant Checklist Standard Complies Alternative Compliance N/A Sheet #(s)/Notes B.1.Articulation of Building Mass (Non-flexible) B.2.Building Orientation (Flexible) B.3.Build-to Requirement (Flexible) B.4.One Story Element (Flexible) C.1.Garage Access (Non-flexible) C.2.Garage Placement (Non-flexible) C.3.Garage Dimensions (Flexible) Instructions: Please fill out the checklist below, marking whether the proposed design complies with the applicable standard as written or is requesting Alternative Compliance (only permitted for Flexible standards). Also include the sheet #(s) demonstrating the applicable standard. If a standard does not apply, please mark N/A and include in the Notes section why it does not apply. If Alternative Compliance is requested for a Flexible standard, include in the Notes section how the proposed design meets the intent of the standard(s). Additional sheets/graphics may be attached. Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Address: Parcel ID: Zone District/PD: Representative: Email: Phone: Page 1 of 2 Standard Complies Alternative Compliance N/A Sheet #(s)/Notes C.4.Garage Door Design (Flexible) D.1.Entry Connection (Non-flexible) D.2.Door Height (Flexible) D.3.Entry Porch (Flexible) E.1.Principle Window (Flexible) E.2.Window Placement (Flexible) E.3.Nonorthogonal Window Limit (Flexible) E.4.Lightwell/Stairwell Location (Flexible) E.5.Materials (Flexible) Residential Design Standards Administrative Compliance Review Applicant Checklist Disclaimer: This application is only valid for the attached design. If any element of the design subject to Residential Design Standards changes prior to or during building permit review, the applicant shall be required to apply for a new Administrative Compliance Review. Page 2 of 2 Rothberg Development Construction Management Plan 118 N 1st St Aspen, CO 81611 1.0 Total square footage of disturbance shall be 2176 on the existing land. Total interior remodel shall consist of 2176 square feet of interior space as per architect. 2.0 Project Introduction: 626 Francis St remodel. 2.1 Total project disturbance area shall be 2176, the project is interior remodel of a historic building. 2.2 Project vicinity map is located on architectural drawing G 0.00 2.3 Home was built in 1888. The lot square footage is 3000 and the home square footage is 2176. The proposed remodel shall include: asbestos mitigation, removal of existing flooring and all interior cabinets and fixtures. Pouring footers for new interior structure for new floor build. New lighting, fixtures, cabinet, dry wall, and all finishes for interior. Nothing will be done on the exterior and as per Aspen Historical Society requirements, all windows and siding shall remain. No sewer or storm water shall be affected. No city water shall be affected. 3.0 Project Documentation 3.1 No current permits for this property exist. Rothberg Development shall maintain insurance and proper licensure throughout the project 3.2 A project sign including a date table notifying neighbors as to construction progress shall be maintained on site 3.3 Sign shall be posted on site 3.4 Contact list: Owner: 118 N. 1st st LLC. Mark Friedland 920-1280 Contractor: Rothberg Development, Adam Rothberg 948-0480 Site Supervisor: Adam Rothberg 948-0480 Safety Officer: Adam Rothberg Traffic Officer: no traffic officer shall be required Erosion Control Rep. Project is interior remodel 4.0 Project Implementation 4.1 Dates of Construction: Project shall begin upon permitting and shall take approximately 10 months 4.2 Hours of construction: 8 am to 5 pm Monday thru Friday and 9 am to 5 pm on Saturday. 4.3 Project shall commence with removal of all asbestos under asbestos removal permit, then all removal of kitchen fixtures, bathroom tile floors, and bathroom fixtures, all cabinetry and some lighting fixtures. Upon completion of demo, all items listed above shall be replaced with new items. Property shall not be fenced unless required by the Aspen Building department. No outdoor work shall be performed as per requirements on an Aspen historical structure. 4.4 6’ fencing exists and no additional fencing shall be utilized 4.5 No trees shall be removed or affected. 4.6 No permit shall be required from Parks Dept. 5.0 Site Management: 5.1 Right of Way Management Plan is submitted with this CMP and detailed on a full size survey. 5.2 Emergency access shall not be impeded in any way. 5.3 This project shall be under the category of Minor impact. Rothberg Development utilizes it owns crew that carpools from Glenwood and arrives in two crew cab trucks that carry equipment and workers. In addition, a dump trailer shall be used to remove cabinets and fixtures from the site 5.4. No office trailer shall be utilized on site. Materials shall be stored inside . A dump trailer shall be used only when necessary and will not remain onsite full time. Waste management: All materials removed from site shall be separated into wood, plastic, stone, and re-usable piles. Any items that are reusable shall be loaded into a trailer and stored for future use off-site. Any items that may be sold shall be sold. If items cannot be sold then they will be recycled accordingly. Rothberg Development shall utilize a trailer for recycling separately from garbage and non-recyclables. 6.0 Traffic Control: Main St to 1st st. to Property. From Property to Bleeker to 2nd St to Main St. 6.2 Trucks and trailers, and material delivery trucks such as Probuild flat bed trucks will be the largest trucks that will arrive onsite. Probuild’s largest truck would be the largest truck onsite at 28 feet and 18,000 lbs dry weight. Maximum 33,000 lbs fully loaded. 6.3 Specified above 6.4 No more than 1 delivery per day shall occur and most days there shall be no deliveries. Deliveries shall only occur during working hours. No semi-trucks shall be required, only flat beds. No delivery truck shall idle for more than 5 minutes. 6.5 Site is not in the central core and remodel shall require only minimal parking and deliveries. No traffic shall be impeded. 7.0 Pedestrian traffic shall not be impeded in any way 8.0 Sediment and Erosion Control - Not applicable to interior remodel and exterior material replacement. 9.0 Fugitive Dust Control. No site work shall be done. No fugitive dust emissions will occur. 10.0 Emissions: All vehicles will maintain proper emission control as per state and city requirements 11.0 Contractor has signed Construction Noise Suppression Plan simultaneous with permit submission and will adhere to it. 6/29/2014 Page 1 of 2 ASPEN BUILDING PERMIT APPLICATION CHECKLIST IRC: Single Family, Duplex & Townhome For Building and Permit Information, please refer to our website at: www.aspenpitkin.com JOB ADDRESS___________________________________ PARCEL I.D. NUMBER________________ OWNER__________________________________________________________ DATE_____________ The following are requirements for various types of projects. Permits must include ALL of the items on this checklist or they will not be accepted. Incomplete permits will be turned away. Refer to the Single Family & Duplex Building Submittal Guide and guides from other referral departments for clarifications and descriptions on each item. □ Be prepared to pay submittal fees at permit submittal. Contact a permit coordinator for a fee estimate. □ Submit a flash drive or disc with a copy of all documents and drawings in pdf format. 8 ½” x 11” Documents (see submittal guide for number of copies) Submittal Requirements New Construction Addition Alteration/ Remodel Interior only Alteration Demo partial or complete Repair Planning Approvals √ □ √ □ √ □ √ □ √ □ √ □ Permit Application Form & Contact Sheet √ □ √ □ √ □ √ □ √ □ √ □ Valuation Adjustment Affidavit & Construction Bid √ □ √ □ √ □ √ □ HOA Certification √ □ √ □ √ □ √ □ √ □ √ □ IRC Building Description Form √ □ √ □ √ □ √ □ √ □ Asbestos Questionnaire √ □ √ □ √ □ √ □ √ □ Asbestos test and clearance reports √ □ √ □ √ □ √ □ √ □ State Asbestos Demolition Approval Notice √ □ Fireplace Registration Form & Manufacturer’s installation instructions √ □ √ □ √ □ √ □ Energy Code Compliance √ □ √ □ √ □ √ □ Non-Vented Roof Assembly Calcs √ □ √ □ √ □ √ □ U-Factor Fenestration Docs √ □ √ □ √ □ PERMIT#:___________________ 118 N. 1ST STREET 273512439001 118 NORTH FIRST LLC 1/25/2017 N/A N/A N/A X X X X X X IN PROGRESS IN PROGRESS N/A 6/29/2014 Page 2 of 2 Submittal Requirements New Construction Addition Alteration/ Remodel Interior only Alteration Demo partial or complete Repair RREMP documents √ □ √ □ √ □ Line Grade Verification Form √ □ √ □ Verification of Structural Integrity √ □ √ □ √ □ √ □ Soils Report √ □ √ □ Smuggler Superfund Soil Removal Permit √ □ √ □ √ □ Signed Special Inspection and Testing Agreement √ □ √ □ √ □ √ □ √ □ Mechanical Docs √ □ √ □ √ □ √ □ Photos √ □ √ □ √ □ √ □ Unit/Building relationship √ □ √ □ √ □ √ □ √ □ 24”x36” (2 COPIES) & 11”x17” (1 COPY) Plans Sheets must be in the following order. Existing plans required for all additions & alterations Submittal Requirements New Construction Addition Alteration/ Remodel Interior only Alteration Demo partial or complete Repair Cover Sheet √ □ √ □ √ □ √ □ Survey √ □ √ □ √ □ Excavation/ Earth Retention Plans √ □ √ □ Site Plan √ □ √ □ √ □ √ □ √ □ RREMP Plan √ □ √ □ √ □ √ □ Area Sheet √ □ √ □ √ □ √ □ Floor Plans √ □ √ □ √ □ √ □ √ □ √ □ Roof Plan √ □ √ □ √ □ Elevations √ □ √ □ √ □ √ □ Sections √ □ √ □ √ □ √ □ Details √ □ √ □ √ □ √ □ √ □ Fireplace Details √ □ √ □ √ □ √ □ Schedules √ □ √ □ √ □ √ □ Reflected Ceiling Plans √ □ √ □ √ □ √ □ Lighting Plans √ □ √ □ √ □ √ □ Mechanical Plans √ □ Structural Plans √ □ √ □ √ □ √ □ √ □ Radon Plan √ □ √ □ N/A N/A N/A N/A N/A X N/A X N/A N/A X X X X X N/A N/A N/A N/A N/A N/A N/A