Thermal Efficiency
lochinvar.com
HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS
OPERATING CONTROL FEATURING
A BUILT-IN CASCADING SEQUENCER
5 MODELS: 399,000 – 800,000 BTU/HR
FIRING RATE MODULATION TO 5:1
LESS THAN 30 ppm NOx
DIRECT-VENT FLEXIBILITY TO 100 FEET
The KNIGHT® XL, engineered with Lochinvar’s exclusive SMART SYSTEM™ control and an
array of other innovative features, places it far ahead of any commercial heating boiler
in its class. It promises and delivers ultimate ease of installation and maintenance. With
up to 94.6% thermal efficiency, low-NOx emissions and a fully modulating burner, it is
the best “green choice” for today’s environmentally focused market.
Five modulating/condensing stainless steel KNIGHT XL boilers are available, with
399,000–800,000 Btu/hr inputs, with remarkably small space-saving footprints. All are
equipped for direct-vent installation with air intake and exhaust runs up to 100 feet using
PVC or AL29-4C venting materials. This range of choices is ideal for light-duty applications
such as small hotels, schools and office buildings. For higher-demand applications, up
to eight KNIGHT XL units can be installed utilizing the built-in cascading sequencer to
deliver up to 6.4 million Btu/hr heating capacity.
THE KNIGHT XL BOILER reflects Lochinvar’s constant commitment to providing all the
options you need to serve every application.
The Knight XL Combustion System
Advanced Negative Regulation Technology
KNIGHT XL safely and reliably operates with supply gas pressure as low as 4 inches water column, as Negative
Regulation (Neg/Reg) technology automatically adjusts fan speed that ensures the correct volume and mix of
fuel and air throughout the firing range.
“Fail-Safe” Direct-Spark Ignition
With each call for heat, two electrodes ignite the fuel/gas mixture. A third
electrode then senses for flame. SMART SYSTEM will lock out and display
the fault if ignition does not occur.
Two-in-One Stainless Steel Heat
Exchanger
A combined primary and secondary heat exchanger captures flue gas heat
and allows entering water temperatures as low as 50°F without a low-temperature
bypass. The stainless steel, pH-tolerant design features a weld-sealed assembly with no
O-rings or gaskets, and does not require special glycol. ASME Section IV approved and stamped.
Fully Modulating Burner
The SMART SYSTEM allows fully modulating combustion with 5:1 turndown. The burner can fire as
low as 20% of maximum input, and modulates the firing rate up to 100% as demand increases.
The burner is a single stainless steel assembly covered with woven steel mesh, and fires in a 360°
pattern along the entire length of the primary heat exchanger. This allows the compact KNIGHT
XL to exceed the capacity of units with larger multiple burners.
The Smartest Choice for Condensing Boiler Performance
The Brain That Drives
Brilliant Performance!
SMART SYSTEM provides unequalled control
and monitoring functions that are easy to
understand and use.
2-Line, 16-Character LCD Display
Setup and diagnostic information in words, not codes
Password Security
Dual password levels for installer and user
Building Management System Control (0 – 10 V)
BMS-driven input for control of modulation rate or temperature
PC Connection
Can be used with KNIGHT XL PC or Pocket PC software to program
and troubleshoot SMART SYSTEM functions, and to track historical
data, including faults, trends and energy consumption
Outdoor Reset
Outdoor temperature monitor guides the reset schedule to meet
heat loss/load of the building
Night Setback
Program a setback for any time of the day, each day of the week
System Pump and Boiler Pump Controls
Provides power to both system and boiler pumps on a call for
heat. Programmable pump delay orders pumps to operate after a
call has been satisfied
Pump Relay with Freeze Protection
Ensures water temperature does not fall below 40°F
Hot Water Generator Compatibility
One boiler in a sequence can be assigned for Domestic Hot Water
Prioritization (DHWP) to meet domestic water demand
Inlet/Outlet Temperature Sensors and Display
Installer can select which sensor controls the setpoint
Low Water Flow Indicator
Protects against high temperature differential in the heat
exchanger with reduced firing rate or shutdown
Product Service Indicator
Program reminders for cycle count, operation hours or last service
Field Connection Versatility
User-friendly terminal strip allows for 28 low-voltage field
connections. Plus 4 line voltage connections supply power to
the unit, and up to 3 pumps operated by the SMART SYSTEM
15-1/2"
zero clearance
to combustibles
The 4-unit installation shown illustrates
the space-saving KNIGHT XL footprint,
and the ease and versatility of the
two-pipe direct-vent design.
Easy Handling
on the Jobsite
Because of its compact design and stainless steel heat
exchanger, KNIGHT XL boilers are remarkably lightweight
and easy to handle on the jobsite.
Direct-Venting
up to 100 Feet Easy
KNIGHT XL offers tremendous flexibility for placement of
units within the building, because it permits direct-vent
air intake and exhaust runs up to 100 equivalent feet
using either PVC or AL29-4C stainless steel vent pipe.
Intake and exhaust runs can terminate horizontally
through a sidewall or vertically through the roof.
Access to
Internal Components
The front and top panels of the KNIGHT XL boiler can be
quickly removed without any tools. This provides fast,
easy access to internal components and electrical
connections during installation and service.
In commercial buildings requiring a multiple boiler system, modulating
operation of individual units should be sequenced so that the system
functions as an integrated whole.
SMART SYSTEM includes a built-in cascading sequencer for up to 8
KNIGHT XL units. This eliminates the initial cost and labor required
with installation of a separate sequencer. And, because it’s engineered
specifically for Lochinvar boilers, it removes any uncertainty about
using a “third-party” sequencer, to ensure precise, dependable
cascading operation.
When utilizing the built-in cascading sequencer, KNIGHT XL boilers
communicate through a simple 2-wire daisy chain connection. On
demand, one boiler in the system functions as the lead unit, and
modulates with demand to capacity. The additional load then
“cascades” to the second boiler, which fires and modulates to meet
added demand.
Cascading continues as additional boilers fire in sequence, until all
units are in operation or demand is satisfied. When demand drops,
the cascading process reverses, with the precision, control and
performance you expect from Lochinvar.
SMART SYSTEM also controls Lead-Lag Rotation. Every 24 hours the
lead boiler role is shifted to the next unit in the sequence. This rotation
ensures long life by distributing “lead-lag” runtimes equally over each
unit in the system.
Including
a Built-in
Cascading
Sequencer!
Smart System Features
> 2 LINE, 16-CHARACTER LCD DISPLAY
> PASSWORD SECURITY
> BUILT-IN CASCADING SEQUENCER
> BUILDING MANAGEMENT SYSTEM CONTROL
> 0-10 VDC INPUT CONTROL
> OUTDOOR RESET
> NIGHT SETBACK
> MULTIPLE PUMP CONTROL
(SYSTEM, BOILER & DHW)
> PUMP RELAY WITH FREEZE PROTECTION
> PRODUCT SERVICE INDICATOR
> FIELD CONNECTION VERSATILITY
> OPTIONAL PC OR POCKET PC SOFTWARE
Patent Pending
Standard Features
> Up to 94.6% Thermal Efficiency
> Modulating Burner with 5:1 Turndown
> ASME Stainless Steel Heat Exchanger
> Direct-Vent Sealed Combustion
> PVC or AL29-4C Venting up to 100 Feet
> SMART SYSTEM Digital Operating Control
> 50 psi Relief Valve
> Adjustable High Limit w/ Manual Reset
> Flow Switch
> Temperature & Pressure Gauge
> Direct-Spark Ignition
> Low NOx Operation
> Low Gas Pressure Operation
> Zero Clearances to Combustibles
> Easy Access Terminal Strip
> Natural to LP Conversion Kit
> Inlet & Outlet Temperature Sensors
> Low Water Flow Indication
> Domestic Hot Water Prioritization
> Adjustable Leveling Legs
> Sidewall Vent Terminals
> On/Off Switch
> Contact on Any Failure
> 10 Year Limited Warranty
(See Warranty for Details)
Optional Equipment
> Alarm Bell on Any Failure
> Condensate Neutralization Kit
> High & Low Gas Pressure Switches w/ Manual
Reset (KB500-KB800)
> Outdoor Air Reset Sensor
> Low Water Cutoff w/Manual Reset & Test
> SMART SYSTEM PC Software
> Stainless Steel Vent Kits
Firing Codes
M9 Standard Construction
M7 California Code
M13 CSD1/FM/GE Gap (KB500-KB800)
KBX-01 1/08-Printed in U.S.A.
300 Maddox Simpson Parkway, Lebanon, TN 37090 | 615-889-8900 | fax: 615-547-1000 | www.lochinvar.com
Knight ® XL Boiler Dimensions and Specifications
Model Number Guide
KB N 700 M13
Model
F
i
r
i
ng Con
t
ro
lsNatu
ra
l
GasBtu/h
r
Inpu
t
Input Thermal NET
Model Min Max Efficiency Output I=B=R
Number MBH MBH % MBH MBH
KBN399 80 399 93.3 372 324
KBN500 100 500 93.3 467 406
KBN600 120 600 94.6 567 493
KBN700 140 700 94.3 660 574
KBN800 160 800 94.0 752 654
A B C D E F G H I J K Gas Water Air Vent Shipping
Conn. Conn. Inlet Size Wt. (lbs.)
42-1/2" 15-1/2" 27" 3-3/4" 21" 20-3/4" 14" 34" 34" 2" 18-3/4" 1" 1-1/2" 4" 4" 285
42-1/2" 15-1/2" 31-1/4" 3-3/4" 21" 25" 14" 35" 35" 2" 22" 1" 1-1/2" 4" 4" 305
42-1/2" 15-1/2" 36-1/4" 3-3/4" 21" 25" 14" 36" 32-3/4" 5-1/2" 19-1/2" 1-1/2" 2" 4" 4" 355
42-1/2" 15-1/2" 40-1/4" 3" 23" 29" 17" 36" 32-3/4" 3-1/4" 23-1/2" 1-1/2" 2" 4" 6" 395
42-1/2" 15-1/2" 45-1/4" 3" 23" 33-1/4" 17" 36" 32-3/4" 3-1/4" 27-3/4" 1-1/2" 2" 4" 6" 440
Notes: Change ‘N’ to ‘L’ for L.P. Gas Model. No deration on L.P. models. Performance data based on manufacturer test results. 120 VAC /15 AMP circuit required.
All dimensions shown in inches.
Knight XL Heating Boiler Dimensions and Specifications
Knight XL Boiler,
Natural Gas,
700,000 Btu/hr input,
M13 firing controls
LEFT SIDE
FRONT
BACK
8"
39-1/2"
13-3/4"
18-3/4"
H
K
D
G
F
E
C
9"
A
1-1/4"1/4" -
ADJUSTABLE
AIR INLET
FLUE
LOW VOLTAGE
ELECTRICAL
CONNECTIONS
GAS
INLET OUTLET
HEAT
EXCHANGER
DRAIN
3/4" NPT
CONDENSATE
DRAIN
FLUE
B
I
J
HIGH VOLTAGE
ELECTRICAL
CONNECTIONS
38-3/4"
3-1/2"