Loading...
HomeMy WebLinkAboutFile Documents.1350 Mountain View Dr.0027.2019 (3).ARBKEX EX EX EX EX EX EX EX EX EX EX EX EX EX EXEX PP 16' PH 12' PP 16' AF 3" EX SHR EX SHR EX SHR EXEXSP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 SP #10 VT #10 VT #10 VT #10 VT #10 VT #10 VT #10 VT #10 VT #10 VT #10 VT #10 PH 12' PH 12' VT #10 VT #10 VT #10 A W L S S 35 35 35 35 35 35 35 35 35 35 35 S 35 35 35 35 16 1" A3 15 1" A2 10 1" A1 dr .75" A8 16 1" A7 18 1" A9 dr .75" A5 1 .75" A4 dr .75" A12 17 1" A13 dr .75" A15 14 1" A14 14 1" A16 10 1" A17 1 .75" A18 11 1" A11 (1)2'' (2)2'' (1)2''(2)2'' (1)2'' (2)2'' (1)2'' 3 A (1)2'' 1'' dr .75" A19 (1)2''--1'' 1'' 35 35 35 35 35 dr .75" A10 dr .75" A6 (1)2'' (1)2'' FS 11 4'' REFER TO SHEET L8.00 IRRIGATION NOTES & SCHEDULE L8.10 IRRIGATION PLANS L8.20-L8.40 IRRIGATION DETAILS L8.40 IRRIGATION CHART R CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU DIG, GRADE, OR EXCAVATE FOR THE MARKING OF UNDERGROUND MEMBER UTILITIES. Know what's below. Call before you dig. 0 NORTH SCALE: 1''=10' 5'10'20' POINT OF CONNECTION #1 - 1" PEAK FLOW REQUIREMENT: 18 GPM. REQUIRED STATIC PRESSURE: 75 PSI MIN. CONTRACTOR TO LOCATE 1 14" HARD COPPER PIPE STUBBED OUT AT THIS APPROXIMATE LOCATION ( 114" COPPER LINE & BACKFLOW IN HOUSE - BY OTHERS). INSTALL ONE MANUAL DRAIN VALVE, ONE 1" FLOW SENSOR, ONE 1" MASTER VALVE, ONE 1'' LOCKABLE BALL VALVE, ONE QUICK COUPLER VALVE AND EXTEND PVC MAINLINE AS SHOWN. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14# WIRE (TWO ORANGE AND TWO BLUE) AND CONNECT 2 OF THE WIRES FROM THE MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. SEE DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR. FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. CONTROLLER LOCATION "A" WALL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION COUNT), AT INDICATED LOCATION. 120 VOLT POWER IS AVAILABLE WITHIN 40 LF. OF CONTROLLER LOCATION FROM RESIDENTIAL POWER. ELECTRICAL METER, WIRE/CONDUIT, STEP-DOWN TRANSFORMER (IF REQUIRED) AND POWER CONNECTION TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES. EXTEND PE89 SHIELDED CABLE FROM THE FLOW SENSOR AND 4 #14 UFUL WIRES (TWO BLUE AND TWO ORANGE) FROM MASTER VALVE TO ASSOCIATED CONTROLLER. CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS. FEES AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY CONTRACTOR. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. MOUNT ONE WEATHER SENSOR ON FENCE WHERE THERE IS 20 FT. OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE. FINAL WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER PRIOR TO INSTALLATION. 1A 1 A NOTE: ALL IRRIGATION HEADS TO BE INSTALLED 3" OFF HARDSCAPE, PER DETAILS. Easement Property Line EasementEasement LITTLE LEAF LLC1350 MOUNTAIN VIEW DRIVE | ASPEN, CO 81611Title Drawing No. (Reserved: COA Stamp) Issuance PERMIT SETCheck Set Building Permit 2017-11-03 2017-11-15 2018-12-03 Change Order L8.10 Irrigation Plan Easement HydroSystems-KDI, Inc.860 Tabor Street, Suite 200Lakewood, Colorado 80401303-980-5327303-980-5384 (fax)Irrigation ConsultingBY OTHERS BY OTHERS Manual Drain Added Head Quick Coupler and Extra Wires Manual Drain AS BUILTS PREPARED BY KAEGEBEIN FINE HOMEBUILDING AND PREMIER LANDWORKS INC KFH CONTACT: CHARLIE BERGER