HomeMy WebLinkAboutFile Documents.1350 Mountain View Dr.0027.2019 (3).ARBKEX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EX
EXEX
PP
16'
PH
12'
PP
16'
AF
3"
EX SHR
EX SHR
EX SHR
EXEXSP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
SP
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
VT
#10
PH
12'
PH
12'
VT
#10
VT
#10
VT
#10
A
W
L
S
S
35
35
35
35
35
35
35
35
35
35
35
S
35
35
35
35
16 1"
A3
15 1"
A2
10 1"
A1
dr .75"
A8
16 1"
A7
18 1"
A9
dr .75"
A5 1 .75"
A4
dr .75"
A12
17 1"
A13
dr .75"
A15
14 1"
A14
14 1"
A16
10 1"
A17
1 .75"
A18
11 1"
A11
(1)2''
(2)2''
(1)2''(2)2''
(1)2''
(2)2''
(1)2''
3 A
(1)2''
1''
dr .75"
A19
(1)2''--1''
1''
35
35
35
35
35
dr .75"
A10
dr .75"
A6
(1)2''
(1)2''
FS
11 4''
REFER TO SHEET
L8.00 IRRIGATION NOTES & SCHEDULE
L8.10 IRRIGATION PLANS
L8.20-L8.40 IRRIGATION DETAILS
L8.40 IRRIGATION CHART
R
CALL 3 BUSINESS DAYS IN ADVANCE BEFORE YOU
DIG, GRADE, OR EXCAVATE FOR THE MARKING OF
UNDERGROUND MEMBER UTILITIES.
Know what's below.
Call before you dig.
0
NORTH SCALE: 1''=10'
5'10'20'
POINT OF CONNECTION #1 - 1"
PEAK FLOW REQUIREMENT: 18 GPM. REQUIRED STATIC PRESSURE: 75 PSI MIN.
CONTRACTOR TO LOCATE 1 14" HARD COPPER PIPE STUBBED OUT AT THIS
APPROXIMATE LOCATION ( 114" COPPER LINE & BACKFLOW IN HOUSE - BY OTHERS).
INSTALL ONE MANUAL DRAIN VALVE, ONE 1" FLOW SENSOR, ONE 1" MASTER VALVE,
ONE 1'' LOCKABLE BALL VALVE, ONE QUICK COUPLER VALVE AND EXTEND PVC
MAINLINE AS SHOWN. EXTEND ONE PE89 SHIELDED CABLE FROM FLOW SENSOR TO
DATA RETRIEVAL UNIT LOCATED IN ASSOCIATED CONTROLLER. EXTEND 4 UFUL14#
WIRE (TWO ORANGE AND TWO BLUE) AND CONNECT 2 OF THE WIRES FROM THE
MASTER VALVE TO THE DATA RETRIEVAL BOARD IN ASSOCIATED CONTROLLER. SEE
DETAIL SHEET FOR REQUIRED PIPE LENGTHS UPSTREAM AND DOWNSTREAM OF FLOW
SENSING UNIT. WORK SHALL CONFORM TO LOCAL CODE. FEES AND PERMITS
ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID FOR BY CONTRACTOR.
FINAL BACKFLOW PREVENTER LOCATION SHALL BE APPROVED BY OWNER PRIOR
TO INSTALLATION.
CONTROLLER LOCATION "A"
WALL MOUNT ONE CONTROLLER (REFER TO SCHEDULE FOR MODEL & STATION
COUNT), AT INDICATED LOCATION. 120 VOLT POWER IS AVAILABLE WITHIN 40 LF. OF
CONTROLLER LOCATION FROM RESIDENTIAL POWER. ELECTRICAL METER,
WIRE/CONDUIT, STEP-DOWN TRANSFORMER (IF REQUIRED) AND POWER CONNECTION
TO CONTROLLER IS BY CONTRACTOR WITH WORK CONFORMING TO LOCAL CODES.
EXTEND PE89 SHIELDED CABLE FROM THE FLOW SENSOR AND 4 #14 UFUL WIRES
(TWO BLUE AND TWO ORANGE) FROM MASTER VALVE TO ASSOCIATED
CONTROLLER. CONNECT WIRES TO THE APPROPRIATE SENSOR INPUT PORTS. FEES
AND PERMITS ASSOCIATED WITH WORK ARE TO BE OBTAINED AND PAID BY
CONTRACTOR. FINAL CONTROLLER LOCATION SHALL BE APPROVED BY OWNER
PRIOR TO INSTALLATION. MOUNT ONE WEATHER SENSOR ON FENCE WHERE THERE IS
20 FT. OF CLEARANCE FROM ANY OVERHANG OR OBSTRUCTING FEATURE. FINAL
WEATHER SENSOR LOCATION SHALL BE APPROVED BY OWNER PRIOR TO
INSTALLATION.
1A
1
A
NOTE: ALL IRRIGATION HEADS TO BE
INSTALLED 3" OFF HARDSCAPE, PER
DETAILS.
Easement
Property Line
EasementEasement LITTLE LEAF LLC1350 MOUNTAIN VIEW DRIVE | ASPEN, CO 81611Title
Drawing No.
(Reserved: COA Stamp)
Issuance PERMIT SETCheck Set
Building Permit
2017-11-03
2017-11-15
2018-12-03 Change Order
L8.10
Irrigation Plan
Easement
HydroSystems-KDI, Inc.860 Tabor Street, Suite 200Lakewood, Colorado 80401303-980-5327303-980-5384 (fax)Irrigation ConsultingBY OTHERS
BY OTHERS
Manual Drain
Added Head
Quick Coupler and
Extra Wires
Manual Drain
AS BUILTS PREPARED BY
KAEGEBEIN FINE HOMEBUILDING
AND PREMIER LANDWORKS INC
KFH CONTACT:
CHARLIE BERGER