HomeMy WebLinkAboutFile Documents.1300 Red Butte Dr.0272.2018 (12).ARBKWELS Markup#1 1300 red Butte
Page: [1] IR-1300 Red Butte Road-IR.01
Author: rickma
Date: 1/10/2019 11:03:07 AM
File Name: WELS - Permit 1300 Red Butte Road
10.30.2018.pdf
WELS Section 6.1.3 requires a lockable master shutoff valve.
[1] IR-1300 Red Butte Road-IR.01 (4)
Page: [1] IR-1300 Red Butte Road-IR.01
Author: rickma
Date: 1/11/2019 9:05:12 AM
File Name: WELS - Permit 1300 Red Butte Road
10.30.2018.pdf
Please indicate irrigation valves associated with each hydrozone, for example:
Low (A1,A4,A3, etc) etc.
Page: [1] IR-1300 Red Butte Road-IR.01
Author: rickma
Date: 1/11/2019 8:53:24 AM
File Name: WELS - Permit 1300 Red Butte Road
10.30.2018.pdf
There are a number of trees called out in the legend of the landscape plans that are not on drip irrigation valves. WELS Section
5.2.7 suggests that trees be on separate valves from shrubs, ground covers and grass. Please revise plans in all instances.
Page: [1] IR-1300 Red Butte Road-IR.01
Author: rickma
Date: 1/11/2019 9:19:33 AM
File Name: WELS - Permit 1300 Red Butte Road
10.30.2018.pdf
Consider adding a few more perennial forb species in seed mix to increase bio-diversity in the landscape
30
40
A1
9.48
0.27
1"
F
A
M
M
C
C
B
M
C
M
WELS Section 6.1.3
requires a lockable
master shutoff valve.
Plant Water Use Type(s)Plant Factor Irrigation Method Irrigation Efficiency
Low 0.40 Overhead 75%
Medium 0.65 Drip 90%
Medium 0.65 Drip 90%
ATER NEED - ALL ZONES* - In gallons/sq. ft./season
s than the Maximum Applied Water Budget of 7.5 gallons/sq.ft./season.
0 Sq. Ft.
0 Sq. Ft.
Please indicate irrigation valves associated
with each hydrozone, for example:
Low (A1,A4,A3, etc) etc.
CONTROLLER120 VAC POWER REQUIRED
POCSIZE: 3/4-INCHPRESSURE: 80 PSIFLOW: 12 GPM
30
30 40
40 30
40
A19.48
0.271"
A26.40
2.401"
A310.9
0.281"
A49.29
0.301"
A5Drip
PER.1"
A64.50
2.401"F
A
2
1
B
B
B
K
K
M
MM
M
M
M
K K
K
M
C M
K
C
C
C B
B
A
A
M
M
O
M
M
M
M
M
M
MM
L
M
CMM
M
C
CMM
M
POP-U PRESS FLOW
LM O
POP-U PRESS FLOW
RGK
POP-U PRESS
YB A
IRRIGATION LEGEND
POINT-OF-CONNECTION ASSEMBLYPOINT-OF-CONNECTION ASSEMBLY
LATERAL PIPE TO SPRINKLERS:1-INCH SIZE UNLESS OTHERWISE INDICATEDCLASS 200 PVC
MAINLINE PIPE:1 1/4-INCH SIZE UNLESS OTHERWISE INDICATEDCLASS 200 PVC
LATERAL PIPE TO INLINE TREE DRIP RINGS:CLASS 200 PVC
SLEEVES:CLASS 200 PVC
There are a number of treescalled out in the legend of thelandscape plans that are not ondrip irrigation valves. WELSSection 5.2.7 suggests that trees be on separate valves fromshrubs, ground covers andgrass. Please revise plans in allinstances.
Consider adding a few more
perennial forb species in seed mix to
increase bio-diversity in the
landscape