Loading...
HomeMy WebLinkAboutFile Documents.1250 Snowbunny Ln.0040.2018 (15).ARBKBY REVISIONS DATE Drawn: Title: Drawing No.: A.6.014/25/2019Plotted On:DETAILS D:\archicad project folder\Doug Rager - Architect Archicad\Altfeld Residence\_Altfeld Residence Photorealistic 1-27-19.plnIF THE ABOVE DIMENSION DOES NOT MEASURE ONE INCH (1") EXACTLY, THIS DRAWING WILL HAVE BEEN ENLARGED OR REDUCED, AFFECTING ALL LABELED SCALES. 1" ACTUAL 10:55 AM1250 SNOWBUNNY LANE, TWO HARES UNIT AASPEN, COLORADOALTFELD RESIDENCEDOUG RAGER - ARCHITECT P.C.1780 Snowmass Creek Rd.Snowmass, Co. 81654(970) 927-1780 TEL/FAXJ.M unvented roof calc HARDY BOARD SIDING COLOR AND STYLE TO BE SELECTED energyshield continuous wall insulation r5 install per manuf. specs over existing sheathing EXISTING 1/2" SHEATHING & HOUSEWRAP NEW 2x10 RAFTERS REFER TO STRUCTURAL DRAWINGS FOR SPACING AND ATTACHMENT DETAILS sprayfoam entire cavity r64/ Part of continuous insulation system and air sealing NEW CLASS A METAL ROOF w versashield fire-resistant roof deck protection "drexelMetals dmc 150ss Profile" with "metshield high temp underlayment over w.r. Grace ice and water shield. See cutsheets provided as additional information metal flashing at grade 12" 1/4" rafters REFER TO STRUCTURAL DRAWINGS for sizing WITH 6" closed cell SPRAYFOAM INSULATION r36 AND R19 BATTS total r55 new roof assembly @ living room existing floor assembly no change existing floor assembly no change existing exterior wall framing exterior window and door casing detail zip r-sheathing continuous r6 insulation system install per manuf. specs existing exterior wall with 1/2" sheathing interior details and finishes to remain new hardy board siding exterior trim new windows ADD SNOW FENCE AT NEW ROOFS PLUS EXISTING ROOFS THAT DRAIN OVER NATURAL GRADE & DECKS note: for new filled in roof section at entry use "Malarkey Roofing products legacy flexor sbs polymer modified laminated architectural shingles" see cutsheet provided as additional information. existing interior finishes no change ZIP System R Sheathing – Window Installation Step 1. Install sill/pan flashing that satisfies the requirements of ASTM E 2112-07. 6-inch ZIP System Tape may be used as pan flashing if installed in accordance with ASTM E 2112-07, Type III Pan Flashing – Multiple Pieces. Other adhesive-based flashing tapes may be used if they satisfy ICC-ES AC-148, Acceptance Criteria for Flexible Flashing Materials. Step 2. Apply sealant around inside face of window mounting flange. Sealant must be gapped at the bottom flange to permit drainage if used. Install and level window per manufacturer’s installation instructions. Verify sealant compatibility with window manufacturer. When using ZIP System Tape, 100% silicone, butyl and polyurethane sealants are acceptable. DO NOT use latex sealants. Step 3. Cut two pieces of ZIP System Tape (6-inch ZIP Tape is recommended) or other adhesive backed flashing tape (must meet ICC-ES AC148) and apply to each of the window jamb flanges. Ensure the jamb flashings overlap the sill flashing. Step 4. Cut a length of ZIP System Tape (6-inch ZIP Tape is recommended) or other adhesive backed flashing tape (must meet ICC-ES 148) and apply to the head flange on the window . Ensure the head flashing overlaps the jamb flashing. Once the tape is in place, apply sufficient pressure to the tape surfaces using the ZIP System Tape gun or roller. DO NOT tape bottom window flange. air sealing tape exterior joints EnergyShield continuous wall insulation air sealing new exterior roof deck caulked, glued or gasketed to existing wall sheathing & new roof deck flash and water proof joint between new roof and existing wall air sealing caulk, glue or gasket bottom edge of zip system to flashing at intersection of new roof to exisitng wall existing wall framing 5/8" drywall over "certainTeed membrain vapor & air bairier film" or approved equal Air sealing caulk, glue or gasket top edge of energyshield continuous insulation to existing sheathing at top plate SOFFIT FASCIA TO MATCH EXISTING DETAILS metal drip match existing NO CHANGE TO GRADE EXISTING FOUNDATION TO REMAIN NEW CLASS A METAL ROOF w versashield fire-resistant roof deck protection "drexelMetals dmc 150ss Profile" with "metshield high temp underlayment over w.r. Grace ice and water shield. See cutsheets provided as additional information Plane of airsealing to be the outside face of the new energyshield continuous insulation system. energyshield continuous insulation system joints to taped, windows & doors flashing taped, & sheathing perimeter intersections to be sealed per the Zip R system Sheathing Installation Manual 2" of sprayfoam in exterior side of cavity with remaining cavity 3 1/2" blown in batt r 21 2" of sprayfoam in exterior side of cavity with remaining cavity 3 1/2" blown in batt r 21 energyshield continuous wall insulation r5 install per manuf. specs over existing sheathing Air sealing caulk, glue or gasket bottom edge of energyshield continuous insulation to metal flashing Air sealing caulk, glue or gasket bottom edge of energyshield continuous insulation to metal flashing SCALE: 1" = 1'-0"1 WALL SECTION & DETAIL Table Footnotes:• "15/19" means R-15 continuous insulated sheathing on the interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. "15/19" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulated sheathing on the interior or exterior of the home. "10/13" means R-10 continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. • R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Zones 1 through 3 for heated slabs.• Or insulation sufficient to fill the framing cavity, R-19 minimum.• The first value is cavity insulation, the second value is continuous insulation, so “13+5” means R-13 cavity insulation plus R-5 continuous insulation.• The second R-value applies when more than half the insulation is on the interior of the mass wall. 2015 IECC Table R402.1.2 (as amended by City of Aspen Ordinance 40, 2016) CLIMATE ZONE FENESTRATION U-FACTOR SKYLIGHT U-FACTOR CEILING R-VALUE WOOD FRAME WALL R-VALUE MASS WALL R-VALUE FLOOR R-VALUE BASEMENT WALL R-VALUE SLAB R-VALUE & DEPTH CRAWL SPACE WALL R-VALUE 7 0.28 0.55 49 20 +5 or 13+10 h 19/21 i 38 g 15/19 c 10, 4 ftd 15/19 c jm permit 1/18/18 3/6/18permit v2jm 2015 international energy conservation code 04/26/2019 04/ 2 6 / 2 0 1 9 nic k t