unvented roof calc
HARDY BOARD
SIDING COLOR AND
STYLE TO BE
SELECTED
energyshield
continuous wall
insulation r5
install per manuf.
specs over existing
sheathing
EXISTING 1/2"
SHEATHING &
HOUSEWRAP
NEW 2x10
RAFTERS REFER
TO STRUCTURAL
DRAWINGS FOR
SPACING AND
ATTACHMENT
DETAILS
sprayfoam
entire cavity
r64/ Part of
continuous
insulation
system and air
sealing
NEW CLASS A METAL ROOF w
versashield fire-resistant roof
deck protection
"drexelMetals
dmc 150ss Profile"
with "metshield high temp
underlayment over w.r. Grace ice
and water shield. See cutsheets
provided as additional
information
metal flashing at
grade
12"
1/4"
rafters REFER TO
STRUCTURAL DRAWINGS
for sizing WITH 6"
closed cell
SPRAYFOAM INSULATION
r36 AND R19 BATTS
total r55
new roof assembly @ living
room
existing floor
assembly no change
existing floor
assembly no change
existing exterior wall
framing
exterior window and door
casing detail
zip r-sheathing
continuous r6
insulation system
install per manuf.
specs
existing exterior wall
with 1/2" sheathing
interior details and
finishes to remain
new hardy board siding exterior trim
new windows
ADD SNOW FENCE
AT NEW ROOFS
PLUS EXISTING
ROOFS THAT
DRAIN OVER
NATURAL GRADE
& DECKS
note: for new filled in roof section at entry use "Malarkey Roofing products legacy
flexor sbs polymer modified laminated architectural shingles" see cutsheet provided as
additional information.
existing interior
finishes no change
ZIP System R Sheathing – Window Installation
Step 1.
Install sill/pan flashing that satisfies the requirements
of ASTM E 2112-07. 6-inch ZIP System Tape may
be used as pan flashing if installed in accordance
with ASTM E 2112-07, Type III Pan Flashing
– Multiple Pieces. Other adhesive-based flashing
tapes may be used if they satisfy ICC-ES AC-148,
Acceptance Criteria for Flexible Flashing Materials.
Step 2.
Apply sealant around inside face of window
mounting flange. Sealant must be gapped at the
bottom flange to permit drainage if used. Install
and level window per manufacturer’s installation
instructions. Verify sealant compatibility with window
manufacturer. When using ZIP System Tape, 100%
silicone, butyl and polyurethane sealants are
acceptable. DO NOT use latex sealants.
Step 3.
Cut two pieces of ZIP System Tape (6-inch ZIP
Tape is recommended) or other adhesive backed
flashing tape (must meet ICC-ES AC148) and
apply to each of the window jamb flanges. Ensure
the jamb flashings overlap the sill flashing.
Step 4.
Cut a length of ZIP System Tape (6-inch ZIP Tape
is recommended) or other adhesive backed
flashing tape (must meet ICC-ES 148) and apply to
the head flange on the window
. Ensure the head
flashing overlaps the jamb flashing.
Once the tape is in place, apply sufficient pressure
to the tape surfaces using the ZIP System Tape
gun or roller.
DO NOT tape bottom window flange.
air sealing
tape exterior
joints
EnergyShield
continuous wall
insulation
air sealing
new exterior
roof deck
caulked, glued or
gasketed to
existing wall
sheathing & new
roof deck
flash and water
proof joint
between new
roof and
existing wall
air sealing
caulk, glue or
gasket bottom
edge of zip
system to
flashing at
intersection of
new roof to
exisitng wall
existing
wall
framing
5/8" drywall over
"certainTeed membrain
vapor & air bairier
film" or approved
equal
Air sealing
caulk, glue or
gasket top edge
of energyshield
continuous
insulation to
existing
sheathing at top
plate
SOFFIT
FASCIA TO
MATCH EXISTING
DETAILS
metal drip match
existing
NO CHANGE TO
GRADE EXISTING
FOUNDATION TO
REMAIN
NEW CLASS A METAL ROOF w
versashield fire-resistant roof
deck protection
"drexelMetals
dmc 150ss Profile"
with "metshield high temp
underlayment over w.r. Grace ice
and water shield. See cutsheets
provided as additional
information
Plane of airsealing to be
the outside face of the new
energyshield continuous
insulation system.
energyshield continuous
insulation system joints to
taped, windows & doors
flashing taped, & sheathing
perimeter intersections to
be sealed per the Zip R
system Sheathing
Installation Manual
2" of sprayfoam in
exterior side of cavity
with remaining cavity
3 1/2" blown in batt
r 21
2" of sprayfoam in
exterior side of cavity
with remaining cavity
3 1/2" blown in batt
r 21
energyshield
continuous wall
insulation r5
install per manuf.
specs over existing
sheathing
Air sealing
caulk, glue or
gasket bottom
edge of
energyshield
continuous
insulation to
metal flashing
Air sealing
caulk, glue or
gasket bottom
edge of
energyshield
continuous
insulation to
metal flashing
SCALE: 1" = 1'-0"1 WALL SECTION & DETAIL
Table Footnotes:• "15/19" means R-15 continuous insulated sheathing on the interior or exterior of the home or R-19 cavity insulation at the interior of the basement wall. "15/19" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulated sheathing on the interior or exterior of the home. "10/13" means R-10 continuous insulated sheathing on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall.
• R-5 shall be added to the required slab edge R-values for heated slabs. Insulation depth shall be the depth of the footing or 2 feet, whichever is less in Zones 1 through 3 for heated slabs.• Or insulation sufficient to fill the framing cavity, R-19 minimum.• The first value is cavity insulation, the second value is continuous insulation, so “13+5” means R-13 cavity insulation plus R-5 continuous insulation.• The second R-value applies when more than half the insulation is on the interior of the mass wall.
2015 IECC Table R402.1.2 (as amended by City of Aspen Ordinance 40, 2016)
CLIMATE ZONE FENESTRATION U-FACTOR SKYLIGHT U-FACTOR CEILING R-VALUE WOOD FRAME WALL R-VALUE MASS WALL R-VALUE FLOOR R-VALUE BASEMENT WALL R-VALUE SLAB R-VALUE & DEPTH CRAWL SPACE WALL R-VALUE 7 0.28 0.55 49 20 +5 or 13+10 h 19/21 i 38 g 15/19 c 10, 4 ftd 15/19 c
jm permit 1/18/18
3/6/18permit v2jm
2015 international energy conservation code