Loading...
HomeMy WebLinkAboutFile Documents.1230 Snowbunny Ln.0001.2020 (6).BCHOListings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright © 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 11 ICC-ES PMG Product Certificate PMG-1213 Effective Date: March 2019 Revision Date: August 29, 2019 This listing is subject to re-examination in one year. www.icc-es-pmg.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council® CSI: DIVISION: 10 00 00—SPECIALTIES Section: 10 32 00—Fireplace Specialties Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier’s stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier’s quality system. Product: Outdoor Decorative Gas Fire Pit and Fireplaces Listee: Warming Trends, LLC 4731 S. Sante Fe Circle #2 Englewood, CO 80110 www.warming-trends.com Compliance with the following codes: 2018, 2015, 2012 and 2009 International Fire Code® (IFC) 2018, 2015, 2012 and 2009 International Fuel Gas Code® (IFGC) 2018, 2015, 2012 and 2009 Uniform Mechanical Code® (UMC)* 2015 and 2010 Natural Gas and Propane Installation Code** *Copyrighted publication of the International Association of Plumbing and Mechanical Officials ** Copyrighted publication of Canadian Standard Association Compliance with the following standards: ANSI Z21.97/CSA 2.41-2017 Outdoor Decorative Gas Appliances Identification: Marking material shall be identified by class number and shall meet the following specifications. All metal marking materials shall be rustproof. All marking shall be suitable for application to surfaces upon which applied and shall demonstrate suitable legibility. The designation of any class of marking shall not preclude the use of marking of a lower number class. Class I. Integral Marking Marking that is embossed, cast, stamped or otherwise formed in the part. This includes markings baked into an enameled surface. Class IIA-1. Permanent Plate Shall be made of metal having a minimum thickness of 0.012 in (0.30 mm) and shall be securely attached by mechanical means. PMG-1213 | Most Widely Accepted and Trusted Page 2 of 11 Class IIA-2. Permanent Plate Shall be made of metal having a thickness of 0.006 to 0.012 in (0.15 to 0.30 mm) and shall have mechanical attachment means at all corners with a maximum spacing of 6 in (152 mm) between mechanical fasteners. Class IIA-3. Permanent Plate Shall be made of metal having a thickness less than 0.006 in (0.15 mm) and shall be attached by means of non-water-soluble adhesive. These materials shall not be located on surfaces having temperatures exceeding 300°F. Class IIA-4. Permanent Plate Shall be made of pressure-sensitive metal foil requiring no solvent or activator and shall not be located on surfaces having temperatures exceeding 300°F (149°C). Class IIIA-1. Permanent Label Shall be made of material not adversely affected by water, shall be attached by means of non-water- soluble adhesive and shall not be located on surfaces having temperatures exceeding 300°F (149°C). Class IIIA-2. Permanent Label Shall be made of material not adversely affected by water, shall be attached by means of non-water- soluble adhesive and shall not be located on surfaces having temperatures exceeding 175°F (79.5°C). Class IIIB. Waterproof Marking Shall be printed directly on the part with waterproof marking not adversely affected by a temperature of 175°F (79.5°C) and shall not be used on surfaces having temperatures exceeding 175°F (79.5°C). Class IIIC. Waterproof Label Shall be made of material not soluble in water, and may use water-soluble adhesive for attachment means. Class IV. Semi-Permanent Plate or Label Shall be made of material which may be soluble in water and may use water-soluble adhesive for attachment means. Class V. Printed Marking Marking shall be clear and prominent and may be applied directly by any printing means. Class VI. Attached Tags The appliance shall bear the following information on a Class III marking affixed to the principal (main) assembly of the appliance and shall be attached or printed in a location where it can be easily observed or is readily accessible for observation when the appliance is installed as it would be in service. a) The manufacturer or distributor’s name and address. b) The manufacturer or distributor’s model number of the appliance. c) A distinctive number which will identify an individual appliance. d) For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator, the normal manifold pressure in inches water column. e) For appliances for fixed fuel piping system and equipped with an appliance gas pressure regulator, the minimum permissible gas supply pressure for purpose of input adjustment. f) Type of gas for which equipped: “Natural” or “Propane.” g) The statement “For Outdoor Use Only. If Stored Indoors, Detach and Leave Cylinder Outdoors.” The marking for an appliance for connection to a fixed fuel piping system need only display the first sentence of this statement. h) If the appliance utilizes any electrical equipment, the voltage, frequency (Hz) and total current input in amperes. If the total current input of all components is less than 12 amperes, the input marking may optionally be shown as “Less than _____* amperes.” (* This amperage rating shall be equal to or greater than the total input in amperes.) i) Identification of this requirement as follows: PMG-1213 | Most Widely Accepted and Trusted Page 3 of 11 “ANS Z21.97-(year), Outdoor Decorative Gas Appliances;” “ANS Z21.97a-(year), Outdoor Decorative Gas Appliances;” or “ANS Z21.97b-(year), Outdoor Decorative Gas Appliances”. Clearly defined and complete instructions for lighting and shutting down the appliance shall be provided on Class IIIA marking material. These instructions shall be located on or adjacent to the controlling device or in an equally conspicuous position, where they can be easily read. Lighting instructions shall specify a 5-minute complete shutoff period before the appliance is re-lighted. Exception: Match lit appliances for use with a single disposable cylinder at an input of 12,000 Btu/hr (3,516 W) or less are exempt from this requirement. Appliances shall bear a Class IIIA marking indicating all minimum clearances from combustible construction. Appliances for installation only on or over noncombustible floors shall be marked “For Installation on (or over) Noncombustible Floors Only” on Class IIIA marking material. A label of Class IIIC marking material shall, when practical, be affixed to the appliance in a conspicuous location by the manufacturer. When not practical, this label shall be supplied by the manufacturer with explicit instructions to affix the label in a conspicuous location adjacent to the appliance. This label shall include the following information: WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. Each appliance shall bear a plate of Class IIIA marking material, located so as to be easily read when the appliance is in a normally installed position, on which shall appear the following: WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. If a cover is provided to protect the appliance burner when the appliance is not in use, or during storage of the appliance, the cover shall bear a permanent marking on Class IIIA marking material as follows: “Cover must be removed when burner is in operation.” If wire other than that conforming to the temperature limitation of 63°F (35°C) rise has been specified for use on the appliance, the following statement shall also appear on all electrical diagrams: “If any of the original wire as supplied with the appliance must be replaced, it must be replaced with type wire of its equivalent.” (The appropriate wire type is to be indicated in the blank space.) Electrical diagrams shall conform to the Standard for Electrical and Electronics Diagrams, ANSI Y14.15. (See Appendix A, Pertinent References to ANSI Y14.15, for reference to pertinent provisions of ANSI Y14.15.) The wire color designations specified in ANSI Y14.15 are shown in Appendix B, Wire Color Designations. Unidentified graphical symbols used for electrical diagrams shall conform to the Standard for Graphic Symbols for Electrical and Electronics Diagrams (Including Reference Designation Class Designation Letters), ANSI/IEEE Standard 315. Appliances for connection to a self-contained LP-gas supply system shall bear the following marking on a Class IIIA marking material: “CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of inches water column.” (The outlet pressure is specified by the manufacturer. PMG-1213 | Most Widely Accepted and Trusted Page 4 of 11 Appliances for connection to a self-contained LP-gas supply system shall bear the following applicable statement on Class IIIA marking material located so as to be easily read: a) For an appliance provided with a connection other than a CGA No. 600 Cylinder Connection Device: “The gas supply must be turned off at the LP-gas supply cylinder when this appliance is not in use.” b) For an appliance provided with a CGA No. 600 Cylinder Connection Device: “The LP-gas supply cylinder must be disconnected when this appliance is not in use.” Appliances for connection to a self-contained LP-gas supply system utilizing a CGA No. 600 Cylinder Connection Device shall bear a Class IIIA marking to the effect that only cylinders marked “propane” shall be used. Appliances specifically designed for direct connection to the fuel supply cylinder shall bear a clearly legible Class IIIA marking stating, “Do not connect to a remote gas supply.” CLEARANCE MARKING Each appliance shall bear a marking on Class III marking material, located at the minimum clearances from spacers, standoffs, or surfaces to combustible construction for all appliance and vent surfaces. The marking for clearances shall indicate that the left and right sides are determined when facing the front of the appliance. For an appliance equipped with an external draft hood, the marking shall specify the minimum clearance in integral inches between the draft hood and the nearest combustible construction. An appliance which requires clearances from any type of construction for serviceability or proper operation shall bear a marking on Class III marking material, located on the surface(s) requiring such clearance indicating the minimum distance required. In addition, each appliance for installation recessed within combustible construction shall bear a Class V marking specifying the depth to which it may be recessed. For an appliance with specified clearances from projections above the appliance, the marking shall indicate the minimum vertical clearance from the projection and the maximum horizontal extension of the projection over the appliance. Models: Fireplaces and Fire Pits Model Number Description SIMP24 24” Simplicity Fire Bowl SIMP38 38” Simplicity Fire Bowl CSIMP36 36” Simplicity Fire Bowl CSIMP40 40” Simplicity Fire Bowl Note: All models may contain one of the burners listed in the table below: 40K BTU/h Burner Model Number Description WTV40 (NG, LP) Match Lit, Burner Type: Rectangular PMG-1213 | Most Widely Accepted and Trusted Page 5 of 11 60K BTU/h Burner Model Number Description HMLS60-*NG Honeywell, Natural Gas HMLS60-*LP Honeywell, Propane Gas DMLS60-*NG Dexen, Natural Gas DMLS60-*LP Dexen, Propane Gas MLS-60 NG Match Lit, Natural Gas MLS-60 LP Match Lit, Propane Gas CFB-60-*NG Crossfire, Natural Gas CFB-60-*LP Crossfire, Propane Gas 3576/EO10LP Propane Gas 3577/EO10NG Natural Gas 3578/3O20LP Propane Gas 3579/EO20NG Natural Gas 3580/EO30LP Propane Gas 3581/EO30NG Natural Gas 3582/EO40LP Propane Gas 3583/EO40NG Natural Gas 3584/EO50LP Propane Gas 3585/EO50NG Natural Gas 3586/EO60LP Propane Gas 3587/EO60NG Natural Gas 3588/EO70LP Propane Gas 3589/EO70NG Natural Gas 3590/EO80LP Propane Gas 3591/EO80NG Natural Gas 3592 Propane Gas 3593 Natural Gas 3594 Propane Gas 3595 Natural Gas 3596 Propane Gas 3597 Natural Gas 3600 Propane Gas 3601 Natural Gas 3602 Propane Gas 3603 Natural Gas 3604 Propane Gas 3605 Natural Gas 3606 Propane Gas 3607 Natural Gas 3608 Propane Gas 3609 Natural Gas 3610 Propane Gas 3611 Natural Gas 3612 Propane Gas 3613 Natural Gas 3614 Propane Gas 3615 Natural Gas 3616 Propane Gas 3617 Natural Gas 3618 Propane Gas PMG-1213 | Most Widely Accepted and Trusted Page 6 of 11 3619 Natural Gas 3620 Propane Gas 3621 Natural Gas 3622 Propane Gas 3623 Natural Gas WTV60 (NG, LP) Match Lit, Burner Type: Rectangular * represents ignition system type: 3V, 3VIK, 24V, 24VIK, MLS 65K BTU/h Burner Model Number Description CFB60 2XL (NG, LP) Match Lit, Burner Type: H-Style CFBH-120 (NG, LP) Match Lit, Burner Type: H-Style CFBH-160 (NG, LP) Match Lit, Burner Type: H-Style CFBH-200 (NG, LP) Match Lit, Burner Type: H-Style CFBH-240 (NG, LP) Match Lit, Burner Type: H-Style CFBH-260 (NG, LP) Match Lit, Burner Type: H-Style CFBH-300 (NG, LP) Match Lit, Burner Type: H-Style CFBH-340 (NG, LP) Match Lit, Burner Type: H-Style CFBH-420 (NG, LP) Match Lit, Burner Type: H-Style CFBL-90 (NG, LP) Match Lit, Burner Type: Linear CFBL-110 (NG, LP) Match Lit, Burner Type: Linear CFBL-130 (NG, LP) Match Lit, Burner Type: Linear CFBL-150 (NG, LP) Match Lit, Burner Type: Linear CFBL-190 (NG, LP) Match Lit, Burner Type: Linear CFBL-210 (NG, LP) Match Lit, Burner Type: Linear CFBL-250 (NG, LP) Match Lit, Burner Type: Linear CFBL-270 (NG, LP) Match Lit, Burner Type: Linear CFBL-320 (NG, LP) Match Lit, Burner Type: Linear CFBO-180 (NG, LP) Match Lit, Burner Type: Octagon CFBO-280 (NG, LP) Match Lit, Burner Type: Octagon CFBO-360 (NG, LP) Match Lit, Burner Type: Octagon CFBT-110 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-170 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-230 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-290 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-350 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-410 (NG, LP) Match Lit, Burner Type: Tree Style CFBT-470 (NG, LP) Match Lit, Burner Type: Tree Style CFB240 (NG, LP) Match Lit, Burner Type: Rectangular WTV120 (NG, LP) Match Lit, Burner Type: Rectangular WTV180 (NG, LP) Match Lit, Burner Type: Rectangular WTVES120 (NG, LP) Match Lit, Burner Type: Rectangular WTVES180 (NG, LP) Match Lit, Burner Type: Rectangular WTVT230 (NG, LP) Match Lit, Burner Type: Tree Style WTVT350 (NG, LP) Match Lit, Burner Type: Tree Style PMG-1213 | Most Widely Accepted and Trusted Page 7 of 11 Model Number Description CFB60 2XL-(NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-120 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-160 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-200 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-240 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-260 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-300 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBH-340 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: H-Style CFBL-90 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-110 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-130 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-150 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-190 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-210 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFBL-250 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Linear CFB240 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Rectangular CFBO-180 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Octagon CFBO-280 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Octagon CFBO-360 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Octagon CFBT-110 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-170 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-230 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-290 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-350 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-410 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style CFBT-470 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Tree- Style WTV60 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Rectangular WTV120 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Rectangular WTV180 (NG, LP) – 3VIK Dexen Controls – 3V Battery Operated, Burner Type: Rectangular Model Number Description CFB60 2XL-(NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-120 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-160 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-200 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-240 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-260 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: H-Style PMG-1213 | Most Widely Accepted and Trusted Page 8 of 11 CFBH-300 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-340 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBH-420 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: H-Style CFBL-90 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-110 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-130 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-150 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-190 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-210 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-250 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-270 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Linear CFBL-320 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Linear CFB240 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Rectangular CFBO-180 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Octagon CFBO-280 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Octagon CFBO-360 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Octagon CFBT-110 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-170 (NG, LP) – 24VIKSC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-230 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-290 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-350 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-410 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style CFBT-470 (NG, LP) – 24VIKHC Honeywell – 24V Spark Ignition, Burner Type: Tree-Style WTV60 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Rectangular WTV120 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Rectangular WTV180 (NG, LP) – 24VIKHC (SC, HC) Honeywell – 24V Spark Ignition, Burner Type: Rectangular Note: High Capacity (HC) ignitions may be substituted for Standard Capacity (SC) ignitions Model Number Description CFB60 2XL-(NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-120 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-160 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-200 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-240 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-260 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-300 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-340 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBH-420 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: H- Style CFBL-90 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear PMG-1213 | Most Widely Accepted and Trusted Page 9 of 11 CFBL-110 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-130 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-150 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-190 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-210 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-250 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-270 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFBL-320 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: Linear CFB240 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Rectangular CFBO-180 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Octagon CFBO-280 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Octagon CFBO-360 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: Octagon CFBT-110 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-170 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-230 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-290 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-350 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-410 (NG, LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style CFBT-470 (NG ,LP) – P24VIKHC AWEIS – 24V Hot Surface Ignition, Burner Type: Tree- Style WTV60 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Rectangular WTV120 (NG, LP) – P24VIKSC (SC, HC) AWEIS – 24V Hot Surface Ignition, Burner Type: Rectangular WTV180 (NG, LP) – P24VIKSC AWEIS – 24V Hot Surface Ignition, Burner Type: Rectangular CROSSFIRETM BRASS BURNER MATCH LIT SYSTEMS Model Number Description CFB60LP CFB60LP burner, plate or pan, lava rock CFB60NG CFB60NG burner, plate or pan, lava rock CFB120LP CFB120LP burner, plate or pan, lava rock, gas reducing orifice CFB120NG CFB120NG burner, plate or pan, lava rock, gas reducing orifice CFB180LP CFB180LP burner, plate or pan, lava rock, gas reducing orifice CFB180NG CFB180NG burner, plate or pan, lava rock, gas reducing orifice CFB290LP CFB290LP burner, plate or pan, lava rock, gas reducing orifice CFB290NG CFB290NG burner, plate or pan, lava rock, gas reducing orifice PMG-1213 | Most Widely Accepted and Trusted Page 10 of 11 CROSSFIRETM BRASS BURNER 3V BATTERY OPERATED SYSTEMS Model Number Description CFB60LP-3VIK CFB60LP burner, plate or pan, lava rock, 3 Volt Battery Operated Electronic Ignition System CFB60NG-3VIK CFB60NG burner, plate or pan, lava rock, 3 Volt Battery Operated Electronic Ignition System CFB120LP-3VIK CFB120LP burner, plate or pan, lava rock, 3 Volt Battery Operated Electronic Ignition System CFB120NG-3VIK CFB120NG burner, plate or pan, lava rock, 3 Volt Battery Operated Electronic Ignition System CROSSFIRETM BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS – Premium - Standard Capacity Model Number Description CFB60LP- P24VIKSC CFB60LP, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB60NG- P24VIKSC CFB60NG, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB120LP- P24VIKSC CFB120LP, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB120NG- P24VIKSC CFB120NG, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB180LP- P24VIKSC CFB180LP, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB180NG- P24VIKSC CFB180NG, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB290LP- P24VIKSC CFB290LP, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CFB290NG- P24VIKSC CFB290NG, plate or pan, lava rock, Premium 24 Volt standard capacity electronic ignition system CROSSFIRETM BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS – Premium - High Capacity Model Number Description CFB300LP- P24VIKHC CFB300LP, plate or pan, lava rock, Premium 24 Volt high capacity electronic ignition system CFB300NG- P24VIKHC CFB300NG, plate or pan, lava rock, Premium 24 Volt high capacity electronic ignition system CROSSFIRETM BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS – Standard - Standard Capacity Model Number Description CFB60LP- 24VIKSC CFB60LP, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system CFB60NG- 24VIKSC CFB60NG, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system CFB120LP- 24VIKSC CFB120LP, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system CFB120NG- 24VIKSC CFB120NG, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system CFB180LP- 24VIKSC CFB180LP, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system CFB180NG- 24VIKSC CFB180NG, plate or pan, lava rock, Standard 24 Volt standard capacity electronic ignition system PMG-1213 | Most Widely Accepted and Trusted Page 11 of 11 CROSSFIRETM BRASS BURNER 24 VOLT ELECTRONIC IGNITION SYSTEMS – Standard - High Capacity Model Number Description CFB290LP- 24VIKHC CFB290LP, plate or pan, lava rock, Standard 24 Volt high capacity electronic ignition system CFB290NG- 24VIKHC CFB290NG, plate or pan, lava rock, Standard 24 Volt high capacity electronic ignition system CFB300LP- 24VIKHC CFB300LP, plate or pan, lava rock, Standard 24 Volt high capacity electronic ignition system CFB300NG- 24VIKHC CFB300NG, plate or pan, lava rock, Standard 24 Volt high capacity electronic ignition system Conditions of listing: 1. The product shall comply with sections 303.6 and 303.7 of the International Mechanical Code, section G2454.1 of the International Residential code, section 636.1 of the International Fuel Gas Code as well as section 932.0 of the Uniform Mechanical Code. 2. Installation shall be in accordance with the manufacturer’s instructions and the requirements of the code sections references above. 3. The products are under a quality control program with an annual surveillance inspection by ICC- ES.