Loading...
HomeMy WebLinkAboutFile Documents.135 E Cooper Ave.0134.2019 (3).ARBK Property Address 135 E. Cooper Aspen, CO 81611 Element Environmental Project#: Eigelberger 060719 Main Client Job Name Historical Main TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion 9.0 - Lab Report 10.0 - Certificates Asbestos Samples Analyzed: 16 Positive Asbestos Samples: 0 ___________________________________________________ ASBESTOS LEAD HAZMAT RESTORATION www.elementconsults.com Asbestos Sampling Report Date: 06/11/2019 Date of Inspection: 06/07/2019 Client: Eigelberger Architecture and Design 350 Market St. Suite 309 Basalt, CO 81621 Attn: Natacha Denis Building Inspector: Ellen Johnson CDPHE #23799 Joshua Johnson CDPHE #18401 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970) 274-3139 06/13/2019 Project #-Eigelberger 060719 Main 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a relocation and remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 2 samples 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. 06/13/2019 Project #-Eigelberger 060719 Main 3 5.0- SUSPECT MATERIALS SAMPLES • Drywall • Joint Compound • Texture • Tape • Carpet and Pad • Tile Grout • Window Glazing 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA ACM CATEGORY NUMBER OF SAMPLES APPROXIMATE SQ.FT.* ACM ASSESSMENT CATEGORIES % AND TYPE OF ASBESTOS FOUND (A) Window Glazing on Doors and Windows Miscellaneous 2 ~4 sq.ft. Non-Friable Non ACM No Asbestos Detected (B) Tar Paper under Wood Shingles and Metal Roofing Miscellaneous 2 ~2000 sq.ft. Non-Friable Non ACM No Asbestos Detected (C) Light Roll Texture on the Main Level Surfacing 5 ~4500 sq.ft. Friable Non ACM No Asbestos Detected (D) Light Roll Texture on the 2nd and 3rd Levels Surfacing 5 ~4500 sq.ft. Friable Non ACM No Asbestos Detected (E) Carpet in the Bedrooms Miscellaneous 2 ~1200 sq.ft. Non-Friable Non ACM No Asbestos Detected Key: ACM Assessment Categories: 1- Damaged or significantly damaged Thermal Systems Insulation (TSI) ACM 2- Damaged friable surfacing ACM 3- Significantly damaged friable Surfacing ACM 4- Damaged or significantly damaged friable Miscellaneous ACM 5- ACM with potential for damage 6- ACM with potential for significant damage 7- Friable ACM with low potential for damage Other- ACM not classified in the above Assessment Categories N/A- Not Applicable * Square footage is estimated and not for bidding purposes 06/13/2019 Project #-Eigelberger 060719 Main 4 7.0- DESCRIPTION OF SAMPLING AREA • The Window and Door Glazing • The Tar Paper under the wood shingles and metal roofing material • The Light Roll Texture on the walls and ceilings throughout • The Carpet and Pad in the bedrooms 8.0- CONCLUSION. No Asbestos was detected in any of the samples tested. Sincerely, Ellen Johnson 06/13/2019 Project #-Eigelberger 060719 Main 5 9.0- LAB REPORT 06/13/2019 Project #-Eigelberger 060719 Main 6 06/13/2019 Project #-Eigelberger 060719 Main 7 06/13/2019 Project #-Eigelberger 060719 Main 8 06/13/2019 Project #-Eigelberger 060719 Main 9 06/13/2019 Project #-Eigelberger 060719 Main 10 06/13/2019 Project #-Eigelberger 060719 Main 11 06/13/2019 Project #-Eigelberger 060719 Main 12 06/13/2019 Project #-Eigelberger 060719 Main 13 06/13/2019 Project #-Eigelberger 060719 Main 14 10.0- CERTIFICATES 06/13/2019