HomeMy WebLinkAboutFile Documents.210 E Cooper Ave.0171.2018 (5).ARBKGENERAL INFORMATION
INSTALLER! PLEASE LEAVE WITH HOMEOWNER
INSTALLATION AND OPERATING INSTRUCTIONS
This appliance is to be burned only in an approved woodburning Fireplace with adequate chimney draft.
When burning, the chimney damper must be FULLY OPEN.
This appliance must be installed in a fireplace which operates
properly when wood fires are burned.
• For best results, natural gas pressure must be 7” to 10-1/2” water
column.
• If used with glass fireplace doors, burn with doors in open position.
• Do not burn wood or other items with this appliance.
Please Note: It is important that you read instructions before installing or operating this appliance
MANUFACTURED BY:
4301 WESTGROVE DRIVE
ADDISON, TX 75001
The installation, including provisions for combustion and
ventilation air, must conform with local codes or, in the
absence of local codes, with the National Fuel Gas Code,
ANSI Z223.1-1988 and NFPA54-1988.
The appliance and its individual shutoff valve must be
disconnected from the gas supply piping system when testing
at test pressures in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve during
any pressure testing of gas-supply system at test pressures
equal to or less than 1/2 psig. This is accomplished by closing
the gas supply line valve, which is required by NFPA 54,
section 5.54
The minimum inlet gas supply pressure for the
purpose of input adjustment is 7” WC for Natural Gas
and 11” WC for Propane Gas.
The maximum inlet gas supply pressure for this burner
is 10.5” for Natural Gas and 13” for Propane Gas.
This appliance is designed for use with Natural Gas unless clearly labeled for Propane (LP). Never use Propane Gas in an
appliance designed for Natural Gas or Natural Gas in an appliance designed for use of Propane Gas.
FOR YOUR SAFETY
If you smell gas:
1. Open Windows.
2. Don’t touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
IMPORTANT INFORMATION
CHECK TO BE SURE APPLIANCE IS FOR PROPER GAS TYPE.
6/22/2018
COMPONENTS PARTS
ITEM
1. Alpine Linear Burner
2. Silica Sand
3. Vermiculite
4. Black Volcanic Cinders
5. Glowing Embers
6. Gas Connector
7. Damper Clamp
ALPINE LINEAR BURNER SPECIFICATIONS
*The gas fittings supplied are for what the
factory considers a normal installation.
Some installations may require a longer
connector tube or other fittings available in
most hardware stores.
1
MODEL #MINIMUM FIREBOX BTU/HR
WIDTH AT 7” DEEP
FROM FRONT FIREBOX
ALB24NAT 26” 22,500
ALB30NAT 32” 25,250
ALB36NAT 38” 34,000
ALB42NAT 44” 39,600
ALB48NAT 50” 44,352
ALB60NAT 62” 56,175
ALB72NAT 74” 68,000
ALB24LP 26”20,500
ALB30LP 32”31,000
ALB36LP 38”37,750
ALB42LP 44”43,800
ALB48LP 50”49,000
ALB60LP 62”62,250
ALB72LP 74”75,500
6”
6”
Width sam
e
a
s
M
o
d
el
Unit Dimensions
6/22/2018
TO INSTALL LINEAR BURNER:
1. Attach damper clamp to fireplace damper to
prevent damper from being fully closed.
2. Position burner assembly into fireplace and
position in center of floor.
3. Attach Gas connector to gas supply line and
connect to burner assembly. Use soapy water to
check connections for leaks. (Figure 3-1)
4. Pour silica sand into burner pan completely
covering pipe in pan. For LP Gas models, use
vermiculite instead of sand. (Figure 3-2)
NOTE! Optional decorative fireglass can be
susbstituted for silica sand or vermiculite (LP) for
a more contemporary design if desired
(Figure 3-5).
5. Place glowing ember material over sand
(Vermiculite LP). (Figure 3-3) Note: Not used if
optional decorative fireglass is used.
Spread the black volcanic cinders in front of and
on sides of Linear Burner (Figure 3-4)
NOTE! Optional Decorative Fireglass can also
be used in place of black volcanic cinders.
(Figure 3-5)
YOU ARE NOW READY TO LIGHT THE BURNER BY TURNING THE FIREPLACE GAS VALVE ON AND USING A
LONG MATCH OR BUTANE LOG LIGHTER. LIGHT THE BURNER BY POSITIONING MATCH OR LIGHTER JUST
OVER BURNER WHILE TURNING ON THE GAS VALVE. DURING THE FIRST FEW HOURS OF OPERATION, AN
OCASSIONAL POPPING SOUND CAN BE HEARD AS A RESULT OF THE METAL EXPANDING FROM HEAT. THIS
WILL STOP AFTER A SHORT PERIOD OF TIME.
Lighting instructions for “Alpine Linear
Burners” with a millivolt, spark to pilot,
or S-model “Skytech Hi/Lo” valve located
on subsequent pages of this manual.
Figure 3-1 Figure 3-2
Figure 3-3 Figure 3-4
Figure 3-5
DAMPER MUST BE IN FULL OPEN POSITION
BEFORE LIGHTING.
6/22/2018
LIGHTING INSTRUCTIONS FOR
“S-MODEL” SKYTECH REMOTE HI-LO MOTOR MODELS
To Turn OFF Gas To Appliance
1.Turn off switch or remote.
2.Remove Decorative Front
3.Turn control knob clockwise to “PILOT”
4.Depress control knob slightly and turn
clockwise to “OFF”
A.The Golden Blount appliance has a pilot which must
be lit by hand. When lighting the pilot, follow these
instructions exactly.
B.Before Lighting, smell all around the area for gas. Be
sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch, do not use any
phone in your building.
•Immediately call your gas supplier from your
neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call the fire
department.
C.Use only your hand to push in or turn gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don’t try to repair it. Call a qualified
service technician. Force or attempted repair may
result in fire or explosion.
D.Do not use the appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the appliance set and to replace any part of
the control system and any gas control system and
any gas control which has been under water.
E.FIREPLACE DAMPER MUST BE FULLY OPENED.
FOR YOUR SAFETY,
READ BEFORE LIGHTING
Pilot Burner Location
Decorative Front
Screw
Remote Control
Connector 1.“Stop!” First read the safety information
at the left.
2. Remove two screws from sides of burner
and take off decorative front to access
control valve.
3. Turn the control to the “OFF” position. To do
this, you must turn the knob clockwise
to the “PILOT” position and then press
in and continue turning clockwise to the
“OFF” position.
4.WAIT FIVE (5) MINUTES TO CLEAR
OUT ANY GAS.
If you then smell gas, STOP! Follow step
“B” in the safety information at the left. If
you don’t smell gas, go to the next step.
5. To put the control in the pilot position, turn
the control knob counter-clockwise to
the“PILOT” position.
6. To light the pilot, depress the control knob
and light the pilot using a long match or
extended butane lighter. The control knob
should be held IN for 1 minute.
7. Release the control knob. The pilot should
remain lit after releasing.
8. Turn the control knob counter-clockwise
to the “ON” position.
9. Connect RCAF-1031 Remote control
receiver to connector on control valve and
position receiver behind burner assembly
on floor of fireplace.
10. Replace decorative front and follow
operation instructions supplied with
RCAF-1031 Remote Control.
WARNING:WARNING:WARNING:WARNING:WARNING: IF YOU DO NOT FOLLOW
THESE INSTRUCTIONS EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE
Control
Knob
6/22/2018
A.The Golden Blount appliance has a pilot which must
be lit by hand. When lighting the pilot, follow these
instructions exactly.
B.Before Lighting, smell all around the area for gas. Be
sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch, do not use any
phone in your building.
•Immediately call your gas supplier from your
neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call the fire
department.
C.Use only your hand to push in or turn gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don’t try to repair it. Call a qualified
service technician. Force or attempted repair may
result in fire or explosion.
D.Do not use the appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the gas log set and to replace any part of
the control system and any gas control system and
any gas control which has been under water.
E.FIREPLACE DAMPER MUST BE FULLY OPENED.
WARNING:WARNING:WARNING:WARNING:WARNING: IF YOU DO NOT FOLLOW
THESE INSTRUCTIONS EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE
FOR YOUR SAFETY,
READ BEFORE LIGHTING
To Turn OFF Gas To Appliance
1.Turn off switch or remote.
2.Remove Decorative Front
3.Turn control knob clockwise to “PILOT”
4.Depress control knob slightly and turn
clockwise to “OFF”
LIGHTING INSTRUCTIONS FOR
MILLIVOLT CONTROL VALVE MODELS
Decorative
Front Screw
On/Off Switch
Pilot Burner Location
Gas Control Knob
1.“Stop!” First read the safety information
at the left.
2. Remove two screws from sides of burner
and take off decorative front to access
control valve.
3. Turn the control to the “OFF” position. To do
this, you must turn the knob clockwise
to the “PILOT” position and then press in and
continue turning clockwise to the
“OFF” position.
4.WAIT FIVE (5) MINUTES TO CLEAR
OUT ANY GAS.
If you then smell gas, STOP! Follow step
“B” in the safety information at the left.
If you don’t smell gas, go to the next step.
5. To put the control in the pilot position, turn
the control knob counter-clockwise to
the“PILOT” position.
6. To light the pilot, depress the control knob
and light the pilot using a long match or
extended butane lighter. The control knob
should be held IN for 1 minute.
7. Release the control knob. The pilot should
remain lit after releasing.
8. Turn the control knob counter-clockwise
to the “ON” position.
9. Replace decorative front and turn on switch,
wall switch or on/off remote connected to
wire leads tagged “For Remote or Wall
Switch”
6/22/2018
LIGHTING INSTRUCTIONS FOR
“STP” SPARK-TO-PILOT CONTROL VALVE MODELS
To Turn OFF Gas To Appliance
1.Turn off switch or remote.
1.“Stop!” First read the safety information at
the left.
2. Remove two screws from sides of burner
and take off decorative front to access
control compartment.
3. Install two “D” batteries into Battery Pack
located in control compartment.
4. Replace Decorative Front
5. Turn on switch, wall switch or ON/OFF
remote connected to wire leads tagged
“For Remote or Wall Switch”
Decorative
Front Screw
On/Off Switch
A.The Golden Blount appliance has a pilot which must
be lit by hand. When lighting the pilot, follow these
instructions exactly.
B.Before Lighting, smell all around the area for gas. Be
sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
•Do not try to light any appliance.
•Do not touch any electrical switch, do not use any
phone in your building.
•Immediately call your gas supplier from your
neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call the fire
department.
C.Use only your hand to push in or turn gas control
knob. Never use tools. If the knob will not push in or
turn by hand, don’t try to repair it. Call a qualified
service technician. Force or attempted repair may
result in fire or explosion.
D.Do not use the appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the gas log set and to replace any part of
the control system and any gas control system and
any gas control which has been under water.
E.FIREPLACE DAMPER MUST BE FULLY OPENED.
WARNING:WARNING:WARNING:WARNING:WARNING: IF YOU DO NOT FOLLOW
THESE INSTRUCTIONS EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY
OR LOSS OF LIFE
FOR YOUR SAFETY,
READ BEFORE LIGHTING
Gas Control
Valve
Battery
Pack
Control
Module
Pilot Burner
Location
LIMITED WARRANTY
Alpine Linear Burners are warranted against
defective materials and/or workmanship for five
years from date of purchase.
Safety Pilot Assemblies, Gas Control Valves, Flame
Sensors and other ignition components are covered
for one year.
This warranty does not cover parts subjected to
misuse, abuse, improper handling or improper
installation. The GB warranty specifically excludes
any liability for indirect, incidental or consequential
damage to property.
Defective parts should be returned to your dealer or
to the factory prepaid with a copy of your sales
receipt. Defective parts will be repaired or replaced
at the factory’s option and returned to you prepaid.
GOLDEN BLOUNT
4301 WESTGROVE DRIVE
ADDISON, TX 75001
6/22/2018