Loading...
HomeMy WebLinkAboutFile Documents.210 E Cooper Ave.0205.2018.ARBKDESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED TITLE SHEET 1.1 12/08/2017PERMIT SET 210 COOPER-UNIT 1G 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED GENERAL INFORMATION 1.2 12/08/2017PERMIT SET 1. The Contract Documents include: (1) general notes; (2) architectural, mechanical, and structural drawings. All additional specifications, details, drawings, clarifications, or changes shall automatically become part of the Contract Documents. Any discrepancy between any components of any of the drawings shall be reported to the Architect immediately for clarification. 2. Alius Design Corps, LLC, shall not be liable in any way for problems which arise from failure, by any third party or any party to this Contract, to follow the design plans. The Contractor shall obtain and/or request guidance of Alius Design Corp., with respect to any errors, omissions, inconsistencies, or conflicts or unclear information which may be discovered or alleged. 3. The Plans and Specifications are the intellectual and other property of the Architect and shall not beused without the permission of same. 4. All work shall comply with all state and local codes, ordinances, rules, regulations and laws of building officials or authorities having jurisdiction. All work shall be performed to the highest standards or craftsmanship by all tradesman. Alius Design Corps, LLC., shall not be responsible for overseeing third party work, nor shall Alius Design Corps, LLC., be liable for any errors or omissions of third parties who perform work on the Project. 5. The Contract Documents represent the finished structure. They do not indicate the method of construction. The Contractor shall provide all measures necessary to protect the structure during construction. Observation visits to the site by the Structural Engineer or Architect shall not include inspection of the ____________, nor will the architect or structural engineer be responsible for the contractor's means, methods, techniques, sequences for procedure of construction, or the safety precautions and the techniques, sequences for procedure of construction, or any safety precautions. The Contractor and not the Architect shall be responsible for all Federal and OSHA regulations. 6. THE DRAWINGS ARE NOT TO BE SCALED. Written dimensions must be used. In the event of a discrepancy in dimensions, the Architect should be timely notified for clarification. All dimensions on the drawings shall be verified against the existing conditions. All dimensions are to rough framing or face of concrete unless noted otherwise. 7. The Construction Documents are intended to include all labor, materials, equipment, and services required to complete all work described herein. It is the responsibility of the Contractor to bring to the attention of the Architect any conditions which will not permit construction according to these Construction Documents. 8. The Building Inspector shall be notified by the Contractor if there is need of an inspection as required by the I.R.C., or by any local code or ordinance. 9. LOT STAKED: The Contractor shall arrange for the building to be located and staked after demolition or site clearing, to be approved by the Architect. The Contractor shall review the lot staking and verify, to the best of his ability, its accuracy. The Contractor shall also check the grade where it meets the building to evaluate the consistency with the drawings during excavation. All work to be done by a certified surveyor. 10. RECORD DRAWINGS: Contractor shall maintain a complete set of blue/black-line prints of contract drawings and shop drawings for record mark-up purposes throughout the Contract time. Mark-up drawings during course of the work shall show changes and actual installation conditions, sufficient to form a complete record for Owner's purposes. 11. SOILS AND CONCRETE: The General Contractor shall arrange for a visual site inspection at the completion of excavation by a soils engineer, and the required concrete testing prior to any foundation work. 12. Property lines, utilities and topography shown is representative of information taken from a survey. Contractor shall notify Architect of any discrepancy or variation between the Drawings and actual site conditions. ABREVIATIONS A.F.F. ABOVE FINISH FLOOR ADJ. ADJUSTABLE ALT. ALTERNATE A.B. ANCHOR BOLTS & AND ARCH. ARCHITECTURAL @ AT BM. BEAM BM. PKT. BEAM POCKET BRG. BEARING BLK’G. BLOCKING BOT. BOTTOM BLDG. BUILDING B.O. BY OWNER CLG. CEILING CL. CENTER LINE CLR. CLEAR COL. COLUMN CONC. CONCRETE CONN. CONNECTION CONT. CONTINUOUS DTL. DETAILS DWL. DOWEL E.W. EACH WAY ELEV. ELEVATION EXISTG EXISTING EXT. EXTERIOR FLR. FLOOR FTG. FOOTING FND. FOUNDATION GA. GAUGE G.L. GLU-LAM G.W.B. GYPSUM WALL BOARD HORIZ. HORIZONTAL INFO. INFORMATION INSUL. INSULATION JST. JOIST N.I.C. NOT IN CONTRACT O.C. ON CENTER OPP. OPPOSITE PERF. PERFORATED PL. PLATE PLY. PLYWOOD PROP. LINE PROPERTY LINE REINF. REINFORCEMENT REQ. REQUIRED REV. REVISED SIM. SIMILAR S.F. SQUARE FEET STD. STANDARD THK. THICK T.P. TOP OF PLATE T.L. TOP OF LEDGE T.W. TOP OF WALL TOT. TOTAL TYP. TYPICAL U.N.O. UNLESS NOTED UTHERWISE V.I.F. VERIFY IN FIELD 033 LBB GENERAL RENOVATION NOTES 1.0 All existing conditions must be verified by the contractor in the field. Unknown and varied conditions may be found. Notify the structural engineer and/or architect of any structural or architectural conditions found to vary from that indicated from the drawings. Design revisions may be required, and are to be expected as a process of remodel work. 2.0 All new work, details, surfaces, or finishes shall match adjacent existing surfaces unless noted or directed otherwise by the owner or interior designer. Contractor to verify with architect any conflict between existing and new conditions. 3.0 All electrical modifications and/or additions to be as directed by owner/lighting designer during construction. Contractor/lighting designer to verify electrical capacity and review new designs or alterations with architect, prior to implementation. 4.0 All interior electrical fixtures, plumbing fixtures and trim, cabinet design, and other finishes to be at the directive of the owner or interior designer unless noted otherwise in the drawings. Contractor to provide all necessary prep work for installation of any materials as required. 5.0 Structural engineering – if any modifications to the existing structural system are deemed necessary beyond these shown in the drawings, all existing conditions are to be verified in the field by a registered structural engineer before proceeding. The architect will not be responsible for any structural modifications not verified or approved by a structural engineer. 6.0 Contractor will verify and coordinate all openings through floors, ceilings, and walls with all architectural, structural, mechanical, plumbing, and electrical design and construction. CLIENT David and Kim Rainbolt OK Hopkins LLC Aspen, CO 81611 ARCHITECT Alius Design Corps, LLC 1331 East Sopris Creek Rd. Basalt, CO 81611 719.331.9211 michael@aliusdc.com GENERAL CONTRACTOR S&S Construction PO Box 2526 Aspen CO 81612 970-618-7318 phone 970-544-1738 fax scott@snsaspen.com 1. Not less than 75% of all permanently installed lighting fixtures shall contain only high-efficacy lamps per 2015 IECC Section R404.1. All recessed luminaries installed in the thermal envelope shall be IC rated and air sealed. 2. All plumbing fixtures that can gravity drain to the main waste line shall do so. Only those fixtures located in elevation below the main waste line may flow to the lift station in the lower level. 3. Alius Design Corps LLC. shall not be liable in any way for problems which arise from failure, by any third party or any party to this Contract, to follow the design plans. The Contractor shall obtain and/or request guidance of Alius Design Corps LLC., with respect to any errors, omissions, inconsistencies, or conflicts or unclear information which may be discovered or alleged. 4. The Plans and Specifications are the intellectual and other property of the Architect and shall not be used without the permission of same. 5. All work shall comply with all state and local codes, ordinances, rules, regulations and laws of building officials or authorities having jurisdiction. All work shall be performed to the highest standards or craftsmanship by all tradesman. Alius Design Corp s LLC., shall not be responsible for overseeing third party work, nor shall Alius Design Corps LLC., be liable for any errors or omissions of third parties who perform work on the Project. 6. The Contract Documents represent the finished structure. They do not indicate the method of construction. The Contractor shall provide all measures necessary to protect the structure during construction. Observation visits to the site by the Structural Engineer or Architect shall not include inspection of the ____________, nor will the architect or structural engineer be responsible for the contractor's means, methods, techniques, sequences for procedure of construction, or the safety precautions and the techniques, sequences for procedure of construction, or any safety precautions. The Contractor and not the Architect shall be responsible for all Federal and OSHA regulations. 7. THE DRAWINGS ARE NOT TO BE SCALED. Written dimensions must be used. In the event of a discrepancy in dimensions, the Architect should be timely notified for clarification. All dimensions on the drawings shall be verified against the existing conditions. All dimensions are to rough framing or face of concrete unless noted otherwise. 8. The Construction Documents are intended to include all labor, materials, equipment, and services required to complete all work described herein. It is the responsibility of the Contractor to bring to the attention of the Architect any conditions which will not permit construction according to these Construction Documents. 9. The Building Inspector shall be notified by the Contractor if there is need of an inspection as required by the I.R.C., or by any local code or ordinance. 10. LOT STAKED: The Contractor shall arrange for the building to be located and staked after demolition or site clearing, to be approved by the Architect. The Contractor shall review the lot staking and verify, to the best of his ability, its accuracy. The Contractor shall also check the grade where it meets the building to evaluate the consistency with the drawings during excavation. All work to be done by a certified surveyor. ARCHITECTURAL 1.1 TITLE SHEET 1.2 GENERAL INFORMATION 1.3 UNIT BUILDING RELATIONSHIP 1.4 RECORDED PLAT 1.5 FLOOR PLAN AND PLAT COMPARISON 3.1 FLOOR PLANS 3.2 FLOOR PLANS 7.1 ASSEMBLIES AND DETAILS 5.1A REFERENCE GRID LINE SPOT ELEVATION WINDOW MARK DOOR MARK ROOM NUMBER DRAWING REVISION ASSEMBLY DETAIL CUT SECTION CUT EXTERIOR ELEVATION DETAIL CALLOUT INTERIOR ELEVATION ROOM 100 F11 1 T. O. RIDGE BEAM 123'-6 1/2" 4.4 1 1 7.1 8.1 1 2 3 4 SYMBOL & MATERIAL LEGEND PROJECT INFORMATION DRAWING INDEX PROJECT DIRECTORY CONSTRUCTION NOTES ABBREVIATIONS PERMIT SET_120817GENERAL NOTES 210 COOPER-UNIT 1G N/A GENERAL CODE NOTES 8 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED UNIT BUILDING RELATIONSHIP 1.3 12/08/2017PERMIT SET 210 E. COOPER PROJECT SITE, 1ST FLOOR 1 BUILDING UNIT RELATIONSHIP 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED RECORDED PLAT 1.4 12/08/2017PERMIT SET 0 1''2''4''SCALE: 6" = 1'-0"2 Cooper Condo Plat 0 1''2''4''SCALE: 6" = 1'-0"1 Cooper Condo Plat UNIT 1 -G 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED FLOOR PLAN AND PLAT COMPARISON 1.5 12/08/2017PERMIT SET 3 3 AA 1 2 2F BBDWWD4'-2" 21'-1" 5.2 EXIST. WOOD BURNING FIREPLACE TO REMAIN; CORNER UNIT DEMO EXIST. WINDOWS AND EXTERIOR DOORS LINE OF CABINETS ABOVE DASHED LINE OF WALL ABOVE KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 CLOSET109 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 0 1''2''4''SCALE: 6" = 1'-0"1 Cooper Condo Plat 0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - EXISTINGUNI T 1 -G08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED ZONING DEMO CALCULATIONS 1.6 12/08/2017PERMIT SET KITCHEN 103 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE EXIST. SIDING TO REMAINEXIST. WINDOW TYP. NEW PROPOSED WINDOW EXISTING SURFACE AREA: 1,586 SQ.FT. SURFACE AREA REDUCED BY NEW WINDOWS: 18 SQ.FT. NEW SURFACE AREA WALL: 1,568 SQ.FT. 0 4'8'16'SCALE: 1/8" = 1'-0"1 REFERENCE PLAN 0 2'4'8'SCALE: 1/4" = 1'-0"2 EAST ELEVATION EAST ELEVATION 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED FLOOR PLANS EXISTING/DEMO 3.1 12/08/2017PERMIT SET 3 3 AA 1 2 2F BBDWWD4'-2" 21'-1" EXIST. WOOD BURNING FIREPLACE TO REMAIN; CORNER UNIT DEMO EXIST. WINDOWS AND EXTERIOR DOORS LINE OF CABINETS ABOVE DASHED LINE OF WALL ABOVE KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 CLOSET109 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 3 3 AA 1 2 2F BBDWWD4'-2" 21'-1" KEEP EXISTING WOOD BURNING FIREPLACE - LOWER TO FLOOR REMOVE PLUMBING FIXTURES TYP. REMOVE EXISTING WASHER/DRYER DEMO KITCHEN AND CABINETRY DEMO EXISTING CLOSET AND DOORS KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 CLOSET109 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - EXISTING 0 2'4'8'SCALE: 1/4" = 1'-0"2 FLOOR PLAN - DEMOLITION ***WALLS SHOWN AS DEMOLISHED ARE NON-STRUCTURAL. CONTRACTOR TO REMOVE DRYWALL AND ALLOW ARCHITECT VISUAL INSPECTION PRIOR TO REMOVING WALL FRAMING*** 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED FLOOR PLANS NEW/FURNITURE 3.2 12/08/2017PERMIT SET FDW6" x 48" PORCELAIN TILE; WOOD FINISH NEW CARPET LINE OF NEW STEEL HEADER ABOVE NEW FLUSH HEARTH EXTENSION W/D KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 3 3 AA 1 2 2 BBFDW2'-81/2"31/2"3'-9"2'-6"2'-9"2'-9"2'-6"1'-3"3'-2"1'-7"2'-4" 3'-6" 5.2 OPEN SKI STORAGE NEW FIXTURES; MATCH EXIST. LOCATIONS KEEP EXISTING WOOD BURNING FIREPLACE REPLACE WINDOWS W/ NO MULLIONS SAME SIZE BENCH W/ CUBBIES MILLWORK CLOSET NEW LINEAR DRAIN ADD NEW WINDOW NEW ENTRY DOOR SEE ASSEMBLY W2 ON SHEET 7.1 FOR FIRE RATED CONNECTION ASSEMBLY W/D KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 1 28.1 6 8.15 8.1 3 4 78.1 68.2 7 5 8 108.2 11 9 12 28.2 3 1 4 0 2'4'8'SCALE: 1/4" = 1'-0"1 FURNITURE PLAN 0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - NEW 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED FLOOR PLAN RCP 3.3 12/08/2017PERMIT SET 3 3 AA 1 2 2 BB COSD SD CO SD CO BATHROOM LIGHTING TO REMAIN EXIST. EXHAUST FANS TO REMAIN TYP. W/D W W KITCHEN 103 BEDROOM105 LIVING AREA102 ENTRY101 BATHROOM106 MASTERBATHROOM108 MASTERBEDROOM107 MECH104 EXTERIORWALKWAY ADJACENT UNITOUTSIDE OFSCOPE 0 2'4'8'SCALE: 1/4" = 1'-0"1 MAIN LEVEL R.C.P. 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED WALL ASSEMBLIES & DETAILS 7.1 12/08/2017PERMIT SET 5/8"SEE PLAN 5/8" 5/8"SEE PLAN 5/8" 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH - SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 5/8" GYPSUM WALL BOARD OR OTHER INTERIOR FINISH - SEE SCHEDULE 5/8" TYPE 'X' GYPSUM WALL BOARD OR OTHER INTERIOR FINISH - SEE SCHEDULE WALL FRAMING W/ BLOCKING AS REQUIRED SOUND ATTENUATING INSULATION - REFER TO SPECS 1 ½" = 1'-0" INTERIOR WALL (TYPICAL)W1 GL 1 ½" = 1'-0" 1 HR FIRE RATED INTERIOR WALLW2 GL UL SYSTEM DESIGN U314 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED INTERIOR ELEVATIONS 8.1 12/08/2017PERMIT SET2'-81/2"11/2"2'-61/2"2'-41/2"3'-0"7'-9"11/2"5'-0"11/2"3'-03/4"1'-4"4"3'-03/4"3'-11/2" 5'-3"1'-3"3'-2"1'-7" 4'-2"3'-5"4'-6"1'-3"1'-6"3'-31/2"1"8"1'-11"31/2"9'-0" 17.2 WOOD PANEL AT CLOSET EXISTING WOOD FIREPLACE RAISED TO 20" WOOD DOORS W/ PAINTED WOOD TRIM NEW WINDOWS NO MULLIONS NEW STONE VENEER 3CM STONE WATERFALL EDGE WOOD VENEER PANELS 3CM STONE WATERFALL EDGE 3CM STONE WATERFALL EDGE EXISTING WINDOW TO REMAIN WOOD VENEER PANELS PAINTED GYP BOARD; SEE FINISH SCHEDULE WOOD PANEL BACK WOOD FACED CABINETS TO CEILING NEW 6" PAINTED WOOD BASE CONCEALED DOOR STONE BACKSPLACH; SEE SCHEDULE CORNER CABINET NEW 6" PAINTED WOOD BASE PAINTED GYP BOARD; SEE FINISH SCHEDULE 3CM STONE WATERFALL EDGE LED STRIP LIGHTING WOOD PANEL BACK OPEN FOR BOOTS BELOW WOOD FACED DRAWERS; DEPTH VARIES WOOD FACED CONCEALED RANGE HOOD; SEE SPECS STEEL ANGLE MANTEL NEW STONE VENEER BEHIND TV TV OPEN TO HALL KITCHEN ELEVATION2SCALE: 1/2"=1'-0" LIVING ROOM/HALL1SCALE: 1/2"=1'-0" KITCHEN ELEVATION3SCALE: 1/2"=1'-0" LIVING ROOM8SCALE: 1/2"=1'-0" KITCHEN ISLAND4SCALE: 1/2"=1'-0" KITCHEN ISLAND5SCALE: 1/2"=1'-0" KITCHEN ISLAND6SCALE: 1/2"=1'-0" KITCHEN ISLAND7SCALE: 1/2"=1'-0" 08/01/2018 DESIGN CORPS ALIUS DESIGN CORPS ALIUS ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE 1708 ISSUE PROJECT No: DRAWN BY: DRAWING SET COPYRIGHT 2017 ALIUS DESIGN CORPS LLC. ALL RIGHTS RESERVED INTERIOR ELEVATIONS 8.2 12/08/2017PERMIT SET 7'-3" 7'-5"2'-0"1'-0"4'-6"6"4" EQ EQ 4'-6"EQ EQ 4'-6"EQEQ 2'-0"1'-0"1'-3"1'-3"7'-9"1'-3"12'-7"7'-9"7'-10" 18" TOWEL BAR NEW MIRROR BY. I.D. NEW SCONCE BY I.D. PAINTED GYP BOARD GFI OUTLET NEW VANITY SAME LOCATION; SEE PLUMBING SCHEDULE NEW TOILET SAME LOCATION; SEE PLUMBING SCHEDULE NEW 6" BASE NEW TILE; SEE SCHEDULE ROUGH OUT FOR SHOWER HEAD; SEE PLUMBING SCHEDULE NEW DIVERTER/BALANCE VALVE HAND SHOWER BALANCE/PRESSURE VALVE; SEE PLUMBING SCHEDULE NEW TILE; SEE SCHEDULE NEW TUB SAME LOCATION; SEE PLUMBING SCHEDULE NEW DIVERTER SAME LOCATION; SEE PLUMBING SCHEDULE NEW TILE; SEE SCHEDULE NEW SHOWER HEAD SAME LOCATION; SEE PLUMBING SCHEDULE NEW SCONCE SEE SCHEDULE NEW MIRROR SEE SCHEDULE PAINTED GYP BOARD GFI OUTLET NEW VANITY SAME LOCATION; SEE PLUMBING SCHEDULE NEW TOILET SAME LOCATION; SEE PLUMBING SCHEDULE NEW 6" BASE 18" TOWEL BAR NEW TILE; SEE FINISH SCHEDULE WALL TO WALL NICHE NEW STONE BENCH NEW 6" PAINTED WOOD BASE PAINTED GYP BOARD; SEE FINISH SCHEDULE NEW 6" PAINTED WOOD BASE PAINTED GYP BOARD; SEE FINISH SCHEDULE NEW 6" PAINTED WOOD BASE PAINTED GYP BOARD; SEE FINISH SCHEDULE NEW 6" PAINTED WOOD BASE PAINTED GYP BOARD; SEE FINISH SCHEDULE REAPLACE WINDOWS W/MULLIONS WOOD DOORS W/ PAINTED WOOD TRIM WOOD DOORS W/ PAINTED WOOD TRIM WOOD DOORS W/ PAINTED WOOD TRIM T.P. HOLDER CL CLCLCL CL T.P. HOLDER TV MASTER BEDRDOOM1SCALE: 1/2"=1'-0" MASTER BEDROOM2SCALE: 1/2"=1'-0" MASTER BEDRDOOM3SCALE: 1/2"=1'-0" MASTER BEDROOM4SCALE: 1/2"=1'-0" BATHROOM ELEVATION5SCALE: 1/2"=1'-0" BATHROOM ELEVATION6SCALE: 1/2"=1'-0" BATHROOM ELEVATION7SCALE: 1/2"=1'-0" BATHROOM ELEVATION8SCALE: 1/2"=1'-0" MASTER BATHROOM9SCALE: 1/2"=1'-0" MASTER BATHROOM10SCALE: 1/2"=1'-0" MASTER BATHROOM11SCALE: 1/2"=1'-0" MASTER BATHROOM12SCALE: 1/2"=1'-0" 08/01/2018