HomeMy WebLinkAboutFile Documents.210 E Cooper Ave.0205.2018.ARBKDESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
TITLE SHEET
1.1
12/08/2017PERMIT SET
210 COOPER-UNIT 1G
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
GENERAL
INFORMATION
1.2
12/08/2017PERMIT SET
1. The Contract Documents include: (1) general notes; (2) architectural, mechanical, and structural drawings. All additional specifications, details, drawings,
clarifications, or changes shall automatically become part of the Contract Documents. Any discrepancy between any components of any of the drawings shall
be reported to the Architect immediately for clarification.
2. Alius Design Corps, LLC, shall not be liable in any way for problems which arise from failure, by any third party or any party to this Contract, to follow the
design plans. The Contractor shall obtain and/or request guidance of Alius Design Corp., with respect to any errors, omissions, inconsistencies, or conflicts or
unclear information which may be discovered or alleged.
3. The Plans and Specifications are the intellectual and other property of the Architect and shall not beused without the permission of same.
4. All work shall comply with all state and local codes, ordinances, rules, regulations and laws of building officials or authorities having jurisdiction. All work shall
be performed to the highest standards or craftsmanship by all tradesman. Alius Design Corps, LLC., shall not be responsible for overseeing third party work,
nor shall Alius Design Corps, LLC., be liable for any errors or omissions of third parties who perform work on the Project.
5. The Contract Documents represent the finished structure. They do not indicate the method of construction. The Contractor shall provide all measures
necessary to protect the structure during construction. Observation visits to the site by the Structural Engineer or Architect shall not include inspection of the
____________, nor will the architect or structural engineer be responsible for the contractor's means, methods, techniques, sequences for procedure of
construction, or the safety precautions and the techniques, sequences for procedure of construction, or any safety precautions. The Contractor and not the
Architect shall be responsible for all Federal and OSHA regulations.
6. THE DRAWINGS ARE NOT TO BE SCALED. Written dimensions must be used. In the event of a discrepancy in dimensions, the Architect should be timely
notified for clarification. All dimensions on the drawings shall be verified against the existing conditions. All dimensions are to rough framing or face of
concrete unless noted otherwise.
7. The Construction Documents are intended to include all labor, materials, equipment, and services required to complete all work described herein. It is the
responsibility of the Contractor to bring to the attention of the Architect any conditions which will not permit construction according to these Construction
Documents.
8. The Building Inspector shall be notified by the Contractor if there is need of an inspection as required by the I.R.C., or by any local code or ordinance.
9. LOT STAKED: The Contractor shall arrange for the building to be located and staked after demolition or site clearing, to be approved by the Architect. The
Contractor shall review the lot staking and verify, to the best of his ability, its accuracy. The Contractor shall also check the grade where it meets the building
to evaluate the consistency with the drawings during excavation. All work to be done by a certified surveyor.
10. RECORD DRAWINGS: Contractor shall maintain a complete set of blue/black-line prints of contract drawings and shop drawings for record mark-up purposes
throughout the Contract time. Mark-up drawings during course of the work shall show changes and actual installation conditions, sufficient to form a complete
record for Owner's purposes.
11. SOILS AND CONCRETE: The General Contractor shall arrange for a visual site inspection at the completion of excavation by a soils engineer, and the
required concrete testing prior to any foundation work.
12. Property lines, utilities and topography shown is representative of information taken from a survey. Contractor shall notify Architect of any discrepancy or
variation between the Drawings and actual site conditions.
ABREVIATIONS
A.F.F. ABOVE FINISH FLOOR
ADJ. ADJUSTABLE
ALT. ALTERNATE
A.B. ANCHOR BOLTS
& AND
ARCH. ARCHITECTURAL
@ AT
BM. BEAM
BM. PKT. BEAM POCKET
BRG. BEARING
BLK’G. BLOCKING
BOT. BOTTOM
BLDG. BUILDING
B.O. BY OWNER
CLG. CEILING
CL. CENTER LINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONT. CONTINUOUS
DTL. DETAILS
DWL. DOWEL
E.W. EACH WAY
ELEV. ELEVATION
EXISTG EXISTING
EXT. EXTERIOR
FLR. FLOOR
FTG. FOOTING
FND. FOUNDATION
GA. GAUGE
G.L. GLU-LAM
G.W.B. GYPSUM WALL BOARD
HORIZ. HORIZONTAL
INFO. INFORMATION
INSUL. INSULATION
JST. JOIST
N.I.C. NOT IN CONTRACT
O.C. ON CENTER
OPP. OPPOSITE
PERF. PERFORATED
PL. PLATE
PLY. PLYWOOD
PROP. LINE PROPERTY LINE
REINF. REINFORCEMENT
REQ. REQUIRED
REV. REVISED
SIM. SIMILAR
S.F. SQUARE FEET
STD. STANDARD
THK. THICK
T.P. TOP OF PLATE
T.L. TOP OF LEDGE
T.W. TOP OF WALL
TOT. TOTAL
TYP. TYPICAL
U.N.O. UNLESS NOTED UTHERWISE
V.I.F. VERIFY IN FIELD
033
LBB
GENERAL RENOVATION NOTES
1.0 All existing conditions must be verified by the contractor in the field. Unknown and varied conditions may be found. Notify the structural engineer and/or architect of any
structural or architectural conditions found to vary from that indicated from the drawings. Design revisions may be required, and are to be expected as a process of remodel
work.
2.0 All new work, details, surfaces, or finishes shall match adjacent existing surfaces unless noted or directed otherwise by the owner or interior designer. Contractor to verify with
architect any conflict between existing and new conditions.
3.0 All electrical modifications and/or additions to be as directed by owner/lighting designer during construction. Contractor/lighting designer to verify electrical capacity and review
new designs or alterations with architect, prior to implementation.
4.0 All interior electrical fixtures, plumbing fixtures and trim, cabinet design, and other finishes to be at the directive of the owner or interior designer unless noted otherwise in the
drawings. Contractor to provide all necessary prep work for installation of any materials as required.
5.0 Structural engineering – if any modifications to the existing structural system are deemed necessary beyond these shown in the drawings, all existing conditions are to be verified
in the field by a registered structural engineer before proceeding. The architect will not be responsible for any structural modifications not verified or approved by a structural
engineer.
6.0 Contractor will verify and coordinate all openings through floors, ceilings, and walls with all architectural, structural, mechanical, plumbing, and electrical design and
construction.
CLIENT
David and Kim Rainbolt
OK Hopkins LLC
Aspen, CO 81611
ARCHITECT
Alius Design Corps, LLC
1331 East Sopris Creek Rd.
Basalt, CO 81611
719.331.9211
michael@aliusdc.com
GENERAL CONTRACTOR
S&S Construction
PO Box 2526
Aspen CO 81612
970-618-7318 phone
970-544-1738 fax
scott@snsaspen.com
1. Not less than 75% of all permanently installed lighting fixtures shall contain only high-efficacy lamps per 2015 IECC Section R404.1. All
recessed luminaries installed in the thermal envelope shall be IC rated and air sealed.
2. All plumbing fixtures that can gravity drain to the main waste line shall do so. Only those fixtures located in elevation below the main waste line
may flow to the lift station in the lower level.
3. Alius Design Corps LLC. shall not be liable in any way for problems which arise from failure, by any third party or any party to this Contract, to
follow the design plans. The Contractor shall obtain and/or request guidance of Alius Design Corps LLC., with respect to any errors,
omissions, inconsistencies, or conflicts or unclear information which may be discovered or alleged.
4. The Plans and Specifications are the intellectual and other property of the Architect and shall not be used without the permission of same.
5. All work shall comply with all state and local codes, ordinances, rules, regulations and laws of building officials or authorities having
jurisdiction. All work shall be performed to the highest standards or craftsmanship by all tradesman. Alius Design Corp s LLC., shall not be
responsible for overseeing third party work, nor shall Alius Design Corps LLC., be liable for any errors or omissions of third parties who perform
work on the Project.
6. The Contract Documents represent the finished structure. They do not indicate the method of construction. The Contractor shall provide all
measures necessary to protect the structure during construction. Observation visits to the site by the Structural Engineer or Architect shall not
include inspection of the ____________, nor will the architect or structural engineer be responsible for the contractor's means, methods,
techniques, sequences for procedure of construction, or the safety precautions and the techniques, sequences for procedure of construction,
or any safety precautions. The Contractor and not the Architect shall be responsible for all Federal and OSHA regulations.
7. THE DRAWINGS ARE NOT TO BE SCALED. Written dimensions must be used. In the event of a discrepancy in dimensions, the Architect
should be timely notified for clarification. All dimensions on the drawings shall be verified against the existing conditions. All dimensions are to
rough framing or face of concrete unless noted otherwise.
8. The Construction Documents are intended to include all labor, materials, equipment, and services required to complete all work described
herein. It is the responsibility of the Contractor to bring to the attention of the Architect any conditions which will not permit construction
according to these Construction Documents.
9. The Building Inspector shall be notified by the Contractor if there is need of an inspection as required by the I.R.C., or by any local code or
ordinance.
10. LOT STAKED: The Contractor shall arrange for the building to be located and staked after demolition or site clearing, to be approved by the
Architect. The Contractor shall review the lot staking and verify, to the best of his ability, its accuracy. The Contractor shall also check the
grade where it meets the building to evaluate the consistency with the drawings during excavation. All work to be done by a certified surveyor.
ARCHITECTURAL
1.1 TITLE SHEET
1.2 GENERAL INFORMATION
1.3 UNIT BUILDING RELATIONSHIP
1.4 RECORDED PLAT
1.5 FLOOR PLAN AND PLAT COMPARISON
3.1 FLOOR PLANS
3.2 FLOOR PLANS
7.1 ASSEMBLIES AND DETAILS
5.1A
REFERENCE GRID LINE
SPOT ELEVATION
WINDOW MARK
DOOR MARK
ROOM NUMBER
DRAWING REVISION
ASSEMBLY DETAIL CUT
SECTION CUT
EXTERIOR ELEVATION
DETAIL CALLOUT
INTERIOR ELEVATION
ROOM
100
F11
1
T. O. RIDGE
BEAM
123'-6 1/2"
4.4
1
1
7.1
8.1
1
2
3
4
SYMBOL & MATERIAL LEGEND
PROJECT INFORMATION
DRAWING INDEX
PROJECT DIRECTORY
CONSTRUCTION NOTES
ABBREVIATIONS
PERMIT SET_120817GENERAL NOTES
210 COOPER-UNIT 1G
N/A
GENERAL CODE NOTES
8
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
UNIT BUILDING
RELATIONSHIP
1.3
12/08/2017PERMIT SET
210 E. COOPER
PROJECT SITE, 1ST FLOOR
1 BUILDING UNIT RELATIONSHIP
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
RECORDED PLAT
1.4
12/08/2017PERMIT SET
0 1''2''4''SCALE: 6" = 1'-0"2 Cooper Condo Plat
0 1''2''4''SCALE: 6" = 1'-0"1 Cooper Condo Plat
UNIT 1 -G
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
FLOOR PLAN AND
PLAT COMPARISON
1.5
12/08/2017PERMIT SET
3
3
AA
1
2
2F BBDWWD4'-2"
21'-1"
5.2
EXIST. WOOD BURNING
FIREPLACE TO REMAIN;
CORNER UNIT
DEMO EXIST. WINDOWS AND
EXTERIOR DOORS
LINE OF CABINETS
ABOVE
DASHED LINE OF WALL
ABOVE
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
CLOSET109
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
0 1''2''4''SCALE: 6" = 1'-0"1 Cooper Condo Plat
0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - EXISTINGUNI
T
1
-G08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
ZONING DEMO
CALCULATIONS
1.6
12/08/2017PERMIT SET
KITCHEN
103
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
EXIST. SIDING TO REMAINEXIST. WINDOW TYP.
NEW PROPOSED WINDOW
EXISTING SURFACE AREA: 1,586 SQ.FT.
SURFACE AREA REDUCED BY NEW WINDOWS: 18 SQ.FT.
NEW SURFACE AREA WALL: 1,568 SQ.FT.
0 4'8'16'SCALE: 1/8" = 1'-0"1 REFERENCE PLAN
0 2'4'8'SCALE: 1/4" = 1'-0"2 EAST ELEVATION
EAST ELEVATION
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
FLOOR PLANS
EXISTING/DEMO
3.1
12/08/2017PERMIT SET
3
3
AA
1
2
2F BBDWWD4'-2"
21'-1"
EXIST. WOOD BURNING
FIREPLACE TO REMAIN;
CORNER UNIT
DEMO EXIST. WINDOWS AND
EXTERIOR DOORS
LINE OF CABINETS
ABOVE
DASHED LINE OF WALL
ABOVE
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
CLOSET109
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
3
3
AA
1
2
2F BBDWWD4'-2"
21'-1"
KEEP EXISTING WOOD BURNING
FIREPLACE - LOWER TO FLOOR
REMOVE PLUMBING FIXTURES TYP.
REMOVE EXISTING WASHER/DRYER
DEMO KITCHEN AND CABINETRY
DEMO EXISTING CLOSET AND DOORS
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
CLOSET109
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - EXISTING
0 2'4'8'SCALE: 1/4" = 1'-0"2 FLOOR PLAN - DEMOLITION
***WALLS SHOWN AS DEMOLISHED ARE NON-STRUCTURAL. CONTRACTOR TO REMOVE DRYWALL
AND ALLOW ARCHITECT VISUAL INSPECTION PRIOR TO REMOVING WALL FRAMING***
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
FLOOR PLANS
NEW/FURNITURE
3.2
12/08/2017PERMIT SET
FDW6" x 48" PORCELAIN TILE;
WOOD FINISH
NEW CARPET
LINE OF NEW STEEL
HEADER ABOVE
NEW FLUSH
HEARTH EXTENSION
W/D
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
3
3
AA
1
2
2
BBFDW2'-81/2"31/2"3'-9"2'-6"2'-9"2'-9"2'-6"1'-3"3'-2"1'-7"2'-4"
3'-6"
5.2
OPEN SKI STORAGE
NEW FIXTURES; MATCH EXIST.
LOCATIONS
KEEP EXISTING WOOD
BURNING FIREPLACE
REPLACE WINDOWS W/ NO
MULLIONS SAME SIZE
BENCH W/ CUBBIES
MILLWORK CLOSET
NEW LINEAR DRAIN
ADD NEW WINDOW
NEW ENTRY DOOR
SEE ASSEMBLY W2
ON SHEET 7.1 FOR FIRE
RATED CONNECTION
ASSEMBLY
W/D
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
1
28.1
6
8.15
8.1
3
4
78.1
68.2
7
5
8 108.2
11
9
12
28.2
3
1
4
0 2'4'8'SCALE: 1/4" = 1'-0"1 FURNITURE PLAN
0 2'4'8'SCALE: 1/4" = 1'-0"1 FLOOR PLAN - NEW
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
FLOOR PLAN RCP
3.3
12/08/2017PERMIT SET
3
3
AA
1
2
2
BB
COSD
SD CO
SD CO
BATHROOM LIGHTING TO
REMAIN EXIST. EXHAUST FANS TO REMAIN TYP.
W/D
W W
KITCHEN
103
BEDROOM105
LIVING AREA102
ENTRY101 BATHROOM106 MASTERBATHROOM108
MASTERBEDROOM107
MECH104
EXTERIORWALKWAY
ADJACENT UNITOUTSIDE OFSCOPE
0 2'4'8'SCALE: 1/4" = 1'-0"1 MAIN LEVEL R.C.P.
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
WALL ASSEMBLIES &
DETAILS
7.1
12/08/2017PERMIT SET
5/8"SEE PLAN 5/8"
5/8"SEE PLAN 5/8"
5/8" GYPSUM WALL BOARD OR OTHER INTERIOR
FINISH - SEE SCHEDULE
WALL FRAMING W/ BLOCKING AS REQUIRED
SOUND ATTENUATING INSULATION - REFER TO
SPECS
5/8" GYPSUM WALL BOARD OR OTHER INTERIOR
FINISH - SEE SCHEDULE
5/8" TYPE 'X' GYPSUM WALL BOARD OR OTHER
INTERIOR FINISH - SEE SCHEDULE
WALL FRAMING W/ BLOCKING AS REQUIRED
SOUND ATTENUATING INSULATION - REFER TO
SPECS
1 ½" = 1'-0"
INTERIOR WALL (TYPICAL)W1
GL
1 ½" = 1'-0"
1 HR FIRE RATED INTERIOR WALLW2
GL
UL SYSTEM DESIGN U314
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
INTERIOR ELEVATIONS
8.1
12/08/2017PERMIT SET2'-81/2"11/2"2'-61/2"2'-41/2"3'-0"7'-9"11/2"5'-0"11/2"3'-03/4"1'-4"4"3'-03/4"3'-11/2"
5'-3"1'-3"3'-2"1'-7"
4'-2"3'-5"4'-6"1'-3"1'-6"3'-31/2"1"8"1'-11"31/2"9'-0"
17.2
WOOD PANEL AT CLOSET
EXISTING WOOD FIREPLACE
RAISED TO 20"
WOOD DOORS W/ PAINTED
WOOD TRIM
NEW WINDOWS NO
MULLIONS
NEW STONE VENEER
3CM STONE
WATERFALL EDGE
WOOD VENEER
PANELS
3CM STONE
WATERFALL EDGE
3CM STONE
WATERFALL EDGE
EXISTING WINDOW
TO REMAIN
WOOD VENEER
PANELS
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
WOOD PANEL BACK
WOOD FACED
CABINETS TO CEILING
NEW 6" PAINTED WOOD BASE
CONCEALED DOOR
STONE BACKSPLACH;
SEE SCHEDULE
CORNER CABINET NEW 6" PAINTED WOOD BASE
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
3CM STONE
WATERFALL EDGE
LED STRIP LIGHTING
WOOD PANEL BACK OPEN FOR
BOOTS BELOW
WOOD FACED DRAWERS;
DEPTH VARIES
WOOD FACED CONCEALED
RANGE HOOD; SEE SPECS
STEEL ANGLE MANTEL
NEW STONE VENEER
BEHIND TV
TV
OPEN TO HALL
KITCHEN ELEVATION2SCALE: 1/2"=1'-0"
LIVING ROOM/HALL1SCALE: 1/2"=1'-0"
KITCHEN ELEVATION3SCALE: 1/2"=1'-0"
LIVING ROOM8SCALE: 1/2"=1'-0"
KITCHEN ISLAND4SCALE: 1/2"=1'-0"
KITCHEN ISLAND5SCALE: 1/2"=1'-0"
KITCHEN ISLAND6SCALE: 1/2"=1'-0"
KITCHEN ISLAND7SCALE: 1/2"=1'-0"
08/01/2018
DESIGN CORPS
ALIUS
DESIGN CORPS
ALIUS
ASPEN, CO 81611210 COOPER-UNIT 1G UNIT 1GMTE
1708
ISSUE
PROJECT No:
DRAWN BY:
DRAWING SET
COPYRIGHT 2017 ALIUS DESIGN
CORPS LLC. ALL RIGHTS RESERVED
INTERIOR ELEVATIONS
8.2
12/08/2017PERMIT SET
7'-3"
7'-5"2'-0"1'-0"4'-6"6"4"
EQ EQ 4'-6"EQ EQ
4'-6"EQEQ
2'-0"1'-0"1'-3"1'-3"7'-9"1'-3"12'-7"7'-9"7'-10"
18" TOWEL BAR
NEW MIRROR BY. I.D.
NEW SCONCE BY I.D.
PAINTED GYP BOARD
GFI OUTLET
NEW VANITY SAME LOCATION; SEE
PLUMBING SCHEDULE
NEW TOILET SAME LOCATION;
SEE PLUMBING SCHEDULE
NEW 6" BASE
NEW TILE;
SEE SCHEDULE
ROUGH OUT FOR
SHOWER HEAD;
SEE PLUMBING SCHEDULE
NEW DIVERTER/BALANCE
VALVE
HAND SHOWER
BALANCE/PRESSURE VALVE;
SEE PLUMBING SCHEDULE
NEW TILE;
SEE SCHEDULE
NEW TUB SAME LOCATION;
SEE PLUMBING SCHEDULE
NEW DIVERTER SAME
LOCATION; SEE
PLUMBING SCHEDULE
NEW TILE;
SEE SCHEDULE
NEW SHOWER HEAD SAME
LOCATION; SEE PLUMBING
SCHEDULE
NEW SCONCE SEE SCHEDULE
NEW MIRROR SEE SCHEDULE
PAINTED GYP BOARD
GFI OUTLET
NEW VANITY SAME LOCATION; SEE
PLUMBING SCHEDULE
NEW TOILET SAME LOCATION;
SEE PLUMBING SCHEDULE
NEW 6" BASE
18" TOWEL BAR
NEW TILE; SEE FINISH SCHEDULE
WALL TO WALL NICHE
NEW STONE BENCH
NEW 6" PAINTED WOOD BASE
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
NEW 6" PAINTED WOOD BASE
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
NEW 6" PAINTED WOOD BASE
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
NEW 6" PAINTED WOOD BASE
PAINTED GYP BOARD;
SEE FINISH SCHEDULE
REAPLACE WINDOWS W/MULLIONS
WOOD DOORS W/
PAINTED WOOD TRIM
WOOD DOORS W/
PAINTED WOOD TRIM
WOOD DOORS W/
PAINTED WOOD TRIM
T.P.
HOLDER
CL
CLCLCL
CL
T.P.
HOLDER
TV
MASTER BEDRDOOM1SCALE: 1/2"=1'-0"
MASTER BEDROOM2SCALE: 1/2"=1'-0"
MASTER BEDRDOOM3SCALE: 1/2"=1'-0"
MASTER BEDROOM4SCALE: 1/2"=1'-0"
BATHROOM ELEVATION5SCALE: 1/2"=1'-0"
BATHROOM ELEVATION6SCALE: 1/2"=1'-0"
BATHROOM ELEVATION7SCALE: 1/2"=1'-0"
BATHROOM ELEVATION8SCALE: 1/2"=1'-0"
MASTER BATHROOM9SCALE: 1/2"=1'-0"
MASTER BATHROOM10SCALE: 1/2"=1'-0"
MASTER BATHROOM11SCALE: 1/2"=1'-0"
MASTER BATHROOM12SCALE: 1/2"=1'-0"
08/01/2018