HomeMy WebLinkAboutFile Documents.210 E Cooper Ave.0181.2018 (11).ARBKNCB Series Combination Boilers Specification SheetCondensing Gas Combination Boiler Optional accessories (see below) NCB-150E NCB-180E NCB-210E NCB-240E NCB-150E - NCB-180E - NCB-210E NCB-240E Dual Primary and Secondary Stainless Steel Heat Exchangers Internal Circulation Pump AFUE NCB-150E/-180E/-210E/-240E CSA, ASME, NSF/ANSI 372 (DHW only) SCAQMD Natural Gas (NG)Propane (LPG) f Backlit Front Panel ANSI Z21.13 - CSA 4.9-2014 Temperature Options 77°F up to 194°F 86°F to 140°F Sleek Design - Compatible with 2“ PVC Vent INCLUDED Illuminated Front Panel with Advanced Hydronic and DHW Operation 2” PVC vent up to 60 ft** 3” PVC vent up to 150 ft** (** with no elbows) Outdoor Reset Sensor Stainless Steel Flat Plate Heat Exchanger*DHW Domestic Hot Water Priority Low Voltage Terminal Strip 10-Year 5-Year (**** see Navien Limited Residential Warranty) psiO/R CONDENSING COMBI BOILER NCB S R MODE Plumb Easy Valve Set (30010950A - 1” Standard) (30009323A - 3/4” Lead Free) (30012581A - 3/4” for Pipe Cover) Ready-Link Cascade Communication Cable (GXXX000546) SmartZone+ Pump Controller (PFMZ-02P-001 - For 2 Zones) (PFMZ-03P-001 - For 3 Zones) (PFMZ-04P-001 - For 4 Zones) (PFMZ-06P-001 - For 6 Zones) NCB Primary Manifold (GFFM-MCOZUS-001) For 3/4” Valves Only Condensate Neutralizer (GXXX001322 - Single Unit) (GXXX001324 - Up to 6 Units) (GXXX001325 - Up to 16 Units) H Certified to NSF/ANSI 372 Ready-Link Cascade Compatibility up to 15 tankless water heaters 7 CRN - NCB-150E NCB-180E NCB-210E NCB-240E NaviLink Wi-Fi Control (PBCM-AS-001) TM 3” Vent Termination Caps and Wall Flanges (GXXX3873B) Wi-Fi 07/12/2018 NCB Series Combination Boilers Specification SheetCondensing Gas Combination Boiler Navien, Inc. 20 Goodyear, Irvine, CA 92618 Ph: (949)420-0420 Fax: (949)420-0430 www.Navien.com Rev. 11/16 Specifications Model Number1 Heating Input, MBH Heating Capacity2, MBH Net AHRI Rating, Water3, MBH NCB-180E Min 75 65 NCB-210E 18 NCB-240E 18 Max AFUE2, % 100 120 94 112 82 97 14 80 95.0 95.0 95.0 1 Ratings are the same for Natural Gas models converted to Propane use.2 Based on U.S. Department of Energy (DOE) test procedures.3 The NET AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Consult Navien before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. Item NCB-150E NCB-180E NCB-210E Gas Input Space Heating 12,000-60,000 BTU/H Domestic Hot Water 12,000-120,000 BTU/H Flow Rate (DHW)77°F (43°C) Temp Rise Dimensions 17"(W) x 28"(H) x 12"(D) Weight 66 lbs (30kg) Installation Type Indoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition Water Pressure (Hydronic/DHW) 12-30 PSI / 15-150 PSI Natural Gas Supply Pressure (from source) 3.5"-10.5" WC Propane Gas Supply Pressure (from source) 8.0"-13.5" WC Natural Gas Manifold Pressure (min-max) -0.08" WC to -0.34” WC -0.07" WC to -0.66" WC -0.05" WC to -0.36" WC Propane Gas Manifold Pressure (min-max) -0.08" WC to -0.30" WC -0.06" WC to -0.62" WC -0.1" WC to -0.66" WC Minimum Flow Rate (DHW) 0.5 GPM (1.9 L/m) Connection Sizes Heating Supply/Return 1" NPT DHW Inlet/Outlet 3/4" NPT Gas Inlet 3/4" NPT Power Supply Main Supply 120V AC, 60Hz Maximum Power Consumption 200W (up to 2 amperes) Materials Casing Cold Rolled Carbon Steel Heat Exchangers Primary/Secondary Heat Exchanger: Stainless Steel DHW Heat Exchanger: Stainless Steel Venting Exhaust 2” or 3" PVC, CPVC, Approved Polypropylene 2” or 3" Special Gas Vent Type BH (Class II, A/B/C) Intake 2” or 3" PVC, CPVC, Polypropylene 2” or 3" Special Gas Vent Type BH (Class II, A/B/C) Vent Clearances 0" to Combustibles Safety Devices Flame Rod, APS, Gas Valve Operation Detector, Ignition Operation Detector, Water Temperature High Limit Switch, Exhaust Temperature High Limit Sensor Auto Feeder 1/2" NPT Condensate Outlet 1/2" NPT 2.6 GPM (9.8 L/m) Navien Combination Boiler Space Heating Ratings NCB-240E 14,000-80,000 BTU/H 18,000-100,000 BTU/H 18,000-120,000 BTU/H 14,000-150,000 BTU/H 18,000-180,000 BTU/H 18,000-199,900 BTU/H 17"(W) x 28"(H) x 12"(D) 17"(W) x 28"(H) x 12"(D) 17"(W) x 28"(H) x 12"(D) 74 lbs (34kg) 84 lbs (38kg) 84 lbs (38kg) 3.4 GPM (12.9 L/m) 4.0 GPM (15.1 L/m)4.5 GPM (17.0 L/m) NCB-150E 56 4912 60 95.0 -0.06" WC to -1.2" WC -0.03" WC to -0.98" WC Other Specifications Water Pressure Water Connection Size (Supply, Return) 12-30 psi 1 in NPT 27.4" (695mm)28.8” (731mm)3” (77 mm)6.7” (170 mm)4.5” (115 mm) 0.4“ (10 mm)1.5”(38 mm)14.3” (364 mm)2.6” (67 mm)A B C 12“ (306 mm)3.5” (88 mm) 4.8” (123 mm) 3” (76 mm) 1.8” (46 mm) 2” (50 mm) 17.3” (440 mm)2.4” (61 mm)3.0” (77 mm)D F JEHIG Dimensions A B Pressure Relief Valve Adapter Φ 3/4" Air Intake Φ 2" Connection Size C Exhaust Gas Vent Φ 2" D G E H F Heating Supply Outlet Φ 1" Heating Return Inlet Φ 1" DHW Hot Water Outlet Φ 3/4" Gas Supply Inlet Φ 3/4" DHW Cold Water Inlet Φ 3/4” Connection Size I Condensate Outlet Φ 1/2" J Auto Feeder Inlet Φ 1/2" 07/12/2018