HomeMy WebLinkAboutFile Documents.1130 Black Birch Dr.0096.2018 (20).ARBKENERVEX®
RS 009-016 CHIMNEY FAN
ENERVEX Inc.
1685 Bluegrass Lakes Parkway
Alpharetta, GA 30004
USA
P: 770.587.3238
F: 770.587.4731
T: 800.255.2923
info@enervex.com
www.enervex.com
3932001 03.16 Product Information
Use
The RS Chimney Fan is an exhaust fan used to maintain proper
draft in a gas/oil chimney or stack system. Typical applications
include venting of:
• Fireplaces
• BBQs
• Pizza ovens & Stoves
Description
The RS Chimney Fan is specifically designed for applications
where efficient operation, low noise level, low energy
consumption, variable speed and compact design are of utmost
importance. It should be installed at the termination point of the
chimney or stack section and can be mounted on masonry or
metal chimneys. It is typically mounted in the vertical position, but
may be sidewall vented as well.
The fan assures a negative pressure is maintained in the entire
chimney or stack system. The fan discharges horizontally
(vertically, if side-wall vented) at a high velocity.
The fan housing is hinged and the top can be opened for easy
service and access to stack.
The RS is for use where flue gas temperatures do not exceed
575°F (300°C) for intermittent operation and 482°F (250°C) for
continuous operation.
The RS Chimney Fan is a component of the IntelligentDraft®
System.
Material
Housing is 3/16" thick cast aluminum. Finished with one coat of
grey hammerpaint for added corrosion resistance.
Axial vanes are stainless steel, dynamically and statically balanced
to assure low noise level and vibration-free operation.
Motor
Split capacitor, totally enclosed. Class H insulated, IP54 Protection
Class. Sealed ball bearings. Variable Speed. Thermal overload
protection.
Standard Equipment
• 2"x4" or 4"x4" Junction Box with Cover and Conduit
• Fiber Mat and Mounting Brackets
• Bird Screen
• 5 Amp Fan Speed Control
Optional Equipment
• ADC 100 Fan Control
• ADC 150 Fan Control
• EFC 211 Fan Control
• PDS Proven Draft Switch
• FSC Fan Speed Control
• SCA Steel Chimney Adaptor
• MFD-S Manual Fireplace Damper
• MFD Mechanical Fireplace Damper
Listings
The RS 009-016 Chimney Fan is ETL Listed in the U.S. and
Canada under file no. 514733:
• UL378 Standard for Draft Equipment
(for non-solid fuel installations only)
• CSA-CAN3-B255-M81 Standard for Mechanical
Flue Gas Exhausters (for non-solid fuel installations only)
Approvals
• CE Compliant
• The Commonwealth of Massachusetts
• City of Los Angeles, CA (RR 8474)
• Manufactured at ISO9001 certified plant
Warranty
• 2-Year Factory Warranty
• 10-Year Factory Warranty Against Corrosion Perforation
Complete warranty conditions are available from ENERVEX Inc.
ETL File 514733
04/20/2018
ENERVEX®
RS 009-016 CHIMNEY FAN
ENERVEX Inc.
1685 Bluegrass Lakes Parkway
Alpharetta, GA 30004
USA
P: 770.587.3238
F: 770.587.4731
T: 800.255.2923
info@enervex.com
www.enervex.com
3932001 03.16 Product Information
Specifications are subject to change without notice.
Sound Data
Model RS 009 RS 012 RS 014 RS 016
Discharge Horizontal
Fan Type Axial Vane
Motor Type Totally enclosed, Variable speed, Class H
Voltage VAC 1x120V @ 60 Hz
Amperage Amps 0.5 1.2 1.4 3.9
RPM 1600
CFM @0.0 Ps 450 950 1400 1950
Motor Output hp / kW 1/30 / .025 1/10 / 0.08 1/7 / 0.1 1/3 / 0.25
Weight lbs / kg 29 / 13 37 / 17 47 / 21 61 / 28
kg 13 17 21 28
Dimensions
A in / mm 10.2 / 259 11.5 / 292 13.1 / 334 16.0 / 407
B x B in / mm 11.7 / 296 14.3 / 364 16.6 / 422 18.8 / 478
C in / mm 10.8 / 275 13.5 / 344 15.5 / 395 17.4 / 441
D in / mm 3.0 / 75 3.3 / 85 3.9 / 100 3.9 / 100
E in 9.4 / 238 11.6 / 294 13.5 / 342 15.4 / 391
Temperature
Rating
Interm.575°F / 300°C
Cont.482 °F / 250°C
Model Lw dB (measured in accordance with ISO 3744)Lp
dB(A)125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz
RS009 54 50 47 43 38 31 25 21
RS012 64 60 55 52 48 42 34 30
RS014 75 69 65 62 57 51 44 41
RS016 81 76 72 69 64 58 52 47
Specifications
Capacity
4 3
2
1
12
11
1098
7
6
5
0250 500 750 1000 1250 1500 1750 2000
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
Volume (cfm)Ps (inW.C.)RS 016
RS 014
RS 012
RS 009
C
ADE
B
1 Junction box
2 Conduit/cord
3 Motor
4 Motor housing
5 Motor plate
6 Bird screen
7 Base plate
8 Locking nut
9 Inlet
10 Axial vane
11 Hinges
12 Capacitor (inside junction box)