Loading...
HomeMy WebLinkAboutFile Documents.1130 Black Birch Dr.0096.2018 (23).ARBK1. THE ELECTRICAL CONTRACTOR SHALL INSTALL FIXTURES SPECIFIED BY 186 LIGHTING DESIGN GROUP, INC. (186). ANY SUBSTITUTIONS MUST BE APPROVED IN WRITING BY 186. UNAPPROVED SUBSTITUTIONS ARE SUBJECT TO REPLACEMENT WITH SPECIFIED FIXTURES AT THE ELECTRICAL CONTRACTOR'S COST. 2. UPON RECEIPT OF DESIGN DOCUMENT SET, THE ELECTRICAL CONTRACTOR IS TO VERIFY ALL FIXTURE LEAD TIMES WITH DISTRIBUTOR, AND GET APPROVAL FROM THE GENERAL CONTRACTOR THAT THESE LEAD TIMES ARE ACCEPTABLE. IF ANY FIXTURE LEAD TIMES ARE NOT APPROVED BY THE GENERAL CONTRACTOR, THE ELECTRICAL CONTRACTOR IS TO CONTACT 186 IMMEDIATELY FOR ASSISTANCE WITH DECREASING LEAD TIMES OR FOR ALTERNATE SPECIFICATION. ELECTRICAL CONTRACTOR IS TO FOLLOW THIS PROTOCOL THROUGHOUT PROJECT AS NEW DRAWINGS AND SPECIFICATION SETS ARE ISSUED. 3. THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL APPLIANCE OUTLETS, DISPOSALS, AND POWER FOR SYSTEMS NOT SHOWN ON 186 PLANS (IE. POWER FOR HVAC EQUIPMENT, POOL EQUIPMENT, ETC.) INTERIOR DESIGNER IS TO SUPPLY APPLIANCE PACKAGE FOR ELECTRICAL REQUIREMENTS. GENERAL CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR SYSTEMS NOT SHOWN ON PLANS. AUDIO/VIDEO CONTRACTOR IS TO SUPPLY ALL POWER REQUIREMENTS FOR ALL A/V EQUIPMENT. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR MEETING ALL APPLICABLE CODES AND GFI REQUIREMENTS. 4. ELECTRICAL AND GENERAL CONTRACTORS ARE RESPONSIBLE FOR VERIFYING ALL FIXTURE COUNTS PRIOR TO ORDERING. 186 IS NOT RESPONSIBLE FOR ANY RESTOCKING CHARGES DUE TO MIS-ORDERING OR CHANGES BY OTHERS AFTER THE INITIAL ORDER. 5. ALL FIXTURES SHALL BE INSTALLED ACCORDING TO MANUFACTURER SPECIFICATIONS AND RECOMMENDATIONS. 6. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL IC, AIRTIGHT, AND NON-IC FIXTURE LOCATIONS PRIOR TO ORDERING FIXTURES. INSULATION TO BE HELD A MINIMUM OF 3" FROM ALL NON-IC FIXTURES. 7. ALL FIXTURE HOUSING SLEEVES AND COLLARS THAT HOLD FIXTURE TRIMS ARE TO BE COMPLETELY FLUSH WITH CEILING AT ELECTRICAL TRIM-OUT. TRIMLESS/FLANGELESS RECESSED LIGHTS ARE TO BE MOCKED UP BY THE ELECTRICAL CONTRACTOR PRIOR TO INSTALLATION. 8. ELECTRICAL CONTRACTOR IS TO NOTIFY 186 IF ANY FIXTURE LOCATIONS MUST MOVE MORE THAN SIX INCHES DUE TO FIELD CONDITIONS. 9. ALL SCONCE AND CLOCK OUTLET LOCATIONS SHOWN ON DRAWINGS ARE APPROXIMATE. EXACT LOCATIONS AND HEIGHTS OF WALL SCONCES AND CLOCK OUTLETS FOR PICTURE LIGHTS ARE TO BE VERIFIED WITH THE INTERIOR DESIGNER AND/OR OWNER. 10. ALL LED STRIP INSTALLATIONS ARE TO BE INDIVIDUALLY FED IN LENGTHS NO LONGER THAN THE MAXIMUM LENGTHS RECOMMENDED BY THE MANUFACTURER. ELECTRICAL AND GENERAL CONTRACTOR ARE TO WORK TOGETHER TO ENSURE THERE ARE NO VISIBLE WIRENUTS OR ELECTRICAL CONNECTIONS. 11. ALL FIXTURES SHALL BE SUPPLIED WITH SPECIFIED LAMPS. WHERE BEAMSPREADS ARE NOT SPECIFIED, SUPPLY WIDEST BEAMSPREAD AVAILABLE FOR PARTICULAR LAMP TYPE. 12. ALL WIRING IS SHOWN SYMBOLICALLY ON PLANS. ACTUAL REMOTE TRANSFORMER/DRIVER LOCATIONS AND HOMERUNS ARE TO BE DETERMINED BY ELECTRICAL CONTRACTOR AND GENERAL CONTRACTOR. ALL REMOTE TRANSFORMERS/DRIVERS SHALL BE TOROIDAL AND MOUNTED IN A LOCATION REMOVED FROM THE ROOM'S AIRSPACE SUCH AS AN ATTIC, CABINET, OR CRAWLSPACE, UNLESS OTHERWISE NOTED. 13. ALL SWITCHED OUTLETS SHOWN ON PLANS SHALL BE WIRED SUCH THAT THE OUTLET MAY BE SWITCHED AT ANY TIME IN THE FUTURE. VERIFY ACTUAL OUTLETS TO SWITCH WITH OWNER. ALL HALF-SWITCHED OUTLETS ARE TO HAVE SWITCHED SIDE AND HOT SIDE FED FROM SAME BREAKER. 14. EXHAUST FAN LOCATIONS ARE SHOWN SYMBOLICALLY ON THE PLANS. VERIFY EXACT EXHAUST FAN LOCATIONS WITH MECHANICAL CONTRACTOR. 15. MOTION SENSORS SHALL BE WALL-MOUNTED AT STANDARD SWITCH HEIGHT UNLESS OTHERWISE NOTED. 16. ALL LOADS TO BE LANDED ON CONTROL DEVICES IN ORDER DRAWN ON PLANS. 17. CENTER LINE OF TYPICAL SWITCH AND WALLBOX DIMMER BOXES TO BE AT 48" A.F.F. CENTER LINE OF TYPICAL CONTROL SYSTEM KEYPADS TO BE AT 54" A.F.F. (EXCEPT AT BEDROOM HEADBOARD LOCATIONS, ABOVE COUNTERS, AND OTHER NON-TYPICAL KEYPAD LOCATIONS) VERIFY WITH OWNER, ARCHITECT, AND INTERIOR DESIGNER. ELECTRICAL CONTRACTOR AND A/V CONTRACTOR TO VERIFY ALL KEYPADS BESIDE BEDS ARE INSTALLED CLEAR OF BED HEADBOARD. 18. ELECTRICAL CONTRACTOR TO VERIFY DIMMER AND CONTROL LOCATIONS. 19. ALL LOADS IN REMOTE DIMMING PANELS TO BE LANDED WHERE SHOWN ON PANEL SCHEDULE PROVIDED BY LIGHTING CONTROL SYSTEM CONTRACTOR. ELECTRICAL CONTRACTOR SHALL NOTIFY LIGHTING CONTROL SYSTEM CONTRACTOR OF ANY LOADS THAT HAVE BEEN MOVED FOR ANY REASON. 20. IN ORDER TO INSURE REMOTE ACCESS TO THE LIGHTING CONTROL SYSTEM PROCESSOR(S), A PHONE OUTLET OR ETHERNET CONNECTION, AS WELL AS AN ELECTRICAL OUTLET IS REQUIRED AT ALL PROCESSOR LOCATIONS. 21. ELECTRICAL CONTRACTOR AND A/V CONTRACTOR ARE TO VERIFY ALL FINISHES OF ELECTRICAL DEVICES, LIGHTING TRIMS, AND WALL-BOX DEVICES WITH THE INTERIOR DESIGNER AND/OR OWNERS PRIOR TO ORDERING. IF THESE COLORS OR FINISHES ARE NOT VERIFIED, ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR REPLACING EQUIPMENT AND DEVICES AT NO COST TO THE OWNERS. 22. ELECTRICAL CONTRACTOR TO PROVIDE (10) EXTRA OF 10 DEGREE SPOTS, 25 DEGREE NARROW FLOODS, 40 DEGREE FLOODS, AND 60 DEGREE WIDE FLOODS FOR AIMING AND SPARE STOCK FOR OWNER. PROVIDE FLOOD BEAMSPREADS FOR MR-16 LAMPS WHERE BEAMSPREAD IS NOT DESIGNATED ON 186 BEAMSPREAD DRAWINGS. ELECTRICAL CONTRACTOR TO REQUEST BEAMSPOREAD PLAN FROM 186 PRIOR TO PURCHASE AND ELECTRICAL TRIM OUT OF MR16 LAMPHOLDERS. 23. ALL ADJUSTABLE ACCENTS TO BE AIMED STRAIGHT DOWN AT ELECTRICAL TRIM-OUT. ELECTRICAL CONTRACTOR TO PROVIDE LADDERS AND PERSONNEL TO ASSIST 186 AND CLIENT WITH FINAL AIMING OF ADJUSTABLE FIXTURES WHEN ARTWORK AND FURNITURE ARE IN PLACE. AIMING SESSIONS ARE TYPICALLY AFTER SUNSET. 24. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR APPROPRIATE SIZING OF ALL ELECTRICAL CONDUCTORS. 12-VOLT SYSTEMS SUCH AS MONORAIL, CABLE, AND LOW VOLT TRACK SHALL BE FED WITH STRANDED WIRE OF AN APPROPRIATE GAUGE FOR LIGHTING LOAD SHOWN ON PLANS. WIRING SHALL BE SIZED SUCH THAT VOLTAGE DROP TO LOW VOLTAGE SYSTEMS IS NOT GREATER THAN 10%. IF NECESSARY, USE MULTI-TAP TRANSFORMER TO ACHIEVE REQUIRED VOLTAGE AT EACH LIGHT. ALL REFERENCES TO ELECTRICAL OR LOW VOLTAGE SYSTEMS THAT ARE NOT DIRECTLY RELATED TO LIGHTING ARE ON THE PLANS FOR REFERENCE ONLY. ACTUAL FINAL LOCATIONS AND DIMENSIONS ARE TO BE PROVIDED BY OTHERS. KEYPAD DATA OUTLET CABLE TELEVISION OUTLET THERMOSTAT TRANSFORMER SATELLITE TELEVISION OUTLET TELEPHONE QUAD OUTLET 220V OUTLET DOOR JAMB SWITCH HOT ELECTRICAL OUTLET MOTION SENSOR 1/2 SWITCHED FLOOR OUTLET HOT FLOOR OUTLET FULLY SWITCHED OUTLET 1/2 SWITCHED OUTLET WEATHERPROOF GFI OUTLET GFI PROTECTED OUTLET 3-WAY SWITCH 4-WAY SWITCH 3-WAY DIMMER FULLY SWITCHED FLOOR OUTLET DIMMER SWITCH LEGEND A/V TOUCHSCREEN LINE VOLTAGE CONTROL SYSTEM DIMMERS 220V SPEAKER SATV TS S S S S S S 3 4 JS D TV GD GFI WP GFI SP 1/4 SWITCHED QUAD OUTLET GARAGE DOOR OUTLET RF TABLETOP KEYPAD RF LAMP DIMMER - PLUG INTO HOT OUTLET CIRCUIT NUMBER HOT QUAD FLOOR OUTLET 1/4 SWITCHED QUAD FLOOR OUTLET 1234 T-STAT GENERAL NOTES 3D MR16 LEGEND 10 DEGREE SPOT BEAMSPREAD 25 DEGREE NARROW FLOOD BEAMSPREAD 40 DEGREE FLOOD BEAMSPREAD 60 DEGREE WIDE FLOOD BEAMSPREAD DIFFUSING LENS SOFT FOCUS LENS LINEAR SPREAD LENS FROSTED LENS CLEAR LENS HONEYCOMB LOUVER COLOR LEGEND SYSTEM DIMMER/HYBRID KEYPAD NON-SYSTEM DEVICES SYSTEM HOMERUN LOAD LOW VOLTAGE KEYPAD; FIREPLACE; MOTOR POWER OUTLETS FIBEROPTIC ILLUMINATOR SURFACE-MOUNTED LINEAR LIGHT LANDSCAPE ACCENT EXTERIOR PATH LIGHT UNDERWATER ACCENT WALL-RECESSED STEP LIGHT RECESSED LINEAR LIGHT IN-GROUND WELL LIGHT POST TOP LIGHT T RECESSED WALL WASH, ROUND OR SQUARE LOW VOLTAGE OR LED STRIP SHADE MOTOR / WINDOW MOTOR EXHAUST FAN CEILING FAN 12V OR 24V ROUGH-IN JUNCTION BOX MONOPOINT HEAD DUAL-HEADED MONOPOINT TRACK LIGHTING HANGING PENDANT OR CHANDELIER WALL MOUNTED FIXTURE RECESSED ADJUSTABLE ACCENT, ROUND OR SQUARE MINI-RECESSED DOWNLIGHT OR PUCKLIGHT RECESSED DOWNLIGHT, ROUND OR SQUARE CEILING MOUNTED FIXTURE W P C CLOCK OUTLET FOR PICTURE LIGHTCO 48" FO FP JB POOL LIGHT LONG HANGING PENDANT OR CHANDELIER, VERIFY FEED LOC. FIREPLACE IGNITION 1-HEADED RECESSED MULTIPLE 2-HEADED RECESSED MULTIPLE 3-HEADED RECESSED MULTIPLE P RECESSED LINEAR WALL WASH 12/24V JB JUNCTION BOX JB RGBW 5-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX JB RGB 4-CONDUCTOR LOW VOLTAGE ROUGH-IN JUNCTION BOX WALL MOUNTED SWING-ARM LAMP OR MAKEUP MIRROR WITH INTEGRAL SWITCH XFMR SP NFL FL WFL DIFF SOFT LIN FROST CLR LOUV VERIFY IN FIELDVIF TABLE OF CONTENTS E.1.001 STANDARD LEGENDS & NOTES & E.2.001 LOWER LEVEL LIGHTING PLAN E.2.002 MAIN LEVEL LIGHTING PLAN E.2.003 ROOF DECK LIGHTING PLAN LIGHT.2.001 LANDSCAPE LIGHTING PLAN E.1.0011130 BLACK BIRCHASPEN, CO186 L IGH T IN G DE S IGN GROU P ,I NC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-03-28 PERMIT SET 2018-06-29 PROGRESS SET 2018-09-07 PRICING SET 2018-09-26 CONSTRUCTION DOCUMENTS 2018-12-20 REVISION 1 2019-02-05 REVISION SHEET NUMBER: PAGE TITLE: STANDARD LEGENDS & NOTES NO SCALE LEGEND & GENERAL NOTES 02/26/2019 03/05/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 04/04/2019 tonyf ICEDW REF WINE C C C C 36 Z1 Z1 Z1 Z1 Z1 Z1 Z1Z1 VIF VIF A2 A1 S1 A2 L1 A1 A1 A1A1 A1 A1 A1 A1 A1 L5-RGBWL5-RGBW L5-RGBWL5-RGBW L5-RGBWL5-RGBWL5 -RGBWL5-RGBWA1 A1 A1 A1 A1 A1A1 A1 A1 A1 S1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 S1 S1 A1 A1 S1 L4 L3 L3 L3 L3 L1 P P P P P P A2 A2 A1 A1 P P P SSSSJS M1 M1 M1 M1 EX FN EX FN EX FN EX FN EX FN EX FN EX FN EX FN EX FNL6WW A1 A1 FP TV ILLUMINATED CLOSET ROD A2 SJS SJSSSFP TV ILLUMINATED CLOSET ROD JS JS A2 A2 A2 P P S1 S1 A1 WW A1S1 W LIGHT CHANNEL ABOVE HEADER WALL SCONCE WITH INTEGRAL ONE PER BUNK. REFERENCE INTERIOR DRAWINGS FOR HEIGHT. W WALL SCONCE WITH INTEGRAL SWITCH. ONE PER BUNCK. REFERENCE INTERIOR DRAWINGS FOR HEIGHT. MONOPOINTS ABOVE WINDOW EXIT W W WALL SCONCE WITH INTEGRAL ONE PER BUNK. REFERENCE INTERIOR DRAWINGS FOR HEIGHT. A1 L1 LIGHT CHANNEL TO FLOAT VANITY L1 LIGHT CHANNEL TO FLOAT VANITY L1 L1 LIGHT CHANNEL UNDER VANITY S1 LIGHT CHANNEL UNDER BAR L5-RGBWL5-RGBWA2 A2 39" A2 A2 A2 A2 A2 ART L5-RGBW 51" L5-RGBW P L5-RGBW L5-RGBW L5-RGBWZ1 Z1 COVE LIGHT INTO TALL CEILINGL5-RGBWVIF Z1 Z1 A1 A1 A1 A1A1 A1 EDGE LIT SHELVES, QUANTITIES TBD48"MONOPOINTS ABOVE WINDOW EXIT C 48"L6 48"L648"L648"L648"L648"L648"L6A1 TVTV MONOPOINTS ABOVE WINDOW EXIT MONOPOINTS ABOVE WINDOW EXIT COVE LIGHT A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A1 A2 A2 ARTCOFFEE TABLE A2 38" A2 A2 A2 A2 A2 A2 COVE LIGHT INTO TALL CEILING A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 L5-RGBW L5-RGBW TOEKICK LIGHT A4 A4 A4 A1 A1 A1A1 L5-RGBW TOEKICK LIGHT ARTL5-RGBW UNDERCABINET BACK LIT MIRROR A1 A1 Z1 Z1A1A1A1 Z1 A2 Z1 ST1 ST1 ST1 ST1 ST1 A1 A1 A1 A1 A1 A1 S1 S1 S1 A1 A1 BACKLIT MIRROR BACKLIT MIRROR A1 A1 A1 A1 0231 0232 0233 0234 0261 0262 0263 01710172 0173 0174 0181 0182 0183 0201 0203 0202 0131 0132 0133 0141 0142 0143 0144 0145 01460147 0148 0081 0082 0083 0084 0085 0086 0087 0088 0071 0021 0041 0061 0062 00630064 0065 0066 0011 0031 0032 0033 0151 0152 0153 0161 0162 0163 01640165 808 33 3435 36 37 38 39 40 41 42 4445 46 48 4950 51 52 53 54 56 55 57 58 59 6061 FP-01 FP-02 FP-03 FP A1 A1 A1 A1 A1 A1 C C C GYM 022 0221 0222 S1 S1 S1 SS0111 0112 0113 0114 0115 0116 0117 0118 0119 0120 0121 0122 REC ROOM 011 CARD ROOM 018 CLO 019AV 021 GAME ROOM 017 BAR 012 BEDROOM 4 015 BEDROOM 3 013 BATH 3 014 BUNK BATH 2 008 BUNK ROOM 2 007 BUNK ROOM 1 004 BUNK BATH 1 006 CLO CLO CLO 010 BUNK HALL 002 LAUNDRY 003 ELEV 025 GYM BATH 023 MECH 024 0110 01120 01121 L7 LIGHT IN BASE OF NICHE 0154 0155 L7 0136013401350137 LIGHT IN BASE OF NICHE 0156 0157 L1 62 A1 P L5-RGBWL5-RGBWL5-RGBW0175 L5-RGBWL5-RGBW0176 LED LIGHT CHANNEL UNDER COUNTER L1 L1 BACKLIT MIRROR L1 INVERSE COVE 0177 0178 42" 0123 A4 A1 COVE LIGHT COVE LIGHTING A1 0179 COORDINATE FIXTURE DROP W/DOOR SWING EQ EQ EQ EQ CEILING MOUNTS TO BE FUNCTIONAL A1 63 VIF UPLIGHT FROM LEDGE COVE LIGHT INTO TALL CEILING COVE LIGHT C/L STAIR L1 W W W W W W P L1 L1L1 L1 PP EX FN 0065 0264 L1 BACKLIT MIRROR INVERSE COVE 0204 1130 BLACK BIRCHASPEN, CO186 L IGH T IN G DE S IGN GROU P ,I NC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-03-28 PERMIT SET 2018-06-29 PROGRESS SET 2018-09-07 PRICING SET 2018-09-26 CONSTRUCTION DOCUMENTS 2018-12-20 REVISION 1 2019-02-05 REVISION SHEET NUMBER: PAGE TITLE: E.2.001 LOWER LEVEL LIGHTING PLAN LOWER LEVEL LIGHTING PLAN 1/4" = 1'-0" 02/26/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 03/06/2019 04/04/2019 tonyf W OVEN FLUSH-MOUNT HEATER FLUSH-MOUNT HEATER WALL-MOUNT HEATER TRASH ICE WINE DW MW REF FRZ REF DW REF 25 ST1 ST1 ST1ST1 ST1 A1 A2 A2 P A2 A2 A2 A2 A2 A2 A2A2A2 A2 A2 A2 P A3A3 A3 A2 A2 P P P P L1 L1 A2 A1 A1 A2 L1 L1 A2 A2 A1 A2 S1 S1 S1 S1 A2A2A2 A2 A2 A1 A2 A2 S1 A1 A1 A1 A1 A1 A1 A1 C A1 A1 P A1 A1 A2 A1 A1 A1 A1 A1 A1 A1A1A1 P A1 A1 S1 A2 A2 A2 A1 A1 P P L1 L1 A3A3 A3 A3A3A3 W1W1 A3 A3 A3 A1 A1 A2 A1 EX FN W1W1 EX FN EX FN EX FN EX FN W1A3A3A3 M1 W1 1152 1151 P ART30" 30" FP L3 L3 S SS ILLUMINATED CLOSET ROD ILLUMINATED CLOSET ROD P P P A1 A2 A2 A2 A2 L3 L3 SS JS JS JS JS JS SHORT WALL ILLUMINATED CLOSET ROD L3 L3 A2A2 A2 A2A2 A2 A2 A2 30" L2 30" L3 L3 ILLUMINATED CLOSET ROD L3 L3 CART38" A2 A2A2ART 38"ARTART ART A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 A2 P Z1Z1 ARTA1 A1 ART SOFA FP A1 A1 A1 A1 CONSOLE TABLE A1 A1 A1 A1 TABLETABLE TABLE TABLE CHAIRCHAIR A3 A3 SOFA SOFA UNDERCABINET LIGHT CHANNEL TO LIGHT SHELF HOOD WITH INTEGRAL LIGHT AND FAN A1 A1 A1 A1 A1 A1 CHAIR CHAIR A2 A2 FP FP FP 40" L1 UNDERCABINET A1 A1 A1 A1 A1 A1 A2 A2 A2 A1 A1A1 P P A1 A1 A1A1 L1 UPLIGHT FROM SHELF FROM THE TWO UPPER SHELVES. LOWER SHELF DOWNLIGHT.ARTARTSOFA CONSOLE TABLE INVERSE COVE A2 A2 A2 A2 A2 A2 L2 IN FLOOR UPLIGHT A3 A3 L1 LIGHT CHANNEL UNDER BAR TOP A2A2 A2 A2 A2 A2 A2A2 W1 W148"L648"L648"L648"L648"L648"L6A3 Z1 Z1 P ST1 ST1 ST1 ST1 ST1 EX FN S1 C S1 S1 S1 S1 A2 A2 A2 A2 A2 A2A2A2 LIGHT UNDER VANITY L1 UNDERCABINET 1171 1172 1173 1174 1161 1162 1163 1168 1164 1165 1166 1167 1181 1182 1191 1211 1212 1213 1011 1012 1013 1014 1015 1031 1041 1042 1043 1044 1032 1033 1034 1051 1052 1061 1062 1063 10641081 1082 1083 1084 1085 1107 1131 1132 1131 1133 1134 1135 1136 1141 1138 11371139 1142 1153 1154 11561157 1158 1159 1071 1072 1201 804 805 806 807 01 02 03 04 05 06 07 08 10 11 12 13 14 15 16 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 FP-04 FP FP FP-06 FP-07 DINING AND GREAT ROOM 110 MUDROOM 119 GARAGE 120 PANTRY 118 PWDR 1 121 ELEV 122 KITCHEN 116 FAMILY ROOM 117 WINE ROOM 109 ENTRY 101 BEDROOM 1 103 BATH 1 104 CLO 105 T1 TH1TH1 A2 A2 1016 1091 1101 1102 1103 1104 1105 MASTER BED 115 MASTER BATH 113 MASTER HALL 112 MASTER CLOSET 114 OFFICE 111 BEDROOM 2 106 CLO 107 BATH 108 1111 L3 L3 L3 L3 SSSSS11341 11342 L2 PL 1112 COORDINATE FIXTURE LOCATION WITH GARAGE DOOR 1143 ILLUMINATED CLOSET ROD 17ARTJSJSJSJSJS 809 810 1106 A2 11343 A2 ILLUMINATED CLOSET ROD EQ EQ EQ EQ A2 A2 11691175 811 812 A1 S1 TH1 TH1TH1 11610 46" PENDANTS NEED TO BE FUNCTIONAL FOR GOOD LIGHTING AT MASTER VANITY 1108 1109 TH1 TH1 TH1 LIGHT CHANNEL UNDER SHELF. 1 LIGHT CHANNEL PER SHELF L1 1092 P P P P BACKLIT MIRROR 11344 P PA3 A5 A5 VERIFY LOCATION COVE LIGHT L8 L8 L8 L8 C/L TABLE C/L TABLE DN 24R @ 6" REF REF REF REF MW DW WINE ICE TC DW ST1 ST1 ST1 CONTINUES ABOVE VIF 64VERIFY KEYPAD CAN BE LOCATED IN SEMI-ENCLOSED AREA 09 1130 BLACK BIRCHASPEN, CO186 L IGH TI NG DE S IGN GROU P,INC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-03-28 PERMIT SET 2018-06-29 PROGRESS SET 2018-09-07 PRICING SET 2018-09-26 CONSTRUCTION DOCUMENTS 2018-12-20 REVISION 1 2019-02-05 REVISION SHEET NUMBER: PAGE TITLE: MAIN LEVEL LIGHTING PLAN 1/4" = 1'-0"E.2.002 MAIN LEVEL LIGHTING PLAN 02/26/2019 Lens must be frosted. If mounted more than 12 feet in height, then light source must be fully shielded 03/05/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 04/04/2019 tonyf DINING / GREAT ROOM 110 ST1 ST1 ST1 ST1ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1 ST1ST1 802 801 CONTINUES BELOW 1130 BLACK BIRCHASPEN, CO186 L IGH TI NG DES IGN GROU P,INC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-03-28 PERMIT SET 2018-06-29 PROGRESS SET 2018-09-07 PRICING SET 2018-09-26 CONSTRUCTION DOCUMENTS 2018-12-20 REVISION 1 2019-02-05 REVISION SHEET NUMBER: PAGE TITLE: ROOF DECK LIGHTING PLAN 1/4" = 1'-0"E.2.003 ROOF DECK LIGHTING PLAN 02/26/2019 03/05/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 04/04/2019 tonyf 25'20'48'-10"10' 10'10'15'50'-1134" PROPOSED CULVERT, PER CIVIL PRIVATE ROAD NON-CONFORMITY TO REMAIN CASTLE CREEK + ROARING FORK RIVER CONFLUENCE BLACK BIRCH DRIVE PROPERTY L I N E UTILITY EASE M E N T SETBACK LIN E PROPERTY LINESETBACK LINEPROPERTY LINESETBACK LINE15' T.O. B A N K S E T B A C K COVER VAULT GRILLMONOLITHICSTONEPLANTING GAPBOULDE R ST1 ST1 B1B1 B1 ST1 ST1 NOTE: FOR FIXTURE TYPES ATTACHED TO HOUSE SEE HOUSE PLANS FOR FIXTURE DESIGNATIONS. DARK SKY COMPLIANT WALL SCONCE WALL MOUNTED MONOPOINT TO DOWNLIGHT BOULDER FOR SAFETY WALL MOUNTED MONOPOINT TO LIGHT DOWN INTO WINDOW WELL FULLY SHIELDED PATH LIGHT FOR SAFETY FULLY SHIELDED IN WALL LIGHT TO LIGHT DOWN ONTO THE GROUND FOR SAFETY FULLY SHIELDED IN WALL LIGHT TO LIGHT DOWN ONTO THE GROUND FOR SAFETY DARK SKY COMPLIANT WALL SCONCE DOWNLIGHTS MOUNTED IN OVERHANG NOTE: ALL EXTERIOR LANDSCAPE LIGHTING ON PHOTOCELL/TIMECLOCK WITH OVERRIDE SWITCH INSIDE HOUSE. E1 E1 <12' TREE DOWNLIGHT DETAIL TYP. E1 DOWNLIGHTS MOUNTED IN OVERHANG DOWNLIGHTS MOUNTED IN OVERHANG DOWNLIGHTS MOUNTED IN OVERHANG 150 SQUARE FEET BETWEEN FIXTURES WALL MONOPOINT MOUNTED IN WINDOW WELL TYP. DOWNLIGHT MOUNTED IN TREE FOR SAFETY DOWNLIGHTS MOUNTED IN OVERHANG 901 902 903 1130 BLACK BIRCHASPEN, CO186 L IGH T IN G DE S IGN GROU P ,I NC. 1200 BANNOCK ST. DENVER, CO 80204 TEL:303.534.5350 www.186group.com DATE REVISION & ISSUE 2018-03-28 PERMIT SET 2018-09-26 CONSTRUCTION DOCUMENTS 2018-12-20 REVISION 1 2019-02-05 REVISION SHEET NUMBER: PAGE TITLE: LIGHT.2.001 LANDSCAPE LIGHTING PLAN LANDSCAPE LIGHTING PLAN 1/8" = 1'-0" 02/26/2019 For the tree mounted flood lights (E1): Per Section 26.575.150, Outdoor Lighting.(F), Residential Lighting Standards.(e).2 & 3, Flood lights must be controlled by a switch or preferably a motion sensor activated only by motion within owners property. Timer controlled floodlights shall be prohibited. All applicable residential lighting standards must be satisfied. Lens must be frosted. If mounted more than 12 feet in height, then light source must be fully shielded03/05/2019 ALL OUTDOOR LIGHTING MUST COMPLY WITH THE CITY OF ASPEN LIGHTING CODE SECTION 26.575.150 04/04/2019 tonyf