HomeMy WebLinkAboutFile Documents.1039 E Cooper Ave.0226.2017.ARBK0226-2017-ARBK_BuildingComments_1 Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Provide a sound underlayment product spec sheet for the new tile to achieve and IIC rating of 50 or greater (2015 IBC 1207). FULL PLANS SET.pdf (10) Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: If dwelling separation walls are disturbed, they must be asbestos abated and a 1 hour fire and STC 50 sound rated assembly must be submitted and approved. Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: If dropped ceilings in bathrooms are disturbed, they must be abated and a 1 hour fire and STC 50 rated assembly must be submitted and approved. Page: 1 File Name: FULL PLANS SET.pdf Subject: 75% high efficacy lamps Author: nickt Color: A minimum of 75% of all lamps installed in permanent light fixtures must be high efficacy in dwelling units. Note this requirement on the plans. (2015 IECC R404.1 & C405.1) Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Provide an existing floor plan. Provide a sound underlayment product spec sheet for the new tile to achieve and IIC rating of 50 or greater (2015 IBC 1207). If dwelling separationwalls are disturbed,they must be asbestosabated and a 1 hourfire and STC 50 soundrated assembly mustbe submitted andapproved. If dropped ceilings inbathrooms aredisturbed, they mustbe abated and a 1hour fire and STC 50rated assembly mustbe submitted andapproved. A minimum of 75% of all lampsinstalled in permanent light fixtures must be high efficacy in dwelling units. Note this requirement on theplans. (2015 IECC R404.1 & C405.1) Provide an existing floor plan. See attached document sound specs See USG document attached Noted on plan Provided See fire rated assembly attached 3/04/2018 Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Provide a completed IBC building description form. Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Ceilings may not be dropped anywhere unless a 1 hour fire and STC 50 sound rated assembly is provided and approved. Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: If Dryer is being removed, please remove it from the plans. Page: 1 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Provide make up air if kitchen hood exhausts greater than 400 cfm. Page: S1.2 File Name: FULL PLANS SET.pdf Subject: PlanCheck Author: nickt Color: Snow load should be 100psf per Ordinance 16, 2014. Revise S1.2. Provide a completed IBC building description form. Ceilings may not bedropped anywhereunless a 1 hour fireand STC 50 soundrated assembly isprovided andapproved. If Dryer is beingremoved, pleaseremove it from theplans. Provide make up air ifkitchen hood exhaustsgreater than 400 cfm. Snow load should be100psf per Ordinance16, 2014. Revise S1.2. Dryer removed Re circulation hood See fire rated assembly IBC document attached Change made 3/04/2018