Loading...
HomeMy WebLinkAboutFile Documents.800 S Mill St.0123.2018 (8).ARBK 1 HealthSafe Inspections Inc 390 Apple Drive Basalt CO 81621 970-920-2100 Jim Baker CDPHE Asbestos Building Inspector, Asbestos Air Monitoring Specialist (AMS) & Project Designer Certification #13437 CDPHE Lead-Based Paint Inspector & Lead Hazard Assessor Certification #23607 ASBESTOS ABATEMENT CLEARANCE REPORT DATE 05/22/2018 CLIENT 800 S Mill 303, LLC. c/o Matt Brown 515 W Gillespie Ave Aspen CO 81611 PROJECT PROPERTY ADDRESS 800 South Mill Street, Fifth Avenue Condominium #7, Aspen, Colorado 81611 For orientation purposes, the front door faces south. CLIENT BACKGROUND The Client, 800 S Mill 303, LLC., hired HealthSafe Inspections, Inc. (hereinafter, HealthSafe) to perform a post-abatement clearance for asbestos containing sheet vinyl flooring which was abated, that is, removed entirely from the kitchen and adjacent bathroom. This required an asbestos abatement permit from CDPHE (Permit Notice #18P12525A dated 04/30/2018) and a certified asbestos abatement. Prestige Environmental Services, Inc. provided the asbestos abatement and called for the abatement clearance inspection and PCM air sampling once their abatement of the sheet vinyl flooring layers was completely removed and disposed of. 2 VISUAL INSPECTION & LABORATORY FINDINGS An asbestos post-abatement visual clearance inspection and PCM air sampling was conducted by Jim Baker of HealthSafe on Friday May 18, 2018. The visual clearance verified that all friable sheet vinyl flooring had been completely removed from the plywood subflooring in the kitchen and adjacent bathroom. All debris was removed and the remaining subfloor was virtually dust-free. No further abatement, removal or cleaning procedures were required. Following the visual clearance, clean rotary vane sampling pumps were warmed up for 5- 10 minutes and site calibrated. A box fan was deployed at a 45°angle off the east wall of the bathroom and the containment area blown with a leaf blower as required by the regulations for clearances. PCM samples were set in locations to represent the distribution of air throughout the containment-abatement space. A trip blank and two field blanks, opened for 30 seconds, were included in the batch of five PCM air samples, but were not required to be analyzed by the laboratory. 3 HEALTHSAFE PCM LABORATORY DATA The five PCM air samples at total volumes between 930 and 941 liters of air all had less than 0.005 fibers detected (<0.005 f/cc) per cubic centimeter of air. This well below the 0.01 f/cc level for clearance. See attached Hayes laboratory report #18015520. CONCLUSIONS Based on the visual post-abatement verification clearance inspection and based on the post-abatement PCM air sample data, the containment area of the dining and bathrooms spaces has fully passed abatement clearance. The containments and equipment can be disassembled and removed. Repairs and/or remodeling can commence at once. Sincerely Submitted, Jim Baker owl �6L/v�� '0 33 g3LnJlL L -- S od i o• LlCT 10 ; c-1 � O ..A. os 1 � -3-�. 1'0.- 0 I O• � 10.1 -- �-�-Q � 0 Q f V ♦ HMC #18015520 contact@hayesmicrobial.com http://hayesmicrobial.com/ Analysis Report prepared for HealthSafe Inspections 390 Apple Drive Basalt, CO. 81621 USA Phone: 970-920-2100 Job Name: C/O Matt Brown 800 S. Mill St., #7 Aspen, CO 81611 Date Sampled: 05-18-2018 Date Analyzed: 05-21-2018 Report Date: 05-21-2018 EPA Laboratory ID# VA01419 NVLAP Lab Code: 500096-0 Asbestos License: 300435 License: #PH-0198 Page 1 of 4 HMC #18015520 HealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA May 21, 2018 Client Job Number: Client Job Name:C/O Matt Brown 800 S. Mill St., #7 Aspen, CO 81611 Dear HealthSafe Inspections, We would like to thank you for trusting Hayes Microbial for your analytical needs. On May 21, 2018 we received 5 samples by FedEx for the job referenced above. 5 samples were received in good condition. The results in this analysis pertain only to this job, collected on the stated date and should not be used in the interpretation of any other job. This report may not be duplicated, except in full, without the written consent of Hayes Microbial Consulting, LLC. This laboratory bears no responsibility for sample collection activities, analytical method limitations, or your use of the test results. Interpretation and use of test results are your responsibility. Any reference to health effects or interpretation of mold levels is strictly the opinion of Hayes Microbial Consulting. In no event, shall Hayes Microbial Consulting or any of its employees be liable for lost profits or any special, incidental or consequential damages arising out of your use of the test results. Steve Hayes, BSMT(ASCP) Laboratory Director Hayes Microbial Consulting, LLC Page 2 of 4 HMC #18015520 Asbestos PCM AnalysisHealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA Phone: 970-920-2100 Job Number: Collected by: Email: Jim Baker healthsafeinspections@gmail.com Job Name:C/O Matt Brown 800 S. Mill St., #7 Aspen, CO 81611 Date Collected: Date Received: Date Reported: 05/18/2018 05/21/2018 05/21/2018 page1 HMC ID Number: 18015520 - 4 Sample Media: Air - Asbestos Sample ID Number: 04 Sample Name: SE Bath Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 930.00 1 / 100 <0.005 HMC ID Number: 18015520 - 5 Sample Media: Air - Asbestos Sample ID Number: 05 Sample Name: Clst Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 930.00 1 / 100 <0.005 HMC ID Number: 18015520 - 6 Sample Media: Air - Asbestos Sample ID Number: 06 Sample Name: Hlwy Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 940.00 1 / 100 <0.005 HMC ID Number: 18015520 - 7 Sample Media: Air - Asbestos Sample ID Number: 07 Sample Name: Kit Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 940.00 1 / 100 <0.005 HMC ID Number: 18015520 - 8 Sample Media: Air - Asbestos Sample ID Number: 08 Sample Name: NE Bath Sample Volume Fiber Count Fibers/mm2 Fibers/CC Notes 941.00 1 / 100 <0.005 Signature: Date:05/21/2018 Reviewed by: Date:05/21/2018 Page 3 of 4 HMC #18015520 Asbestos - Additional InformationHealthSafe Inspections 390 Apple Drive Basalt, CO 81621 USA Phone: 970-920-2100 All samples were received in acceptable condition unless otherwise noted on the report. The Report must not be used by the client to claim product certification, approval, or endorsement by: AIHA, NIST, NVLAP NY ELAP, or any agency. The results relate only to the items tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data can be provided when requested. None detected: Below the detected reporting limit of 1% unless point counting is performed, then the detected, reporting limit is .25%. Per NY ELAP198.6 (NOB) TEM is the only reliable method to declare an NOB material as Non-Asbestos Containing. Hayes Microbial Consulting reserves the right to dispose of all samples after a period of 60 days in compliance with state and federal guidelines. Signature: Date:05/21/2018 Reviewed by: Date:05/21/2018 Page 4 of 4