Loading...
HomeMy WebLinkAboutFile Documents.845 Meadows Rd.0008.2019.ACBK0008-2019-ACBK_BuildingComments_1 Page: A2.02 BASEMENT LEVEL•50FLOOR PLAN (SOUTH)•50ENLARGED File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Revise to show all kitchen equipment, work surfaces, and seating areas. Demonstrate accessibility per 2015 IBC 1109.4 and 1109.11. ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf (7) Page: A6.09.3 DOOR DETAILS File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Indicate the clear opening width when door is open to 90 degrees. Minimum 32" required 2015 IBC 1010.1.1. Page: A8.00 BASEMENT•50REFLECTED CEILINGPLAN File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Provide an updated lighting comcheck and lighting cutsheets. Page: A8.00 BASEMENT•50REFLECTED CEILINGPLAN File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: Occupancy sensors Author: nickt Color: Provide occupancy sensor controls to control lights in all locations called for by 2015 IECC C405.2.1. Page: A8.00 BASEMENT•50REFLECTED CEILINGPLAN File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: Time switch controls Author: nickt Color: Provide time switch controls to control lights in all locations without occupancy sensors as called for by 2015 IECC C405.2.2. Revise to show allkitchen equipment,work surfaces, andseating areas.Demonstrateaccessibility per 2015IBC 1109.4 and1109.11. Indicate the clear opening width when door is open to 90 degrees. Minimum 32" required 2015 IBC 1010.1.1. Provide an updated lighting comcheck and lighting cutsheets. Provide occupancy sensor controls to control lights in all locations called for by 2015 IECC C405.2.1. Provide time switch controls to control lights in all locations without occupancy sensors as called for by 2015 IECC C405.2.2. Page: A9.16 INTERIOR DETAILS File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Microwave controls must be within accessible reach ranges. ICC A117.1-2009 section 804.5. Page: A9.16 INTERIOR DETAILS File Name: ARCHITECTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: The sink in the employee dining area must comply with the following: 1. Clear floor space must be centered on the sink- dimension the location of the sink centerline from the side wall to make this clear. 2. Clear floor space for forward approach must extend underneath the sink with knee and toe clearance. This requires a minimum 30" width between legs of the counter and 27" knee clearance. Toe clearance is also required and the sink plumbing must be protected. Provide sufficient details and dimensions to demonstrate compliance. ICC A117.1-2009 section 804.4. Page: 3 File Name: MECHANICAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Demonstrate that the duct termination serving the new Type II kitchen hood complies with the requirements of 2015 IMC 506.4. MECHANICAL SHEETS.845 MEADOWS ROAD.013019.pdf (2) Page: 3 File Name: MECHANICAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Show the steam food serving table and any other kitchen equipment in the architecturals. Demonstrate accessibility as required by 2015 IBC ch 11.5'-8"-2"2'-6"VIVREAUFRIDGECARTSINK OPEN COFFEE MACHINE PANINI MICROWAVE 2"1"4"PATTERNPL3 5'-5" 2'-6" PL3 2'-512"DW1 2 A9.16 4"OPEN OPEN 3 A9.16 30"X48" CLEAR FLOOR AREA SCALE: EMPLOYEE DINING 014 BAR COUNTER 1/2" = 1'-0" 1 A9.16 Issue: 1-24-19 PRO 924 ANACAP SANTA BA PHON DATE 1-30-19 BUILDI 1-30-19 BUIL Microwave controls must be within accessible reach ranges. ICC A117.1-2009 section 804.5.5'-8"3'-2"2'-6"VIVREAUFRIDGECARTSINK OPEN COFFEEMACHINE PANINI MICROWAVE 2"COFFEEMACHINE PANINI MICROWAVE VIVIREAU SINK 1"4"BACKSPLASH PL3:LAMINATE: WILSONART, 4996-38, HIGHRISECABINET PULLS: MOCKETT # DP3C 1/2" X 6", 17S FINISH SINK:JOHN BOOS MODEL NO. PB-DISINK101405 (APPLY SPRAY FOAMSOUND DEADENING TO BODY OF SINK)FAUCET:FISHER MODEL NO. 3512.PATTERNADJ. SHELF PATTERN PL3 5'-5"2'-1"1'-0"2'-6" 7'-734" 2'-9" B1 PL3 PL3 FRONT PANEL 2'-6"5'-414" TRUE ELEVATION TRUE ELEVATION 2'-512"DW1 2 A9.16 2"2"2"2"4"OPEN OPEN 3A9.16 3A9.16 2'-912"30"X48"CLEAR FLOOR AREA 2'-312"2'-1 " INSULATE ALLPIPES UNDER SINK ALL INTERIOR SURFACES OF CABINET &ADJUSTABLE SHELVES (ON METAL PINS)SHALL BE WHITE MELAMINE.4"2"3'-2"2'-6"2'-612"PULLS: MOCKETT # DP3C 1/2" x 6",17S FINISH 2'-1" 1" RUBBER BASE PATTERN 1'-1" PL3 PL3 PL3 B-1 SCALE: EMPLOYEE DINING 014 BAR COUNTER 1/2" = 1'-0" 1 A9.16 EMPLOYEE DINING 014 BAR COUNTER ELEVATION2EMPLOYEE DINING 014 BAR COUNTER TYPICAL SECTION3 The sink in the employee dining area mustcomply with the following: 1. Clear floor space must be centered on thesink- dimension the location of the sinkcenterline from the side wall to make thisclear. 2. Clear floor space for forward approach must extend underneath the sink with knee and toe clearance. This requires a minimum30" width between legs of the counter and27" knee clearance. Toe clearance is alsorequired and the sink plumbing must beprotected. Provide sufficient details anddimensions to demonstrate compliance. ICC A117.1-2009 section 804.4. B B C C X.B FC-1 20"x8"AHU-2 24"x8"24"x8"OA BD-1 (525cfm), for AHU-2 EF-418"x14"22"x6" d below next tordinate with Arching. Provide backdraft damper andceiling access panel at EF-4. Route EA and OA ducts side-by-side, tight tostructure above. Coordinate routing with all otherdisciplines in field, typ. SA UP, typ. 1 2 3 3 4 4 4"x8"Heat/steam exhaust hood (by Others)over steam food serving table shouldbe approximately: 72"W x 36"D x24"H. Height of bottom lip: 80" AFF;centered over steam table. Stainlesssteel material. EF-3 10"ø Existing EDR exhaust fan and ceiling cassette fan coil unit toremain as installed, including backdraft damper, access panel,ductwork, return grille location and size, etc.) 8"x6" 175 CFMR3 10"x8"14"x8"5 5 Project Me Dash Rou Boile prov man Prov unit, isola Prov 4 4 Duc Demonstrate that the duct termination serving the new TypeII kitchen hoodcomplies with therequirements of 2015IMC 506.4. B C X.B de backdraft damper and g access panel at EF-4. SA UP, typ. Heat/steam exhaust hood (by Others) over steam food serving table should be approximately: 72"W x 36"D x 24"H. Height of bottom lip: 80" AFF; centered over steam table. Stainless steel material. 4 Show the steam food serving table and any other kitchen equipment in the architecturals. Demonstrate accessibility as required by 2015 IBC ch 11. Page: 3 File Name: PLUMBING SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Revise architecturals to show exterior fixtures including the exterior hand sink. If sink is not in an employee workspace it must be accessible. PLUMBING SHEETS.845 MEADOWS ROAD.013019.pdf (1) Page: [5] s71-S7.10-ALT File Name: STRUCTURAL SHEETS.845 MEADOWS ROAD.013019.pdf Subject: PlanCheck Author: nickt Color: Provide a signed special inspection agreement form for the structural steel welding, bolting, and epoxy anchors. STRUCTURAL SHEETS.845 MEADOWS ROAD.013019.pdf (1)1"ø Cu 1"ø Cu UM-1 1 2 3 4 5 S-3 1/2"ø 3 5 Provide shut off and drain valves to enablewinterization of outdoor hand sink at grillarea. Locate shutoff valves on South wall ofPavilion basement mechanical space.Provide exterior drains at low point of hotand cold water supplies to allow easy draindown of exterior KS-2. Owner is responsiblefor drain down and winterization of supplylines whenever outside air temperature isbelow freezing. KS-2 Route to exterior hand sink (KS-2). 3/4"ø3/4"ø GRILL-1 Refer to Architectural plans for exact locations ofexterior fixtures and appliances. Route adedicated gas line from service in street. Sizingand routing is per Contractor. 5 A B C D X.2 X.3 X.3 A X.A X.B 6 3P1.00 1/8" = 1'-0"1 Basement Level Pipin Project Piping Notes Gas line sized for Sch.-40 black metallic. Applian shutoff valve within 6' of all gas appliances, typ. R All water distribution lines within UM-x outlines (s Route hot water distribution piping in a serpentin fixture groups, as shown. Route all piping in ceiling plane above. Route in perpendicular to beam orientation. Locate field-fabricated utility manifold (UM-1) in w lines to utility manifold for distribution within fixtur valves for each incoming HW and CW branch lin All domestic water lines to follow existing branch 4 Revise architecturalsto show exteriorfixtures including the exterior hand sink. Ifsink is not in anemployee workspaceit must be accessible. ELEVATION VIEW £2½X2½X¼"X0'-8" £2½X2½X¼"X0'-8"EA SIDE 2-¼"ØX3" SDS EA £ 2-Å"Ø THRU BOLTSW/ SLOTTED HOLESIN £,OR Á"X1" FILLETWELD TOP AND BOTT(FIELD WELD ASREQ'D) 2S7.10 PANEL TO WALL CONNECTION DETAIL 1"=1'-0" PLAN VIEW ELEVATION VIEW £2½X2½X¼"X0'-8"EA SIDE -¼"ØX3" SDS EA £ HSS TO MATCH (E)SCEEN FRAME,HSS1½X1½XÁ" MIN £2½X2½X¼"X0'-8"EA SIDE 4-¼"ØX3" SDS EA £ ±1" 112"1"2" TYP1"1"Á½" RTNT&B 1"6"3S7.10 PANEL BASE PLATE CONNECTION DETAIL 1"=1'-0" ELEVATION VIEW BEAM AND NAILER,SEE PLAN ¢ÅX3" W/2-¼"ØX3½" SDS(MIN) INTO NAILERBELOW  HSS TO MATCH (E)SCEEN FRAME,HSS1½X1½XÁ" MIN (E) COLUMN (E) SCREEN (N) TO MATCHEXISTING SCREEN,SEE ARCH Á 3"TOP, BOTT,&MID-HEIGHT 1"2"Á ¡ SEE AR C H 1"TYP 1"TYP6"2"EQ.EQ. 11" MAX 112" TYP SIDE ELEVATION ¢ÅX6" W/2-¼"ØX4½"SDS INTONAILER HSS TO MATCH (E)SCEEN FRAME,HSS1½X1½XÁ" MIN 2"1"1" COLUMNDIAMETER WORKABLEGUAGE 12"¼TYPEQEQ1½"É"Ø EPOXY BOLTS @16" FULL HEIGHT OFCHANNEL POST,6" MIN EMBED ¢ ¼"X2Â" TYP 4-½"ØTHREADED RODANCHOR BOLTS 12" TYP ¾"34"312"438"B-PIPE COL CAP A-PIPE COL BASEPLATE B-CHANNEL COL CAP  A-CHANNEL COL BASEPLATE 1½" GROUTTOP OF CONCRETE ANCHOR RODS GR.36 U.O.N. ¢ ½"4" MINEMBED4S7.10 PIPE COLUMN CONNECTION AT DOOR HEADER 1"=1'-0" 6S7.10 CHANNEL COLUMN CONNECTION AT DOOR HEADER 1"=1'-0" (E) WT COLUMN DOOR FRAME, SAD W6X25 HDR FINISH WALL CHIP OUT CORNER OF CMU WALLTO ACCOMIDATE NEW HDR PIPE COLUMN CONNDETAILS PER 4S7.10 CHANNEL COLUMN CONNDETAILS PER 6S7.10 GROUT UNDER 'T' BEAMWHERE BEARING ON (N) HDR1½" GROUTTOP OF CONCRETE ANCHOR RODS GR.36 U.O.N. ¢ ½X3-1/2X7"4" MINEMBED2-½"ØTHREADED RODANCHOR BOLTS¼GRINDFLAT ¼114"0" STEE PROJEC ISSUE PROJEC SCALE SHEET 1604 AS S SEAL ASP PAV 01-28-2 ! 1-30-19 Provide a signedspecial inspectionagreement form forthe structural steelwelding, bolting, andepoxy anchors.