HomeMy WebLinkAboutFile Documents.617 E Cooper Ave.0045.2018 (3).ACBK04/23/2018
1/3 6-12-17 Version # 8
PRODUCT DATA SHEET
SARNAFIL® G410 ROOF MEMBRANE
__48 __60 __72 __80__FELTBACK
Sarnafil G410 Roof Membrane is a PVC thermoplastic membrane produced with an integral fiberglass mat reinforcement for excellent
dimensional stability, guaranteed for thickness, with heat-weldable seams, and a unique lacquer coating applied to the top of the
membrane to reduce dirt pick up.
PRODUCT INFORMATION
USES
Sarnafil G410 Roof Membrane is used in adhered applications with various
adhesives over various substrates.
AREAS OF APPLICATION
New Roofs
Reroofs
Flashings
FEATURES / BENEFITS
Excellent dimensional stability
Factory applied lacquer coated to reduce dirt pick up
Hot-air welded seams for long-term performance
Proven membrane performance
Guaranteed thickness
Heat welded seams
Superior fire resistance
TESTS CODES / APPROVALS
FM Global
Underwriters Laboratories
Underwriters Laboratories of Canada
ICC Code Compliance – ESR 1157
Miami-Dade County / Florida Building Code
NSF/ANSI 347: Platinum Certified
PRODUCT DATA
FORM COMPOSITION
High-quality, PVC membrane containing ultraviolet light stabilizers, flame
retardant, and fiberglass reinforcement with a unique lacquer coating on the
top surface.
04/23/2018
Product Data Sheet North America
Sarnafil G410 Membrane
6-12-17, VERSION #8
2/3
COLOR*
Top: Copper Brown, Evergreen, and Lead Gray
Bottom: Gray
PACKAGING
48 mil (1.2 mm) Membrane*
Bareback: 6.56 ft x 65.6 ft (2 m x 20 m) roll,
133 lbs (60 kg) per roll, 19 rolls per pallet
3.25 ft x 65.6 ft (1 m x 20 m) roll,
63 lbs (29 kg) per roll, 20 rolls per pallet
Feltback: 6.56 ft x 65.6 ft (2 m x 20 m) roll,
157 lbs (71 kg) per roll, 15 rolls per pallet
* Made to order, minimum volume required, extended production lead
times. Consult with Sika – Roofing representative for further information.
60 mil (1.5 mm) Membrane
Bareback: 6.56 ft x 65.6 ft (2 m x 20 m) roll,
168 lbs (76 kg) per roll, 19 rolls per pallet
Coverstrip: 8 in x 100 ft (20 cm x 30 m) roll, 25 lbs (11 kg) per roll
Feltback: 6.56 ft x 65.6 ft (2 m x 20 m) roll,
190 lbs (86 kg) per roll, 10 rolls per pallet
72 / 80 mil (1.8 / 2.0 mm) Membrane
Bareback: 6.56 ft x 49.2 ft (2 m x 15 m) rolls,
152 / 168 lbs (69 / 76 kg) per roll, 19 rolls per pallet
Feltback: 6.56 ft x 49.2 ft (2 m x 15 m) rolls,
170 / 185 lbs (77 / 84 kg) per roll, 10 rolls per pallet
STORAGE STORAGE CONDITIONS
Store rolls on pallets and fully protected from the weather with clean canvas
tarpaulins. Unvented polyethylene tarpaulins are unacceptable due to the
accumulation of moisture beneath the tarpaulin in certain weather conditions
that may affect membrane weldability.
TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES*
Property
ASTM
Test
Method
ASTM Type II
D-4434 Spec.
Requirement
Typical Results
Overall Thickness, mil D751 45 48 60 72 80
Thickness Over Scrim, mil -- 16 22 27 35 40
Reinforcing Material -- -- Fiberglass
Felt Weight, oz/yd2
(feltback membrane only) -- -- 9 9 9 9
Breaking Strength, lbf/in (N) D751 55 (245) 60 (267) 80 (356) 100 (445) 110 (489)
Elongation at Break, %
M. D.1 & C.M.D.1 D751 250 & 220 250 &
220
250 &
220
250 &
220
250 &
220
Seam Strength, % of original2 D751 75 Pass Pass Pass Pass
Retention of Properties After
Heat Aging D3045 -- -- -- -- --
Tensile Strength, % of original D751 90 Pass Pass Pass Pass
Elongation, % of original D751 90 Pass Pass Pass Pass
Tearing Resistance, lbf (N) D1004 10 (45) 15 (67) 17.5 (78) 20.5 (91) 22 (98)
Low Temperature Bend,
-40°F (-40°C) D2136 Pass Pass Pass Pass Pass
Accelerated Weathering Test, Hours
(Florescent Light UV exposure) G154 5,000 10,000 10,000 10,000 10,000
Cracking (7x magnification) -- None None None None None
04/23/2018
Product Data Sheet North America
Sarnafil G410 Membrane
6-12-17, VERSION #8
3/3
Discoloration (by observation) -- Negligible Negligible
Crazing (7x magnification) -- None None None None None
Linear Dimensional Change, % D1204 0.1 -0.02 -0.02 -0.01 -0.01
Weight Change After Immersion
in Water, % D570 ± 3.0 2.4 1.9 1.8 1.7
Static Puncture Resistance, lbf (kg) D5602 33 (15) Pass Pass Pass Pass
Dynamic Puncture Resistance,
ft-lbf (J) D5635 7.3 (10) Pass Pass Pass Pass
* Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test
methods, actual site conditions, and curing conditions.
1 M.D. = Machine Direction, C.M.D. = Cross Machine Direction
2 Failure occurs through membrane rupture not seam failure.
SYSTEM INFORMATION
APPLICATION INSTRUCTIONS APPLICATION
Sarnafil G410 is installed after proper preparation of the approved
substrate. The membrane is unrolled into Sarnacol adhesive in accordance
with Sika’s technical requirements and then pressed into place with a
minimum 100 lb (45 kg) steel roller. Sarnafil G410 seams are heat-welded
together by trained operators using hot-air welding equipment. Different
Sarnacol adhesives require different application methods. Please consult
Sika’s Specifications or Applicator Handbook for detailed installation
procedures.
AVAILABILITY From Sika Authorized Applicators when used within Sarnafil roofing and
waterproofing systems.
MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings,
drains and termination sealants at least twice a year and after each storm.
WARRANTY Upon successful completion of the installed roof by the Sika Authorized
Applicator, Sika Corporation will provide a warranty to the Building Owner
via the Sika Authorized Applicator.
LEGAL NOTES All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any
recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika’s current
experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance
with Sika’s instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site
conditions and other factors outside of Sika’s control are such that Sika assumes no liability for the provision of such
information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or
arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the
Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full
application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika
product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-
451-2504.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s
most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or
by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of
the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data
Sheet, product label and Safety Data Sheet prior to product use.
Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the
technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of
product for intended use and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of
product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL
DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT
OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
SIKA CORPORATION – ROOFING UNITED STATES
100 Dan Road
Canton, MA 02021
800-451-2504 (p)
781-828-5365 (f)
usa.sarnafil.sika.com
webmaster.sarnafil@us.sika.com
SIKA CANADA INC.
6915 Davand Drive
Mississauga, ON L5T 1L5
905-795-3177 (p)
905-795-3192 (f)
can.sika.com
marketing.construction@ca.sika.com
04/23/2018
1/3 04-12-17 Version #3
PRODUCT DATA SHEET
SARNATHERM® - 20 psi
Sarnatherm is a rigid closed cell polyisocyanurate insulation board with fiber reinforced felt facers. Sarnatherm is suitable for use in
new construction and re-roofing with Sarnafil® or Sikaplan® membranes.
PRODUCT INFORMATION
USES
Wherever insulation is required within a conventional roof assembly to achieve
specified thermal resistance.
AREAS OF APPLICATION
New Roofs
Recover Roofs
Mechanically Fastened Systems
Adhered Systems
FEATURES / BENEFITS
Manufactured with no CFCs or HCFCs
Virtually no GWP (global warming potential)
Zero ODP (ozone depletion potential)
Compatible with Sarnafil and Sikaplan membranes
CODES / APPROVALS
ASTM C 1289 Type II, Class 1, Grade 2 (20 psi)
UL 1256, 790, 263
FM 4450, 4470
Miami-Dade County
State of Florida
PRODUCT DATA
COMPOSITION
Polyisocyanurate Foam Core
Fiber Reinforced Felt Facers
COLOR
Off-White Core with Black Facer
04/23/2018
Product Data Sheet North America
Sarnatherm – 20 psi Insulation
04-12-17, VERSION #3
2/3
PACKAGING
4’ x 4’ (1.2 m x 1.2 m)
4’ x 8’ (1.2 m x 2.4 m)
Various Thicknesses
STORAGE STORAGE CONDITIONS
Factory-applied packaging is intended only for protection during transit. When
stored outdoors or on the job site, the insulation should be stacked on pallets at
least 4 in (102 mm) above ground level and completely covered with a weatherproof
covering such as a tarpaulin. The temporary factory-applied packaging should be slit
or removed to prevent accumulation of condensation. Refer to PIMA Technical
Bulletin 109: Storage and Handling Recommendations for Polyiso Roof Insulation.
TECHNICAL DATA
TYPICAL PHYSICAL PROPERTIES*
Property ASTM Test Method Results
Compressive Strength D 1621 20 psi (138 kPa)
Dimensional Stability D 2126 < 2 %
Water Absortion C 209 < 1.5 %
Water Vapor Transmission E 96 < 1.5 perm (85.5 ng / (Pa●s●m2))
Flame Spread E 84 (10 min.) 25-60**
Smoke Development E 84 (10 min.) 50-170**
Service Temperature - -100° to 250° F
(-73° to 121° C)
*Physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are
subject to normal manufacturing variation.
**Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of ≤ 75 and smoke
development ≤ 450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic insulation when used in
FM 4450 or UL 1256.
THERMAL DATA
LTTR Value* Thickness Flute Spanability
in mm in mm
5.7 1.0 25 2 - 5/8 66.68
8.6 1.5 38 4 - 3/8 111.13
10.3 1.8 46 4 - 3/8 111.13
11.4 2.0 51 4 - 3/8 111.13
14.4 2.5 64 4 - 3/8 111.13
15.0 2.6 66 4 - 3/8 111.13
17.4 3.0** 76 4 - 3/8 111.13
20.5 3.5** 89 4 - 3/8 111.13
23.6 4.0** 102 4 - 3/8 111.13
*LTTR (long term thermal resistance) values are based on ASTM C 1289. Test samples were third-party selected and tested by an
accredited material testing laboratory. The LTTR results were reviewed by FM Global and certified by the PIMA Quality Mark
Program.
**Use multiple layers when the total desired or specified R-value requires an insulation thickness greater than 2.7 in (68.58 mm).
04/23/2018
Product Data Sheet North America
Sarnatherm – 20 psi Insulation
04-12-17, VERSION #3
3/3
SYSTEM INFORMATION
INSTALLATION
Sarnatherm is installed by a Sika Authorized Applicator. Sarnatherm may be
installed by mechanical-attachment to the roof deck with Sarnafasteners and
Sarnaplates, by attachment with Sarnacol Board Adhesive, or by hot asphalt
depending on project requirements and specifications. Roof insulation which has
become wet or damaged should be removed and replaced with solid, dry insulation.
Contact Sika Corporation – Roofing Technical Department regarding alternative
methods of attachment.
MAINTENANCE
Standard maintenance of roofs should include regular inspection of flashings, drains
and termination sealants at least twice a year and after each storm.
WARRANTY
As a Sika supplied product, Sarnatherm is covered under Sika Corporation
warranties.
LEGAL NOTES All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and
advice relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its
products when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the
differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are
such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products,
nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions
related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose
before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice.
All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling
800-451-2504.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most current
Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical
Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the
warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior
to product use.
Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical
properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use
and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of
labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL
NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL
PROPERTY RIGHTS HELD BY OTHERS.
SIKA CORPORATION – ROOFING UNITED STATES
100 Dan Road
Canton, MA 02021
800-451-2504 (p)
781-828-5365 (f)
usa.sarnafil.sika.com
webmaster.sarnafil@us.sika.com
SIKA CANADA INC.
6915 Davand Drive
Mississauga, ON L5T 1L5
905-795-3177 (p)
905-795-3192 (f)
can.sika.com
marketing.construction@ca.sika.com
04/23/2018