Loading...
HomeMy WebLinkAboutFile Documents.617 E Cooper Ave.0045.2018 (3).ACBK04/23/2018 1/3 6-12-17 Version # 8 PRODUCT DATA SHEET SARNAFIL® G410 ROOF MEMBRANE __48 __60 __72 __80__FELTBACK Sarnafil G410 Roof Membrane is a PVC thermoplastic membrane produced with an integral fiberglass mat reinforcement for excellent dimensional stability, guaranteed for thickness, with heat-weldable seams, and a unique lacquer coating applied to the top of the membrane to reduce dirt pick up. PRODUCT INFORMATION USES Sarnafil G410 Roof Membrane is used in adhered applications with various adhesives over various substrates. AREAS OF APPLICATION  New Roofs  Reroofs  Flashings FEATURES / BENEFITS  Excellent dimensional stability  Factory applied lacquer coated to reduce dirt pick up  Hot-air welded seams for long-term performance  Proven membrane performance  Guaranteed thickness  Heat welded seams  Superior fire resistance TESTS CODES / APPROVALS  FM Global  Underwriters Laboratories  Underwriters Laboratories of Canada  ICC Code Compliance – ESR 1157  Miami-Dade County / Florida Building Code  NSF/ANSI 347: Platinum Certified PRODUCT DATA FORM COMPOSITION High-quality, PVC membrane containing ultraviolet light stabilizers, flame retardant, and fiberglass reinforcement with a unique lacquer coating on the top surface. 04/23/2018 Product Data Sheet North America Sarnafil G410 Membrane 6-12-17, VERSION #8 2/3 COLOR*  Top: Copper Brown, Evergreen, and Lead Gray  Bottom: Gray PACKAGING  48 mil (1.2 mm) Membrane* Bareback: 6.56 ft x 65.6 ft (2 m x 20 m) roll, 133 lbs (60 kg) per roll, 19 rolls per pallet 3.25 ft x 65.6 ft (1 m x 20 m) roll, 63 lbs (29 kg) per roll, 20 rolls per pallet Feltback: 6.56 ft x 65.6 ft (2 m x 20 m) roll, 157 lbs (71 kg) per roll, 15 rolls per pallet * Made to order, minimum volume required, extended production lead times. Consult with Sika – Roofing representative for further information.  60 mil (1.5 mm) Membrane Bareback: 6.56 ft x 65.6 ft (2 m x 20 m) roll, 168 lbs (76 kg) per roll, 19 rolls per pallet Coverstrip: 8 in x 100 ft (20 cm x 30 m) roll, 25 lbs (11 kg) per roll Feltback: 6.56 ft x 65.6 ft (2 m x 20 m) roll, 190 lbs (86 kg) per roll, 10 rolls per pallet  72 / 80 mil (1.8 / 2.0 mm) Membrane Bareback: 6.56 ft x 49.2 ft (2 m x 15 m) rolls, 152 / 168 lbs (69 / 76 kg) per roll, 19 rolls per pallet Feltback: 6.56 ft x 49.2 ft (2 m x 15 m) rolls, 170 / 185 lbs (77 / 84 kg) per roll, 10 rolls per pallet STORAGE STORAGE CONDITIONS Store rolls on pallets and fully protected from the weather with clean canvas tarpaulins. Unvented polyethylene tarpaulins are unacceptable due to the accumulation of moisture beneath the tarpaulin in certain weather conditions that may affect membrane weldability. TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES* Property ASTM Test Method ASTM Type II D-4434 Spec. Requirement Typical Results Overall Thickness, mil D751 45 48 60 72 80 Thickness Over Scrim, mil -- 16 22 27 35 40 Reinforcing Material -- -- Fiberglass Felt Weight, oz/yd2 (feltback membrane only) -- -- 9 9 9 9 Breaking Strength, lbf/in (N) D751 55 (245) 60 (267) 80 (356) 100 (445) 110 (489) Elongation at Break, % M. D.1 & C.M.D.1 D751 250 & 220 250 & 220 250 & 220 250 & 220 250 & 220 Seam Strength, % of original2 D751 75 Pass Pass Pass Pass Retention of Properties After Heat Aging D3045 -- -- -- -- -- Tensile Strength, % of original D751 90 Pass Pass Pass Pass Elongation, % of original D751 90 Pass Pass Pass Pass Tearing Resistance, lbf (N) D1004 10 (45) 15 (67) 17.5 (78) 20.5 (91) 22 (98) Low Temperature Bend, -40°F (-40°C) D2136 Pass Pass Pass Pass Pass Accelerated Weathering Test, Hours (Florescent Light UV exposure) G154 5,000 10,000 10,000 10,000 10,000 Cracking (7x magnification) -- None None None None None 04/23/2018 Product Data Sheet North America Sarnafil G410 Membrane 6-12-17, VERSION #8 3/3 Discoloration (by observation) -- Negligible Negligible Crazing (7x magnification) -- None None None None None Linear Dimensional Change, % D1204 0.1 -0.02 -0.02 -0.01 -0.01 Weight Change After Immersion in Water, % D570 ± 3.0 2.4 1.9 1.8 1.7 Static Puncture Resistance, lbf (kg) D5602 33 (15) Pass Pass Pass Pass Dynamic Puncture Resistance, ft-lbf (J) D5635 7.3 (10) Pass Pass Pass Pass * Results may differ based upon statistical variations depending upon mixing methods and equipment, temperature, application methods, test methods, actual site conditions, and curing conditions. 1 M.D. = Machine Direction, C.M.D. = Cross Machine Direction 2 Failure occurs through membrane rupture not seam failure. SYSTEM INFORMATION APPLICATION INSTRUCTIONS APPLICATION Sarnafil G410 is installed after proper preparation of the approved substrate. The membrane is unrolled into Sarnacol adhesive in accordance with Sika’s technical requirements and then pressed into place with a minimum 100 lb (45 kg) steel roller. Sarnafil G410 seams are heat-welded together by trained operators using hot-air welding equipment. Different Sarnacol adhesives require different application methods. Please consult Sika’s Specifications or Applicator Handbook for detailed installation procedures. AVAILABILITY From Sika Authorized Applicators when used within Sarnafil roofing and waterproofing systems. MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY Upon successful completion of the installed roof by the Sika Authorized Applicator, Sika Corporation will provide a warranty to the Building Owner via the Sika Authorized Applicator. LEGAL NOTES All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800- 451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION – ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com 04/23/2018 1/3 04-12-17 Version #3 PRODUCT DATA SHEET SARNATHERM® - 20 psi Sarnatherm is a rigid closed cell polyisocyanurate insulation board with fiber reinforced felt facers. Sarnatherm is suitable for use in new construction and re-roofing with Sarnafil® or Sikaplan® membranes. PRODUCT INFORMATION USES Wherever insulation is required within a conventional roof assembly to achieve specified thermal resistance. AREAS OF APPLICATION  New Roofs  Recover Roofs  Mechanically Fastened Systems  Adhered Systems FEATURES / BENEFITS  Manufactured with no CFCs or HCFCs  Virtually no GWP (global warming potential)  Zero ODP (ozone depletion potential)  Compatible with Sarnafil and Sikaplan membranes CODES / APPROVALS  ASTM C 1289 Type II, Class 1, Grade 2 (20 psi)  UL 1256, 790, 263  FM 4450, 4470  Miami-Dade County  State of Florida PRODUCT DATA COMPOSITION  Polyisocyanurate Foam Core  Fiber Reinforced Felt Facers COLOR Off-White Core with Black Facer 04/23/2018 Product Data Sheet North America Sarnatherm – 20 psi Insulation 04-12-17, VERSION #3 2/3 PACKAGING  4’ x 4’ (1.2 m x 1.2 m)  4’ x 8’ (1.2 m x 2.4 m)  Various Thicknesses STORAGE STORAGE CONDITIONS Factory-applied packaging is intended only for protection during transit. When stored outdoors or on the job site, the insulation should be stacked on pallets at least 4 in (102 mm) above ground level and completely covered with a weatherproof covering such as a tarpaulin. The temporary factory-applied packaging should be slit or removed to prevent accumulation of condensation. Refer to PIMA Technical Bulletin 109: Storage and Handling Recommendations for Polyiso Roof Insulation. TECHNICAL DATA TYPICAL PHYSICAL PROPERTIES* Property ASTM Test Method Results Compressive Strength D 1621 20 psi (138 kPa) Dimensional Stability D 2126 < 2 % Water Absortion C 209 < 1.5 % Water Vapor Transmission E 96 < 1.5 perm (85.5 ng / (Pa●s●m2)) Flame Spread E 84 (10 min.) 25-60** Smoke Development E 84 (10 min.) 50-170** Service Temperature - -100° to 250° F (-73° to 121° C) *Physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. **Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of ≤ 75 and smoke development ≤ 450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic insulation when used in FM 4450 or UL 1256. THERMAL DATA LTTR Value* Thickness Flute Spanability in mm in mm 5.7 1.0 25 2 - 5/8 66.68 8.6 1.5 38 4 - 3/8 111.13 10.3 1.8 46 4 - 3/8 111.13 11.4 2.0 51 4 - 3/8 111.13 14.4 2.5 64 4 - 3/8 111.13 15.0 2.6 66 4 - 3/8 111.13 17.4 3.0** 76 4 - 3/8 111.13 20.5 3.5** 89 4 - 3/8 111.13 23.6 4.0** 102 4 - 3/8 111.13 *LTTR (long term thermal resistance) values are based on ASTM C 1289. Test samples were third-party selected and tested by an accredited material testing laboratory. The LTTR results were reviewed by FM Global and certified by the PIMA Quality Mark Program. **Use multiple layers when the total desired or specified R-value requires an insulation thickness greater than 2.7 in (68.58 mm). 04/23/2018 Product Data Sheet North America Sarnatherm – 20 psi Insulation 04-12-17, VERSION #3 3/3 SYSTEM INFORMATION INSTALLATION Sarnatherm is installed by a Sika Authorized Applicator. Sarnatherm may be installed by mechanical-attachment to the roof deck with Sarnafasteners and Sarnaplates, by attachment with Sarnacol Board Adhesive, or by hot asphalt depending on project requirements and specifications. Roof insulation which has become wet or damaged should be removed and replaced with solid, dry insulation. Contact Sika Corporation – Roofing Technical Department regarding alternative methods of attachment. MAINTENANCE Standard maintenance of roofs should include regular inspection of flashings, drains and termination sealants at least twice a year and after each storm. WARRANTY As a Sika supplied product, Sarnatherm is covered under Sika Corporation warranties. LEGAL NOTES All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most current Product Data Sheet, product label and Safety Data Sheet which are available online at usa.sarnafil.sika.com or by calling Sika's Technical Service Department at 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Product Data Sheet, product label and Safety Data Sheet prior to product use. Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. SIKA CORPORATION – ROOFING UNITED STATES 100 Dan Road Canton, MA 02021 800-451-2504 (p) 781-828-5365 (f) usa.sarnafil.sika.com webmaster.sarnafil@us.sika.com SIKA CANADA INC. 6915 Davand Drive Mississauga, ON L5T 1L5 905-795-3177 (p) 905-795-3192 (f) can.sika.com marketing.construction@ca.sika.com 04/23/2018