Loading...
HomeMy WebLinkAboutFile Documents.613 E Cooper Ave.0056.2019 (3).ACBKCOMcheck Software Version COMcheck-Web Envelope Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Location:Aspen, Colorado Climate Zone:7 Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: LOCAL CLUB Building Area Floor Area 1-Retail : Nonresidential 788 Envelope Assemblies Project Notes Removing 3 existing recessed can lights and adding 6 sconces and 3 chandeliers. All other lighting to remain. Envelope TBD: No envelope assemblies specified Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 81 ofPage bg Design/Rudd ConstructionCandice Carpenter-Olson614 E. Cooper Ave, Aspen, CO 81611 06/24/2019 COMcheck Software Version COMcheck-Web Interior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: LOCAL CLUB Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 1-RETAIL SPACE (Retail:Sales Area)788 1.59 1253 1253Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture RETAIL SPACE (Retail: Sales Area, 788 sq.ft.) LED: existing recessed cans: LED MR 7W:1 46 7 322 Incandescent: refurbished chandelier: Incandescent 40W:8 1 320 320 Incandescent: refurbished chandelier: Incandescent 40W:6 1 240 240 Incandescent: refurbished chandelier: Incandescent 60W:4 1 240 240 LED: Wall sconce 2: LED MR 4W:1 3 12 36 LED: Wall sconce 1: LED MR 7W:1 3 21 63 1221Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 82 ofPage 5/29/19Beth Fults Osburn - Designer 06/24/2019 COMcheck Software Version COMcheck-Web Exterior Lighting Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: LOCAL CLUB 0 (Unspecified)Exterior Lighting Zone Allowed Exterior Lighting Power A Area/Surface Category B Quantity C Allowed Watts / D Tradable Wattage E Allowed Watts (B X C) Total Tradable Watts (a) = Total Allowed Watts = Total Allowed Supplemental Watts (b) = 0 0 500 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 500 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Exterior lighting zone not specified (see project screen) Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 83 ofPage06/24/2019 COMcheck Software Version COMcheck-Web Mechanical Compliance Certificate Project Title: 2015 IECC Project Type:Alteration Location:Aspen, Colorado Climate Zone:7 Construction Site:Owner/Agent:Designer/Contractor: Project Information Energy Code: LOCAL CLUB Mechanical Systems List Quantity System Type & Description Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 84 ofPage06/24/2019 Inspection Checklist Requirements: 100.0% were addressed directly in the COMcheck software COMcheck Software Version COMcheck-Web Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Plan Review Complies?Comments/Assumptions C103.2 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 85 ofPage06/24/2019 Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1 [EL18]1 Occupancy sensors installed in required spaces. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.1, C405.2.2. 3 [EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.2. 1 [EL22]2 Automatic controls to shut off all building lighting installed in all buildings. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3 [EL16]2 Daylight zones provided with individual controls that control the lights independent of general area lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3, C405.2.3. 1, C405.2.3. 2 [EL20]1 Primary sidelighted areas are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting controls. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 86 ofPage06/24/2019 Section # & Req.ID Final Inspection Complies?Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable Requirement will be met. C405.4.1 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. C408.2.5. 1 [FI16]3 Furnished as-built drawings for electric power systems within 90 days of system acceptance. Complies Does Not Not Observable Not Applicable Requirement will be met. C408.3 [FI33]1 Lighting systems have been tested to ensure proper calibration, adjustment, programming, and operation. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 87 ofPage06/24/2019 Project Title: Data filename: LOCAL CLUB 05/10/19Report date: 88 ofPage06/24/2019