Loading...
HomeMy WebLinkAboutFile Documents.613 E Cooper Ave.0056.2019 (14).ACBK ProBuilder 42 & 54 Linear (MV/GSB2) Installation Manual WARNING: FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Leave the building immediately • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. Tested and Listed by (42) Report # 0028GF105S (54) Report # 0028GF105S REV. 002 Omni-Test Laboratories, Inc. Portland, Oregon ANSI Z21.88-2016 CSA 2.33-2016  Built-In Direct Vent Fireplace  Natural Gas or Propane  Residential or Mobile Home This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. A conversion kit is supplied with the appliance. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. French language manuals at travisindustries.com Manuels de langue Française à travisindustries.com Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com  Copyright 2018, T.I. $10.00 1/2/19 100-01453 06/24/2019 2 Introduction © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 0BOverview This manual details the installation requirements for the Pro Builder Linear fireplace. For operating and maintenance instructions, refer to the Pro Builder Linear mV Owner's Manual. 1BListing Details This appliance was listed by Omni Test Labs to ANSI Z21.88. The listing label is attached to the appliance near the gas control valve. A copy is shown on the next page. Massachusetts Approval This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters. National Fireplace Institute 06/24/2019 Table of Contents 3 © Travis Industries 1/2/19 - 1453 PB 42 MV/GSB2 Install 0BOverview ................................................................... 2  1BListing Details ........................................................... 2  Installation Options .................................................. 6  Heating Specifications ............................................. 6  Dimensions ............................................................... 6  Packing List .............................................................. 7  Additional Items Required ....................................... 7  Recommended Installation Procedure ................... 7  Massachusetts Requirements ................................ 8  Requirements for the Commonwealth of Massachusetts .................................................................8  MANUFACTURER REQUIREMENTS .............................8  Fireplace Placement Requirements ....................... 9  Clearances ......................................................................9  Raised Fireplaces ............................................................9  Televisions Placed Above the Fireplace ................ 10  Minimum Framing Dimensions ............................... 11  Standoff Assembly ................................................... 12  Nailing Brackets ....................................................... 13  Standard vs. Extended Position ............................. 14  Header and Pipe Shield Installation ....................... 15  Corner Installations .................................................. 19  Outdoor fireplace installations ............................... 20  Removing the Front Panel ....................................... 21  Gas Line Requirements ........................................... 22  Fuel .................................................................................22  Gas Line Connection .......................................................22  Gas Inlet Pressure ...........................................................22  Gas Line Location ............................................................23  Relocating the Gas Line to the Baseplate ...................... 23   Electrical Connection ............................................... 24  Relocating the Electrical Line to the Baseplate .............. 24  Optional Wall Switch or Thermostat Installation .. 25  Parallel Connection Series Connection ...................25  Vent Requirements ................................................... 26  Vent Clearances ..............................................................26  Vent Firestop or Thimble .................................................26  Altitude Considerations ....................................................26  Approved Vent .................................................................26  Vent Installation ...............................................................27  Approved Vent Configurations ............................... 27  Exhaust Restrictor Position..............................................27  Diffuser ............................................................................28  Vent Configurations for 42 PB ONLY For 54 PB see page 32 ............................................................... 29  Minimum Vent Configuration ...........................................29  Vent Configuration: Vertical Termination for 42 PB ONLY ...............................................................................30  Vent Configuration: Horizontal Termination with Vertical Rise for 42 PB ONLY ..........................................31  Vent Configurations for 54 PB ONLY For 42 PB see page 29 ............................................................... 32  Minimum Vent Configuration ........................................... 32  Vent Configuration: Vertical Termination for 54 PB ONLY............................................................................... 33  Vent Configuration: Horizontal Termination with Vertical Rise for 54 PB ONLY .......................................... 34  Masonry Chimney Conversions .............................. 35  Class A Chimney Conversion ................................. 36  Termination Requirements ...................................... 37   Hearth Requirements ............................................... 38  Facing Requirements ............................................... 39  Standard vs. Extended Position ...................................... 40  Facing Thicker than 1-1/2”. .............................................. 41  Screen Assembly Mounts ................................................ 42  Do Not Drill or Screw Zone .............................................. 43  Mantel Requirements ............................................... 44  Mantel Column Clearances ............................................. 44  Use of a Non-Combustible Mantel Below Listed Mantel Clearances .................................................... 45  Finalizing the Installation ........................................ 46  MV Units Only - Pilot Flame Inspection - (see instructions on page 49) .................................................. 46  GSB2 Units Only - Pilot Flame Inspection - (see instructions on page 49) .................................................. 46  Air Shutter Adjustment .................................................... 47  Location of Controls ........................................................ 48  MV Units Only - Starting the Pilot .................................... 49  Glass Frame Removal and Installation ............................ 50  Barrier Screen Visual Deflector Adjustment .................... 5 3   Crushed Glass Installation ............................................... 54  LP Conversion Instructions .................................... 56   Wall Mount Remote Thermostat installation (optional) ................................................................... 61  Packing List ..................................................................... 61  Installation ....................................................................... 61  Wiring Diagram – MV Version ................................. 64  Optional Blower Wiring .................................................... 64  Wiring Diagram – GSB2 Version ............................. 65  06/24/2019 4 Safety Precautions © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Safety Warnings  Failure to follow all of the requirements may result in property damage, bodily injury, or even death. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Do not touch the hot surfaces of the heater. Educate all children of the danger of a high-temperature heater. Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies.  This unit must be installed by a qualified installer to prevent the possibility of an explosion.  This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow CSA B149.1.  A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. This appliance may be installed in Manufactured Housing only after the home is site located.  All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure. The venting must not be connected to a chimney flue serving a separate solid-fuel burning appliance.  Notify your insurance company before hooking up this fireplace.  The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing.  This heater is approved for use with natural gas (NG) or propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer.  Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area.  If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call your dealer and arrange for proper servicing.  It is imperative that control compartments, screens, or circulating air passageways of the heater be kept clean and free of obstructions. These areas provide the air necessary for safe operation.  Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call your dealer for a full explanation of your heater and what to expect.  Do not store or use gasoline or other flammable liquids in the vicinity of this heater.  Do not operate if any portion of the heater was submerged in water or if any corrosion occurs. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 06/24/2019 Safety Precautions 5 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Safety Warnings (continued)  Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near the appliance.  Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater.  Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices.  The viewing glass should be opened only for conducting service (or lighting the pilot on millivolt units).  Allow the heater to cool before carrying out any maintenance or cleaning.  Operate the heater according to the instructions included in this manual.  If the main burners do not start correctly turn the gas off and call your dealer for service.  This unit is not for use with solid fuel.  Do not place anything inside the firebox (except the optional artwork).  Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.  Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual.  Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off.  A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.  If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance.  Clothing or other flammable material should not be placed on or near the appliance.  Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating the appliance.  Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning might be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean.  Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s). Proposition 65 Warning: Fuels used in gas, woodburning or oil fired appliances, and the products of combustion of such fuels, contain chemicals known to the State of California to cause cancer, birth defects and other reproductive harm. California Health & Safety Code Sec. 25249.6 Travis Gas Fireplaces. Stoves and Inserts are protected by one or more of the following patents; U.S. 8,469,021, 7,066,170, 6,602,068, 6,443,726, 6,953,037; Canada 2755517 as well as other U.S. and Foreign Patents pending. 06/24/2019 6 Features and Specifications © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Installation Options  Residential or Mobile Home  Straight or Corner Placement  Raised or Floor Placement  Internal or External Chase  Bedroom Approved Heating Specifications Natural Gas Propane 42 ProBuilder Approximate Heating Capacity (in square feet)* Up to 1,250 Up to 1,250 Maximum BTU Input Per Hour 25,000 25,000 54 ProBuilder Approximate Heating Capacity (in square feet)* Up to 1,650 Up to 1,650 Maximum BTU Input Per Hour 33,000 33,000 * Heating capacity will vary with floor plan, insulation, and outside temperature. Dimensions 4-7/8" 124mm Left a' gau c h e Fro n t ava n t Right droit Re a r arri e ' r e 15-7/8" * 404mm * 34-1/2" 877mm * Includes the required 1/2" clearance to each side and rear of the fireplace. 20-1/2" 521mm 31" 788mm 9-3/4" 248mm 1-1/2" 38mm 3-3/4" 96mm 42 PB Linear 47-1/8" (1197mm)* 54 PB Linear 59-1/8" (1502mm)* 42 PB 4 5- 3/ 4" ( 1 1 6 3 m m) 5 4 P B 5 7- 3/ 4" ( 1 4 6 7 m m) 42 PB = 165 lbs. 75 Kg. 54 PB = 210 lbs. 95 Kg. 06/24/2019 Installation (for qualified installers only) 7 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Packing List  LP (Propane) Conversion Kit: (42PB) Burner Orifice (1.45mm), Pilot Orifice (0.14 LP), LP Regulator (54PB) Burner Orifice (1.65mm), Pilot Orifice (0.14 LP), LP Regulator  Thimble (2-Piece Assembly)  Pipe Shield, Header Shield (shipped attached to top of fireplace)  Wall Switch, Cover Plate, and Wire Additional Items Required  Gas Line Equipment (shutoff valve, pipe, etc.)  Electrical Equipment (min. 14 gauge, grounded line)  The 42PB Requires 7 lbs. of 1/4” Crushed Glass  The 54PB Requires 8 lbs. of 1/4” Crushed Glass 94500580 Platinum (10 lbs.) 94500581 Bronze (10 lbs.) 94500582 Cobalt (10 lbs.) 94500583 Black (10 lbs.) Recommended Installation Procedure  Frame the opening for the fireplace. Make sure to allow for vent installation.  Install the vent, gas line and electrical hook-up.  Install the drywall.  Install the hearth (if applicable).  Install the facing (if applicable).  Install the mantel (if applicable).  Finalize the installation (see page 44). 06/24/2019 8 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Massachusetts Requirements NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: Installation of Carbon Monoxide Detectors At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: • The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and • Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: • Detailed instructions for the installation of the venting system design or the venting system components; and • A complete parts list for the venting system design or venting system. Gas Equipment Venting System NOT Provided When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer: • The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and • The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. See Gas Connection section for additional Commonwealth of Massachusetts requirements. 06/24/2019 Installation (for qualified installers only) 9 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Fireplace Placement Requirements  Fireplace must be installed on a level surface capable of supporting the fireplace and vent  Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)  Fireplace should be located out of traffic and away from furniture and avoid burns.  Fireplace must be placed so the gaps below and above the glass frame do not become blocked.  Fireplace may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location. Clearances (a) Clearance to Side of Fireplace 1/2” (13mm). Do not place insulation in this space. NOTE: Drywall (or other combustible) may contact the first ½” of the sides of the fireplace. (b) Clearance to Back of Fireplace 1/2” (13mm). Do not place insulation in this space. (c) When installed, walls in front of the fireplace must be a minimum 0” (0mm) to the side of the fireplace standoffs. Raised Fireplaces  The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace and vent.  The base of the fireplace must be a minimum 60” below the room ceiling. The top of the control door (firebox opening) is approximately 8-3/4” (223mm) above the base of the fireplace. For a typical raised fireplace of 36” (915mm), place the fireplace on a platform 27.25” (693mm) tall. a c b 06/24/2019 10 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Televisions Placed Above the Fireplace The following section gives guidelines to place a television above the fireplace. IMPORTANT NOTE REGARDING TELEVISIONS AND THIS FIREPLACE Most television manufacturers instruct the homeowner not to place the television above a heat source like this fireplace. Doing so may decrease the longevity of the television and negate the warranty. If you do place a television above the fireplace, you should place a mantel (or build-out) between the fireplace and television (or use a CoolSmart TV Wall™ kit). Follow the guidelines below to reduce the amount of heat reaching the television. Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Minimum Dimensions: (a) Minimum Mantel Height above Base of Fireplace* 39” (991mm) with 4” (102mm) mantel depth (b) Minimum Mantel Depth* 4” (102mm)* (c) Optional Columns (or Build-Out) Must Meet Side Wall Clearances (Measured to the side of fireplace ZC-can) * Minimum mantel depth must be 4”(102mm) to allow heat to dissipate. If using a mantel larger than 4”(102mm), make sure to adjust the mantel height (a) to meet the mantel clearancer (see mantel requirements on page 44 for details).  The mantel must extend 2” in front of the television and 1” to both sides.  If you have a television that is greater than 2” deep (including the 1” gap behind), you will need to alter the mantel depth and height (see the example below).  The television must have a 1” gap to the wall to allow for proper cooling. Any build-out near the television must maintain a 3” gap to the top and sides to prevent heat from being trapped near the television. WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring to protect from contact with hot surfaces. Fireplace Min. 1" (26mm) Min. 1" (152mm)Min. 2" (51mm) a b c Optional Column or Build-Out Min. 1" (26mm) Air Gap Behind TV Min. 3" (77mm) Television (TV) IDB01243 (b) Depth (a) Height Above Base of Fireplace 0" (0mm)1" (25mm)2" (51mm)8" (203mm)7" (178mm)6" (152mm)5" (127mm)4" (102mm)3" (76mm)9" (229mm)10" (254mm)11" (279mm)12" (305mm)45" (1143mm) 44" (1118mm) 43" (1093mm) IDB01242PB42,54,72 42" (1067mm) 41" (1042mm) 40" (1016mm) 39" (991mm) 06/24/2019 Installation (for qualified installers only) 11 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Minimum Framing Dimensions The fireplace enclosure must be a minimum 45-1/4” (1150mm) for the 42PB or 54-1/2” (1385mm) tall for the 54PB. Do not build into the fireplace enclosure. 34-1/2" 877mm a42 PB LInear 45-1/4" 1150mm 15-7/8" 404mm 42 PB Linear 47-1/8" (1197mm) 54 PB Linear 59-1/8" (1502mm) 54 PB LInear 54-1/2" 1385mm a 06/24/2019 12 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Standoff Assembly  The side and rear standoffs must be assembled prior to placing the fireplace into position.  These standoffs, when properly constructed, provide a guide for the required 1/2" clearance. NOTE: The rear standoffs are bent around the rear corners of the fireplace as shown below to the right. Rear Standoffs 06/24/2019 Installation (for qualified installers only) 13 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Nailing Brackets The fireplace has nailing brackets on both sides. Secure the fireplace to the framing with the nailing brackets. NOTE: Make sure the fireplace is square and plumb when placed in the framing. Measured corner-to-corner the fireplace should be square. Use shims to insure the fireplace is square. NOTE: The nailing brackets have two positions: standard and extended. See the section “Facing Requirements” for details on which position is best for your installation. Bend the two nailing brackets out (each side) a b Rotate the two nailing brackets out (each side) Secure the fireplace to the framing using the nailing brackets c Extended Position (rotate nailing brackets as shown below) Standard Position (nailing brackets as shown below) NOTE: 2 holes are provided on each side of the fireplace if you wish to secure the base of the fireplace to the floor (platform). 06/24/2019 14 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Standard vs. Extended Position There are two positions that the standoff/heat shield assembly can be installed. The standoffs are shipped in the standard (forward) position.  If the unit is installed in the standard position no modification is needed.  If the unit is being installed in the extended position, the standoff/heat shield assembly must be repositioned back ½” (see illustration below). NOTE: see pages 13 & 40.for additional details about standard vs. extended installations. Standard Position Extended Position 06/24/2019 Installation (for qualified installers only) 15 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Header and Pipe Shield Installation The header and pipe shield must be installed as shown below. NOTE: The header and pipe shields may be installed after the fireplace is in place and vent attached (this allows for the fireplace to fit into the framing underneath the header and for the vent to be installed more easily). 1 Remove the header shield from its shipping location by removing the (2) - ¼” screws attaching it to the back of the fireplace (Keep the screws for reinstallation). 2 At each of the perforations, bend the sides of the pipe shield backwards 90° as shown below. NOTE: The bottom flanges should be facing outward Bend at perforations Tabs face out. 06/24/2019 16 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 3 Remove the (4) screws, (2) from each side of the starter collar. Line up the holes on the pipe shield tabs with the holes from the screws you just removed. Use the screws to attach the pipe shield to the top of the fireplace. Remove screws 06/24/2019 Installation (for qualified installers only) 17 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 4 The (2) header standoffs are screwed down flat to front edge of the top of the fireplace. On each standoff, remove the screw that is closest to the center of the fireplace (keep screw for reinstallation). Bend the legs at the perforations as shown below and attach the foot of the standoff to the top of the fireplace using the screw removed earlier in this step. Remove screw 06/24/2019 18 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 5 On the header shield, bend the two tabs downward approximately 90 degrees. Set the header shield onto the standoffs with the 90° bend facing the pipe shield. The tips of the standoffs will protrude through the heat shield. Attach the heat shield to the standoffs by aligning the holes on the heat shield tabs with the holes in the header standoffs and secure using the included screws 6 When finished the fireplace should be configured like the picture below. Bend tabs down 90° Align holes 06/24/2019 Installation (for qualified installers only) 19 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Corner Installations A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). 42PB 54PB (a) Corner to Wall (minimum) 53-1/2” 1359mm 63-3/4” 1619mm (b) Corner to Center of Flue (typical) 20-3/4” 528mm 25” 635mm Minimum 1/2" (13mm) Clearance a b NOTE ON PIPE SHIELD: When venting in a corner application, one side of the pipe shield may be disconnected from the top of the fireplace and bent at a 45° angle. 06/24/2019 20 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Outdoor fireplace installations Travis Industries Inc. gas-fired fireplaces are suitable for installation into outdoor areas protected from direct water impingement. In addition to maintaining listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of installed appliances (see the illustration to the right). All wiring connections to line power shall be in accordance with outdoor requirements of NECA NFPA 70. A B Side of Fireplace The overhang (A) must extend at least 1/2 the roofline height (B). Height is measured from the base of the fireplace. For example: if the rooline (B) is 8' above the base of the fireplace, the overhang (A) must be at least 4'. 06/24/2019 Installation (for qualified installers only) 21 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Removing the Front Panel The front cover may be removed to access the components. This is required when relocating the electrical or gas inlet location. To remove the front cover (a) Remove the center wingnuts. (b) Loosen the two outer screws. (c) Rotate the front panel down. (d) Remove the front cover. 1/4" Nutdriver/Wrench 06/24/2019 22 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS:  Flexible connector must not be longer than 36 inches.  Shutoff valve must be a “T” handle gas cock.  Only direct vent sealed combustion products are approved for bedrooms or bathrooms.  Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log.  A carbon monoxide (CO) detector is required in the same room as the appliance.  The gas line must be installed in accordance with all local codes and the requirements listed below. In the absence of local codes, follow ANSI 223.1 in US/Canada or AS/NZS 5601.1 in Australia.  The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPA). For pressures under 1/2 psig (3.5 kPA), isolate the gas supply piping by closing the manual shutoff valve.  Leak test all gas line joints and the gas control valve prior to and after starting the fireplace.  This unit has been listed using the included internal gas shutoff valve. Fuel  This fireplace is designed either for natural gas or for propane (but not for both). Gas Line Connection  Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter).  The gas inlet accepts 1/2" MPT. Gas Inlet Pressure Gas Pressure Max. Input Pressure Min. Input Pressure Max. Manifold Pressure Min. Manifold Pressure Natural Gas 7" W.C. (1.74 kPA) 5.5” W.C. (1.37 kPA) 3.8” W.C. (0.95 kPA) 1.1” W.C. (0.27 kPA) Propane 13" W.C. (3.23 kPA) 11” W.C. (2.74 kPA) 11” W.C. (2.74 kPA) 2.9” W.C. (0.72 kPA)  If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.  The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure. MV Version GSB2 Version 06/24/2019 Installation (for qualified installers only) 23 © Travis Industries 2/12/19 - 1453 PB 42 & 54 MV/GSB2 Install Gas Line Location NOTE FOR RIGID PIPE: When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve. Disconnect the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed through the cover plate and the shutoff valve and gas line may be re-attached inside the fireplace. Gas line may be plumbed from the left side (stock) or below. See illustration and table below to determine gas line location. 42 PB - a 42 PB - b 54 PB - a 54 PB - b Left Side Gas Pass-Through Location (Stock) 6-1/4” (159mm) 2-1/2” (64mm) 6-1/4” (159mm) 2-1/2” (64mm) Baseplate Gas Pass-Through Location* 11” (280mm) 21-1/4” (540mm) 10” (254mm) 31-1/8” (791mm) Relocating the Gas Line to the Baseplate 1. Remove the knock-out in the desired location (you may wish to remove both knockouts if routing electrical through the base as well). 2. Route the flex gas line (with shutoff valve) to the desired location. b a b a 06/24/2019 24 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Electrical Connection  The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes.  Make sure the household breaker is shut off prior to working on any electrical lines.  The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.  The electrical line must be a min. 14 gauge, and supply 120 Volts, 60 Hz, and 5.7 Amps.  Route the electrical connection through the junction box cover plate and attach to the hookup wires pictured below. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. a b Electrical Junction Box Location 11” (280mm) 2-1/4” (58mm) Relocating the Electrical Line to the Baseplate Remove the front panel (see page 21). Remove the junction box from the left side (keep the screws). Remove the knockout from the baseplate. Attach the junction box to the baseplate (make sure all wiring is kept from contacting hot or moving components). Attach the cover plate to the left side. 1 2 3 4 ab 06/24/2019 Installation (for qualified installers only) 25 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Optional Wall Switch or Thermostat Installation Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. The switch and wiring must be installed by a qualified installer. This fireplace includes an optional wall switch (with wire) to operate the fireplace burner without accessing the internal on/off switch. A thermostat may be used instead. Route the wire from inside the fireplace, through the grommet on either side of the fireplace (see illustration to the right) to the switch. The wall switch (or thermostat) may bypass the fireplace on/off switch or be installed in parallel or series configuration (see below). Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Warning: Make sure all wiring is secure and does not contact hot or moving components. Parallel Connection Series Connection On / Off Switch ON On / Off Switch OFF On / Off Switch ON On / Off Switch OFF Thermostat / External Switch ON Heater is ON Heater is ON Thermostat / External Switch ON Heater is ON Heater is OFF Thermostat / External Switch OFF Heater is ON Heater is OFF Thermostat / External Switch OFF Heater is OFF Heater is OFF To wire the heater in parallel, follow the directions below: To wire the heater in series, follow the directions below: OPTIONAL WALL SWITCH (included with fireplace) Place "WARNING" label on switch cover. Thermostat (or External Switch) Wires a b c On / Off Switch a On / Off Switch c b Thermostat (or External Switch) Wires 06/24/2019 26 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Requirements  The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use its own separate vent system.  In addition to the requirements listed here, follow the requirements provided with the vent. Drafting Performance This direct vent appliance requires natural draft to operate (similar to a wood stove or other heating appliance). Draft can be adjusted using the included restrictor. The restrictor settings detailed in the manual should be followed (variations may occur depending upon installation parameters). Many factors may negatively influence the draft of the appliance. Travis Industries will not be responsible for improper draft due to factors such as trees, hills, buildings, obstructions, excessive wind, extreme hot or cold outdoor temperatures, restrictive vent terminations, or influence from mechanical systems. Vent Clearances  The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill air spaces with insulation. Minimum Vent Configurations (see page 29) Minimum Clearance Above Vent 1" (26mm) Minimum Clearance to Sides & Below Vent 1" (26mm) NOTE: Make sure to use the included wall thimble with this configuration. All Other Vent Configurations Minimum Clearance to Vent 1" (26mm) Vent Firestop or Thimble  A firestop or thimble is required whenever the vent penetrates a wall, floor, or ceiling (passes through framing members). See vent charts on page 29 and 31 for details Altitude Considerations  This heater has been tested at altitudes ranging from sea level to 6,000 feet (1800 M). In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.  Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter. Approved Vent  Always use the high-wind cap (part # 46DVA-HC, 58DVA-HC, or 46DVA-VCH). The high-wind sconce cap is not allowed.  Installation instructions for Simpson Dura-Vent may be found at www.duravent.com. Minimum Vent Configurations (see page 29) Use 8" diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)*. All Other Vent Configurations Use 8" or 6-5/8” diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)* (see vent configuration for details). * Other vent may be approved with this fireplace. Check with the vent manufacturer for details). 06/24/2019 Installation (for qualified installers only) 27 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Installation  Slide the vent sections together and turn 1/4 turn until the sections lock in place.  Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired.  High temperature sealant is recommended at the appliance starter section connection (use high-temperature silicone or Mill-Pac®).  If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections.  Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel.  Horizontal sections require non-combustible support every three feet (e.g.: plumbing strap).  Vent termination must not be located where it can become plugged by snow or other material.  Use the vinyl siding standoff when installing on a structure with vinyl siding.  Venting termination shall not be recessed into a wall or siding. Approved Vent Configurations Exhaust Restrictor Position  An exhaust restrictor is built into the appliance to adjust the flow rate of exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor position. The charts for vent configurations detail the correct restrictor position. Slide the restrictor to the correct restrictor position (see the illustration below). Screw location indicates restrictor position. In this example, the restrictor is set in position # 5. Tighten the screws to secure the restrictor. # 2... Back of Firebox Back W a l l o f F i r e b o x Firebox R o o f Loosen these 2 screws on the exhaust restrictor. (open - stock position) # 1 # 6... # 11 06/24/2019 28 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Diffuser  A diffuser is built into the appliance to adjust the flow rate of exhaust gases. Depending upon the vent configuration, you may be required to adjust the diffuser to the open position (see illustration below). The charts for vent configurations detail the correct diffuser position. Remove the diffuser. 1/4" Nutdriver Secure the flattened diffuser plate with the screws removed earlier. Bend the round portion of the diffuser so it is flat (open). Before (Closed - Stock) After (Open) DIFFUSER SIDE VIEW 06/24/2019 Installation (for qualified installers only) 29 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configurations for 42 PB ONLY For 54 PB see page 32 Minimum Vent Configuration  Use 5x8” Diameter Coaxial Vent  NOTE: Use the included thimble assembly whenever passing through a wall. (use on front and back of wall penetration). See picture below.  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  One 45° elbow may be used on the horizontal run.  HINT: Use minimum vent kit “H” (96200332) from Travis Industries (additional vent may be required). Use the included wall thimble when penetrating a wall. Part #96200101 3 feet (0.915m) 0 feet 0 feetMax. 20' (6M) Horizontal Section(s) Exhaust Restrictor # 1 (stock) Diffuser Closed (stock)5 feet (1.5 m)10 feet (3 m)15 feet (4.5 m)20' max (6 m)Elbow Placed Directly on Top of Fireplace PB 42 Linear Only 06/24/2019 30 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configuration: Vertical Termination for 42 PB ONLY  Use 4x6-5/8” Diameter Coaxial Vent. Connect a 8” to 6-5/8” reducer directly to the fireplace (sku 98900165).  NOTE: The included thimble assembly is not required and may be discarded.  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  Up to four elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet5 feet (1.5m)0 feet20 feet (6m)20 feet (6m)5 feet (1.5m)10 feet (3m)5 feet (1.5m)10 feet (3m)0 feet 15 feet (4.5m)20 feet (6m)10 feet (3m) 15 feet (4.5m)15 feet (4.5m)20' (6m) max10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m)25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) max25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) maxAttach reducer directly to the fireplace. Exhaust Restrictor # 8 Diffuser Open Exhaust Restrictor # 5 Diffuser Open Exhaust Restrictor # 11 Diffuser Open PB 42 Linear Only PB 42 Linear Only This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 06/24/2019 Installation (for qualified installers only) 31 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configuration: Horizontal Termination with Vertical Rise for 42 PB ONLY  Vent configurations 15’ or above (from the base of the fireplace) use 6-5/8” dia. vent. Connect a 8” to 6-5/8” reducer directly to the fireplace (98900165). NOTE: For this configuration the included thimble assembly is not required and may be discarded.  Vent configurations under 15’ (from the base of the fireplace) use 8” dia. Vent. NOTE: For this configuration the included thimble assembly may be used or use a firestop (not included).  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  Up to four elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet5 feet (1.5m)0 feet20 feet (6m)20 feet (6m)5 feet (1.5m)10 feet (3m)5 feet (1.5m)10 feet (3m)0 feet 15 feet (4.5m)20 feet (6m)10 feet (3m) 15 feet (4.5m)15 feet (4.5m)20' (6m) max10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m)25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) max25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) maxMin. 1' Section of Vent Attached directly to Fireplace Exhaust Restrictor # 11 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 8 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 5 Diffuser Open 8" Vent Exhaust Restrictor # 3 Diffuser Closed (stock) 8" Vent Exhaust Restrictor # 1 Diffuser Closed (stock) 8" Vent Exhaust Restrictor # 5 Diffuser Closed (stock) 8" Vent PB 42 Linear Only PB 42 Linear Only PB 42 Linear Only This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 06/24/2019 32 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configurations for 54 PB ONLY For 42 PB see page 29 Minimum Vent Configuration  Use 5x8” Diameter Coaxial Vent  NOTE: Use the included thimble assembly whenever passing through a wall (use on front and back of wall penetration). See picture below.  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  One 45° elbow may be used on the horizontal run.  HINT: Use minimum vent kit “H” (96200332) from Travis Industries (additional vent may be required). Use the included wall thimble when penetrating a wall. Part #96200101 0 feet 0 feetExhaust Restrictor # 1 (stock) Diffuser Closed (stock) 8" Vent 5 feet (1.5 m)Max. 4' Horizontal Section(s) Min. 3.9" Horizontal Section 5 feet (1.5 m) 1' Vertical Section Attached Directly to Fireplace PB 54 Linear Only 06/24/2019 Installation (for qualified installers only) 33 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configuration: Vertical Termination for 54 PB ONLY  Use 4x6-5/8” Diameter Coaxial Vent. Connect a 8” to 6-5/8” reducer directly to the fireplace (sku 98900165).  NOTE: The included thimble assembly is not required and may be discarded.  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  Up to four elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet5 feet (1.5m)0 feet20 feet (6m)20 feet (6m)5 feet (1.5m)10 feet (3m)5 feet (1.5m)10 feet (3m)0 feet 15 feet (4.5m)20 feet (6m)10 feet (3m) 15 feet (4.5m)15 feet (4.5m)20' (6m) max10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m)25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) max25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) maxExhaust Restrictor # 5 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 4 Diffuser Closed (stock) 8" Vent Exhaust Restrictor # 10 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 6 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 8 Diffuser Open 6-5/8" Vent (place reducer on fireplace) PB 54 Linear Only PB 54 Linear OnlyPB 54 Linear Only This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 06/24/2019 34 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Vent Configuration: Horizontal Termination with Vertical Rise for 54 PB ONLY  Vent configurations 15’ or above (from the base of the fireplace) use 6-5/8” dia. vent. Connect a 8” to 6-5/8” reducer directly to the fireplace (98900165). NOTE: For this configuration, the included thimble assembly is not required and may be discarded.  Vent configurations under 15’ (from the base of the fireplace) use 8” dia. Vent. NOTE: For this configuration, the included thimble assembly may be used or use a firestop (not included).  The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions.  Up to four elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet5 feet (1.5m)0 feet20 feet (6m)20 feet (6m)5 feet (1.5m)10 feet (3m)5 feet (1.5m)10 feet (3m)0 feet 15 feet (4.5m)20 feet (6m)10 feet (3m) 15 feet (4.5m)15 feet (4.5m)20' (6m) max10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m)25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) max25 feet (7.5m)30 feet (9m)35 feet (10.5m)40 feet (12m)45 feet (13.5m)50 feet (15m)55 feet (16.5m)60 feet (18m) maxMin. 1' Section of Vent Attached directly to Fireplace Exhaust Restrictor # 10 Diffuser Open 6-5/8" Vent (place reducer on fireplace) Exhaust Restrictor # 5 Diffuser Open 8" Vent Exhaust Restrictor # 4 Diffuser Closed (stock) 8" Vent Exhaust Restrictor # 1 (stock) Diffuser Closed (stock) 8" Vent 4' Horizontal Exhaust Restrictor # 8 Diffuser Open 6-5/8" Vent (place reducer on fireplace)Exhaust Restrictor # 6 Diffuser Open 6-5/8" Vent (place reducer on fireplace) PB 54 Linear Only PB 54 Linear Only PB 54 Linear Only This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 06/24/2019 Installation (for qualified installers only) 35 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Masonry Chimney Conversions This appliance may utilize 6-5/8" diameter direct vent manufactured by Duravent (reducer may be required). The vent may be adapted to utilize an existing masonry fireplace using the Duravent Co-Linear Adapter (46DVA-GCL or TCL). The vent must be installed following all directions included with the vent and those listed below:  All requirements in the appliance manual must be met. This includes compliance with vent configuration charts.  The restrictor position should be set to the position that most closely resembles the vent configuration. NOTE: because this installation utilizes non- standard vent, the restrictor position may vary. Carefully monitor the burn characteristics to verify correct restrictor position.  The UL gas liner must only be run through the fireplace/chimney (entire length of liner must be retained within the fireplace/chimney). Do not run the liner near combustibles. This appliance may utilize 6-5/8" diameter direct vent manufactured by Duravent (reducer may be required). The vent may be adapted to utilize an existing masonry fireplace using the Duravent Masonry Chimney Conversion Kit (part # 46DVA-KCT). The vent must be installed following all directions included with the vent and those listed below: NOTE: Before proceeding with the following installation example, check with the local building jurisdiction to verify that this type of installation is allowed in your area.  All requirements in the appliance manual must be met. This includes compliance with vent configuration charts.  The restrictor position should be set to the position that most closely resembles the vent configuration. NOTE: because this installation utilizes non- standard vent, the restrictor position may vary. Carefully monitor the burn characteristics to verify correct restrictor position.  The UL gas liner must only be run through the fireplace/chimney (entire length of liner must be retained within the fireplace/chimney). Do not run the liner near combustibles. Coaxial pipe must maintain proper clearances to combustibles (see manual for details). High-Te m p . Silicon e Co-Axial to Co-Linear Adapter must maintain 3" clearance to combustibles Flashing High Wind Termination Direct Vent Direct Vent Fireplace UL Gas Liner The entire chimney system must be air-tight. Make sure to seal the flashing, clean-out, and thimble connection, and to inspect the chimney. 4" Dia. Flex Line (UL 1777 Gas Liner) Flashing (included in #934 Masonry Conversion Kit) Make sure the coaxial pipe maintains the correct clearance to any combustible (see the owner's manual). The vent must be sealed air-tight. High-Te m p . Silicone Connector with Cover (included in #934 Masonry Conversion Kit) 06/24/2019 36 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Class A Chimney Conversion Duravent provides a conversion kit for those wishing to use an existing class A chimney to vent this direct fireplace. The illustration below gives an overview of this type of installation. See the instructions included with the kit for details.  All requirements in the appliance manual must be met. This includes compliance with vent configuration charts.. Remember to set the restrictor position to the correct position (based upon the vertical rise height - see the vent charts in the appliance manual.  These conversion kits does not work on interior masonry chimneys.  The measurements below refer to the Chimney Inside Diameter Chimney Conversion Kit A (46DVA-KCA) 6” DuraTech 6” Security Chimney 6” Metalbestos 6” Jackes-Evans 6” Hart & Cooley 6” Pro-Jet Chimney Conversion Kit B (46DVA-KCB) 6” DuraPlus 7”-8” DuraTech 8” Security Chimneys 7”-8” Metalbestos 7”-8”Jackes-Evans 7”-8”Hart & Cooley 7”-8”Pro-Jet 6”-7” Amer. Metals 6”-7”Metal-Fab 6” Air-Jet Chimney Conversion Kit C (46DVA-KCC) 7”-8” DuraPlus 8” American Metals 8” Air-Jet 8” Metal-Fab Each Kit Contains: Cap Adapter Retro Connector Additional Required Equipment: 4" Flex (#711 or U.L. 1777) Termination (46DVA-VCH) Co-Axial Sections Type A Chimney Duravent DirectVent Pipe Sections (use adjustable section) Screw the Retro Vertical Top to the Flex Pipe Cap Adapter (screw to chimney) Screw the RetroConnector to the Flex Pipe Retro Connector(screw to chimney) 4" (102 mm) Aluminum Flex Pipe Cut the Flex Pipe tothe chimney height plus 3" (76 mm) Fireplace 06/24/2019 Installation (for qualified installers only) 37 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Termination Requirements ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" (229mm) clearance from any door or window B Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony C Minimum 1" (25mm) from outside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. D Minimum 1" (25mm) from inside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. E Minimum 11" (279mm) clearance below unventilated soffits or roof surfaces Minimum 18" (457mm) clearance below ventilated soffits Minimum 6" (152mm) clearance below roof eaves NOTE: Vinyl surfaces require 24" (610mm) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. F Minimum 12" (305mm) clearance below a veranda, porch, deck or balcony NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor. NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. G Minimum 48" (1219mm) clearance from any adjacent building H Minimum 84" (2134mm) clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building I Minimum 9" (229mm) clearance to any non-mechanical air supply inlet to the building or the combustion air inlet to any other appliance. J Minimum 36" (914mm) clearance above any mechanical air supply inlet if within 10’ (3M) horizontally K Minimum 36" (914mm) from the area above the meter/regulator (vent outlet) - this extends 15’ (4.5M) above the regulator NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. L Minimum 36" (914mm) from the meter/regulator (vent outlet) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. M Minimum 12” (305mm) above the roof line (for vertical terminations) N Minimum 24” (610mm) horizontal clearance to any surface (such as an exterior wall) – for vertical terminations 11" Min. (279mm)6" Min. (152mm) Roof Surface Roof Eaves C B H E G A DF L K J I NOTE: Measure clearances to the nearest edge of the exhaust hood. A E E M N 06/24/2019 38 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Hearth Requirements  If installed near carpet or other combustible flooring, the fireplace must be raised so the base of the unit is above the carpet surface or flooring material. If the heater is installed at floor level, we recommend a non- combustible hearth to protect the flooring surface from discoloration or other negative impact from the heater.  A non-combustible hearth may be constructed in front of the fireplace (see illustration below). A non-combustible hearth may be installed in front of the fireplace. The entire structure must be non- combustible. Do not build the hearth above the screen assembly. 06/24/2019 Installation (for qualified installers only) 39 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Facing Requirements  Non-combustible facing must extend from the base of the fireplace to 35-1/2” above the base of the fireplace (see illustration below for details).  Non-combustible facing must extend the entire width of the unit to the framing opening on both sides.  Do not place facing over the glass opening.  Drywall (or other combustible) may be placed above the non-combustible facing (35-1/2” above the base of the fireplace). See illustration below for details. WARNING: Do not place drywall or other combustibles over the front of the fireplace. WARNING: Do not use adhesive to secure the facing. The high temperatures of the fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non- combustible, non-odorous adherent) to attach the facing. NOTE: Screws may be used to secure cement board or tile backer to the fireplace. Do not penetrate the fireplace more than 1/2” (13mm). Ad h e s i v e Min. 5" 127 m m 20-1/8" 512mm Base of Fireplace Minimum 10-3/8" 264mm Non-C o m b u sti bl e Facin g O nl y Minimum 35-1/2" 902mm Minimum 42 Lin. = 47-1/8" 1197mm 54 Lin. = 59-1/8" 1502mm Non-C o m b u sti bl e F a ci n g O nl y Comb u sti bl e F a ci n g Allow e d Framing Header Make sure non-combustible board is cut and positioned so it maintains a 1/8" (3mm) gap from the tile stop. This allows the fireplace structure to expand without cracking the facing (see dimensions below). 1/8" (3mm) 1/8" (3mm) Gap 42 Lin = 4 5" 1 1 4 3 m m 54 Lin = 5 7" 1 4 4 8 m m 06/24/2019 40 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Standard vs. Extended Position  The nailing brackets on the side of the fireplace may be placed in the standard or extended position to best suit the facing being used (the header shield is also moved). Most installations use the standard nailing bracket position. If using a facing that does not use a backing board (e.g. marble), you may wish to use the extended position. Standard Position - Top View (nailing brackets as shown to right) Optional Tile (or other non-combustible) Drywall Cement Board (or other non-combustible) Nailing Bracket Fireplace Framing Non-Combustible Facing (marble, etc.) Drywall Nailing Bracket Fireplace Framing Extended Position - Top View (nailing brackets as shown to right) Nailing Bracket Nailing Bracket 06/24/2019 Installation (for qualified installers only) 41 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Facing Thicker than 1-1/2”. The screen assembly may be positioned 1/2” to 1-1/2” from the front of the fireplace to allow facing to tuck under the screen assembly. Facing thicker than 1-1/2” may also be used, however the screen assembly will be recessed into the facing rather than overlapping facing. Thick Facing Template (98500699) A thick facing template is available from Travis Industries. It attaches to the fireplace (along with 2x4s) and provides a template for thick (1-1/2” or greater) facing . See the kit instructions for details. NOTE: Pay close attention to the following thick facing requirements when planning installation of facing material over 1-1/2” thick. If facing greater than 1-1/2” is used, make sure to leave a 3/8" gap above the screen assembly and 1/8” to the sides and below. This gap is required to allow for the screen assembly to be removed. Above Tile Stop Sides of Tile Stop Below Tile Stop MINIMUM GAP This provides 3/8” (9.6mm) gap above screen assembly, 1/8” (3.2mm) gap to the sides and below. 3/4” (19mm) 5/8” (16mm) 3/8” (9.5mm) UNIFORM GAP This provides 3/8” (9.6mm) gap around all sides of the screen assembly. 3/4" (19mm) 7/8” (22.5mm) 5/8” (16mm) 2x4 Framing This area above, below, and to the sides of the tile-stops must be left open when using facing over 1-1/2" thick. 5-1/4" 134mm 06/24/2019 42 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Screen Assembly Mounts The screen assembly mounts (located on outer front edges of the fireplace) are adjustable to allow the screen assembly to be positioned 1/2" (12mm) to 1-/12” (38mm) from the front of the fireplace. This allows facing to tuck under the screen assembly. Each mount is held in place by (3) Philips head screws. Before mounting the screen assembly, adjust the mounts so that the front edge is flush with the finish material surrounding the fireplace. To adjust the mounts, loosen the screws, slide the mounts to the desired position, then tighten the screws. Thin Facing (1/2" 13mm) - Top View Max. 1/2" (13mm) Overlap Drywall Fireplace Framing Screen Assembly Mount Thick Facing (1" 26mm) - Top View Max. 1/2" (13mm) Overlap Drywall Fireplace Framing Screen Assembly Mount Phillips Screwdriver Screen assembly mount may be slid forward to accommodate facing. Position edge of mount flush with finish material 06/24/2019 Installation (for qualified installers only) 43 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Do Not Drill or Screw Zone When using screws to secure tile-board or other non-combustible to the front of the fireplace, make sure to avoid the area on the front of the fireplace that is painted with the “DO NOT DRILL” shading. Make sure screws penetrate no more than ½” (13mm) into the fireplace. Do not drill or screw in the marked area 06/24/2019 44 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Mantel Requirements  Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured from the non-combustible facing) must fall within the shaded portion of the table.  Any material above the fireplace that protrudes more than 3/4” (19mm) from the non-combustible facing is considered a mantel and must meet the mantel requirements. Mantel Column Clearances  Combustible mantel columns (legs) require a 0” (0mm) clearance to the side of the fireplace (they must be to the side of the fireplace).  Non-combustible mantel columns do not have a minimum clearance. Maximum Mantel Depth (b) Mantel Height Above Base (a) 46" (1169mm)0" (0mm)1" (25mm)2" (51mm)8" (203mm)7" (178mm)6" (152mm)5" (127mm)4" (102mm)3" (76mm)9" (229mm)10" (254mm)11" (279mm)12" (305mm)45" (1143mm) 44" (1118mm) 43" (1093mm) 42" (1067mm) 41" (1042mm) 40" (1016mm) 47" (1194mm) 39" (991mm) 37" (941mm) 38" (966mm) a b 36" (916mm) 35" (890mm) 06/24/2019 Installation (for qualified installers only) 45 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Use of a Non-Combustible Mantel Below Listed Mantel Clearances Each gas fireplace has a unique set of mantel requirements. If you wish to place a non-combustible mantel at a lesser height than specified in this manual, it will need to meet the following requirements:  The header (the framing member above the fireplace opening) must be non-combustible.  The facing must be non-combustible and extend to the header (or mantel, whichever is greater). The facing must also span the entire width of the mantel.  See the illustration below for additional requirements. Gas FireplaceNon Combustible Framing (metal studs) must extend the full width of the mantel and mantel legs. Non Combustible Facing (tile, marble, cement board, etc.) must extend the full width of the mantel. Non Combustible Mantel and Legs TOP VIEW Facing from the Header Up may be combustible (drywall) or non-combustible. Non-Combustible Facing and Non-Combustible Backing Material (tile, marble, cement board, etc.) must extend to the header (or top of mantel - whichever is higher) Non-Combustible Mantel and Mantel Legs (no maximum depth) - No combustible materials allowed behind the mantel. Non-Combustible Framing (metal studs) must be used for the header. Fireplace Face Combustible Framing (wood studs) may be used for the framing behind the fireplace. Gas Fireplace SIDE VIEW Minimum Mantel Height The minimum mantel height is determined by the face and face attachment method (no minimum). The mantel must be properly secured to the framing or use other suitable method. 06/24/2019 46 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Finalizing the Installation 1. Remove the glass (see page 50). NOTE: If using propane (LP) convert the appliance prior to installing the media. 2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up. GSB2 Versions Only Install the batteries into the battery holder 3. Turn on gas to the heater. Leak test all gas joints prior to starting the appliance. Start the pilot to verify gas supply (see instructions on page 48). Leak test all the gas joints. Turn the gas control knob to “OFF” to shut off the appliance. MV Units Only - Pilot Flame Inspection - (see instructions on page 49) The pilot flame should look like the illustration below. Adjust the pilot flame if necessary. GSB2 Units Only - Pilot Flame Inspection - (see instructions on page 49) The pilot flame should look like the illustration below. Adjust the pilot flame if necessary. The pilot flame should look like the illustration below. Adjust the pilot flame if necessary. To adjust the pilot flame, turn this screw. Clockwise lowers the flame while counter-clockwise raises it The pilot flame should touch the top 3/8” of th sensing electrode and make contact with the p hood. Adjust the pilot up or down as necessa 4. Replace the glass. 5. Start the main burner and verify the burner ignites correctly. 6. Leak test all gas joints. Standard Screwdriver Thermopile Pilot Hood 3/8” 9mmThermocouple The pilot flame should touch only the top 3/8” (9mm) of the thermopile. Adjust the pilot up or down as necessary.To adjust the pilot flame, turn this screw (NOTE: if totally unscrewed gas will come out of this port). Clockwise lowers the flame while counter-clockwise raises it. Pilot Hood Spark Electrode Sensing electrode 06/24/2019 Installation (for qualified installers only) 47 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Air Shutter Adjustment Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame. Air Shutter Adjustment 7. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for a remedy. 8. Give this manual to the home owner for future reference and fully explain operation of this heater. For comprehensive operating and maintenance instructions, refer to the Owner's Manual. ACID WASH WARNING: Make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. Burner Air Shutter Control Right = More Air Left = Less Air NOTE: Use a screwdriver or pliers to adjust the air shutter (it will be hot). Typically, the air shutter is more closed (right) on NG, more open (left) on LP. Correct Flames should be blue at the base, yellow-orange on the top.If the flames are too tall or sooty on the ends, open the air shutter. Not Enough Air If the flames are all blue and short, close the air shutter. Too Much Air 06/24/2019 48 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Location of Controls There is a door on the lower portion of the screen assembly to provide access to the manual controls on the fireplace. The door is held closed by two magnets. Open the door by gently pulling outward on the upper portion of the lower trim. GSB2 Version MV Version On/Off Switch Flame Adjust Knob Optional Blower Dial Shutoff Valve (accessible with screen removed) Rotate the Control Door Down to Access Controls Battery Tray - or - Optional Remote Receiver Continuous / Intermittent Pilot Switch Optional Light Dial Pilot Igniter On/Off Switch Optional Blower Dial Shutoff Valve (accessible with screen removed) Rotate the Control Door Down to Access Controls Optional Remote Receiver Gas Control Knob Flame Adjust Knob Optional Light Dial 06/24/2019 Installation (for qualified installers only) 49 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install MV Units Only - Starting the Pilot The pilot flame ignites the main burners. Without it, the heater will not turn on. The pilot will need to be lit if the gas supply was interrupted or if the heater encounters adverse conditions. This is a safety feature. If the pilot turns off frequently, call your dealer for information. We recommend you leave the pilot lit during the heating season. You may wish to turn it off during the warmer months to conserve fuel (turn the gas control valve to “OFF”). To start the pilot follow the directions below: BARRIER SCREEN The barrier screen must be secured in place when starting the pilot with the glass on. WARNING: If the pilot does not light after 15 seconds (see instructions below) remove the screen and glass assemblies before attempting to light the pilot a second time. This allows you to smell for gas inside the sealed firebox to prevent gas buildup. If pilot does not light after second attempt, contact your dealer for service. HINT: You may wish to remove any logs (or glass, pilot shield, etc.) that obstruct your view of the pilot NOTE: Set ON/OFF switch to “OFF”, or set the thermostat to lowest setting (if applicable). a Push gas control knob in slightly and turn clockwise to "OFF" position. NOTE: Gas control knob will not turn unless it is pressed in slightly. DO NOT FORCE. Wait five minutes to let any gas that may have accumulated inside the firebox escape. If you smell leaking gas, follow the directions on the cover "IF YOU SMELL GAS". b Locate pilot in the firebox along the top surface of the burner. Push gas control knob in slightly and turn counterclockwise to “PILOT” position. - Press gas control knob in and hold. - Immediately press igniter button repeatedly until pilot is lit. WARNING: If pilot does not light after 15 seconds, release knob then follow the instructions above under “BARRIER SCREEN”. c Keep the gas control knob depressed for 30 seconds once the pilot is lit. d Release the gas control knob. If the pilot goes out, repeat steps B and C. If the pilot refuses to stay lit after several tries, turn gas control knob to “OFF” and call your dealer for service. With the pilot lit, proceed to step “e”. NOTE: If knob does not pop up when released, stop, turn off the gas at the shutoff and immediately call your dealer for service. NOTE: If you removed any media or shield, replace in the original location. Replace the glass if removed earlier. e Turn the gas control knob counter-clockwise to "ON". With the pilot lit, the heater can be operated using the normal controls. Make sure to return the heater to the correct configuration before proceeding (replace logs, glass, barrier screen, if applicable). a b c d e 06/24/2019 50 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Glass Frame Removal and Installation A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. The appliance must be completely cool before removing the glass. Do not strike or slam the glass. Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. 1. Remove the screen-trim assembly by lifting the assembly up slightly and tilting it toward you. The mounting hooks on the back of the assembly will disengage the fireplace. Set the assembly aside for reinstallation. NOTE: Opening the access door on the front of the assembly allows for a easy location to get a secure grip on the assembly for removal Replacement Barrier Part # 42 ProBuilder 250-04494 54 ProBuilder 270-01993 Top Corner Bottom Corner Bottom hook engages this slot in bracket Top hook engages this slot in bracket 06/24/2019 Installation (for qualified installers only) 51 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 2. Remove the glass frame following the directions below. Replacement Glass Frame Part # 42 ProBuilder 250-04491 54 ProBuilder 270-01994 Open the four latches holding the glass frame in place (start with the bottom) - follow the directions shown to the right.a Lift the glass frame up and pull it forward to remove.b Re-Attaching the Glass Frame: a) Hang the glass frame on the firebox. b) While holding in place, attach the upper latches (follow the instructions to the right in reverse). c) Lift the glass frame slightly and attach the lower latches. NOTE: Make sure the glass frame is all the way in place - it should be parallel with the front of the fireplace when installed. NOTE: You may need to lift the glass frame while re-attaching. Glass Top of Firebox Latch Catch (on glass frame) Pliers may be used NOTE: Make sure the glass frame is all the way in place – It should be parallel with the front of the fireplace when installed. 06/24/2019 52 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install The latch can come loose from glass frame anchor. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the latch if it becomes loose. Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame anchor. NOTE: this slot may be at a different angle than illustrated. Note how the washer on the latch fits behind the flange on the glass frame anchor. Glass Frame Anchor Once fully inserted, turn the latch until it is upright. Latch 06/24/2019 Installation (for qualified installers only) 53 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Barrier Screen Visual Deflector Adjustment The barrier screen assembly has an adjustable visual deflector along the lower edge. If the assembly is adjusted to accommodate thick facing material, adjust the deflector, as shown below, to block the view of the valve area. 1. Place the screen assembly face down on a soft surface to protect it from scratching. Locate the nuts along the bottom edge of the deflector (in this example there are 3, your fireplace may have more). 2. Remove the nuts using an 11/32” nut driver. Move the deflector to the desired position and reinstall the kept nuts. Test fit the assembly to the fireplace and make any adjustments as needed. 06/24/2019 54 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Crushed Glass Installation Do not allow the crushed glass to block the air slots or to become too thick (maximum 1 layer deep on the burner). Failure to properly install glass may lead to sooting and improper burning. If converting to LP (propane), convert the appliance prior to placing the crushed glass. Install the crushed glass on the glass tray following the directions below. Quantity of Crushed Glass 42 ProBuilder 5 lbs. (2.3 Kg) 54 ProBuilder 6 lbs. (2.7 Kg) 1 Remove the setup pilot cover and the cover plate from the unit to access the pilot assembly underneath. Remove the silicone sleeve that is shipped on the spark electrode. Re-install the cover plate and setup pilot cover Make sure that the setup pilot cover is installed over the pilot assembly before adding glass 2 Spread an even layer of crushed glass over the media tray and burner. The glass must be only 1 layer thick on the burner but can be 2 layers thick on the media tray. Make sure no glass is in the pilot area indicated in the picture below. No glass in this area. 06/24/2019 Installation (for qualified installers only) 55 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 3 Make sure the rear and end air channels are free of crushed glass. Use a screwdriver to clear this area. Make sure the glass is only 1 layer deep on the burner. 4 Remove the pilot shield to uncover the pilot once you are finished placing the glass. Only one layer thick on burner 06/24/2019 56 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install LP Conversion Instructions WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. The parts required to convert this appliance to us LP gas are included in the stove pack that was shipped with the appliance. The conversion kit contains the LP manual regulator and torx wrench, burner orifice, and pilot orifice. 1. Access the firebox. 2. Remove the burner skirt by lifting the front edge up and sliding the skirt forward. 06/24/2019 Installation (for qualified installers only) 57 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 3. Remove the burner. It is held in place with 8 screws (1/4” nutdriver). 4. Remove the air shutter retainer as shown below. It is held in place with 2 screws (1/4” nutdriver). 06/24/2019 58 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 5. Follow the directions below to replace the orifice. 6. Reinstall the orifice gasket that was removed in step 6. 1/2" Wrench Use a 9/16" wrench to secure the manifold while removing the orifice with a 1/2" wrench. Screw the LP orifice until orifice protrudes 15/16" (23.8mm) indicating full insertion (use wrench to secure manifold when re-attaching orifice). d Look here for the orifice identification Apply thread sealant to the LP orifice prior to installation. Use the chart below to identify the correct orifices. c Remove the manifold gasket (note orientation - the larger side goes downwards). REPLACE THE GASKET AFTER INSTALLING LP ORIFICE. Rear Orifice 15/16" 23.8mm a b9/16" Wrench PB 42 Lin. 1.45mm #42 PB 54 Lin. 1.65mm #36 LP NG The longer portion of the gasket should be at the bottom. 06/24/2019 Installation (for qualified installers only) 59 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 7. Install the LP pilot orifice following the instructions below. (a) Use a 7/16” open-end wrench to remove the pilot hood. (b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace the pilot hood, tightening the pilot hood until it is snug (do not over-tighten). MV Version GSB2 Version a bNatural Gas Orifice = .020N LP (Propane) Orifce = .014LP .020N or .018N .014LP 7/16" Wrench a b 7/16" Wrench Natural Gas Orifice = .020N LP (Propane) Orifce = .014LP .020Nor.018N .014LP 06/24/2019 60 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 8. Remove the regulator from the front of the gas control valve. There is an knob extension on the regulator knob that will need to be moved to the new regulator. To remove the extension pull toward you. Replace with the propane regulator, using the new gasket and screws included with the regulator. Re-install the knob extension onto the LP regulator knob. The knob extension is directional so you may need to turn it until it lines up properly with the regulator knob and can be pushed into place.. NOTE: Leak test this area after the heater is installed, gas is connected, and the main burner is lit. MV Version GSB2 Version Replace the regulator following the instructions included with the regulator kit. Remove and discard the screws (see “a” below) holding the stock regulator in place (see “b” below). Remove the stock regulator and gasket (see “c” below). Place the LP regulator in place, making sure the pre-fitted gasket (see”c” below) is in place – make sure it is correctly oriented. Secure using the screws included with the motor – tighten to 25 Lb-inches. Leak test this area after installation to verify proper installation. There is a label on the base of the regulator knob indicating regulator type (NG or LP). Place the included label on the valve body where it can be easily seen to insure proper identification (“d”). Place the LP label on the base near the gas control valve. d Remove and discard the three screws using a slotted screwdriver of Torx T-20. NOTE: Make sure the regulator gasket is correctly aligned before installation. Remove and discard the regulator, diaphram, spring and center post. a bSlotted Screwdriver (or T-20 Torx) Install the LP regulator. Use the screws included with the LP regulator. Tighten to approximately 25 Lbs. torque. c Slotted Screwdriver (or T-20 Torx) a T-20 Torx or Slotted Screwdriver b c d 06/24/2019 Installation (for qualified installers only) 61 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Wall Mount Remote Thermostat installation (optional) Packing List  GS Wall Remote  Receiver Assembly  Switch Blank  (4) AA Batteries  (3) AAA Batteries Installation If Using the Optional Blower, Install it First The optional blower should be installed before installing the remote. 1 Remove the lower front access panel from the fireplace by reaching in behind it and loosening the two wing nuts and (1) ¼” screw on each side of the panel that hold it in place (see fireplace manual for details.) Lift up and then out on the panel to remove. Lay the panel face down in front of the fireplace. 2 Remove the 4 screws that secure the dashboard to the fireplace and gently lower it to gain access to the back side. NOTE There should be enough slack in the attached wires to lower the dashboard to the floor. Make sure not to damage any off the attached wires. 3 Remove the two wires from the back of the on/off switch. 06/24/2019 62 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 4 Remove the switch from the dashboard by depressing the tabs on the top and the bottom of the switch housing while pressing the back of the switch forward through the hole in the dashboard. Replace the switch with the included switch blank (see pictures below). 5 On the back side of the panel you removed there be a bracket with two wing nuts. Remove the wing nuts and set aside for reinstallation. 6 Align the two holes on the bottom of the receiver assembly with the studs and secure the assembly to the bracket using the two wing nuts removed in the previous step. 06/24/2019 Installation (for qualified installers only) 63 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install 7 Connect the on/off switch wires (disconnected earlier) to the connectors on the back of the receiver. -- For GSB2 appliances make sure to attach white wire to white wire, green wire to green wire. -- For MV appliances, wire orientation does not matter. 8 Replace the dashboard. 9 Verify wires are not touching the bottom of the firebox. Adjust if necessary. 10 Install 4AA batteries into the receiver. 11 Install 3AAA batteries into the remote. 12 Sync the remote with the receiver (see syncing instructions included with remote). 13 Return the appliance to the correct configuration. 06/24/2019 64 Installation (for qualified installers only) © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Wiring Diagram – MV Version Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Optional Blower Wiring Orange White Piezo IgniterThermopile Red Thermocouple Copper Co-Axial Wire Red Spark Electrode Pilot Hood On/Off Switch (on fireplace) Optional Wall Switch, Thermostat, or Remote Control Brown 06/24/2019 Installation (for qualified installers only) 65 © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Wiring Diagram – GSB2 Version Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Pilot Sensor Appliance Ground GreenOrangeYellow / GreenWhiteBlueIPI/CPI Switch 120 VAC Power In BlackRedYellowBlackWhiteGreenBase Integrated Fireplace Control (IFC) 3.15A FUSE RedWhite GreenBlack ON / OFF Main Burner Switch Optional Blower(s) ThermodiskRheostat Spark Rod Appliance Ground Flame Detect AA Battery Tray 06/24/2019 66 Index © Travis Industries 1/2/19 - 1453 PB 42 & 54 MV/GSB2 Install Additional Items Required .................................. 7 Air Shutter Adjustment ..................................... 47 Altitude Considerations .................................... 26 Approved Vent ................................................. 2 6 Approved Vent Configurations ......................... 27 Barrier Screen Visual Deflector Adjustment ..... 53 Class A Chimney Conversion .......................... 36 Clearances ......................................................... 9 Corner Installations .......................................... 1 9 Crushed Glass Installation ............................... 54 Diffuser ............................................................. 28 Dimensions ........................................................ 6 Electrical Connection ....................................... 24 Fireplace Placement Requirements ................... 9 Fuel .................................................................. 22 Gas Line Connection ........................................ 22 Gas Line Location ............................................ 23 Gas Line Requirements ................................... 22 Glass Frame Removal and Installation ............ 50 Hearth Requirements ....................................... 38 Heating Specifications ........................................ 6 Installation Options ............................................. 6 Listing Details ..................................................... 2 Location of Controls ......................................... 48 LP Conversion Instructions .............................. 56 Mantel Column Clearances .............................. 44 Mantel Requirements ....................................... 44 Masonry Chimney Conversions ....................... 35 Massachusetts Approval .................................... 2 Massachusetts Requirements ........................... 8 Minimum Framing Dimensions ........................ 11 Overview ............................................................ 2 Packing List ........................................................ 7 Raised Fireplaces .............................................. 9 Recommended Installation Procedure .............. 7 Restrictor Position ............................................ 27 Safety Warnings ................................................. 4 Standoff Assembly ........................................... 12 Starting the Pilot ............................................... 49 Steps for Finalizing the Installation .................. 46 Termination Requirements .............................. 37 Vent Clearances .............................................. 26 Vent Configuration Horizontal Termination with Vertical Rise 31, 34 Vertical Termination ................................. 30, 33 Vent Configurations for 42 PB ......................... 29 Vent Configurations for 54 PB ......................... 32 Vent Firestop .................................................... 26 Vent Installation ............................................... 27 Vent Requirements .......................................... 26 Wiring Diagram .......................................... 64, 65 06/24/2019