Loading...
HomeMy WebLinkAboutFile Documents.601 E Hyman Ave.0131.2018 (5).ACBKwww.berkomep.com For Technical Services, Call 800-642-4328 ITEM# BFLY_CP_0318-1 IDEAL SPACES § Offices § Hallways § Lobbies § Conference Rooms § Retail Spaces § Locker Rooms § Laboratories § Yoga Studios § Living Rooms § Bedrooms § Bathrooms § Basements COLORS § Flurry White § Custom Colors and Silkscreens Available CP SERIES RADIANT CEILING PANELS RADIANT HEATERS n Ideal for invisible, primary or supplemental comfort n Perfect for offsetting perimeter heat losses or providing primary heat to an entire space n No moving parts. No maintenance required. n No air movement so no spreading of dust particles n Full line of custom panels available upon request (see specifications on next page) n Unit comes standard with 48 in. of 1/2 in. flexible metal conduit and J-Box connector n Galvanized or aluminized steel housing n Encapsulated casted element assures uniform temperatures across surface and unit longevity n Includes ground wire and 48 in. lead wires housed in flexible metal conduit n All panels come standard with combination Earthquake/T-bar grip clips n Hanging Clips provide holes for support chains, or can be folded over T-Bar to reduce lateral movement n Constructed of fire retardant materials; no fire or hazardous rating 1YEARWARRANTY WORKMANSHIP 5 YEARWARRANTY ELEMENT DIMENSIONS § Custom Sizes Available 24” 24” or 48” www.berkomep.com For Technical Services, Call 800-642-4328 ITEM# BFLY_CP_0318-1 CP SERIES RADIANT CEILING PANELS mountingholes sideframe screws end frame Wiring Diagrams:Heaters must be properly grounded 208V & 240Vsupplyline voltagethermostator switch (not included) 120V, 277V & 347Vsupply B B G heater heater GWB extrudedaluminum frame Metal: extruded aluminumdecorative frame:.062" thick, 3"deep Wood: heaters can be framed in wood.Consult your factory representative for specifics. Frame construction for surface mount panels radiantheater sideframe endframe corner Metal: extruded aluminum inverted “T”“T”= .125 thick by 1.432 wide by 1.875 high Frame construction for recessed panels frame ceilingjoist radiantheater T-BAR SYSTEM radiantheatingpanel universalmountingclip ceilingtile T-bar grid ceilingtile REVEALED EDGE CEILING SYSTEMTEGULARFINELINE TEGULAR Tegular ceiling tile universalmounting clips radiant heatingpanel Fineline9/16"grid Tengular9/16"grid MODELS & SPECIFICATIONS / STANDARD CATALOG NO.UPC VOLTS WATTS AMPS SIZE (in.)SHIP WT. (LBS) CP251F 6 85360 01658 0 120 250 2.1 24x24 15 CP258F 6 85360 01663 4 208 250 1.2 24x24 15 CP252F 6 85360 01659 7 240 250 1.0 24x24 15 CP257F 6 85360 01662 7 277 250 0.9 24x24 15 CP253F 6 85360 01660 3 347 250 0.7 24x24 15 CP311F 6 85360 01669 6 120 310 2.6 24x24 15 CP318F 6 85360 01674 0 208 310 1.5 24x24 15 CP312F 6 85360 01670 2 240 310 1.3 24x24 15 CP317F 6 85360 01671 9 277 310 1.1 24x24 15 CP313F 6 85360 01673 3 347 310 0.9 24x24 15 CP371F 6 85360 01675 7 120 375 3.1 24x24 15 CP378F 6 85360 01685 6 208 375 1.8 24x24 15 CP372F 6 85360 01676 4 240 375 1.6 24x24 15 CP377F 6 85360 01677 1 277 375 1.4 24x24 15 CP373F 6 85360 01684 9 347 375 1.1 24x24 15 CP501F 6 85360 01691 7 120 500 4.2 24x48 28 CP508F 6 85360 01696 2 208 500 2.4 24x48 28 CP502F 6 85360 01692 4 240 500 2.1 24x48 28 CP507F 6 85360 01695 5 277 500 1.8 24x48 28 CP503F 6 85360 01693 1 347 500 1.4 24x48 28 CP621F 6 85360 01697 9 120 625 5.2 24x48 28 CP628F 6 85360 01707 5 208 625 3.0 24x48 28 CP622F 6 85360 01698 6 240 625 2.6 24x48 28 CP627F 6 85360 01706 8 277 625 2.3 24x48 28 CP623F 6 85360 01699 3 347 625 1.8 24x48 28 CP751F 6 85360 01713 6 120 750 6.3 24x48 28 CP758F 6 85360 01718 1 208 750 3.6 24x48 28 CP752F 6 85360 01714 3 240 750 3.1 24x48 28 CP757F 6 85360 01717 4 277 750 2.7 24x48 28 CP753F 6 85360 01715 0 347 750 2.1 24x48 28 ACCESSORIES / STANDARD CATALOG NO.UPC DESCRIPTION QSF2424 6 85360 20184 3 Surface Mounting Frame for 24” x 24” Panels QSF2448 6 85360 20185 0 Surface Mounting Frame for 24” x 48” Panels QRF2424 6 85360 20186 7 Recess Mounting Frame for 24” x 24” Panels QRF2448 6 85360 20187 4 Recess Mounting Frame for 24” x 48” Panels NOTE: Heating panels do not have a fire or hazardous rating, but construction is of fire retardant materials. Panels normally are treated like light fixtures. If necessary, acoustical tile can be placed on top of the panels. NOTE: When ordering panels with custom features, the catalog number will change. Please see next page for more information on made to order custom products. WALL HEATERS RADIANT HEATERS MODELS & SPECIFICATIONS / MADE TO ORDER WATTS PER PANEL – NOMINAL PANEL LENGTH PANEL WIDTH (IN.)WATT DENSITY 24-35 IN.36-47 IN.48-59 IN.60-71 IN.72-83 IN.84-95 IN.96 IN. 10-13 High 155 235 315 390^––– Med 130 195 260 325^––– Low 105 155 210 260^––– 14-17 High 235 350 470 585^––– Med 195 295 390 490^––– Low 155 235 315 390^––– 18-21 High 315 470 625 780 940^^–– Med 260 390 520 650 780^^–– Low 210 315 415 520 625^^–– 22-28 High 375 565 750 940 1125 1315 1500 Med 310 470 625 785 940 1095 1250 Low 250 375 500 625 750 875 1000 ADDITIONAL FEATURES / MADE TO ORDER TEGULAR (revealed edge): Tegular systems may utilize a standard grid with a 10/16 in. cross-T or a “fine line” grid with a 9/16 in. cross-T. The acoustical title is notched to hang below the grid creating the revealed edge. Tegular panels are built with a support angle on all four sides to allow the panel front to drop flush with the finished ceiling. Tegular and Fine line Tegular panels are supplied standard with universal mounting clips installed for support chain. SILKSCREEN: Radiant heating panels can be silk screened to provide an architectural blend with leading acoustical tiles. For T-bar, concealed spline and Tegular ceiling systems. CUSTOM COLORS: Radiant heating panels can be painted any color desired with high temperature acrylic paints without affecting panel performance. Radiant energy is emitted from heating panels in the 8-10 micron wavelength range. One of the principal characteristics of the wavelength is that it is not color selective as are shorter wavelengths. Consequently, the surface color of the panel is unimportant to heating efficiency and can be considered solely in the light of aesthetics. PANEL FRONTS FOR CONTINUOUS CEILING LINE: To provide a continuous ceiling line around the perimeter of a building, the factory can provide panel fronts to be interspersed between the functioning heating panels. CONTROLS: P/E Switches - factory prewired to heaters. 20 amps - 120V, 240V, 208V and 277V. Power Relay - factory prewired to heaters. 30 amps single-pole with 24V, 120V, 208/240V or 277V holding coil voltages. LONGER FLEXIBLE CONDUIT: Panels will replace the standard 48 in. greenfield with up to 11 ft. of 1/2 in. flexible conduit. STAINLESS STEEL CONSTRUCTION: Special stainless steel panels are available for chlorine storage areas. Panels will be equipped with seal tight connectors and silicone sealed. If orders call for stainless steel construction the panels will be painted unless specified different. Three different finishes available - mill, mirror and brushed. FACTORY SILICONE-SEALED PANELS: Exterior moisture and condensation do not affect heating panel performance, but water inside the unit can cause the panel to fail. Panels being used in locker rooms and swimming pool areas should be totally sealed with silicone at the factory before shipment, if there is a chance of moisture above the ceiling, then seal tight conduit and seal tight connectors also should be used. SEAL-TIGHT FLEXIBLE CONDUIT & CONNECTORS: Radiant ceiling panels come with 1/2 in. greenfield flexible conduit and straight connectors. Seal-tight connectors and conduit can be substituted at the factor if panels are to be used in high moisture areas or if required by local electrical codes. HEAVIER DUTY PANELS: For special installation the factory can use heavier gauge steel in the construction of the panels. MODULAR WIRING SYSTEMS: For specific jobs, the factor can substitute modular connector for the straight connectors and pig tails that are standard equipment. HOW TO ORDER The catalog number for custom panels begins with the BT prefix followed: • Watt Density (H, M, L) • Panel Width • Panel Length • Voltage (1=120V; 8=208V; 2=240V; 7=277V; 3=347V) For example, a 13 x 36 in. 240V unit with a high watt density would be BTH13362. When ordering, please specify panel size as exact or nominal (panels can be up to 7/1 in. less in size). ^ maximum panel length = 60 in. ^^ maximum panel length = 72 in. Catalog No. for surface mounting frames (QSF) and recess mounting frames (QRF) begin with their respective prefix followed by width and length of panel. NOTE: Custom products are made to order and non-returnable. WALL HEATERS www.berkomep.com For Technical Services, Call 800-642-4328 ITEM# BFLY_CP_0318-1 RADIANT HEATERS CP SERIES RADIANT CEILING PANELS ACCESSORIES / STANDARD CUSTOM PANEL OPTIONS DESCRIPTION SILKSCREEN To Provide An Architectural Blend With Leading Ceiling Tile, 2x5 ft. Max. There is a Panel Charge Each Time. If Manufacturer Does Not Have A Tile Pattern Screen There Is An Additional One-Time Charge. See Pricebook. CUSTOM PAINT Solid Color Custom Painted Panel - To Provide An Accent Strip TEGULAR or FINELINE TEGULAR Tegular - Reveal Edge Detail - (For 15/16 in. Grid) Construction Fineline Tegular - Reveal Edge Detail - (For 9/16 in. Grid) EXTRA-LENGTH GREENFIELD FLEX (1/2" x 48" STANDARD)Custom Flexlength 1/2 x 60 in. / 72 / 84 / 96 / 108 / 120 in. SEALTITE CONDUIT Custom Flexlength 1/2 x 60 in. / 72 / 84 / 96 / 108 / 120 in. SILICONE SEAL Seams Sealed For Added Moisture Protection. For Use In Shower Rooms And Above Pool Windows STAINLESS STEEL CONSTRUCTION Stainless Steel - 22-Gauge Front Panel, 24-Gauge Back Panel. Includes 1/2 x 48 in. Sealtite Flex And Silicone Seal HEAVY DUTY CONSTRUCTION 16-Gauge Galvanized Or Aluminized Steel Front Panel 18-Gauge Galvanized Or Aluminized Steel Back Panel FILLER PANELS Finished To Match Standard, Silkscreen Or Custom Painted Panel. Does Not Contain An Element Or Flex Conduit. Standard Construction: Front Only. Tegular / Fineline Tegular: Front And Back Only POWER RELAY 24, 120, 208, 240, 277 VAC NOTE: Custom products are made to order and non-returnable.