Loading...
HomeMy WebLinkAboutFile Documents.600 E Main St.0229.2018 (2).ARBKPHASE ENVIRONMENTAL CONSULTANTS Ambient Asbestos Air Monitoring Services Date: November 15, 2018 Project: Ambient air monitoring inside a residential unit. Client/Site Address: David Wilkins, 600 E. Main Street, Unit 309, Aspen, Colorado Air Monitoring Description Phase Con provided ambient air monitoring services at the project site listed above on November 15, 2018. Air samples were situated inside the unit so as to be representative of the entire space. Air samples were obtained and analyzed following the NIOSH 7400 Method, 'A' Rules for PCM analysis. This method determines airborne fiber content which meets the counting criteria for potential asbestos fibers and may include asbestos fibers as well as any airborne particulate which meets the counting criteria. This is the standard state regulatory method for determining compliance with the Maximum Allowable Asbestos Level (MAAL) in all public access spaces. Comments and Recommendations: PCM analysis of the ambient air samples inside the residential unit revealed airborne fiber levels to be less than the Colorado State Maximum Allowable Asbestos Level (MAAL) and the EPA clearance level of 0.010 fibers per cubic centimeter of air; therefore, the area(s) may be o�occupi�nder nop_7abatement conditions. /.Dos A. Close ,,,�orado State Air Monitoring Specialist #2930 ' v 97,"1-260-33411.,l,'� C,C(lils'�lilc'al""}Yir !cv-'. 5j PHASE CON ENVIRONMENTAL CONSULTANTS PCM LABORATORY ANALYSIS OSHA Reference Method - NIOSH 7400 Client: David Wilkins Sampling Date: 11/15/18 Aspen, Colorado Technician/Analyst: D. Close Project: 600 E. Main Street, #309 CDPHE Technician ID: 2930 Aspen, Colorado Abatement Contractor: Not Applicable Description of Work: Ambient air monitoring inside residential unit. SAMPLE SAMPLE DESCRIPTION ID AIR VOLUME fibers/fields 01 Ambient Air Sample; Living Room Area 1389 L 6.5/100 <0.003 f/cc 02 Ambient Air Sample; North Bedroom Doorway 1389 L 6.5/100 <0.003 F/CCNONE 03 Blank ----- DETECTED 04 Blank ----- NONE DETECTED * Colorado State Maximum Allowable Asbestos Level (MAAL) is 0.010 f/cc of air Technician/Analyst: S' 1jra 'ir !i iilC_ti0ll, (--G 'S i i ! A�r�-�{- i :�w�f}nSLllt21'?ta O1�Vt�$Off10E.CfE t Certificates I \i876 Colorado Department of Public Health and Environment ASBESTOS CERTIFICATION* This eel-tifies that Douglas A. Close Certification No.: 2930 has met the requiremetlts of -25-7-507, C.R.S. and Air Quality Control Commission Regulation No. 8, fart B, and is hereby certified by the state of Colorado in the following discipline: Air Monitoring Specialist* Issued: November 01, 2017 Expires: December 08, 2018 "This certificute is valid only with the possession ufu current Division -approved Irainir{," cour--7-fiJic11tioll in the discipline specified uhrn c' Aut�,orized APCD Representative SEAL