HomeMy WebLinkAboutFile Documents.555 E Durant Ave.0017.2019 (8).ACBKInterior Lighting Compliance Certificate
Project Title:
2015 IECC
Project Type:Alteration
Construction Site:Owner/Agent:Designer/Contractor:
Project Information
Energy Code:
Gorsuch Aspen - Ski and Cafe Expansion
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Retail:Sales Area 780 1.59 1240
2-Common Space Types:Storage >=50 - <=1000 sq.ft. 351 0.63 221
1461Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Retail:Sales Area (780 sq.ft.)
LED 1: AM4: Element Multiples 1x4 Open: Other: 4 1 72 72
LED 3: A4: Element Recessed Downlight - 4": Other: 1 11 32 352
LED 4: A2: Element Recessed Downlight - 2": Other: 1 3 12 37
LED 11: L2-f: Linear Window Lt 4.5 W/ft 6.0': Other: 1 2 27 54
Common Space Types:Storage >=50 - <=1000 sq.ft. (351 sq.ft.)
LED 3: A4: Element Recessed Downlight - 4": Other: 1 22 32 704
1219Total Proposed Watts =
Interior Lighting Compliance Statement
Interior Lighting PASSES
02-19-19
05/08/2019
justinh
COMcheck Software Version 4.1.1.0
ez8",
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
# Plan Review
fi Req.ID
Complies?
Comments/Assumptions
C103.2 :Plans, specifications, and/or
OComplies
Requirement will be met.
[PR4]1 :calculations provide all information
❑Does Not
:with which compliance can be
❑Not Observable
:determined for the interior lighting
land electrical systems and equi pment
ONot Applicable
,and document where exceptions to
:the standard are claimed. Information
1 provided should include interior
1, lighting power calculations, wattage of
bulbs and ballasts, transformers and
'control devices.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) M Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Gorsuch Aspen - Ski and Cafe Expansion Report date: 02/19/19
Data filename: C:\Users\tfrye\Dmpbox (Resort Design)\Resort Design Team Folden24442 Gorsuch - Aspen Page 2 of 5
IhDocs\Gorsuch Aspen - Ski and Cafe Expansion.cck
Section
# Rough -In Electrical Inspection
Complies?
Comments/Assumptions
& RB .ID
C405.2.1 ',Lighting controls installed to uniformly
OComplies
Requirement will be met.
[EL15]r reduce the lighting load by at least
❑Does Not
1,50%.
ONot Observable
ONot Applicable
C405.2.1 (Occupancy sensors installed in
OComplies
Requirement will be met.
[EL181r !required spaces.
❑Does Not
ONot Observable
!
ONot Applicable
C405.2.1, Independent lighting controls installed
OComplies
Requirement will be met.
C405.2.2. per approved lighting plans and all
❑Does Not
3 !, manual controls readily accessible and
ONot Observable
a
[EL23] ',visible to occupants.
ONot Applicable
C405.2.2. !Automatic controls to shut off all
OComplies
Requirement will be met.
1 building lighting installed in all
❑Does Not
[EL22]2 1, buildings.
ONot Observable
ONot Applicable
C405.2.3 Daylight zones provided with
OComplies
Exception: Requirement does not apply.
[EL16]' individual controls that control the
❑Does Not
!, lights independent of general area
lighting.
ONot Observable
ONot Applicable
C405.2.3, I Primary sidelighted areas are
OComplies
Exception: Requirement does not apply.
C405.2.3. equipped with required lighting
❑Does Not
1, controls.
C405.2.3.
❑Not Observable
2
ONot Applicable
[EL201c
C405.2.3, Enclosed spaces with daylight area
OComplies
Exception: Requirement does not apply.
C405.2.3. Funder skylights and rooftop monitors
❑Does Not
1, are equipped with required lighting
C405.2.3. (controls.
phot Observable
3 I
ONot Applicable
[EL21]c
C405.2.4 (Separate lighting control devices for
OComplies
Requirement will be met.
[EL4p specific uses installed per approved
❑Does Not
(lighting plans.
[-]Not Observable
1
❑Not Applicable
C405.2.4 ,Additional interior lighting power
OComplies
Requirement will be met.
[ELSp allowed for special functions per the
❑Does Not
approved lighting plans and is
automatically controlled and
ONot Observable
separated from general lighting.
ONot Applicable
C405.3 Exit signs do not exceed 5 watts per
OComplies
Requirement will be met.
[EL67r face.
❑Does Not
ONot Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) M Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Gorsuch Aspen - Ski and Cafe Expansion Report date: 02/19/19
Data filename: C:\Users\tfrye\Dropbox (Resort Designs\Resort Design Team Folder\24442 Gorsuch - Aspen Page 3 of 5
hDocs\Gorsuch Aspen - Ski and Cafe Expansion.cck
Section
# Final Inspection
Complies?
Comments/Assumptions
& RB .ID
C303.3, Furnished O&M instructions for
❑Complies
Requirement will be met.
C408.2.5.:systems and equipment to the
❑Does Not
2 building owner or designated
[FI17]s ',representative.
phot Observable
ONot Applicable
C405.4.1 Interior installed lamp and fixture
OComplies
See the Interior Lighting fixture schedule for values.
[FI18]' lighting power is consistent with what
❑Does Not
is shown on the approved lighting
❑Not Observable
plans, demonstrating proposed watts
ONot Applicable
:are less than or equal to allowed
watts.
C408.2.5. (Furnished as -built drawings for
OComplies
Requirement will be met.
1 :,electric power systems within 90 days
ODoes Not
[FI16]s !,of system acceptance.
ONot Observable
'',
ONot Applicable
C408.3 Lighting systems have been tested to
OComplies
Requirement will be met.
[FI331' :ensure proper calibration, adjustment,
❑Does Not
programming, and operation.
ONot Observable
ONot Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) M Medium Impact (Tier 2) 13 1 Low Impact (Tier 3)
Project Title: Gorsuch Aspen - Ski and Cafe Expansion Report date: 02/19/19
Data filename: C:\Users\tfrye\Dropbox (Resort Design)\Resort Design Team Folder\24442 Gorsuch - Aspen Page 4 of 5
II\Docs\Gorsuch Aspen - Ski and Cafe Expansion.cck
Project Title: Gorsuch Aspen - Ski and Cafe Expansion Report date: 02/19/19
Data filename: C:\Users\tfrye\Dmpbox (Resort Design)\Resort Design Team Folder\24442 Gorsuch - Aspen Page 5 of 5
II\Docs\Gorsuch Aspen - Ski and Cafe Expansion.cck