HomeMy WebLinkAboutFile Documents.257 Park Ave.0120.2019 (9).ARBK GenFlex TPO Membrane 45 mil (1.14 mm) 60 mil (1.52 mm) 7/2010 Single Ply Solutions for Over a Quarter Century™ Page 1 of 1 PRODUCT DATA SHEET 250 West 96th Street, Suite 150, Indianapolis, IN 46260 800-443-4272 • www.genflex.com DESCRIPTION GenFlex TPO membrane meets or exceeds all of the requirements for ASTM D 6878-03 Thermoplastic Polyolefin membrane. The membrane is reinforced with a 9 x 9, 1000 denier polyester scrim. PHYSICAL PROPERTIES PROPERTY ASTM TEST METHOD MINIMUM TYPICAL VALUES Thickness, min, mil (mm) D 751 39 (1.0) 45 (1.14) 60 (1.52) Thickness over scrim, mil (mm) 45 (1.14) D 6878 Annex A1 12 (0.305) 15 (0.38) 60 (1.52) 21 (0.53) Breaking strength, min, lbf (N) D 751 220 (976) 330 (1500) Elongation at reinforcement break, min, % D 751 15 30 Tearing strength, min, lbf (N) D 751 55 (245) 156 (694) Brittleness point, max, ºF (ºC) D 2137 Method B -40 (-40) -49 (-45) Ozone resistance, no cracks D 1149 Pass Pass Properties after heat aging: (retained values) D 573 Breaking strength, % min. D 751 90 90 Elongation at reinforcement break, % min D 751 90 90 Tearing strength, % min. D 751 60 60 Weight change (mass), max % D 751 ±1 -0.02 Linear dimensional change, max, % D 1204 ±1 -0.01 Water absorption, max, mass % D 471 ±3 +1.2 Factory seam strength, lbf (N) D 751 66 (290) 75 (330) Weather Resistance Visual G 155 Pass Pass Breaking Strength, % min. 90 90 90 Elongation at Reinforcement Break, min, % 90 90 90 Water Vapor Permeance – Perm E 96 n/a 0.0122 Static Puncture Resistance – lb (kg) D 5602 n/a 33 (15) Dynamic Puncture Resistance – J D 5635 20 20 Puncture Resistance – lbf (N) FTM 101C Method 2031 200 (890) 337 (1500) INSTALLATION TPO may be installed as a mechanically attached, a fully adhered, or a ballasted system. Please consult current GenFlex TPO specifications for specific application needs. PREPARATION OF SUBSTRATES Substrates must be clean, dry, smooth, and free of sharp edges, tins, loose or foreign materials, oil, grease, or other materials which may damage the membrane. All rough surfaces which could damage the membrane shall be repaired as specified to offer a smooth substrate. All surface voids greater than 1/4” (6.35 mm) wide shall be properly filled with an acceptable material. PRODUCT DATA AVAILABLE COLORS & SIZES White Grey 4’ x 100’ (1.22 m x 30.48 m) 4’ x 100’ (1.22 m x 30.48 m) 6.16’ x 100’ (1.88 m x 30.48 m) 8’ x 100’ (2.43 m x 30.48 m) 6.16’ x 50’ (1.88 m x 15.25 m) 8’ x 100’ (2.43 m x 30.48 m) Tan 10’ x 100’ (3.05 m x 30.48 m) 4’ x 100’ (1.22 m x 30.48 m) 10’ x 25’ (3.05 m x 7.63 m) 12.33’ x 100’ (3.76 m x 30.48 m) 8’ x 100’ (2.43 m x 30.48 m) LEED INFORMATION Reflectivity, % (ASTM C 1549) White Grey Tan 77 47 65 Emissivity (ASTM C 1371) White Grey Tan 0.87 0.87 0.87 Solar Reflectance Index (ASTM D 1980-01) White Grey Tan Initial Aged (3 yrs) 95 82 53 78 Recycled Content Post Consumer Post Industrial 0% 3% - 5% Manufacturing Location Tuscumbia, AL STORAGE Store in original, unopened packaging and away from sources of punctures and physical damage. Assure that structural decking will support the loads incurred by the material stored on roof top. The deck load limitations should be specified by the project designer. SHELF LIFE Not applicable PRECAUTIONARY DATA To avoid sources of punctures and physical damage, take care when moving, transporting, or handling. Waste products such as petroleum products, greases, animal fats, and oils (mineral and vegetable) should be isolated from the membrane. Refer to Material Safety Data Sheet for additional information. CCMC 13370-R 05/20/2019