Loading...
HomeMy WebLinkAboutFile Documents.302 E Hopkins Ave.0126.2018.ACBK ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 1 Client Job Name White House Tavern Property Address 302 E. Hopkins Aspen, CO 81621 TABLE OF CONTENTS 1.0 - Scope of Work 2.0 - Sampling Requirements 3.0 - Sampling Methodology 4.0 - Laboratory 5.0 - Suspect Materials Sampled 6.0 - Table of Results 7.0 - Description of Sampling Area 8.0 - Conclusion - Lab Report - Certifications Asbestos Samples Analyzed: 4 Positive Asbestos Samples: 0 _____________________________________________ Asbestos Sampling Report Date: 11/29/2018 Date of Inspection: 11/27/2018 Client: HD Construction PO Box 4782 Aspen, CO 81612 Attn: Hugh Marsh Building Inspector: Ellen Johnson CDPHE #23799 Joshua Johnson CDPHE #18401 189 County Rd. 135 Glenwood Springs, CO 81601 josh@elementconsults.com (970)274-3139 12/03/2018 ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 2 1.0- This was an inspection for suspect ACM (Asbestos Containing Material) for a remodel. Element Environmental conducted a visible inspection for visible materials that would be impacted during the remodel. This inspection was limited to the areas found in the Description of the Sampling Area 7.0. Although sampling is destructive in nature, this was a non-invasive inspection. It was of materials that were accessible. If other suspect materials become visible/apparent during demolition or construction activities, work in that area should be halted and more sampling/testing must take place, per Colorado regulations. Any suspect materials that were not tested are to be assumed to contain asbestos. 2.0- A limited bulk sampling of from all suspect materials was conducted in accordance with Colorado State Requirements. The minimum number of samples per homogenous areas are as follows: 2.1- Surfacing Materials- <1,000 sq.ft.- Minimum of 3 samples 1,000 sq.ft.- 5,000sq.ft.- Minimum of 5 samples >5,000 sq.ft. Minimum of 7 samples 2.2- Miscellaneous materials- Minimum of 2 samples 2.3- Thermal Systems Insulation (TSI)- Minimum of 3 samples 3.0- The purpose of the inspection is to identify materials that are homogenous. A homogeneous area is defined as one which shares suspect material, texture, color, location, and/or apparent time of construction. The materials are segregated into separate homogenous areas. The size is determined and then samples are taken. The materials are touched to determine friability. Friable ACM is material that can be crushed or reduced to powder by hand pressure. The samples are taken in a random numerical sequence. 4.0- Ellen Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 23799, performed the inspection. The findings were reviewed by Josh Johnson, a Colorado Department of Public Health & Environment certified building inspector, certification number: 18401. Samples taken were sent to CEI Labs in Cary, North Carolina. The samples were analyzed by PLM (Polarized Light Microscopy) analysis. Per the CDPHE Regulation any sample that is found by a lab to be trace, or <1% asbestos, is considered to be ACM material. This material would still be a regulated material by CDPHE. The sample must have an additional “point count” performed to be considered less than 1% and not be regulated by the CDPHE. The lab’s documents with analyses and findings are found below. 12/03/2018 ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 3 5.0- SUSPECT MATERIALS SAMPLES • Tile Grout • Backer Board 6.0- TABLE OF RESULTS HOMOGENOUS AREA DESCRIPTION OF AREA ACM CATEGORY NUMBER OF SAMPLES APPROXIMATE SQ.FT.* ACM ASSESSMENT CATEGORIES % AND TYPE OF ASBESTOS FOUND (A) Tile Grout Miscellaneous 2 ~200 sq.ft. N/A No Asbestos Detected (B) Tile Backer Board Miscellaneous 2 ~200 sq.ft. N/A No Asbestos Detected Key: ACM Assessment Categories: 1- Damaged or significantly damaged Thermal Systems Insulation (TSI) ACM 2- Damaged friable surfacing ACM 3- Significantly damaged friable Surfacing ACM 4- Damaged or significantly damaged friable Miscellaneous ACM 5- ACM with potential for damage 6- ACM with potential for significant damage 7- Friable ACM with low potential for damage Other- ACM not classified in the above Assessment Categories N/A- Not Applicable * Square footage is estimated and not for bidding purposes 7.0- DESCRIPTION OF SAMPLING AREA • The Tile Grout and Backer Board of the wall in the kitchen to be remodeled 8.0- CONCLUSION No Asbestos was detected in any of the samples. Please feel free to contact us with any questions with our information below. Sincerely, Ellen Johnson 12/03/2018 ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 4 12/03/2018 ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 5 12/03/2018 ELEMENT ENVIRONMENTAL | HDC 112718 Whitehouse 6 12/03/2018