HomeMy WebLinkAboutFile Documents.219 S 3rd St.0189.2019 (5).ARBK13.75" (+/- 2")15.1" (+/- 2")PAN
1.3" LIP
7.75"5.25"
7.9"
5.4"
1/4" TAP PLUG FOR
MANIFOLD PRESSURE
CHECK
RECOMMENDED ENCLOSURE LENGTH = PRODUCT LENGTH + 20"
24" RECOMMENDED ENCLOSURE WIDTH
10"10"
HEARTH PRODUCTS CONTROLS
3050 PLAINFIELD RD.
KETTERING, OH 45432
TOLL FREE: 1-877-433-7001
PHONE: (937) 433-7000
FAX: (937) 433-0704
www.hpcfire.com
ISOMETRIC VIEW
SIDE ELEVATION
FRONT ELEVATION
ELECTRONIC IGNITION
Hearth Products Controls Co
CSA CERTIFIED-OUTDOOR USE ONLY
FOR COMMERCIAL AND RESIDENTIAL USE
AVAILABLE IN:
●120VAC OR 24VAC
● On/Off OR Hi/Low
MATERIAL: 304 STAINLESS STEEL
Hi/Lo MODELS HAVE A 40% REDUCTION IN BTU ON LOW SETTING
EI LINEAR TROUGH - FLAME SENSING WITH ELECTRONIC HOT SURFACE IGNITION
771-048
Notes:
1. FOR USE WITH FIXED PIPING SYSTEMS ONLY.
2. NOT FOR USE WITH SMALL TANKS.
3. ALL ENCLOSURES REQUIRE 4 each 18 SQ/IN VENTS ON OPPOSING SIDES AND ADEQUATE DRAINAGE.
4. GAS SUPPLY
● Natural Gas: Operating Supply Pressure: Minimum: 6.0" W.C.; Maximum: 7.0" W.C.
● LP Gas: Operating Supply Pressure: Minimum: 10.0" W.C.; Maximum: 11.0" W.C.
IMPORTANT: Fuel supply for "Hi/Lo" models - It is necessary to supply your (Hi/Lo) fire feature with 1.5 times the maximum rated BTU.
This will ensure there is enough pressure for your high/low function to work properly.This requirement does not increase the amount of fuel your
appliance will consume during normal operation. (Example: A 200K BTU fire pit should be supplied with 300K BTU fuel capacity.)
IMPORTANT: Ensure any flex line that may be used from the permanent main fuel supply to the product is rated to the stated max btu of the product
and certified to ANSI Z21.75*CSA 6.27.
5. MODIFCATION OF PRODUCT WILL VOID ANY CERTIFICATION AND WARRANTY.
6. FOLLOW ALL MANUFACTURER INSTALLATION INSTRUCTIONS AND LOCAL CODES.
7. ALL DIMENSIONS ARE CONSIDERED TRUE AND REFLECT MANUFACTURER'S SPECIFICATIONS AS OF THE REVISION DATE.
8. DO NOT SCALE DRAWING.
9. THESE DRAWINGS ARE FOR SIZING AND PLANNING PURPOSES. ALL INFORMATION CONTAINED HEREIN WAS CURRENT AT THE
TIME OF DEVELOPMENT. THE MANUFACTURER'S RESPONSIBLE FOR THE ACCURACY OF THE DRAWING.
10. CONTRACTOR'S NOTE: FOR PRODUCT AND COMPANY INFORMATION VISIT www.CADdetails.com/info
REFERENCE NUMBER 771-048.
REVISION DATE 6/3/2016
PART NUMBERS STND
BTU
DIMENSION CHART
PAN BURNER
24SSEI-TRGH 50K 24"23.50"
36SSEI-TRGH 75K 36"35.50"
48SSEI-TRGH 100K 48" 47.50"
60SSEI-TRGH 125K 60" 59.50"
72SSEI-TRGH 150K 72" 71.50"