Loading...
HomeMy WebLinkAboutFile Documents.720 E Durant Ave.0064.2018.ACBK0064-2018-ACBK_BuildingComment1 Subject: PlanCheck Page Label: 1 Author: justinh File Name: COMCHECK.pdf Provide cutsheets on all lighting fixtures showing NRTL listing and maximum fixture wattage. COMCHECK.pdf (3) Subject: PlanCheck Page Label: 1 Author: justinh File Name: COMCHECK.pdf This SF is greater than what I measure the space to be per your plan (I measure the space to be 675 SF of interior space per the scale on the plan), please revise. Subject: PlanCheck Page Label: 1 Author: justinh File Name: COMCHECK.pdf Fill out this portion of the project information Subject: PlanCheck Page Label: A21 General Notes Demo & Tenant Improvements Author: justinh File Name: Plans.pdf Are you proposing any mechanical alterations? If so provide that mechanical plan, otherwise show existing supply and return air on your RCP to demonstrate that all spaces are being provided with adequate ventilation. Plans.pdf (9) Subject: PlanCheck Page Label: A21 General Notes Demo & Tenant Improvements Author: justinh File Name: Plans.pdf Show compliant lighting controls per IECC C405.2. This will require automatic occupant sensor controls or time switch controls (C405.2.1, C405.2.2) as well as manual light reduction controls (C405.2.2.2). Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allow Watts / 1-Retail:Sales Area 800 1.59 Total Allowed Proposed Interior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtur Retail: Sales Area (800 sq.ft.) Track Lighting: Wattage based on 32 feet of track 0 0 Total Prop Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is c building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.3.5.1 and to co applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES Provide cutsheets on all lighting fixtures showing NRTL listing and maximum fixture wattage. COMcheck Software Version 4.3.5.1 Interior Lighting Compliance Certificat Project Title: 2015 IECC Project Type:Alteration Construction Site: 720 E DurantAspen, Colorado 81611 Owner/Agent:Designer/Contractor: Project Information Energy Code: Green Joint Allowed Interior Lighting Power A Area Category B Floor Area(ft2) C AllowedWatts / ft2 All 1-Retail:Sales Area 800 1.59 Total Allowed Watts = Proposed Interior Lighting Power D FixtureWatt. AFixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/Fixture C # ofFixture Retail: Sales Area (800 sq.ft.) Track Lighting: Wattage based on 32 feet of track 0 0 0 Total Proposed Watts Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent building plans, specifications, and other calculations submitted with this permit application. The proposed interior lig systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.3.5.1 and to comply with applicable mandatory requirements listed in the Inspection Checklist. Interior Lighting PASSES This SF is greater than what I measure the space to be per your plan (I measure the space to be 675 SF of interior space per the scale on the plan), please revise. OMcheck Software Version 4.3.5.1 nterior Lighting Compliance Certificate 2015 IECC Alteration 611 Owner/Agent:Designer/Contractor: on Green Joint ighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts 800 1.59 1272 1272Total Allowed Watts = Lighting Power E (C X D) D Fixture Watt. A D : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture 00 sq.ft.) Fill out this portion of the project information Leased Square Feet: Location on Property: Occupancy Group: Adjacent tenant Occupancy Groups: Structural systems: Leased Unit Exits: Required Exits: Common Path of Travel: Corridor: Fire Alarm & Detection: Occupancy Load: 704 SF Unit E-3, Southwest side of building M (Merchantile) B (Office) East No structural improvements 1 1 (2105 IEBC 805.3) 41'-0" (75 feet allowed) No A new fire alarm system shall be installed Merchantile (60) 704 SF /12 occupants Accessible:Yes Type of Construction:Type V-B (assumed) Vacant West Classification of Work:Alteration- Level 2 per 2015 IEBC 804.4 and NFPA 72 Fire Sprinkler:No Electrical: Existing installations in Occupancy Group M are not required to be upgraded (2015 IEBC 808.2) All newly installed electrical equipment and wiring shall comply with NFPA 70 Mechanical: Provide mechanical ventilation per International Mechanical Code All newly introduced devices, equipment, or operations that produce airborne particulate matter, odors, fumes, vapor in such quantities as to cause discomfort to occupants shall be provided with local exhaust. y y ected rial may er , and own free of mbered ately all her y other d ith pletion, and rical d any her site to Are you proposing any mechanical alterations? If so provide that mechanical plan, otherwise show existing supply and return air on your RCP to demonstrate that all spaces are being provided with adequate ventilation. 1'-412" 05-14-18 Show compliant lighting controls per IECC C405.2. This will require automatic occupant sensor controls or time switch controls (C405.2.1, C405.2.2) as well as manual light reduction controls (C405.2.2.2). Subject: PlanCheck Page Label: A21 General Notes Demo & Tenant Improvements Author: justinh File Name: Plans.pdf Your POS stations and ID check are required to be accessible. Provide details/interior elevations that show your POS stations meet the requirements of 2009 ANSI A117.1 section 904. Subject: PlanCheck Page Label: A21 General Notes Demo & Tenant Improvements Author: justinh File Name: Plans.pdf This is a type VA building. Revise this note. Subject: PlanCheck Page Label: A21 General Notes Demo & Tenant Improvements Author: justinh File Name: Plans.pdf Provide a plan showing an accessible route to an accessible restroom on site. Provide photos documenting that the existing restroom is accessible. Subject: PlanCheck Page Label: A22 Reflected Ceiling Plan & Wall Types Author: justinh File Name: Plans.pdf These light fixtures are not included in the ComCheck, the ComCheck shall include all lighting within the space. Revise the ComCheck to account for all lighting. Subject: PlanCheck Page Label: A22 Reflected Ceiling Plan & Wall Types Author: justinh File Name: Plans.pdf This is a residential code provision, please remove it from your plan. 6"Gree Ten Your POS stations and ID check are required to be accessible. Provide details/interior elevations that show your POS stations meet the requirements of 2009 ANSI A117.1 section 904. ity , E-3 ncy Groups: 704 SF Unit E-3, Southwest side of building M (Merchantile) B (Office) East Type V-B (assumed) NTS: Vacant West ng Code (as adopted) ng Building Code (as adopted) Alteration- Level 2 nformation: This is a type VAbuilding. Revise thisnote. 6"Green Joi Tenant Imp Provide a plan showing an accessible route to an accessible restroom on site. Provide photos documenting that the existing restroom is accessible. 7'-012"9'-558"10'-0"4"#3-05OFFICE #3-06SAFE ROOM9'-734"9'-734"10'-112"5'-834"5'-712"6'-134" LIGHTING LEGEND Recessed mount Wall mounted #3-05OFFICEMGR both sides w 8" o.c.ners o ceiling oam ped seams ped seams These light fixtures are not included in theComCheck, theComCheck shall include all lightingwithin the space. Revise the ComCheck to account for alllighting. This is a residential code provision, please remove it from your plan. Subject: PlanCheck Page Label: A22 Reflected Ceiling Plan & Wall Types Author: justinh File Name: Plans.pdf Are you proposing any of this type of fixture? If not please remove them from your legend. Subject: PlanCheck Page Label: A22 Reflected Ceiling Plan & Wall Types Author: justinh File Name: Plans.pdf UL U419 is an assembly that uses steel studs which is not what is shown in your detail. Your detail much match a listed/tested assembly to be considered a compliant 1 hour assembly. Please provide a different listing that matches your detail. LIGHTING LEGEND Recessed mount Wall mounted 2 x 4 LED fixture 2 x 2 LED fixture Track light LED plateoor with h sides b d nail @ 48" o.c.ds and corners on ornsulating foambarrier, taped seams h sides 4 ard ansition esh on plywood wall studs wall studs rlap seams Are you proposing any of this type of fixture? If not please remove them from your legend. LIGHTING LE Recesse Wall mou 2 x 4 LED 2 x 2 LED de 5/8" type X gypsum board, both sides 2 x 4 stud wall @ 16" o.c. full cavity wi4x attach 2x4 sill plateto existing subfloor with wall type as described below rubber base, both sides existing floor slab powder actuated nail @ 48" o.c.and 12" from ends and corners 5/8" type X gypsum board to ceiling Leased UnitNeighboring Unitacoustic insulation orexpanded rigid insulating foam 6 mil poly vapor barrier, taped seams 6 mil poly vapor barrier, taped seams fire caulking, both sides existing wall 2 x 4 existing ceiling t & g board metal angle trimat wall/ ceiling transition UL U419 is an assembly that uses steel studs which is not what is shown in your detail. Your detail much match a listed/tested assembly to be considered a compliant 1 hour assembly. Please provide a different listing that matches your detail.