HomeMy WebLinkAboutFile Documents.720 E Durant Ave.0064.2018 (3).ACBK07/12/2018 justinh RENEWAIRE.COM 1.800.627.4499 10 SPECIFICATIONS & DIMENSIONS Specifications may be subject to change without notice. INDOOR UNIT SPECIFICATIONS Ventilation Type: Static plate, heat and humidity transfer Typical Airflow Range: 100-200 CFM Standard Features: Painted cabinet Line-cord power supply Low-voltage circuit for controls Unit may be mounted in any orientation Controls: Onboard 24 VAC transformer/relay package with switched dry contacts Filters: Total qty. 2, MERV 8, spun-polyester media: 10 1/2" x 21 3/4" x 1" Unit Dimensions & Weight: 33 1/2" L x 24" W x 20" H 68 lbs. Max. Shipping Dimensions & Weight (on pallet): 34" L x 44" W x 34" H 110 lbs. Motor(s): Qty. 1, Double-shaft standard motor Accessories: Backdraft damper 8" Wall cap 8" - taupe plastic, galvanized, paintable galvanneal Louver with 8" round duct connection - 12" (W) x 8" (H) Percentage timer control (PTL) Push-button point-of-use controls (PBL), PTL req'd. Percentage timer control with furnace interlock (FM) Electric duct heater - EK series (1–60 kW), for commercial use only 6"Typ. 8 1/8" 9" 5 1/2"Typ.OA EA RA FA 34" Line Cord24" Overall(with HangingBracket)11 7/8"Typ. 28 3/4" Case 33 1/4" Overall 2 1/4" Typ. 6" Nominal Typ. 8" Nominal Typ.18 1/8"Case 2 5/8" 7/8" Typ. 21 3/4" Overall(with Hanging Bracket) 20" Overall 22 1/4" MinimumService Area (Door can be Removed fromHinges.)18 1/2"MinimumSercive Area 23 7/8" Case Door Swing 24V AC Control Terminal LEFT VIEW FRONT VIEW RIGHT VIEW TOP VIEW Model: EV200Drawing Type: Unit DimensionVersion: APR16 ABBREVIATIONSEA: Exhaust Air to outsideOA: Outside Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside INSTALLATION ORIENTATIONUnit may be installed in any orientation. NOTE1.UNLESS OTHERWISE SPECIFIED,DIMENSIONS ARE ROUNDED TO THENEAREST EIGHTH OF AN INCH. 2.SPECIFICATIONS MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. UNIT DIMENSIONS AIRFLOW CONFIGURATION Available as shown in dimension drawing. UNIT MOUNTING & APPLICATION Can be mounted in any orientation. RA/EA airstream can be switched with OA/FA airstream. 200EV Energy Recovery Ventilator Standard Download specification at: renewaire.com/specifications UNIT PERFORMANCE CORE PERFORMANCE Airflow CFM ESP in H20 Temp EFF%Total EFF% Winter/Summer* 122 0.70 81 77/64 149 0.60 79 75/61 168 0.50 78 73/59 176 0.40 78 72/59 186 0.30 77 72/58 192 0.20 77 71/57 207 0.10 76 70/56 * See HVI certification ratings on page 164 of RenewAire’s Full Line Volume XVIII Catalog. ELECTRICAL DATA HP Volts HZ Phase Input Watts FLA 0.1 120 60 Single 157 @ 181 CFM 1.5 Note: Indirect Gas-Fired Duct Furnace is not available on the EV200. 07/12/2018 justinh