Loading...
HomeMy WebLinkAboutFile Documents.720 E Durant Ave.0064.2018 (10).ACBKCOMcheck Software Version 4.3.5.1 V Interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: Permit Date: 20151ECC Green Joint Remodel Alteration 07/06/2018 Construction Site: Owner/Agent Designer/Cordractor: 720 E Durant Unit E Dan Sullvan Clint Hostetter Aspen, Colorado 81611 Aspen Green joint LLC Walker Electric 1030 Grand Ave 1413 Airport Road Glenwood Springs, Colorado 81650 Rifle, Colorado 81650 941-928-4262 970-625-5192 dan@thegreenjoint.com admin@walker-electric.biz Allowed Interior Lighting Power A e C D Area Category Floor Area Allowed Allowed Watts (m) Watts I ft2 1-irIore (RetaitDresaing/Fit6rg Room) 687 0.71 488 Total Allowed Were = 488 Proposed Interior Lighting Power A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ g of Fixture (C X D) Fixture Fixture Watt store (Retail: Dresslno/Fittlno Room. 687 sa.tt.) Track Head: EP840: track limiter 01 Amp: Wattage based on current limiting device capacity, 0 0 0 1 LED: Eaton SKU 65-1084: V Led ship 40W: LED OMer Fixture Unit 6.5W: 1 2 40 80 Track lighting: ET1632: Track Head with 6.SW lamp: Wattage based on 0 feet of hack 0 0 0 270 Total Proposed Wars= 351 Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.3.5.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. CDMYI.�t4D .Sr4-yvS �f$�7'IiJ� O WJ�f7� Project Title: Green joint Remodel Report date: 07/02/18 Data filename: Page let 5 COMcheck Software Version 4.3.5.1 V Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Plan Review I Complies? I Comments/Assumptions C103.2 Plans, specifications, and/or L (Complies [PR41i calculations provide all information []Does Not with which compliance can be []Not Observable determined for the interior lighting []Not Applicable and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 Nigh Impact (Tier 1) 1 2 1 Medium Impact (tier 2) 3 1 Low Impact (Tier 3) Project title: Green Joint Remodel Report date: 07/02/18 Data filename: Page 2of 5 Section # Rough -In Electrical Inspection Compiles? Comments/Assumptions & Re .ID C405.2.1 Lighting controls installed to uniformly OComplies [EI.1511 reduce the lighting load by at least DDoes Not 50%. ONot Observable ONot Applicable C405.2.1 Occupancy sensors installed in OComplies [EL18]1 required spaces. DDoes Not ONot Observable ONot Applicable 0405.2.1, Independent lighting controls Installed ',OComplies C405.2.2. per approved lighting plans and all []Does Not 3manual Controls readily accessible and ONot Observable [EL23]1 visible to occupants. ONot Applicable C405.2.2. Automatic controls to shut off all OComplies 1 building lighting Installed in all []Does Not [EL2212 buildings. []Not Observable []Not Applicable 0405.2.3 Daylight zones provided with []Compiles [EL16]' Individual controls that control the '[]Does Not lights independent of general area []Not Observable lighting. []Not Applicable C405.2.3, Primary sidellghted areas are OComplies C405.2.3. equipped with required lighting []Does Not 1. controls. ONot Observable 0405.2.3. 2 ONot Applicable [EL20]r C405.2.3, Enclosed spaces with daylight area OComplies 0405.2.3. under skylights and rooftop monitors DDoes Not 1, are equipped with required lighting []Not Observable C405.2.3. 3 controls. Applicable ONOtpP [EL -21F 0405.2.4 Separate lighting control devices for DComplies [EL4j1 specific uses Installed per approved []Does Not lighting plans. ONot Observable ONot Applicable C405.2.4 Additional Interior lighting power OComplles [EL811 allowed for special functions per the DDoes Not approved lighting plans and is ONot Observable automatically controlled and []Not Applicable separated from general lighting. C405.3 Exit signs do not exceed 5 watts per OComplles [ELfip face. '[]Does Not []Not Observable ONot Applicable Additional Comments/Assumptions: 1 jHigh Impact (Tier 1) Medium Impact ]?ter 2) 13 1 Law Impact (Tier 3) Project Title: Green joint Remodel Report date: 07/02/18 Data filename: Page 3 of 5 Section # Final Inspection CampllesT Comments/Assumptions 6, It .ID C303.3, Furnished O&M instructions for Otomplies C408.2.5. systems and equipment to the DDoes Not 2 building owner or designated ONot Observable [FI17) s representative. ❑Mot Applicable C405.4.1 Interior installed lamp and fixture OComplles See the lmeriorUghting fixture schedule for values. [FI18j1 lighting power is consistent with what Oboes Not Is shown on the approved lighting ONot Observable plans, demonstrating proposed watts ONot Applicable are less than or equal to allowed watts. C408.2.5. Furnished as-built drawings for OComplies 1 electric power systems within 90 days ❑Does Not [FI1613 of system acceptance. ONot Observable' ONot Applicable C408.3 Lighting systems have been tested to OComplles [FI3311 ensure proper calibration, adjustment, ODoes Not programming, and operation. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 JHIgh Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Green joint Remodel Report date: 07/02118 Data filename: Page 4 of 5 Project T¢le: Green Joint Remodel Report date: 07/02/18 Data filename: Page 5 of 5