HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0043.2019 (11).ACBKCOMcheck Software Version 4.1.0.0
Interior Lighting Compliance Certificate
Project Title:
90.1 (2013) Standard
Project Type:Alteration
Construction Site:
675 E Durant Ave
Aspen, CO 81611
Owner/Agent:
Aspen Skiing Company
Designer/Contractor:
KGM Archiectural Lighting
270 Coral Circle
El Segundo, CA 90245
310-552-2191
Project Information
Energy Code:
The Little Nell - Lobby + Chair 9
Allowed Interior Lighting Power
A
Area Category
B
Floor Area
(ft2)
C
Allowed
Watts / ft2
D
Allowed Watts
(B X C)
1-Reception + Concierge (Hotel:Hotel Lobby)1478 1.06 1567
2-Living Room (Hotel:Hotel Lobby)1283 1.06 1360
3-Chair 9 (Common Space Types:Dining Area - Bar Lounge/Leisure)1576 1.07 1686
4-Corridor (Common Space Types:Corridor/Transition >=8 ft wide)734 0.66 484
5-Stairs (Common Space Types:Stairwell)122 0.69 84
6-Office (Common Space Types:Office - Enclosed)500 1.11 555
7-Restrooms (Common Space Types:Restrooms)348 0.98 341
6078Total Allowed Watts =
Proposed Interior Lighting Power
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
Reception + Concierge ( Hotel:Hotel Lobby 1478 sq.ft.)
LED 1: F4: RECESSED DOWNLIGHT: Other:1 10 13 130
LED 2: F3: RECESSED COMBO DOWNLIGHT: Other:2 6 26 156
LED 3: F6: SURFACE MOUNTED DOWNLIGHT: Other:1 6 12 75
LED 4: F5: RECESSED SMALL DOWNLIGHT: Other:1 4 7 28
LED 5: F14: SURFACE MOUNTED SELF COVE LINEA: Other:1 35 7 234
LED 6: F9: INDIRECT LED TAPE LIGHT: Other:1 30 2 45
LED 7: F8: SURFACE MOUNTED LINEAR UPLIGHT: Other:1 68 3 204
LED 31: F16: SURFACE MOUNTED LINEAR LED STRI: Other:1 4 3 12
LED 34: F19: RECESSED DOWNLIGHT: Other:1 1 18 18
LED 35: F20: SURFACE MOUNTED AMBIENT FIXTURE: Other:1 1 20 20
LED 35: DF6: SCONCE AT RECEPTION: Other:1 2 2 4
LED 36: F21: RECESSED DOWNLIGHT: Other:1 3 12 38
Incandescent 1: DF2: SCONCE AT ENTRANCE: Incandescent 40W:2 2 40 80
Living Room ( Hotel:Hotel Lobby 1283 sq.ft.)
LED 8: F1: SURFACE MOUNTED COMBO DOWNLIGHT: Other:2 10 26 260
LED 9: F2: SURFACE MOUNTED SINGLE DOWNLIGH: Other:1 10 13 130
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
61 ofPage
05/24/2019
justinh
E
(C X D)
D
Fixture
Watt.
A
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast
B
Lamps/
Fixture
C
# of
Fixtures
LED 10: F3: RECESSED COMBO DOWNLIGHT: Other:2 4 26 104
LED 11: F4: RECESSED DOWNLIGHT: Other:1 8 13 104
LED 13: F8: SURFACE MOUNTED LINEAR UPLIGHT: Other:1 83 3 249
LED 14: F10: RECESSED IN-GRADE UPLIGHT: Other:1 27 1 27
LED 15: DF4: SCONCE BY WINDOW: Other:1 2 10 20
LED 32: F10A: RECESSED IN-GRADE UPLIGHT: Other:1 10 1 10
LED 35: DF5: SCONCE AT FIREPLACE: Other:1 4 25 100
Chair 9 ( Common Space Types:Dining Area - Bar Lounge/Leisure 1576 sq.ft.)
LED 18: F12: RECESSED PINHOLE DOWNLIGHT: Other:1 50 13 650
LED 20: F15: SURFACE MOUNTED LINEAR GRAZER: Other:1 31 5 161
LED 21: F16: SURFACE MOUNTED LINEAR LIGHT: Other:1 5 3 15
LED 22: F21: RECESSED DOWNLIGHT: Other:1 2 12 25
LED 23: DF1: SCONCE BY WINODW: Other:2 8 100 800
LED 31: F17: RECESSED STEP LIGHT: Other:1 4 3 10
LED 33: F5A: RECESSED SMALL DOWNLIGHT: Other:1 5 7 35
LED 34: F18: SURFACE MOUNTED LINEAR LED STRI: Other:1 20 3 60
LED 34: DF: CEILING MOUNTED CUSTOM FIXTURE: Other:1 1 240 240
Corridor ( Common Space Types:Corridor/Transition >=8 ft wide 734 sq.ft.)
LED 25: F19: RECESSED DOWNLIGHT: Other:1 13 18 234
LED 27: F7: RECESSED COVE LIGHT: Other:1 81 2 202
LED 35: F17A: RECESSED STEP LIGHT: Other:1 4 3 10
Stairs ( Common Space Types:Stairwell 122 sq.ft.)
LED 30: F19: RECESSED DOWNLIGHT: Other:1 6 12 75
Office ( Common Space Types:Office - Enclosed 500 sq.ft.)
LED 32: F21: RECESSED DOWNLIGHT: Other:1 9 12 112
Restrooms ( Common Space Types:Restrooms 348 sq.ft.)
LED 36: E: EXISTING DOWNLIGHT: Other:1 12 40 480
LED 37: F22: RETROFIT DOWNLIGHT: Other:1 6 14 81
LED 38: F18: LINEAR UNDER COUNTER: Other:1 13 3 39
LED 39: DF3: SCONCE AT MIRROR: Other:1 2 3 6
5285Total Proposed Watts =
Interior Lighting Compliance Statement
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Interior Lighting PASSES
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
62 ofPage
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the
building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting
systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with
any applicable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Anne Friedman | Associate 2019-05-102019-05-23
Inspection Checklist
Requirements: 18.0% were addressed directly in the COMcheck software
COMcheck Software Version 4.1.0.0
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 90.1 (2013) Standard
Section
#
& Req.ID
Plan Review Complies?Comments/Assumptions
4.2.2,
8.4.1.1,
8.4.1.2,
8.7
[PR6]2
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the electrical systems
and equipment and document where
exceptions are claimed. Feeder
connectors sized in accordance with
approved plans and branch circuits
sized for maximum drop of 3%.
Complies
Does Not
Not Observable
Not Applicable
4.2.2,
9.4.3, 9.7
[PR4]1
Plans, specifications, and/or
calculations provide all information
with which compliance can be
determined for the interior lighting
and electrical systems and equipment
and document where exceptions to
the standard are claimed. Information
provided should include interior
lighting power calculations, wattage of
bulbs and ballasts, transformers and
control devices.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
63 ofPage
Section
#
& Req.ID
Rough-In Electrical Inspection Complies?Comments/Assumptions
8.4.2
[EL10]2
At least 50% of all 125 volt 15- and
20-Amp receptacles are controlled by
an automatic control device.
Complies
Does Not
Not Observable
Not Applicable
9.4.1.1
[EL1]2
Automatic control requirements
prescribed in Table 9.6.1, for the
appropriate space type, are installed.
Mandatory lighting controls (labeled
as 'REQ') and optional choice controls
(labeled as 'ADD1' and 'ADD2') are
implemented.
Complies
Does Not
Not Observable
Not Applicable
9.4.1.1
[EL2]2
Independent lighting controls installed
per approved lighting plans and all
manual controls readily accessible and
visible to occupants.
Complies
Does Not
Not Observable
Not Applicable
9.4.1.2
[EL11]2
Parking garage lighting is equipped
with required lighting controls and
daylight transition zone lighting.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
9.4.1.1f
[EL13]1
Daylight areas under skylights and
roof monitors that have more than
150 W combined input power for
general lighting are controlled by
photocontrols.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement does not apply.
9.4.1.3
[EL4]1
Separate lighting control devices for
specific uses installed per approved
lighting plans.
Complies
Does Not
Not Observable
Not Applicable
9.6.2
[EL8]1
Additional interior lighting power
allowed for special functions per the
approved lighting plans and is
automatically controlled and
separated from general lighting.
Complies
Does Not
Not Observable
Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
64 ofPage
Section
#
& Req.ID
Final Inspection Complies?Comments/Assumptions
8.7.1
[FI16]3
Furnished as-built drawings for
electric power systems within 30 days
of system acceptance.
Complies
Does Not
Not Observable
Not Applicable
8.7.2
[FI17]3
Furnished O&M instructions for
systems and equipment to the
building owner or designated
representative.
Complies
Does Not
Not Observable
Not Applicable
9.2.2.3
[FI18]1
Interior installed lamp and fixture
lighting power is consistent with what
is shown on the approved lighting
plans, demonstrating proposed watts
are less than or equal to allowed
watts.
Complies
Does Not
Not Observable
Not Applicable
See the Interior Lighting fixture schedule for values.
Additional Comments/Assumptions:
1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3)
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
65 ofPage
Project Title:
Data filename:
The Little Nell - Lobby + Chair 9
X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN-
LOBBY+C9_CLACULATION.cck
05/23/19Report date:
66 ofPage