HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0043.2019 (11).ACBKCOMcheck Software Version 4.1.0.0 Interior Lighting Compliance Certificate Project Title: 90.1 (2013) Standard Project Type:Alteration Construction Site: 675 E Durant Ave Aspen, CO 81611 Owner/Agent: Aspen Skiing Company Designer/Contractor: KGM Archiectural Lighting 270 Coral Circle El Segundo, CA 90245 310-552-2191 Project Information Energy Code: The Little Nell - Lobby + Chair 9 Allowed Interior Lighting Power A Area Category B Floor Area (ft2) C Allowed Watts / ft2 D Allowed Watts (B X C) 1-Reception + Concierge (Hotel:Hotel Lobby)1478 1.06 1567 2-Living Room (Hotel:Hotel Lobby)1283 1.06 1360 3-Chair 9 (Common Space Types:Dining Area - Bar Lounge/Leisure)1576 1.07 1686 4-Corridor (Common Space Types:Corridor/Transition >=8 ft wide)734 0.66 484 5-Stairs (Common Space Types:Stairwell)122 0.69 84 6-Office (Common Space Types:Office - Enclosed)500 1.11 555 7-Restrooms (Common Space Types:Restrooms)348 0.98 341 6078Total Allowed Watts = Proposed Interior Lighting Power E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures Reception + Concierge ( Hotel:Hotel Lobby 1478 sq.ft.) LED 1: F4: RECESSED DOWNLIGHT: Other:1 10 13 130 LED 2: F3: RECESSED COMBO DOWNLIGHT: Other:2 6 26 156 LED 3: F6: SURFACE MOUNTED DOWNLIGHT: Other:1 6 12 75 LED 4: F5: RECESSED SMALL DOWNLIGHT: Other:1 4 7 28 LED 5: F14: SURFACE MOUNTED SELF COVE LINEA: Other:1 35 7 234 LED 6: F9: INDIRECT LED TAPE LIGHT: Other:1 30 2 45 LED 7: F8: SURFACE MOUNTED LINEAR UPLIGHT: Other:1 68 3 204 LED 31: F16: SURFACE MOUNTED LINEAR LED STRI: Other:1 4 3 12 LED 34: F19: RECESSED DOWNLIGHT: Other:1 1 18 18 LED 35: F20: SURFACE MOUNTED AMBIENT FIXTURE: Other:1 1 20 20 LED 35: DF6: SCONCE AT RECEPTION: Other:1 2 2 4 LED 36: F21: RECESSED DOWNLIGHT: Other:1 3 12 38 Incandescent 1: DF2: SCONCE AT ENTRANCE: Incandescent 40W:2 2 40 80 Living Room ( Hotel:Hotel Lobby 1283 sq.ft.) LED 8: F1: SURFACE MOUNTED COMBO DOWNLIGHT: Other:2 10 26 260 LED 9: F2: SURFACE MOUNTED SINGLE DOWNLIGH: Other:1 10 13 130 Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 61 ofPage 05/24/2019 justinh E (C X D) D Fixture Watt. A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixtures LED 10: F3: RECESSED COMBO DOWNLIGHT: Other:2 4 26 104 LED 11: F4: RECESSED DOWNLIGHT: Other:1 8 13 104 LED 13: F8: SURFACE MOUNTED LINEAR UPLIGHT: Other:1 83 3 249 LED 14: F10: RECESSED IN-GRADE UPLIGHT: Other:1 27 1 27 LED 15: DF4: SCONCE BY WINDOW: Other:1 2 10 20 LED 32: F10A: RECESSED IN-GRADE UPLIGHT: Other:1 10 1 10 LED 35: DF5: SCONCE AT FIREPLACE: Other:1 4 25 100 Chair 9 ( Common Space Types:Dining Area - Bar Lounge/Leisure 1576 sq.ft.) LED 18: F12: RECESSED PINHOLE DOWNLIGHT: Other:1 50 13 650 LED 20: F15: SURFACE MOUNTED LINEAR GRAZER: Other:1 31 5 161 LED 21: F16: SURFACE MOUNTED LINEAR LIGHT: Other:1 5 3 15 LED 22: F21: RECESSED DOWNLIGHT: Other:1 2 12 25 LED 23: DF1: SCONCE BY WINODW: Other:2 8 100 800 LED 31: F17: RECESSED STEP LIGHT: Other:1 4 3 10 LED 33: F5A: RECESSED SMALL DOWNLIGHT: Other:1 5 7 35 LED 34: F18: SURFACE MOUNTED LINEAR LED STRI: Other:1 20 3 60 LED 34: DF: CEILING MOUNTED CUSTOM FIXTURE: Other:1 1 240 240 Corridor ( Common Space Types:Corridor/Transition >=8 ft wide 734 sq.ft.) LED 25: F19: RECESSED DOWNLIGHT: Other:1 13 18 234 LED 27: F7: RECESSED COVE LIGHT: Other:1 81 2 202 LED 35: F17A: RECESSED STEP LIGHT: Other:1 4 3 10 Stairs ( Common Space Types:Stairwell 122 sq.ft.) LED 30: F19: RECESSED DOWNLIGHT: Other:1 6 12 75 Office ( Common Space Types:Office - Enclosed 500 sq.ft.) LED 32: F21: RECESSED DOWNLIGHT: Other:1 9 12 112 Restrooms ( Common Space Types:Restrooms 348 sq.ft.) LED 36: E: EXISTING DOWNLIGHT: Other:1 12 40 480 LED 37: F22: RETROFIT DOWNLIGHT: Other:1 6 14 81 LED 38: F18: LINEAR UNDER COUNTER: Other:1 13 3 39 LED 39: DF3: SCONCE AT MIRROR: Other:1 2 3 6 5285Total Proposed Watts = Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Interior Lighting PASSES Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 62 ofPage Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 90.1 (2013) Standard requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name - Title Signature Date Anne Friedman | Associate 2019-05-102019-05-23 Inspection Checklist Requirements: 18.0% were addressed directly in the COMcheck software COMcheck Software Version 4.1.0.0 Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 90.1 (2013) Standard Section # & Req.ID Plan Review Complies?Comments/Assumptions 4.2.2, 8.4.1.1, 8.4.1.2, 8.7 [PR6]2 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the electrical systems and equipment and document where exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits sized for maximum drop of 3%. Complies Does Not Not Observable Not Applicable 4.2.2, 9.4.3, 9.7 [PR4]1 Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 63 ofPage Section # & Req.ID Rough-In Electrical Inspection Complies?Comments/Assumptions 8.4.2 [EL10]2 At least 50% of all 125 volt 15- and 20-Amp receptacles are controlled by an automatic control device. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL1]2 Automatic control requirements prescribed in Table 9.6.1, for the appropriate space type, are installed. Mandatory lighting controls (labeled as 'REQ') and optional choice controls (labeled as 'ADD1' and 'ADD2') are implemented. Complies Does Not Not Observable Not Applicable 9.4.1.1 [EL2]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and visible to occupants. Complies Does Not Not Observable Not Applicable 9.4.1.2 [EL11]2 Parking garage lighting is equipped with required lighting controls and daylight transition zone lighting. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 9.4.1.1f [EL13]1 Daylight areas under skylights and roof monitors that have more than 150 W combined input power for general lighting are controlled by photocontrols. Complies Does Not Not Observable Not Applicable Exception: Requirement does not apply. 9.4.1.3 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. Complies Does Not Not Observable Not Applicable 9.6.2 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 64 ofPage Section # & Req.ID Final Inspection Complies?Comments/Assumptions 8.7.1 [FI16]3 Furnished as-built drawings for electric power systems within 30 days of system acceptance. Complies Does Not Not Observable Not Applicable 8.7.2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated representative. Complies Does Not Not Observable Not Applicable 9.2.2.3 [FI18]1 Interior installed lamp and fixture lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed watts. Complies Does Not Not Observable Not Applicable See the Interior Lighting fixture schedule for values. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 65 ofPage Project Title: Data filename: The Little Nell - Lobby + Chair 9 X:\TLN - Lobby + C9 refresh - 18361 (JM-AF)\Calculations\Power density\KGM-TLN- LOBBY+C9_CLACULATION.cck 05/23/19Report date: 66 ofPage