Loading...
HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0111.2018 (6).ACBK0111-2018-ACBK_BuildingComments_2 Page: AO.5 SHEET TITLE BUILDING CODE ANALYSIS - EGRESS & OCCUPANCY File Name: 02_Permit Set_Full.AJAX 675 E DURANT_2018-10_2019-02.pdf Subject: PlanCheck Author: nickt Color: Travel path distance must be measured orthagonally (no diagonals). Maximum common path travel distance is 75' for A2 occupancy with sprinkler system. 2015 IBC 1006.2.1. 02_Permit Set_Full.AJAX 675 E DURANT_2018-10_2019-02.pdf (1) Page: 1 File Name: KGM_LIGHTING PLAN.AJAX 675 E DURANT_2018-10_2019-02.pdf Subject: PlanCheck Author: nickt Color: Provide time-switch controls for areas of the building not provided with occupant sensor controls per 2015 IECC C405.2.2. KGM_LIGHTING PLAN.AJAX 675 E DURANT_2018-10_2019-02.pdf (1) K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS SCALE: EGRESS & OCCUPANCY DIAGRAM 1/4" = 1'-0" 1 A0.5 PLANNORTH TRUENORTH BOOTH (50'-2")24" PER OCCUPANT:25 OCCUPANTS DINING (129 SF)15 SF PER OCCUPANT:9 OCCUPANTS BANQUETTE (11'-4")18" PER OCCUPANT:5 OCCUPANTS ASSEMBLY, W/O FIXED SEATING,UNCONCENTRATED ASSEMBLY W/ FIXED SEATING(BOOTH & BANQUETTE SEATING) ASSEMBLY, W/O FIXED SEATING,STANDING SPACE KITCHEN / SERVICE / BAR SERVICE CORRIDORNO OCCUPANCY NOT IN SCOPENOT INSCOPE MAXIMUM EXIT ACCESS TRAVEL DISTANCE = 90'-0" FROM FACE OF WALLS) :3'-8"CLEAR EXITWIDTHTravel path distancemust be measuredorthagonally (nodiagonals). Maximumcommon path traveldistance is 75' for A2occupancy withsprinkler system. 2015IBC 1006.2.1. Provide time-switch controls for areas of the building not provided with occupant sensor controls per 2015 IECC C405.2.2.