HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0111.2018 (6).ACBK0111-2018-ACBK_BuildingComments_2
Page: AO.5 SHEET TITLE BUILDING CODE ANALYSIS -
EGRESS & OCCUPANCY
File Name: 02_Permit Set_Full.AJAX 675 E
DURANT_2018-10_2019-02.pdf
Subject: PlanCheck
Author: nickt
Color:
Travel path distance must be
measured orthagonally (no
diagonals). Maximum common
path travel distance is 75' for A2
occupancy with sprinkler system.
2015 IBC 1006.2.1.
02_Permit Set_Full.AJAX 675 E DURANT_2018-10_2019-02.pdf (1)
Page: 1
File Name: KGM_LIGHTING PLAN.AJAX 675 E
DURANT_2018-10_2019-02.pdf
Subject: PlanCheck
Author: nickt
Color:
Provide time-switch controls for
areas of the building not
provided with occupant sensor
controls per 2015 IECC
C405.2.2.
KGM_LIGHTING PLAN.AJAX 675 E DURANT_2018-10_2019-02.pdf (1)
K-14402-4PURISTFAUCETSBRASS
K-14402-4PURISTFAUCETSBRASS
SCALE:
EGRESS & OCCUPANCY DIAGRAM
1/4" = 1'-0"
1
A0.5 PLANNORTH TRUENORTH
BOOTH (50'-2")24" PER OCCUPANT:25 OCCUPANTS
DINING (129 SF)15 SF PER OCCUPANT:9 OCCUPANTS
BANQUETTE (11'-4")18" PER OCCUPANT:5 OCCUPANTS
ASSEMBLY, W/O FIXED SEATING,UNCONCENTRATED
ASSEMBLY W/ FIXED SEATING(BOOTH & BANQUETTE SEATING)
ASSEMBLY, W/O FIXED SEATING,STANDING SPACE
KITCHEN / SERVICE / BAR SERVICE
CORRIDORNO OCCUPANCY
NOT IN SCOPENOT INSCOPE
MAXIMUM EXIT ACCESS TRAVEL DISTANCE = 90'-0"
FROM FACE OF WALLS)
:3'-8"CLEAR EXITWIDTHTravel path distancemust be measuredorthagonally (nodiagonals). Maximumcommon path traveldistance is 75' for A2occupancy withsprinkler system. 2015IBC 1006.2.1.
Provide time-switch controls for areas of the building not
provided with occupant sensor controls per 2015 IECC
C405.2.2.