Loading...
HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0111.2018 (4).ACBK0111-2018-ARCBK_BuildingComments_1 Page: 3 File Name: 10_COMcheck-Web.AJAX 675 E DURANT_2018-10.PDF Subject: PlanCheck Author: nickt Color: I count 13 DF1 fixtures on the lighting plan. 10_COMcheck-Web.AJAX 675 E DURANT_2018-10.PDF (1) Page: [1] A0.5 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: There are 6 seats but you only give an occupant load of 5. Please count seats rather than using 15sqft per occupant. ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf (11) Page: [1] A0.5 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: 25 seats = 25 occupants. Don't use 15sqft per occupant. Page: [1] A0.5 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Is this a 2nd exit? Where does it lead? Show the common path travel distance required by 2015 IBC table 1006.2.1. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Provide the slope of the self leveling underlayment as a height:length measurement or as a percent slope measurement. Greater than 1:20 (5%) becomes a ramp and will require handrails and landings. Also, detail how the thresholds at the doors are affected. 2015 IBC 1003.5, 2015 IEBC 410.8.5. Area Category Floor Area (ft2) Allowed Watts / ft2 Allowed Watts Types:Dining Area - Family Restaurant)1381 0.89 1229 e Types:Corridor/Transition <8 ft wide)131 0.66 86 ace Types:Corridor/Transition <8 ft wide)110 0.66 73 ypes:Restrooms)117 0.98 115 ce Types:Restrooms)119 0.98 117 1619Total Allowed Watts = hting Power E (C X D) D Fixture Watt. A Description / Lamp / Wattage Per Lamp / Ballast B Lamps/ Fixture C # of Fixture Types: Dining Area - Family Restaurant, 1381 sq.ft.) CESSED DOWNLIGHT RET: Other:1 21 12 252 SED DOWNLIGHT: Other:1 3 12 36 ED PINHOLE: Other:1 2 12 24 PLAY: Other:1 60 3 180 LIGHT: Other:1 26 3 78 ER: Other:1 64 3 192 PENDANT: Other:1 6 9 54 PENDANT: Other:1 6 10 60 PENDANT: Other:1 14 30 420 SCONCE: Other:1 8 11 88 ce Types: Corridor/Transition <8 ft wide, 131 sq.ft.) CESSED DOWNLIGHT RET: Other:1 6 12 72 pace Types: Corridor/Transition <8 ft wide, 110 sq.ft.) I count 13 DF1 fixtures on the lighting plan. WAITING (33 SF) 5 SF PER OCCUPANT:7 OCCUPANTS BANQUETTE (17'-1") 18" PER OCCUPANT:12 OCCUPANTS DINING (75 SF) 15 SF PER OCCUPANT: 5 OCCUPANTS OCCUPANT LOADOCCUPANT LOAD FACTORMIN. REQUIRED WIDTH (IN) PROPOSED C.O. WIDTH EXIT DOOR 101*50%=510.157.57" 34" (ACCESSIBLE) DIAG 1'- 7 " 1'- 7 " 1'- 7 " 3'-8" MIN. CLEAR EXIT WIDTH, TYP.29'-3 3/4"ADA 5'-0" ADA AD ADA There are 6 seats but you only give an occupant load of 5.Please count seats rather than using15sqft per occupant. K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS WAITING (33 SF)5 SF PER OCCUPANT:7 OCCUPANTS BANQUETTE (17'-1")18" PER OCCUPANT:12 OCCUPANTS DINING (75 SF)15 SF PER OCCUPANT:5 OCCUPANTS BOOTH (50'-2")24" PER OCCUPANT:25 OCCUPANTS DINING (220 SF)15 SF PER OCCUPANT:15 OCCUPANTS BANQUETTE (12'-6")18" PER OCCUPANT:9 OCCUPANTS CIRCULATIONNO OCCUPANCY CORRID N OCCUPANT LOADOCCUPANT LOAD FACTORMIN. REQUIRED WIDTH (IN)PROPOSED C.O. WIDTH EXIT DOOR RATING 101*50%=510.157.57"34" NR (ACCESSIBLE) N N NOT INSCOPE MAXIMUM EXIT ACCESS TRAVEL DISTANCE = 90'-4" DIAGON A L : 6 9 ' - 1 1 3 / 4 " 1'-7 " 1'- 7 " 1'-7"1 3'-8" MIN.CLEAR EXITWIDTH, TYP.29'-3 3/4"ADA 5'-0" ADA ADA ADA ADA File P a t h : P : \ P r o j - 2 0 1 8 \ 2 1 8 1 7 . 0 0 _ A j a x T a v e r n \ 0 6 _ D o c u m e n t a t i o n \ 0 1 _ D r a w i n g s \ 2 1 8 1 7 _ A 0 . 5 E G R E S S . d w g Plot D a t e / T i m e : O c t o b e r 0 8 , 2 0 1 8 - 4 : 2 9 p m 25 seats = 25occupants. Don't use15sqft per occupant. K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS SCALE: EGRESS & OCCUPANCY DIAGRAM 1/4" = 1'-0" 1 A0.5 PLANNORTH TRUENORTH CUPANT:NTS DINING (220 SF)15 SF PER OCCUPANT:15 OCCUPANTS BANQUETTE (12'-6")18" PER OCCUPANT:9 OCCUPANTS ASSEMBLY, W/O FIXED SEATING,UNCONCENTRATED ASSEMBLY W/ FIXED SEATING(BOOTH & BANQUETTE SEATING) ASSEMBLY, W/O FIXED SEATING,STANDING SPACE CODE PLAN LEGEND KITCHEN / SERVICE / BAR SERVICE CORRIDORNO OCCUPANCY NOT IN SCOPENOT INSCOPE MAXIMUM EXIT ACCESS TRAVEL DISTANCE = 90'-4" REFER TO SPECIFIC NOTES ON DRAWINGSFOR DETAILS REGARDING OCCUPANCYCALCULATIONS.(GRAPHIC LINE OFFSET FROM WALLS FORCLARITY, MEASUREMENTS CALCULATEDFROM FACE OF WALLS) ADA Is this a 2nd exit?Where does it lead?Show the commonpath travel distancerequired by 2015 IBCtable 1006.2.1. C D41'-2 1/4"16'-7 1/2"8'-7"K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS SCALE: PROPOSED FLOOR PLAN 1/4" = 1'-0" 1 A2.1 PLANNORTH TRUENORTH E E E E EXIST. EXIST. EXIST. SERVICE104 CORRIDOR106 BOHCORRIDOR107 WOMEN'SRESTROOM108 NEW BOOTHS W/ PULL-OUTSTORAGE BELOW NEW SERVICE STATION WITHGLASS & STEEL PARTITION ABOVE NEW BANQUETTEW/ STORAGEBELOW GMOFFICE SERVICEELEVATOR PROVIDE SELF-LEVELING FLOORUNDERLAYMENT AT HATCHED AREA TOEASE EXISTING STEP IN FLOOR SLOPE 1" : 1/16" EQ.EQ.EQ.EQ.EQ.38'-5 3/8"6 3/4"4'-2"3'-10"12'-4 1/4"4'-3 1/2"2'-2 3/4"1'-9 7/8"4'-2 1/2" 2'-2"3'-0"5'-0" NOT IN SCOPE Provide the slope ofthe self levelingunderlayment as aheight:lengthmeasurement or as apercent slopemeasurement. Greater than 1:20 (5%)becomes a ramp andwill require handrailsand landings. Also,detail how the thresholds at thedoors are affected.2015 IBC 1003.5,2015 IEBC 410.8.5. R+B RESPONSE: Refer to updated COMcheck R+B RESPONSE: Refer to updated A0.5 drawing R+B RESPONSE: Refer to updated A0.5 drawing R+B RESPONSE: Refer to updated A0.5 drawing R+B RESPONSE: Refer to updated A2.1 drawing. We went to field verify and the ramp slope is only H:1" grade difference between L:18" span. (1/16":18" = 0.03%). See image. DOOR DOOR See exhibit A below (pg 4) clip from current ComCheck dated 1/18/2019 DF2 6 fixtures DF4 4 fixtures 2/25/2019 Comments 3/01/2019 Updated Comments Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Detail the accessible bar seating area with all applicable dimensions including height and knee and toe clearance. 2015 IBC 1109.11. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Detail or note the threshold height (max 1/2" above finish on either side). 2015 IBC 1010.1.7. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Draw the door maneuvering clearspaces correctly on both side of each door. ICC A117.1-2009 section 404.2.3.2. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Show where accessible seating can occur. 5% but not less than one of each seating experience must be accessible. These spaces must be dispersed. 2015 IBC 1109.11. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Is there a cross slope or does this become a tripper? 1 2 3 4 5 6 7 8 71'-11 1/8" 8'-1 13/16"6'-9 5/8"16'-0 1/8"8'-1 1/16"16'-1 3/4"9'-8"7'-0 3/4" K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS HOST ADA EXTERIOR EXTERIOR 2A4.1 1A4.1 EE 1 2 E 1/100 EXIST. EXIST. EXIST. ENTRY100 BAR102 SERVICE104 KITCHEN105 CORRIDOR106 BOHCORRIDOR107 MEN'SRESTROOM109 WOMEN'SRESTROOM108 DINING103 SERVICEENTRY101 T. O. FINISH100'-0" T. O. FINISH100'-0" NEW CUSTOM SCREEN WALL& RETAIL DISPLAY & BENCH NEW BANQUETTE NEW WALL INFILL NEW WALL INFILL EXISTING AWNING ABOVETO REMAIN MOBILE HOST STAND NEW SERVICE STATION WITHGLASS & STEEL PARTITION ABOVE NEW BANQUETTEW/ STORAGEBELOW NEW POS SHELF T. O. FINISH100'-0" PROVIDE SELF-LEVELING FLOORUNDERLAYMENT AT HATCHED AREA SOFINISHED FLOOR ELEVATION = 100'-0",VERIFY EXTENTS IN FIELD SLOPE 1" : 1/16"EQ.EQ.EQ.EQ.EQ.9'-6 3/8"38'-5 3/8"3'-10"12'-4 1/4"4'-3 1/2"6'-8 1/2"1'-8"3'-3 1/2"2'-2 3/4"1'-9 7/8"4'-2 1/2" 2'-2"3'-0"5'-0"6'-8 3/8"4'-6 3/8"4'-4 5/8"1'-10"6 3/4"5'-2 7/8"1'-3 3/4"17'-0 1/8"1'-7"1'-1 5 / 8 " 9'-4 3/8" 10'-8 7/ 8 "2'-3"1'-7 1/4"4'-9" R6" R6"T. O. FINISH100'-0" NEW DRINK RAIL E 1'-0"NOT IN SCOPE 6 3/8"BENCH NEW FRAMED WALL 3 3/8 Detail the accessiblebar seating areawith all applicabledimensionsincluding height andknee and toeclearance. 2015 IBC1109.11. 1 2 3 4 5 71'-11 1/8" 8'-1 13/16"6'-9 5/8"16'-0 1/8"8'-1 1/16" HOST ADA EXTERIOR EXTERIOR 2A4.1 1A4.1 3A4.1 EE 1 2 E E E E E E 1/101 1/100 ENTRY100 BAR102 SERVICE104 KITCHEN105 C DINING103 SERVICEENTRY101 T. O. FINISH100'-0" T. O. FINISH100'-0" NEW CUSTOM SCREEN WALL& RETAIL DISPLAY & BENCH NEW BANQUETTE NEW BOOTHS W/ P STORAGE BELOW NEW WALL INFILL NEW WALL INFILL EXISTING AWNING ABOVETO REMAIN MOBILE HOST STAND NEW SERVICE STATION WITHGLASS & STEEL PARTITION ABOVE NEW BANQUETTEW/ STORAGEBELOW NEW POS SHELF T. O. FINISH100'-0" T. O. FINISH100'-0" PROVIDE SELF-LEVELING FLOORUNDERLAYMENT AT HATCHED AREA SOFINISHED FLOOR ELEVATION = 100'-0",VERIFY EXTENTS IN FIELD PROVIDE SELF-LEV UNDERLAYMENT A EASE EXISTING ST EQ.EQ.EQ.EQ.9'-6 3/8"38'-5 3/8"6 3/4"4'-2"3'-10"12'-4 1/4"4'-3 1/2"6'-8 1/2"1'-8"3'-3 1/2"2'-2 3/4"1'-9 7/8"4'-2 1/2" 2'-2"3'-0"5'-0"6'-8 3/8"4'-6 3/8"4'-4 5/8"1'-10"6 3/4"5'-2 7/8"1'-3 3/4"17'-0 1/8"1'-7"1'-1 5 / 8 " 9'-4 3/8" 10'-8 7 / 8 "2'-3"1'-7 1/4"4'-9" R6" R6"T. O. FINISH100'-0" NEW DRINK RAIL E 1'-0"6 3/8" BENCH NEW FRAMED WALL 3 3/8" Detail or note thethreshold height (max1/2" above finish oneither side). 2015IBC 1010.1.7. B C D41'-2 1/4"15'-11 3/4"16'-7 1/2"8'-7"K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS E EXIST. EXIST. EXIST. N CORRIDOR 106 BOHCORRIDOR107 MEN'SRESTROOM 109 WOMEN'SRESTROOM108 HS W/ PULL-OUT BELOW WITHBOVE GMOFFICE SERVICEELEVATOR ELF-LEVELING FLOOR MENT AT HATCHED AREA TOTING STEP IN FLOOR SLOPE 1" : 1/16" EQ. NOT IN SCOPE NOT IN SCOPE NEW COUNTER, SINK, AND FAUCET Issue: AJAX AT TH 675 EAS ASPEN, 05.24.18PRE DESIG 06.25.18 CLIENT M 07.13.18CLIENT M 08.01.18 PRELIMIN 08.17.18CLIENT M 09.11.18 LAND USE 10.09.18BUILDING Draw the doormaneuveringclearspaces correctlyon both side of eachdoor. ICCA117.1-2009 section404.2.3.2.15'-11 3/4"16'-7 1/2"8'-7"K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS SCALE: PROPOSED 1/4" 1 A2.1 HOST ADA EXTERIOR 2A4.1 1A4.1 3A4.1 EE 1 2 E E E E E E 1/101 1/100 EXIST. EXIST. EXIST. ENTRY100 BAR102 SERVICE104 KITCHEN105 CORRIDOR106 BOHCORRIDOR107 MEN'SRESTROOM109 WOMEN'SRESTROOM108 DINING103 SERVICEENTRY101 T. O. FINISH100'-0" T. O. FINISH100'-0" NEW CUSTOM SCREEN WALL& RETAIL DISPLAY & BENCH NEW BANQUETTE NEW BOOTHS W/ PULL-OUTSTORAGE BELOW NEW WALL INFILL NEW WALL INFILL EXISTING AWNING ABOVETO REMAIN MOBILE HOST STAND NEW SERVICE STATION WITHGLASS & STEEL PARTITION ABOVE NEW BANQUETTEW/ STORAGEBELOW NEW POS SHELF T. O. FINISH100'-0" T. O. FINISH100'-0" GMOFFICE SERVICEELEVATOR PROVIDE SELF-LEVELING FLOORUNDERLAYMENT AT HATCHED AREA TOEASE EXISTING STEP IN FLOOR SLOPE 1" : 1/16"EQ.EQ.EQ.EQ.EQ.9'-6 3/8"38'-5 3/8"6 3/4"4'-2"3'-10"12'-4 1/4"4'-3 1/2"6'-8 1/2"1'-8"3'-3 1/2"2'-2 3/4"1'-9 7/8"4'-2 1/2" 2'-2"3'-0"5'-0"6'-8 3/8"4'-6 3/8"4'-4 5/8"1'-10"6 3/4"5'-2 7/8"1'-3 3/4"17'-0 1/8"1'-7"1'-1 5 / 8 " 9'-4 3/8" 10'-8 7 /8 "2'-3"1'-7 1/4"4'-9" R6" R6"T. O. FINISH100'-0" E 1'-0"NOT IN SCOPE NOT IN SCOPE6 3/8"BENCH 3 3/8"File Path: P:\Proj-2018\21817.00_Ajax Tavern\06_Documentation\01_Drawings\21817_A2.1.dwgPlot Date / T i m e : O c t o b e r 0 9 , 2 0 1 8 - 3 : 0 4 p m Show whereaccessible seating canoccur. 5% but not lessthan one of eachseating experiencemust be accessible.These spaces must bedispersed. 2015 IBC1109.11. EXIST. EXIST. DOR 6 BOH CORRIDOR 107 R SERVICE SLOPE 1" : 1/16" Is there a cross slope or does this become a tripper? R+B RESPONSE: Refer to updated A2.1 drawing. We went to field verify and the ramp is only between the two doors. It does not extend this far. See image. NO SLOPE OR TRIPPER R+B RESPONSE: Refer to updated A2.1 and A9.2 drawing. Bar is now existing to remain, but we are extending the ADA section to include companion at 60" wide. R+B RESPONSE: Refer to updated A2.1 drawing for plan south-east door. Plan-North door has automatic door openers which we plan to keep. See image and plan for locations. Existing auto door opener to remain. Other location is at the interior of Men's bathroom. R+B RESPONSE: Refer to updated A2.1 drawing for new seating layout. One accessible seat added to each area. R+B RESPONSE: See note on A2.1 drawing. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: 2015 IEBC 410.7 requires up to 20% of the project valuation be spent towards improving the accessible route throughout to the primary function of the space and to the toilet rooms. This door does not comply with door maneuvering clearance requirements. Explore options to improve it; perhaps an automatic opener or two way swinging hinge. ICC A117.1-2009 section 404.2.3.2. Page: [1] A2.1 File Name: ARCH DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Provide an accessible clearspace in front of at least one lavatory in each toilet room. ICC A117.1-2009 section 606. Page: 3 File Name: KIT DWG SET.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Provide a type I hood for the rotisserie per 2015 IMC 507.2. Detail clearances to combustibles and ducting in compliance with all applicable requirements of 2015 IMC 506 and 507. KIT DWG SET.AJAX 675 E DURANT_2018-10 email.pdf (1) Page: COPYRIGHT 2018 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT IS•50THE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN•50DESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIOR•50WRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBAN•50DESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALL•50RETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,•50INCLUDING COPYRIGHT THERETO. File Name: MEP.AJAX 675 E DURANT_2018-10 email.pdf Subject: PlanCheck Author: nickt Color: Unless you can demonstrate that you have replaced less than 10% of the light fixtures and not increased the total lighting power, please demonstrate compliance with the lighting controls sections of 2015 IECC C405 for the new fixtures. This includes daylighting, occupancy sensors, and timers. (2015 IECC C503.6). MEP.AJAX 675 E DURANT_2018-10 email.pdf (1) A B C D41'-2 1/4"15'-11 3/4"16'-7 1/2"8'-7"K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS E EXIST. EXIST. EXIST. KITCHEN 105 CORRIDOR106 BOHCORRIDOR107 MEN'SRESTROOM109 WOMEN'SRESTROOM 108 EW BOOTHS W/ PULL-OUT STATION WITHTITION ABOVE GMOFFICE SERVICEELEVATOR ROVIDE SELF-LEVELING FLOORNDERLAYMENT AT HATCHED AREA TOASE EXISTING STEP IN FLOOR SLOPE 1" : 1/16" EQ. NOT IN SCOPE NOT IN SCOPE NEW COUNTER, SINK, AND FAUCET Issue: AJAX TAVER AT THE LITT 675 EAST DURAN ASPEN, COLORA 05.24.18 PRE DESIGN 06.25.18 CLIENT MEETING 07.13.18CLIENT MEETING 08.01.18PRELIMINARY PRICIN 08.17.18 CLIENT MEETING 09.11.18 LAND USE SUBMITTAL 10.09.18 BUILDING PERMIT SU 2015 IEBC 410.7 requires up to 20%of the project valuation be spenttowards improving the accessible route throughout to the primaryfunction of the space and to the toiletrooms. This door does not complywith door maneuvering clearance requirements. Explore options toimprove it; perhaps an automaticopener or two way swinging hinge.ICC A117.1-2009 section 404.2.3.2. A B C41'-2 1/4"15'-11 3/4"16'-7 1/2"K-14402-4PURISTFAUCETSBRASSK-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS K-14402-4PURISTFAUCETSBRASS EXIST. EXIST. EXIST. OR BOHCORRIDOR 107 MEN'SRESTROOM 109 WOMEN'SRESTROOM108 SLOPE 1" : 1/16" NOT IN SCOPE NEW COUNTER, SINK, AND FAUCET Provide an accessible clearspace in front of at least one lavatory in each toilet room. ICC A117.1-2009 section 606. DISH PREP A1 A4A2A2.1 A11 A11 A12 A8 A7 A5 A6A5.1A13 A14 B1 B1.1 B4 B12 B16 B17 B14 B18 nt Plan ule - (B) Remarks By Millwork By Millwork Existing - Relocated Existing - Relocated Existing - Relocated Existing - Relocated Existing - Relocated Existing - Relocated Existing - Relocated Provide a type I hood forthe rotisserie per 2015 IMC 507.2. Detailclearances to combustibles and ductingin compliance with allapplicable requirements of 2015 IMC 506 and507. Unless you can demonstrate that you have replaced less than 10% of the light fixtures and not increased the total lighting power, please demonstrate compliance with the lighting controls sections of 2015 IECC C405 for the new fixtures. This includes daylighting, occupancy sensors, and timers. (2015 IECC C503.6). R+B RESPONSE: Refer to Ricca;s updated drawings and specs. Existing auto door opener to remain. Other location is at the interior of Men's bathroom. R+B RESPONSE: Refer to updated A2.1 drawing for added clearances at lavatories. 2015 IECC 405.2.1 that Restaurant isn’t one of the “space types” that need sensors. (not sure if I am interpreting this correctly?) Also in C405.2.2 “Time-switch controls” it says that Exception… “Spaces where an automatic shutoff would endanger occupant safely or security” which I feel restaurant would count for. I'm not finding a C503.6. We are replacing more than 10% of lighting. See plan LT 1.01 dated 2/25/2019 for compliance with 2015 IECC C405 and C503.6. Exhibit A - Clip from ComCheck 1/18/2019