HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0009.2019 (4).ACBK0009-2019-ACBK_BuildingComment2 Subject: PlanCheck Page Label: 1 Author: justinh File Name: 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf Color: Not addressed, revised ComCheck still shows 90.1 (2007) edition, revise to use either the 2015 IECC or 2013 edition of ASHRAE 90.1. 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf (5) Subject: PlanCheck Page Label: 2 Author: justinh File Name: 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf Color: I do not see how this has been changed. A2.1 calls this out as a pantry area which we would consider to be a back of house type of space. Please clarify how this original comment has been addressed. Subject: PlanCheck Page Label: 2 Author: justinh File Name: 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf Color: No dimensions or notes were added to A0.5, comment not addressed. Subject: PlanCheck Page Label: 3 Author: justinh File Name: 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf Color: From what I can tell only the accessible bar seating is shown on A0.5, 5% of all seating must be accessible with compliant approaches to be shown. Now that furniture is being shown on the egress plan you have several spots where tables are shown in areas shaded as egress paths. Revise plan to clearly show your routes and approaches to all accessible seating clear of obstructions. Subject: PlanCheck Page Label: 3 Author: justinh File Name: 00_0009-2019-ACBK_BuildingComment1 - RB RESPONSE.pdf Color: Forward approaches at seats should always be shown tucked 17" into the table/bar to demonstrate you have compliant knee and toe clearance, please revise. 0009-2019-ACBK_BuildingComment1 Subject: PlanCheckPage Label: 1Author: justinhFile Name: 10_COMCHECK.675 E DURANT_2019-02 rev3_2019-03-12.pdfColor: Revise your ComCheck to be onthe 2013 edition of ASHRAE90.1, the 2015 IECC references90.1 2013 rather than 2007. 10_COMCHECK.675 E DURANT_2019-02 rev3_2019-03-12.pdf (3) Subject: PlanCheckPage Label: 1Author: justinhFile Name: 10_COMCHECK.675 E DURANT_2019-02 rev3_2019-03-12.pdfColor: Completely fill out theowner/agent and designercontractor portions of this report. Subject: PlanCheckPage Label: 2Author: justinhFile Name: 10_COMCHECK.675 E DURANT_2019-02 rev3_2019-03-12.pdfColor: Please sign your ComCheckreport 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdf (11) Mcheck Software Version 4.1.0.0terior Lighting Compliance Certificate 90.1 (2007) StandardAlteration Owner/Agent:ASPEN SKIING COMPANY Designer/Contractor: n The Little Nell - Lobby + Chair 9 ghting PowerAArea Category BFloor Area(ft2)CAllowedWatts / ft2 DAllowed Watts(B X C)(Hotel/Motel:Hotel Lobby)1478 1.10 1626 Revise yourComCheck to be onthe 2013 edition ofASHRAE 90.1, the2015 IECC references90.1 2013 rather than2007. COMcheck Software Version 4.1.0.0Interior Lighting Compliance Certificate 90.1 (2007) StandardAlteration ve11 Owner/Agent:ASPEN SKIING COMPANY Designer/Contractor: mation The Little Nell - Lobby + Chair 9 or Lighting PowerAArea Category BFloor Area(ft2)CAllowedWatts / ft2 DAllowed Watts(B X C)cierge (Hotel/Motel:Hotel Lobby)1478 1.10 1626tel/Motel:Hotel Lobby)1283 1.10 1411otel:Hotel Dining Area)1576 1.30 2049on Space Types:Corridor/Transition)734 0.50 367Space Types:Stairs-Active)122 0.60 73 Space Types:Office - Enclosed)500 1.10 5506076Total Allowed Watts =rior Lighting Power E(C X D)DFixtureWatt.Aure ID : Description / Lamp / Wattage Per Lamp / Ballast BLamps/Fixture C# ofFixturesncierge ( Hotel/Motel:Hotel Lobby 1478 sq.ft.)CESSED DOWNLIGHT: Other:1 8 13 104CESSED COMBO DOWNLIGHT: Other:2 6 26 156 Completely fill out theowner/agent anddesigner contractorportions of this report. LED 21: F16: SURFACE MOUNTED LINEAR LIGHT: Other:1 5 2 12LED 22: F21: RECESSED DOWNLIGHT: Other:1 2 12 25LED 23: DF: WALL MOUNTED DECORATIVE SCONCE: Other:1 8 13104LED 31: F17: RECESSED STEP LIGHT: Other:1 4 3 10LED 33: F5A: RECESSED SMALL DOWNLIGHT: Other:1 5 7 35LED 34: F18: SURFACE MOUNTED LINEAR LED STRI: Other:1 20 2 50Corridor ( Common Space Types:Corridor/Transition 734 sq.ft.)LED 25: F19: RECESSED DOWNLIGHT: Other:1 13 18234LED 27: F7: RECESSED COVE LIGHT: Other:1 81 3243LED 35: F17A: RECESSED STEP LIGHT: Other:1 4 3 10Stairs ( Common Space Types:Stairs-Active 122 sq.ft.)LED 30: F19: RECESSED DOWNLIGHT: Other:1 6 12 75Office ( Common Space Types:Office - Enclosed 500 sq.ft.)LED 32: F21: RECESSED DOWNLIGHT: Other:1 9 121123602Total Proposed Watts =Interior Lighting Compliance StatementCompliance Statement: The proposed interior lighting alteration project represented in this document is consistent with thebuilding plans, specifications, and other calculations submitted with this permit application. The proposed interior lightingsystems have been designed to meet the 90.1 (2007) Standard requirements in COMcheck Version 4.1.0.0 and to comply withany applicable mandatory requirements listed in the Inspection Checklist.Name - Title Signature Date Interior Lighting PASSES Please sign yourComCheck report R+B RESPONSESEE NEW COMCHECKDATED 2019-03-18 R+B RESPONSESEE NEW COMCHECKDATED 2019-03-18 R+B RESPONSESEE NEW COMCHECKDATED 2019-03-18 Not addressed, revised ComCheck still shows 90.1 (2007) edition, revise to use either the 2015 IECC or 2013 edition ofASHRAE 90.1. Subject: PlanCheckPage Label: [1] _KGM-TLN_LIGHTING PLAN_FOR VE-LT2.04Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Please dimension the distancebetween adjacent tables, 38" isthe minimum required for back toback seating at tables per IBC1029.12.1. Subject: PlanCheckPage Label: [1] 21808_A0.5 EGRESS 2-A0.5Author: justinh File Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Your accessible route cannotpass through a back of housespace. IEBC 410.3 does notallow an alteration to reduce theaccessibility of an area, whichthis new pantry space does. Wewill accept the existing conditionhere, but you cannot create aneven more defined back ofhouse area by adding a wall ifyour accessible route passesthrough it. Subject: PlanCheckPage Label: [1] 21808_A0.5 EGRESS 2-A0.5Author: justinh File Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Please revise your scale to bethe accurate scale for yourdrawings (1/8" per mymeasurements) Subject: PlanCheckPage Label: [1] LT1.00Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: It appears that daylightresponsive lighting controls willbe required along these windows per IECC C405.2.3. Revise the plans to show the daylight zonesand call out the requirement fordaylight responsive controls orshow how you meet anexception to this requirement. Subject: PlanCheckPage Label: 18 Doors 105A and 124A are also F15 DF F17 F16 B5 C9 C6 F17 F17F17ID-6.138 ID-6.203 F17AF17AF17AF17A B6 PROVIDE POWER ONL FIXTURE PROVIDED BY MANUFACTURER PROVIDE POWER ONLY FIXTURE PROVIDED BY MANUFACTURER Please dimension thedistance betweenadjacent tables, 38" isthe minimum requiredfor back to backseating at tables perIBC 1029.12.1. EGRESS PATH EGRESS P A T HACCESSIBLE PATHEGRESS PATH LIVING ROOM LOUNGE LIVING ROOM NOT IN SCOPE 111'-1 0 " ACCESSIBLE PATH 3'-8" 3'-8" Your accessible route cannot passthrough a back of house space. IEBC410.3 does not allow an alteration toreduce the accessibility of an area,which this new pantry space does. We will accept the existing conditionhere, but you cannot create an evenmore defined back of house area byadding a wall if your accessible routepasses through it. SCALE:EGRESS & OCCUPANCY DIAGRAM1/16" = 1'-0" 1A0.5 PLANNORTH TRUENORTH 5 SF NET 40 40 PUBLICTOTAL PUBLIC 404TOTAL EMPLOYEE 8TOTAL OCCUPANTS 412 Please revise yourscale to be theaccurate scale for yourdrawings (1/8" per mymeasurements) F1 F1 F1F1F1 F1 F1 F1 F1F1 F2F2F2F2 F4 F4F4F4 F4 F19 F19 F19 F3 F6F6F6F6 F7 F19F19F19F19F19F19 F19 F19 F8 F8 F8 F10 (14)F9 DF DFDF DF DF DF (3)F12(3)F12(3)F12 (3)F12 (3)F12 (3)F12 F12F12 F12 F12 F12 F12 F12 F12 F12 F12 F12 F12F12 F12 F12 F12F12 F12F12 F12F12 F15 F16(3)F18 F3 F2F2F2 F2F2F2 F12 F12 F19F1 DF DF LT2.02LT2.01 F19 (3)F12F7 F21F21 F17 F15 F8 F16 ID-6.148 F17 F17F17 F9 ID-6.138 ID-6.203 F17AF17AF17AF17A DF DF F10A (5) F5AF5A F5AF5A F5A F19 F19 F19 F12 F12F12 F12F12F12 It appears that daylight responsive lightingcontrols will be required along these windowsper IECC C405.2.3. Revise the plans to showthe daylight zones and call out the requirementfor daylight responsive controls or show howyou meet an exception to this requirement. Doors 105A and 124A R+B RESPONSEADDED DIMENSIONSAND NOTES TO PLAN A0.5 R+B RESPONSE SEE UPDATED A0.5 EGRESS PLANSHOWING VESTIBULE TOPASS THROUGH FOR ACCESSIBILITY R+B RESPONSE SEE A0.5 FORACCURATE SCALE R+B RESPONSESEE PLAN LT2.01 and LT2.02AND EXHIBIT A BELOW FOREXEMPTION TO C405.2.3 I do not see how this has been changed. A2.1 calls this out as a pantry area which we would consider tobe a back of housetype of space. Pleaseclarify how this originalcomment has beenaddressed. Subject: PlanCheckPage Label: [1] _KGM-TLN_LIGHTING PLAN_FOR VE-LT2.04 Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Please dimension the distancebetween adjacent tables, 38" isthe minimum required for back toback seating at tables per IBC 1029.12.1. Subject: PlanCheck Page Label: [1] 21808_A0.5 EGRESS 2-A0.5 Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Your accessible route cannotpass through a back of housespace. IEBC 410.3 does notallow an alteration to reduce the accessibility of an area, which this new pantry space does. Wewill accept the existing conditionhere, but you cannot create aneven more defined back ofhouse area by adding a wall ifyour accessible route passesthrough it. Subject: PlanCheck Page Label: [1] 21808_A0.5 EGRESS 2-A0.5 Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Please revise your scale to bethe accurate scale for yourdrawings (1/8" per my measurements) Subject: PlanCheck F15 DF F17 F16 B5 C9 C6 F17 F17F17ID-6.138 ID-6.203 F17AF17AF17AF17A B6 PROVIDE POWER ONL FIXTURE PROVIDED BY MANUFACTURER PROVIDE POWER ONLY FIXTURE PROVIDED BY MANUFACTURER Please dimension thedistance betweenadjacent tables, 38" isthe minimum requiredfor back to backseating at tables perIBC 1029.12.1. EGRESS PATH EGRESS P A T H ACCES S I B L E P A T H EGRESS PATH LIVING ROOM LOUNGE LIVING ROOM NOT IN SCOPE 111'-10 " ACCESSIBLE PATH 3'-8"3'-8" Your accessible route cannot passthrough a back of house space. IEBC410.3 does not allow an alteration toreduce the accessibility of an area,which this new pantry space does. We will accept the existing conditionhere, but you cannot create an evenmore defined back of house area byadding a wall if your accessible routepasses through it. SCALE:EGRESS & OCCUPANCY DIAGRAM1/16" = 1'-0" 1A0.5 PLANNORTH TRUENORTH 5 SF NET 40 40 PUBLICTOTAL PUBLIC 404TOTAL EMPLOYEE 8TOTAL OCCUPANTS 412 Please revise yourscale to be theaccurate scale for yourdrawings (1/8" per mymeasurements) R+B RESPONSE ADDED DIMENSIONSAND NOTES TOPLAN A0.5 R+B RESPONSE SEE UPDATED A0.5 EGRESS PLANSHOWING VESTIBULE TOPASS THROUGH FOR ACCESSIBILITY R+B RESPONSE SEE A0.5 FORACCURATE SCALE No dimensions or notes were added to A0.5, comment notaddressed. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Identify your accessible seating,show the required approaches tothese seats, call out tableheights at accessible seating,and demonstrate that you areproviding at least 5% of yourtotal seating as accessibleseating. Approaches to youraccessible seating may notoverlap into the accessibleroutes. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: You are required to provide 2accessible spaces at your bar (1accessible space with acompanion space). Show therequired approaches to the twoseats and demonstrate that theaccessible portion of the bar willmeet the requirements of ANSI902 for height and knee and toeclearance. Subject: PlanCheckPage Label: 26Author: justinh File Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Raised seating areas will not beaccepted without an accessibleroute, IBC 1108.2.9 requires allinterior and exterior floor areasto be accessible within diningareas. You are demolishingthem per your demo plan andthey are not shown as beingreplaced in the proposed floor SCALE: 1/4" = 1'-0"1Level 1 Equipment Plan Identify your accessible seating, show the required approaches to these seats,call out table heights at accessible seating, and demonstrate that you areproviding at least 5% of your total seating as accessible seating. Approachesto your accessible seating may not overlap into the accessible routes. A1A1.2 A2A3A6 A6.1 A8A11A12A6 A6.1 A3 A13 A21A17A18A18A21A21 A6.2A6.2 A23A1.3A24 A22A6.1 A6A6.2A16 A21A20.1A20 A19 A25.2A25A25.1 A25.3 1 1 1 1 11 You are required toprovide 2 accessiblespaces at your bar (1accessible space witha companion space). Show the requiredapproaches to the twoseats anddemonstrate that theaccessible portion ofthe bar will meet therequirements of ANSI902 for height andknee and toeclearance. A1A1.2A2A3A6 A6.1 A8A11A12A6 A6.1 A3 A13 A21A17A18A18A21A21 A6.2A6.2A23A1.3A24 A22 A26 A27A28A34A33A31A32A33.1A34.1 A6.1 A6A6.2A16 A21A20.1A20 A28.1 A19A25.2A25A25.1 A25.3 1 1 Foodservice Eq Item Number Qty Des A1 1 Bar TopA1.1 1 Modular Bar Die SystemA1.2 1 Drink RailA1.3 1 Beer TowerA2 1 Blender Station A3 2 Liquor Display Steps A4 1 Spare NumberA5 1 Spare NumberA6 3 Cocktail Station A6.1 3 Speed Rail A6.2 3 Soda Gun Holder A7 1 Spare NumberA8 1 Hand Sink with Soap And A9 1 Spare NumberA10 1 Spare NumberA11 1 Dump Sink with Trash Chu A12 1 DrainboardA12.1 1 Speed Rail A13 1 GlasswasherA14 1 Spare NumberA15 1 Spare NumberA16 1 Blender StationA17 1 Back Bar Counter A18 2 Back Bar Cooler A19 1 Service Station A20 1 Service Station A20.1 1 Water Station With Pedest A21 4 POS System A22 1 Enomatic Wine DispenserA23 1 Beer System Conduit Exit A24 1 Soda System Conduit Exit A25 1 Sparkling Water Dispense A25.1 1 Water Carbonator/ChillerA25.2 1 Water Filtration SystemA25.3 1 Drip TrayA26 1 Service Station A27 1 POS System A28 1 Bussing Counter A28.1 1 Sink, Drop-inA29 1 Spare NumberA30 1 Spare NumberA31 1 Popcorn Popper A32 1 Wine RefrigeratorA33 1 Espresso Machine A33.1 1 Water Filtration SystemA34 1 Coffee Brewer A34.1 1 Water Filtration System SCALE: 1/4" = 1'-0"1Level 1 Equipment Plan 1 11 11 1 Raised seating areas will not be acceptedwithout an accessible route, IBC 1108.2.9requires all interior and exterior floorareas to be accessible within diningareas. You are demolishing them peryour demo plan and they are not shownas being replaced in the proposed floorplan, please clarify what is actuallyproposed and make sure that it is showncorrectly and consistently throughout theentire set. R+B RESPONSEA0.5 FOR ADDEDNOTES R+B RESPONSE SEE A7.1 FORSECTION AND A0.5 R+B RESPONSE PLATFORMS ARE BEINGREMOVED AND HAVEADJUSTED THROUGH SET From what I can tellonly the accessiblebar seating is shown on A0.5, 5% of all seating must beaccessible withcompliant approachesto be shown. Now that furniture is being shown on the egressplan you have severalspots where tablesare shown in areas shaded as egress paths. Revise plan to clearly show yourroutes andapproaches to allaccessible seating clear of obstructions. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Identify your accessible seating,show the required approaches tothese seats, call out tableheights at accessible seating,and demonstrate that you areproviding at least 5% of yourtotal seating as accessibleseating. Approaches to youraccessible seating may notoverlap into the accessibleroutes. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: You are required to provide 2accessible spaces at your bar (1accessible space with acompanion space). Show therequired approaches to the twoseats and demonstrate that theaccessible portion of the bar willmeet the requirements of ANSI902 for height and knee and toeclearance. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Raised seating areas will not beaccepted without an accessibleroute, IBC 1108.2.9 requires allinterior and exterior floor areasto be accessible within diningareas. You are demolishingthem per your demo plan andthey are not shown as beingreplaced in the proposed floorplan, please clarify what isactually proposed and makesure that it is shown correctlyand consistently throughout theentire set. Subject: PlanCheckPage Label: 26Author: justinhFile Name: 16_Permit Drawing Set.675 E DURANT_2019-02_rev.pdfColor: Remove this notation from allapplicable plans, we will notissue plans marked "not forconstruction". SCALE: 1/4" = 1'-0"1Level 1 Equipment Plan Identify your accessible seating, show the required approaches to these seats,call out table heights at accessible seating, and demonstrate that you areproviding at least 5% of your total seating as accessible seating. Approachesto your accessible seating may not overlap into the accessible routes. A1A1.2 A2A3A6 A6.1 A8A11A12A6 A6.1 A3 A13 A21A17A18A18A21A21 A6.2A6.2 A23A1.3A24 A22A6.1 A6A6.2A16 A21A20.1A20 A19 A25.2A25A25.1 A25.3 1 1 1 1 11 You are required toprovide 2 accessiblespaces at your bar (1accessible space witha companion space). Show the requiredapproaches to the twoseats anddemonstrate that theaccessible portion ofthe bar will meet therequirements of ANSI902 for height andknee and toeclearance. A1A1.2 A2A3A6 A6.1 A8A11A12A6 A6.1 A3 A13 A21A17A18A18A21A21 A6.2A6.2A23A1.3A24 A22 A26 A27A28A34A33A31A32A33.1A34.1 A6.1 A6A6.2A16 A21A20.1A20 A28.1 A19A25.2A25A25.1 A25.3 1 1 Foodservice Eq Item Number Qty Des A1 1 Bar TopA1.1 1 Modular Bar Die SystemA1.2 1 Drink RailA1.3 1 Beer TowerA2 1 Blender Station A3 2 Liquor Display Steps A4 1 Spare NumberA5 1 Spare NumberA6 3 Cocktail Station A6.1 3 Speed Rail A6.2 3 Soda Gun Holder A7 1 Spare NumberA8 1 Hand Sink with Soap And A9 1 Spare NumberA10 1 Spare NumberA11 1 Dump Sink with Trash Chu A12 1 DrainboardA12.1 1 Speed Rail A13 1 GlasswasherA14 1 Spare NumberA15 1 Spare NumberA16 1 Blender StationA17 1 Back Bar Counter A18 2 Back Bar Cooler A19 1 Service Station A20 1 Service Station A20.1 1 Water Station With Pedest A21 4 POS System A22 1 Enomatic Wine DispenserA23 1 Beer System Conduit Exit A24 1 Soda System Conduit Exit A25 1 Sparkling Water Dispense A25.1 1 Water Carbonator/ChillerA25.2 1 Water Filtration SystemA25.3 1 Drip TrayA26 1 Service Station A27 1 POS System A28 1 Bussing Counter A28.1 1 Sink, Drop-inA29 1 Spare NumberA30 1 Spare NumberA31 1 Popcorn Popper A32 1 Wine RefrigeratorA33 1 Espresso Machine A33.1 1 Water Filtration SystemA34 1 Coffee Brewer A34.1 1 Water Filtration System SCALE: 1/4" = 1'-0"1Level 1 Equipment Plan 1 1 1 11 1 Raised seating areas will not be acceptedwithout an accessible route, IBC 1108.2.9requires all interior and exterior floorareas to be accessible within diningareas. You are demolishing them peryour demo plan and they are not shownas being replaced in the proposed floorplan, please clarify what is actuallyproposed and make sure that it is showncorrectly and consistently throughout theentire set. COPYRIGHT 2019 ROWLAND+BROUGHTON ARC THE INFORMATION AND DESIGN INTENT CON THE PROPERTY OF ROWLAND+BROUGHTON AR DESIGN. NO PART OF THIS INFORMATION MAY B WRITTEN PERMISSION OF ROWLAND+BROUGHT DESIGN. ROWLAND+BROUGHTON ARCHITECTU RETAIN ALL COMMON LAW STATUTORY AND OT INCLUDING COPYRIGHT THERETO. SHEET TITLE PROJECT NO: SCALE: 21808.00 5325 South Valentia Way, Green Phone 303 221 0500 Fax 303 2 www.ricca.com NOT FOR CONSTRUCTION 1/4" = 1'- Foodservice Pla QF40 07/07/17 Remove this notationfrom all applicableplans, we will notissue plans marked"not for construction". R+B RESPONSE REMOVED - SEE NEWRICCADATED 2019-03-15 REV 1 R+B RESPONSEA0.5 FOR ADDEDNOTES R+B RESPONSESEE A7.1 FORSECTION AND A0.5 R+B RESPONSE PLATFORMS ARE BEINGREMOVED AND HAVEADJUSTED THROUGH SET IN LIGHTING AND RICCAUPDATES ATTACHED Forward approaches at seats should always be shown tucked 17" into the table/bar to demonstrate you have compliant knee and toe clearance, please revise. ??? Subject: PlanCheck Page Label: 1 Author: justinh File Name: 16a_A0.5_EGRESS_2019-03-15.pdf Color: Provide a detail for your proposed knee and toe clearance under the accessible portion of the bar and dimension the height of the bar itself to show compliance with ANSI 902. Your standard details on A0.4 do not cover this adequately. 16a_A0.5_EGRESS_2019-03-15.pdf (3) Subject: PlanCheck Page Label: 1 Author: justinh File Name: 16a_A0.5_EGRESS_2019-03-15.pdf Color: You are still showing furniture in egress paths, previous comment not fully addressed. Revise to show all egress paths as being clear of all obstructions. Subject: PlanCheck Page Label: 1 Author: justinh File Name: 16a_A0.5_EGRESS_2019-03-15.pdf Color: What are these black boxes that now appear throughout the plan? I assume this is just an error and they were not meant to be shown. Please clarify or revise. Subject: PlanCheck Page Label: [1] _KGM-TLN_LIGHTING PLAN_FOR VE-LT1.00 Author: justinh File Name: 16k_KGM-TLN-LOBBY_C9_LIGHTING PLAN_190319.pdf Color: These custom light fixtures are not being accounted for in the ComCheck report. Per the provided info regarding this it appears to be a LED strip powered by a separate driver, but no specifics were given. Provide a cutsheet on the LED strip driver for the fixtures and identify the proposed quantity of drivers for these fixtures on the plan. The driver wattage and quantity are the values that should be used on the ComCheck for this fixture as that is what will determine the power these fixtures actually use. 16k_KGM-TLN-LOBBY_C9_LIGHTING PLAN_190319.pdf (1) Provide a detail for your proposed knee and toe clearance under the accessible portion of the bar and dimension the height of the bar itself to show compliance with ANSI 902. Your standard details on A0.4 do not cover this adequately. You are still showing furniture in egress paths, previous comment not fully addressed. Revise to show all egress paths as being clear of all obstructions. What are these black boxes that now appear throughout the plan? I assume this is just an error and they were not meant to be shown. Please clarify or revise. F1 F1 F19 F19 F19 F19 F8 DF DF DF DF DF DF (3)F12 (3)F12 (3)F12 (3)F12 (3)F12 (3)F12 F12F12 F12 F12 F12 F12 F12 F12 F12 F12 F12 F12 F12 F12F12F12 F12 F12 F12 F12 F15 F16(3)F18 F2 F12 F12 DF LT2.02 LT2.01 (3)F F21 F21 F17 F15 F16ID-6.148F17 F17F17 ID-6.138ID-6.203 F F17A DF DF F5AF5A F5AF5A F5A F19 F1 F1 F12 F12 F12 F12 F12 F12 F12 These custom light fixtures are notbeing accounted for in the ComCheck report. Per the provided info regarding this it appears to be a LED strip powered by a separate driver, but no specifics were given. Provide a cutsheet on the LED strip driver for the fixtures and identify the proposedquantity of drivers for these fixtures onthe plan. The driver wattage and quantity are the values that should be used on the ComCheck for this fixture as that is what will determine the power these fixtures actually use.