HomeMy WebLinkAboutFile Documents.675 E Durant Ave.0009.2019 (15).ACBKSCALE:EGRESS & OCCUPANCY DIAGRAM1/8" = 1'-0" 1A0.5PLANNORTHTRUENORTHPLUMBING FIXTURES :OCCUPANCY: A-2, RESTAURANTS - COUNT COMPLIES WITH OCCUPANCY, NO CHANGE TO COUNTSVITREOUS CHINABATHROOM SINKCAXTONK-20000VITREOUS CHINABATHROOM SINKCAXTONK-20000VITREOUS CHINABATHROOM SINKCAXTONK-20000 VITREOUS CHINABATHROOM SINKCAXTONK-20000
87654321EDCBAXYZY.7X.3I.9VU20'-0"20'-0"20'-0"20'-0"20'-0"23'-6"23'-0"20'-0"20'-0"20'-0"25'-6"21'-0"18'-0 3/8"18'-0 3/8"21'-0"32"TLN PUBLIC SPACES & CHAIR 9 OCCUPANT LOAD CALCULATIONUPDATED2019.01.18SPACEFUNCTION OF SPACE(per IBC Table 1004.1.1)UNIT PEROCCUPANTMEASUREMENT TYPEMEASUREMENTFOR OCC. LOADROOMOCCUPANTLOADACCESSORYUSEADJUSTMENTADJUSTEDOCCUPANT LOADNOTESFOYER, RECEPTION,CONCIERGE, CORRIDORASSEMBLY, UNCONCENTRATED15SF NET1016.06868PUBLICOFFICESBUSINESS100SF GROSS486.255EMPLOYEERESTROOMSASSEMBLY, UNCONCENTRATED,ACCESSORY15SF NET404.127-27ACCESSORYUPPER LOUNGEASSEMBLY, UNCONCENTRATED15SF NET254.51717PUBLICLIVING ROOMASSEMBLY, UNCONCENTRATED15SF NET685.34646PUBLICCONCIERGEWORKROOM/ LUGGAGEACCESSORY STORAGE AREA300SF GROSS296.711EMPLOYEEBAR SEATINGASSEMBLY, CONCENTRATED5SF NET62.21313PUBLICLOUNGE SEATINGASSEMBLY, UNCONCENTRATED15SF NET1033.769207PUBLICBAR SERVICEKITCHEN, COMMERICAL200SF GROSS251.522EMPLOYEEELEMENT 47ASSEMBLY, UNCONCENTRATED15SF NET3232PUBLICELEMENT 47ASSEMBLY, CONCENTRATED5SF NET4040PUBLICTOTAL PUBLIC404TOTAL EMPLOYEE8TOTAL OCCUPANTS4123'-2"3'-2"3'-2"3'-2"3'-2"6'-0"3'-2"PLUMBING FIXTURE CALCULATIONS412 OCCUPANTS / 2206 OCCUPANTS EACH SEX206/ 75 OCCUPANTS PER FIXTURE = 2.741 LAVATORY EACH SEX1 FIXTURE EACH SEX412/ 200 OCCUPANTS PER LAVATORY = 2.06NOTE: DRINKING WATER TO BEPROVIDED WITHIN RESTAURANT412 / 500 OCCUPANTS PER DRINKING FOUNTAIN2 SERVICE SINK TOTALOTHERINTERIOR FINISHES MINIMUM PERFORMACE REQUIREMENTS:INTERIOR WALL AND CEILING FINISHES: CLASS C(FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450; PER ASTM E 84 OR UL 723)INTERIOR FLOORING: CLASS II PER NFPA 253 OR TRADITIONAL TYPE MATERIALS SUCH AS WOOD,VINYL, LINOLEUM, TERRAZZO, AND RESILIENT FLOOR COVERING WITH NO FIBERSINTERIOR TRIM: CLASS C FLAME SPREAD & SMOKE DEVELOPED INDEX. COMBUSTIBLE TRIMACCEPTABLE PROVIDED IT DOES NOT EXCEED 10% OF WALL/CEILING AREA IT IS ATTACHED TOMEANS OF EGRESSMIN. SIZE OF DOORS: NOT LESS THAN 32" CLEAR DOOR FACE TO DOOR STOPMIN. EGRESS WIDTH:.15" * 412 OCCUPANTS = 15.15" / 2 EXITS = 7.57"THEREFORE 32" CLEAR MIN. REQUIRED36" DOORS PROVIDEDEXIT ACCESS TRAVEL DISTANCE:250' MAX (A OCCUPANCY, FULLY SPRINKLED)EXIT SEPARATION:THE BUILDING IS EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM, THE SEPARATION DISTANCE OF THE EXIT DOORS SHALL NOTBE LESS THAN ONE-THIRD OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE AREA SERVED.MAX DIAGONAL DIMENSION = 111'-10"1/3 OF MAX DIAGONAL DIMENSION = 37'- 4"ACTUAL DISTANCE BETWEEN EXITS = 53'-8" (COMPLIES)COMMON PATH OF EGRESS TRAVEL:NO GREATER THAN 75' (30' TO AISLES IN AREAS SERVINGMORE THAN 50 OCCUPANTS).MINIMUM NUMBER OF EXITS:2 (OCCUPANT LOAD GREATER THAN 49 AND LESS THAN 500)3 PROVIDED (2 ARE ACCESSIBLE MEANS OF EGRESS)FOR EXIT ILLUMINATION, SIGNS, & EMERGENCY POWER, RE: ELECTRICAL DRAWINGS.OCCUPANT LOAD CALCULATIONSGENERAL NOTESSEATING LAYOUT SHALL CONFORM WITH IBC 1029.12.1WHERE SEATING IS LOCATED AT A TABLE OR COUNTER AND IS ADJACENT TO AN AISLE OR AISLEACCESSWAY, THE MEASUREMENT OF REQUIRED CLEAR WIDTH OF THE AISLE OR AISLE ACCESSWAY SHALLBE MADE TO A LINE 19" AWAY FROM AND PARALLEL TO THE EDGE OF THE TABLE OR COUNTER.AISLE ACCESSWAYS SHALL PROVIDE A MINIMUM OF 12" WIDTH PLUS 12" FOR EACH ADDITIONAL 1', ORFRACTION THEREOF, BEYOND 12' OF AISLE ACCESSWAY LENGTH MEASURE FROM THE CENTER OF THE SEATFARTHEST FROM AN AISLE.PER IBC 1108.2.9.1, AT LEAST 5% OF DINING SURFACES SHOULD BE ACCESSIBLE.CHAIR 9:30 SEATS x .05 = 1.52 ACCESSIBLE SEATS SHOWN ON PLANLIVING ROOM:23 SEATS x .05 = 1.152 ACCESSIBLE SEATS SHOWN ON PLANKITCHEN, COMMERCIALASSEMBLY, W/O FIXED SEATING,STANDING SPACECODE PLAN LEGENDACCESSORY STORAGEACCESSORY RESTROOM AREAASSEMBLY, W/O FIXED SEATING(CONCENTRATED)REFER TO SPECIFIC NOTES ON DRAWINGSFOR DETAILS REGARDING OCCUPANCYCALCULATIONS.(GRAPHIC LINE OFFSET FROM WALLS FORCLARITY, MEASUREMENTS CALCULATEDFROM FACE OF WALLS)BUSINESSEGRESS PATHEGRESS PATHOFFICESWOMEN'SRESTROOMSUPPER LOUNGELIVING ROOMNOT IN SCOPENOT IN SCOPENOT IN SCOPENOT IN SCOPEDOOR STOPDOOR FACECLEARMEN'SRESTROOMSRECEPTIONEXISTING EXIT SIGNNEW EXIT SIGNNOTE: DOORS ARE UNLOCKED247, WITH TRAINED HOTELPERSONNEL THAT EXCEEDSOR IS EQUAL TO LIFE SAFETYPROVISIONS. EXCEPTIONTAKEN FOR PANIC HARDWAREAND SIGNAGE.TYP. DOOR CLEARANCEEGRESS PATH OF TRAVELNOT IN SCOPECONCIERGE
STORAGENOT IN SCOPEACCESSIBLE PATHEGRESS PATHEGRESS PATHEGRESS PATH
NOT IN SCOPENOT IN SCOPELIVING ROOMEGRESS PATH LOUNGE AREABAR AREABARADAVESTIBULEACCESSIBLE PATHEGRESS PATHEGRESS PATHV
E
S
T
I
B
U
L
E LIFTLIFT33-1/2" HIGH BARCOUNTER, REFERENCEA0.4 FOR ACCESSIBILITYREQUIREMENTSACCESSIBLE PATH34" HIGH TABLE28" HIGH TABLES3'-2"3'-2"111'-10"90'-0"ADAADAADAADA28" HIGH TABLESADAADA5'-0"ADAWAYFINDINGS
IG
N
AG
EFOR LIFTAT CHAIR 9WAYFINDING SIGNAGEFOR LIFT AT CHAIR 9WAYFINDING SIGNAGEFOR LIFT AT ELEMENT 47A0.51/8"=1'-0"BUILDING CODEANALYSIS - EGRESS& OCCUPANCYFile Path: P:\Proj-2018\21808.00_TLN Public Spaces\06_Documentation\01_Drawings\21808_A0.5 EGRESS 2.dwgPlot Date/Time: March 27, 2019 - 7:34 pm
COPYRIGHT 2019 ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGNTHE INFORMATION AND DESIGN INTENT CONTAINED ON THIS DOCUMENT ISTHE PROPERTY OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. NO PART OF THIS INFORMATION MAY BE USED WITHOUT THE PRIORWRITTEN PERMISSION OF ROWLAND+BROUGHTON ARCHITECTURE AND URBANDESIGN. ROWLAND+BROUGHTON ARCHITECTURE AND URBAN DESIGN SHALLRETAIN ALL COMMON LAW STATUTORY AND OTHER RESERVED RIGHTS,INCLUDING COPYRIGHT THERETO.ConsultantsIssue:SHEET TITLEPROJECT NO:DWG FILE:SCALE:21808_A0.5 EGRESS 2.dwgTHE LITTLE NELLPUBLIC SPACELOBBY & CHAIR 9675 E DURANT AVEASPEN, CO, 8161121808.0003.23.2018SITE MEASURE10.26.2018FOR CONTRACTOR BID01.18.2019CONSTRUCTION DOCUMENTS02.08.2019ASI 0011830 blake stdenver, co 80202303.308.1373500 w main staspen, co 81611970.544.9006rowland+broughtonarchitecture / urban design / interior design03.15.2019REVISION 0103.27.2019PERMIT COMMENTS03/28/201903/28/2019justinhFIRESPRINKLERSREQUIREDOCC LOAD:Chair 9 Lounge: 819+109=928net/15= 62 + 10 employees = 72 totalLiving Room/Upper Lounge: 986net/15= 66 total819 sf109 sf986 sfIn this scenario we would only assign anoccupant load the assembly spaces(restaurant/lounge/bar), thefoyer/reception/concierge spaces do nothave an occupant load assigned to them. Please revise your occupant loadcalculations as shown here (we removeyour egress paths and accessible routesfrom the square footages used incalculating occupant load). Please reviseyour plumbing fixture calculations to matchthese occupant loads as well.