Loading...
HomeMy WebLinkAboutFile Documents.630 E Cooper Ave.0005.2019 (2).ARBKM-SERIES Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Job Name: System Reference:Date: SUBMITTAL DATA: MXZ-4C36NA2 MULTI-INDOOR INVERTER HEAT-PUMP SYSTEM Specifications Model Name Unit Type MXZ-4C36NA2 Cooling* (Non-ducted / Ducted) Rated Capacity Btu/h 35,400 / 34,400 Capacity Range Btu/h 12,600-36,400 / 12,600-34,800 Rated Total Input W 3,760 / 3,940 Heating at 47°F* (Non-ducted / Ducted) Rated Capacity Btu/h 36,000 / 34,400 Capacity Range Btu/h 11,400-43,000 / 11,400-41,400 Rated Total Input W 3,020 / 3,100 Heating at 17°F* (Non-ducted/Ducted) Rated Capacity Btu/h 22,200 / 20,300 Rated Total Input W 3,340 / 3,450 Electrical Requirements Power Supply Voltage, Phase, Hertz 208 / 230V, 1-Phase, 60 Hz Recommended Fuse/Breaker Size A 25 MCA A 22.1 Voltage Indoor - Outdoor S1-S2 V AC 208 / 230 Indoor - Outdoor S2-S3 V DC ±24 Compressor INVERTER-driven Scroll Hermetic Fan Motor (ECM)F.L.A.2.43 Sound Pressure Level Cooling dB(A)54 Heating 56 External Dimensions (H x W x D)In (mm)31-11/32 x 37-13/32 x 13 (796 x 950 x 330) Net Weight Lbs (kg)139 (63) External Finish Munsell 3.0Y 7.8/1.1 Refrigerant Pipe Size O.D.Liquid (High Pressure)In (mm)1/4 (12.7) Gas (Low Pressure)A: 1/2 (6.35) ; B,C,D: 3/8 (9.52) Max. Refrigerant Line Length Ft (m)230 (70) Max. Piping Length for Each Indoor Unit Ft (m)82 (25) Max. Refrigerant Pipe Height Difference If IDU is Above ODU Ft (m)49 (15) If IDU is Below ODU 49 (15) Connection Method Flared/Flared Refrigerant R410A ACCESSORIES □3/8" x 1/2" Port Adapter (MAC-A454JP) □1/2" x 3/8" Port Adapter (MAC-A455JP) □1/2" x 5/8" Port Adapter (MAC-A456JP) □1/4" x 3/8" Port Adapter (PAC-493PI) □3/8" x 5/8" Port Adapter (PAC-SG76RJ) □M-NET Adapter (PAC-IF01MNT-E) □Base Heater (PAC-645BH-E) Outdoor Unit: MXZ-4C36NA2 (For data on specific indoor units, see the MXZ-C Technical and Service Manual.) * Rating Conditions per AHRI Standard: Cooling | Indoor: 80º F (27º C) DB / 67º F (19º C) WB Cooling | Outdoor: 95º F (35º C) DB / 23.9° C (75° F) WB Heating at 47ºF | Indoor: 70º F (21º C) DB / 60º F (16º C) WB Heating at 47ºF | Outdoor: 47º F (8º C) DB / 43º F (6º C) WB Heating at 17º F | Indoor: 70º F (21º C) DB Heating at 17º F | Outdoor: 17º F (-8º C) DB / 15º F (-9º C) WB01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. Notes: SPECIFICATIONS: MXZ-4C36NA2, contd. • Minimum of two Indoor Units must be connected to the MXZ-4C36NA2. • Minimum installed capacity cannot be less than 12,000 Btu/h. • Total connected capacity must not exceed 130% of outdoor unit capacity. • System can operate with only one Indoor Unit turned on. • Information provided at 208/230V. • For Reference: - MXZ-C Technical & Service Manual for detailed specifications and additional information per Indoor Unit Combination. - MXZ Series Multi-Zone Indoor/Outdoor Combination Table for allowed unit combinations. Indoor Unit Type SEER EER HSPF COP @ 47°F COP @ 17°F Non-ducted 19.2 9.4 11.0 3.50 2.67 Ducted and Non-ducted 17.6 9.05 10.4 3.38 2.61 Ducted 16.0 8.7 9.8 3.25 2.54 Outdoor Cooling 14 to 115° F (−10 to 46° C) DB Heating 5 to 65° F (−15 to 18° C) WB • Only 1 MVZ may be used on any system. • When an MVZ is connected, total connected capacity must be 100% or less. • When an MVZ is connected, no P-Series indoor units can be used (PCA, PLA, or PEAD). ENERGY EFFICIENCIES: NOTES: OPERATING RANGE: MVZ CONNECTION RULES: 01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. MXZ-4C36NA2 OPERATIONAL PERFORMANCE NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C + Unit D) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C Unit D 1 6 6,000 6 6,000 - - - 7,400 7,400 - - - 1 9 9,000 9 9,000 - - - 11,000 11,000 - - - 1 12 12,000 12 12,000 - - - 14,400 14,400 - - - 1 15 14,000 15 14,000 - - - 18,000 18,000 - - - 1 18 17,200 18 17,200 - - - 21,600 21,600 - - - 1 24 22,500 24 22,500 - - - 27,600 27,600 - - - 2 12 12,000 6 + 6 6,000 6,000 - - 14,800 7,400 7,400 - - 2 15 15,000 6 + 9 6,000 9,000 - - 18,400 7,400 11,000 - - 2 18 18,000 6 + 12 6,000 12,000 - - 22,000 7,500 14,500 - - 2 18 18,000 9 + 9 9,000 9,000 - - 22,000 11,000 11,000 - - 2 21 20,000 6 + 15 6,000 14,000 - - 25,400 7,400 18,000 - - 2 21 20,000 9 + 12 8,600 11,400 - - 25,400 11,000 14,400 - - 2 24 23,000 6 + 18 5,900 17,100 - - 28,000 7,100 20,900 - - 2 24 23,000 9 + 15 9,000 14,000 - - 28,000 10,600 17,400 - - 2 24 23,000 12 + 12 11,500 11,500 - - 28,000 14,000 14,000 - - 2 27 25,800 9 + 18 8,900 16,900 - - 28,000 9,400 18,600 - - 2 27 25,800 12 + 15 11,900 13,900 - - 28,000 12,400 15,600 - - 2 30 28,000 6 + 24 5,900 22,100 - - 28,000 5,900 22,100 - - 2 30 28,000 12 + 18 11,500 16,500 - - 28,000 11,200 16,800 - - 2 30 28,000 15 + 15 14,000 14,000 - - 28,000 14,000 14,000 - - 2 33 28,000 9 + 24 8,000 20,000 - - 28,000 8,000 20,000 - - 2 33 28,000 15 + 18 12,600 15,400 - - 28,000 12,700 15,300 - - 2 36 28,000 12 + 24 9,700 18,300 - - 28,000 9,600 18,400 - - 2 36 28,000 18 + 18 14,000 14,000 - - 28,000 14,000 14,000 - - 3 18 18,000 6 + 6 + 6 6,000 6,000 6,000 - 22,200 7,400 7,400 7,400 - 3 21 21,000 6 + 6 + 9 6,000 6,000 9,000 - 25,800 7,400 7,400 11,000 - 3 24 24,000 6 + 6 + 12 6,000 6,000 12,000 - 29,200 7,400 7,400 14,400 - 3 27 26,000 6 + 6 + 15 6,000 6,000 14,000 - 32,800 7,400 7,400 18,000 - 3 30 28,400 6 + 6 + 18 5,800 5,800 16,700 - 32,800 6,700 6,700 19,500 - 3 36 32,000 6 + 6 + 24 5,600 5,600 20,900 - 32,800 5,700 5,700 21,400 - 01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. MXZ-4C36NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C + Unit D) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C Unit D 3 24 24,000 6 + 9 + 9 6,000 9,000 9,000 - 29,200 7,300 10,900 10,900 - 3 27 26,000 6 + 9 + 12 5,800 8,700 11,600 - 32,800 7,400 11,000 14,400 - 3 30 28,400 6 + 9 + 15 5,900 8,800 13,700 - 32,800 6,700 9,900 16,200 - 3 33 32,000 6 + 9 + 18 6,000 8,900 17,100 - 32,800 6,100 9,000 17,700 - 3 39 32,000 6 + 9 + 24 5,100 7,700 19,200 - 32,800 5,300 7,800 19,700 - 3 30 28,400 6 + 12 + 12 5,700 11,400 11,400 - 32,800 6,700 13,000 13,000 - 3 33 32,000 6 + 12 + 15 6,000 12,000 14,000 - 32,800 6,100 11,900 14,800 - 3 36 32,000 6 + 12 + 18 5,500 10,900 15,600 - 32,800 5,600 10,900 16,300 - 3 42 32,000 6 + 12 + 24 4,700 9,500 17,800 - 32,800 4,900 9,600 18,300 - 3 36 32,000 6 + 15 + 15 5,600 13,200 13,200 - 32,800 5,600 13,600 13,600 - 3 39 32,000 6 + 15 + 18 5,200 12,000 14,800 - 32,800 5,200 12,600 15,100 - 3 42 32,000 6 + 18 + 18 4,800 13,600 13,600 - 32,800 4,800 14,000 14,000 - 3 27 26,000 9 + 9 + 9 8,700 8,700 8,700 - 32,800 10,900 10,900 10,900 - 3 30 28,400 9 + 9 + 12 8,500 8,500 11,400 - 32,800 9,900 9,900 13,000 - 3 33 32,000 9 + 9 + 15 9,000 9,000 14,000 - 32,800 9,000 9,000 14,800 - 3 36 32,000 9 + 9 + 18 8,200 8,200 15,600 - 32,800 8,300 8,300 16,200 - 3 42 32,000 9 + 9 + 24 7,100 7,100 17,800 - 32,800 7,300 7,300 18,300 - 3 33 32,000 9 + 12 + 12 8,700 11,600 11,600 - 32,800 9,100 11,900 11,900 - 3 36 32,000 9 + 12 + 15 8,200 11,000 12,800 - 32,800 8,300 10,900 13,600 - 3 39 32,000 9 + 12 + 18 7,500 10,100 14,400 - 32,800 7,700 10,000 15,100 - 3 39 32,000 9 + 15 + 15 7,800 12,100 12,100 - 32,800 7,700 12,600 12,600 - 3 42 32,000 9 + 15 + 18 7,200 11,100 13,700 - 32,800 7,100 11,700 14,000 - 3 36 32,000 12 + 12 + 12 10,700 10,700 10,700 - 32,800 10,900 10,900 10,900 - 3 39 32,000 12 + 12 + 15 10,100 10,100 11,800 - 32,800 10,100 10,100 12,600 - 3 42 32,000 12 + 12 + 18 9,300 9,300 13,400 - 32,800 9,400 9,400 14,100 - 3 42 32,000 12 + 15 + 15 9,600 11,200 11,200 - 32,800 9,400 11,700 11,700 - 4 24 24,000 6 + 6 + 6 + 6 6,000 6,000 6,000 6,000 29,600 7,400 7,400 7,400 7,400 4 27 27,000 6 + 6 + 6 + 9 6,000 6,000 6,000 9,000 33,200 7,400 7,400 7,400 11,000 4 30 30,000 6 + 6 + 6 + 12 6,000 6,000 6,000 12,000 35,800 7,200 7,200 7,200 14,100 4 33 32,000 6 + 6 + 6 + 15 6,000 6,000 6,000 14,000 35,800 6,600 6,600 6,600 16,000 01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. MXZ-4C36NA2 OPERATIONAL PERFORMANCE, contd. NON-DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C + Unit D) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C Unit D 4 36 32,000 6 + 6 + 6 + 18 5,500 5,500 5,500 15,600 32,800 5,500 5,500 5,500 16,200 4 42 32,000 6 + 6 + 6 + 24 4,700 4,700 4,700 17,800 32,800 4,900 4,900 4,900 18,200 4 30 30,000 6 + 6 + 9 + 9 6,000 6,000 9,000 9,000 35,800 7,200 7,200 10,700 10,700 4 33 32,000 6 + 6 + 9 + 12 5,800 5,800 8,700 11,600 35,800 6,600 6,600 9,800 12,800 4 36 35,400 6 + 6 + 9 + 15 6,100 6,100 9,100 14,200 36,000 6,100 6,100 9,000 14,800 4 39 36,000 6 + 6 + 9 + 18 5,700 5,700 8,500 16,200 36,000 5,600 5,600 8,400 16,400 4 36 35,400 6 + 6 + 12 + 12 5,900 5,900 11,800 11,800 36,000 6,100 6,100 11,900 11,900 4 39 36,000 6 + 6 + 12 + 15 5,700 5,700 11,400 13,300 36,000 5,600 5,600 11,000 13,700 4 42 36,000 6 + 6 + 12 + 18 5,200 5,200 10,500 15,000 36,000 5,200 5,200 10,200 15,300 4 42 36,000 6 + 6 + 15 + 15 5,400 5,400 12,600 12,600 36,000 5,200 5,200 12,800 12,800 4 33 32,000 6 + 9 + 9 + 9 5,800 8,700 8,700 8,700 35,800 6,600 9,700 9,700 9,700 4 36 35,400 6 + 9 + 9 + 12 5,900 8,900 8,900 11,800 36,000 6,100 9,000 9,000 11,800 4 39 36,000 6 + 9 + 9 + 15 5,700 8,500 8,500 13,300 36,000 5,600 8,400 8,400 13,700 4 42 36,000 6 + 9 + 9 + 18 5,200 7,900 7,900 15,000 36,000 5,200 7,800 7,800 15,200 4 39 36,000 6 + 9 + 12 + 12 5,500 8,300 11,100 11,100 36,000 5,600 8,400 11,000 11,000 4 42 36,000 6 + 9 + 12 + 15 5,300 7,900 10,500 12,300 36,000 5,200 7,800 10,200 12,800 4 42 36,000 6 + 12 + 12 + 12 5,100 10,300 10,300 10,300 36,000 5,300 10,200 10,200 10,200 4 36 35,400 9 + 9 + 9 + 9 8,900 8,900 8,900 8,900 36,000 9,000 9,000 9,000 9,000 4 39 36,000 9 + 9 + 9 + 12 8,300 8,300 8,300 11,100 36,000 8,400 8,400 8,400 10,900 4 42 36,000 9 + 9 + 9 + 15 7,900 7,900 7,900 12,300 36,000 7,800 7,800 7,800 12,700 4 42 36,000 9 + 9 + 12 + 12 7,700 7,700 10,300 10,300 36,000 7,800 7,800 10,200 10,200 01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. MXZ-4C36NA2 OPERATIONAL PERFORMANCE, contd. DUCTED: # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C + Unit D) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C Unit D 1 9 9,000 9 9,000 - - - 10,900 10,900 - - - 1 12 12,000 12 12,000 - - - 13,600 13,600 - - - 1 15 15,000 15 15,000 - - - 18,000 18,000 - - - 1 18 17,200 18 17,200 - - - 21,600 21,600 - - - 1 24 24,000 24 24,000 - - - 26,000 26,000 - - - 2 18 18,000 9 + 9 9,000 9,000 - - 21,800 10,900 10,900 - - 2 21 21,000 9 + 12 9,000 12,000 - - 24,500 10,900 13,600 - - 2 24 24,000 9 + 15 9,000 15,000 - - 27,200 10,300 16,900 - - 2 27 26,200 9 + 18 9,000 17,200 - - 28,000 9,400 18,600 - - 2 33 28,000 9 + 24 7,600 20,400 - - 28,000 8,300 19,700 - - 2 24 24,000 12 + 12 12,000 12,000 - - 27,200 13,600 13,600 - - 2 27 26,200 12 + 15 11,600 14,600 - - 28,000 12,100 15,900 - - 2 30 28,000 12 + 18 11,500 16,500 - - 28,000 10,800 17,200 - - 2 36 28,000 12 + 24 9,300 18,700 - - 28,000 9,600 18,400 - - 2 30 28,000 15 + 15 14,000 14,000 - - 28,000 14,000 14,000 - - 2 33 28,000 15 + 18 13,000 15,000 - - 28,000 12,700 15,300 - - 2 36 28,000 18 + 18 14,000 14,000 - - 28,000 14,000 14,000 - - 3 27 27,000 9 + 9 + 9 9,000 9,000 9,000 - 32,700 10,900 10,900 10,900 - 3 30 30,000 9 + 9 + 12 9,000 9,000 12,000 - 32,700 10,100 10,100 12,600 - 3 33 32,000 9 + 9 + 15 8,700 8,700 14,500 - 32,700 9,000 9,000 14,800 - 3 36 32,000 9 + 9 + 18 8,200 8,200 15,600 - 32,700 8,200 8,200 16,300 - 3 42 32,000 9 + 9 + 24 6,900 6,900 18,300 - 32,700 7,500 7,500 17,800 - 3 33 32,000 9 + 12 + 12 8,700 11,600 11,600 - 32,700 9,400 11,700 11,700 - 3 36 32,000 9 + 12 + 15 8,000 10,700 13,300 - 32,700 8,400 10,500 13,800 - 3 36 32,000 12 + 12 + 12 10,700 10,700 10,700 - 32,700 10,900 10,900 10,900 - 3 39 32,000 9 + 12 + 18 7,500 10,100 14,400 - 32,700 7,700 9,600 15,300 - 3 39 32,000 9 + 15 + 15 7,400 12,300 12,300 - 32,700 7,600 12,600 12,600 - 3 39 32,000 12 + 12 + 15 9,800 9,800 12,300 - 32,700 9,800 9,800 13,000 - 3 42 32,000 9 + 15 + 18 7,000 11,700 13,400 - 32,700 7,100 11,700 14,000 - 3 42 32,000 12 + 12 + 18 9,300 9,300 13,400 - 32,700 9,100 9,100 14,500 - 01/08/2019 Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. MXZ-4C36NA2 OPERATIONAL PERFORMANCE, contd. # of indoor unit Total Nominal Capacity (x1000 Btu/h) Total Indoor Unit Capacity (Btu/h) Operational Performance for Indoor Unit Combinations (Unit A + Unit B + Unit C + Unit D) Cooling Capacity Range (Btu/h) Heating Capacity Range (Btu/h) Unit A Unit B Unit C Unit D 3 42 32,000 12 + 15 + 15 9,100 11,400 11,400 - 32,700 9,000 11,900 11,900 - 4 36 34,400 9 + 9 + 9 + 9 8,600 8,600 8,600 8,600 34,400 8,600 8,600 8,600 8,600 4 39 34,800 9 + 9 + 9 + 12 8,000 8,000 8,000 10,700 34,800 8,200 8,200 8,200 10,200 4 42 35,200 9 + 9 + 9 + 15 7,500 7,500 7,500 12,600 35,200 7,600 7,600 7,600 12,500 4 42 35,200 9 + 9 + 12 + 12 7,500 7,500 10,100 10,100 35,200 7,800 7,800 9,800 9,800 DUCTED: 01/08/2019 1340 Satellite Boulevard. Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Specifications are subject to change without notice. © 2016 Mitsubishi Electric US, Inc. FORM# MXZ-4C36NA2 for Multiple Indoor Unit Styles - 201611 DIMENSIONS: MXZ-4C36NA2 14 MXZ-4C36NA Unit: inch (mm) Lock nut Conduit plates Conduit connector OBH702A Unit: inch (mm) 01/08/2019