HomeMy WebLinkAboutFile Documents.630 E Cooper Ave.0005.2019 (4).ARBKJob Name: System Reference:Date: Indoor Unit: MSZ-GL09NA Wireless Remote Controller GENERAL FEATURES • Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Hot-Start Technology: no cold air rush at equipment startup or when restarting after Defrost Cycle • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button SUBMITTAL DATA: MSZ-GL09NA 9,000 BTU/H WALL-MOUNTED INDOOR UNIT FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES 01/08/2019 Cooling Capacity1 Btu/h 9,000 Heating Capacity2 Btu/h 10,900 Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 MCA A 1 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 Airflow Rate at Cooling, Dry CFM 399-321-237-170-145 Airflow Rate at Cooling, Wet CFM 364-286-201-134-109 Airflow Rate at Heating, Dry CFM 406-321-237-170-145 Sound Pressure Level (Cooling)dB(A)43-37-30-22-19 Sound Pressure Level (Heating)dB(A)43-37-30-22-19 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Refrigerant Type R410A Piping Gas Pipe Size O.D. (Flared)In. (mm)3/8 (9.52) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Nominal Conditions 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB Capacity varies based on the number of indoor units operating and the model of the MXZ unit. For reference to connected capacity charts, please refer MXZ Multi-Zone Outdoor Unit Operational Performance. Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. SPECIFICATIONS: MSZ-GL09NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 01/08/2019 Anti-Allergy Enzyme Filter □ MAC-408FT-E Backlit, Wall-mounted, Wireless Controller □ MHK1 Portable Central Controller □ MCCH1 Wired MA Controller □ PAR-33MAA1 Simple MA Controller □ PAC-YT53CRAU1 Touch MA Controller □ PAR-CT01MAU-SB1 Wired Remote Sensor □ PAC-SE41TS-E Lockdown Bracket for Wireless, Hand-held, Remote Controller □ RCMKP1CB Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 □ MOS1 System Control Interface □ MAC-333IF-E2 Wireless Interface □ PAC-USWHS002-WF-1 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3 Blue Diamond Sensor Extension Cable—15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable—6.5 Ft.□ C13-192 Blue Diamond MultiTank—collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump—230V application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] □ X87-711 - 110V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h [recommended] □ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 Btu/h □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow)□ DPLS2 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black □ TAZ-MS303 3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White □ TAZ-MS303W 1/4" x 3/8" x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-15 1/4" x 3/8" x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-30 1/4" x 3/8" x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-50 1/4" x 3/8" x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS143812T-65 1 Requires MAC-333IF-E 2 Allows M-Series indoor units to connect to an MA controller ACCESSORIES: MSZ-GL09NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 01/08/2019 Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (GL06/09/12NA), ø1/2 (GL15NA)) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D FORM# MSZ-GL09NA FOR MXZ-C MULTI-ZONE HEAT-PUMP SYSTEMS - 201808Ver1 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MSZ-GL09NA Specifications are subject to change without notice.© 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 01/08/2019